• Title/Summary/Keyword: magnetic water

Search Result 673, Processing Time 0.033 seconds

Feasibility Study on Magnetic Nanoparticle Hyperthermia in Low Field MRI (저자장 자기공명영상 시스템 내에서 초상자성 나노입자 온열치료를 위한 발열 평가)

  • Kim, Ki Soo;Cho, Min Hyoung;Lee, Soo Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.4
    • /
    • pp.105-110
    • /
    • 2014
  • For the combination of MRI and magnetic particle hyperthermia(MPH), we investigated the relative heating efficiency with respect to the strength of the static magnetic field under which the magnetic nanoparticles are to be heated by RF magnetic field. We performed nanoparticle heating experiments at the fringe field of 3T MRI magnet with applying the RF magnetic field perpendicularly to the static magnetic field. The static field strengths were 0T, 0.1T, 0.2T, and 0.3T. To prevent the coil heat from conducting to the nanoparticle suspension, we cooled the heating solenoid coil with temperature-controlled water with applying heat insulators between the solenoid coil and the nanoparticle container. We observed significant decrease of heat generation, up to 6% at 0.3T(100% at 0T), due to the magnetic saturation of the nanoparticles of 15 nm diameter under the static field. We think MPH is still feasible at low magnetic field lower than 0.3T if stronger RF magnetic field generation is permitted.

기능성기를 지닌 고분자 자성체를 이용한 수용액 중 납이온 추출

  • 서형석;최규찬;나인욱;황경엽
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.175-176
    • /
    • 2004
  • To develope of efficient method for decontaminating of lead ions from industrial wastewater, treatment of aqueous lead solution with magnetic beads was investigated. Immobilization of carboxyl groups on tile surface of magnetic beads was carried out to introduce chelate effect between lead ions and beads. Experiments were performed with lead solutions and magnetic beads at pH 6. Lead ions were extracted during 1 hour, After extraction, magnetic beads were separated from water by outer magnetic force and the solution was analysed by atomic absorption spectroscopy (AAS). Over 90 % of lead ions could be removed from aqueous solution after beads application. This result indicate that magnetic beads can be used as a efficient method for removing lead ions from industrial wastewater.

  • PDF

Introduction of the Magnetic Pulse Compressor (MPC) - Fundamental Review and Practical Application

  • Choi, Jae-Gu
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.484-492
    • /
    • 2010
  • Magnetic switch is a kind of saturable inductor, which utilizes nonlinearity of the magnetization curve of ferromagnetic materials. The right understanding of the saturation phenomena, magnetic properties, voltage-time product, and switching characteristics of the magnetic switch is essential in designing the magnetic pulse compressor (MPC). In this paper, the historical background of research on the MPC, fundamental physical properties of the magnetic switches, and application fields of the MPC are presented. Further, an in-depth analysis of pulse compression in series and parallel MPCs is incorporated. As practical application examples, a series MPC used for water treatments and a parallel MPC used for pulsed electric field (PEF) inactivation of bacteria are cited.

Magnetic Field Simulation for Circumferential Magnetic Phase Produced in Steam Generator Tube

  • Ryu, Kwon-Sang;Son, Derac;Park, Duck-Gun;Jung, Jae-Kap
    • Journal of Magnetics
    • /
    • v.16 no.2
    • /
    • pp.88-91
    • /
    • 2011
  • Steam generator tubes (SGTs) in nuclear power plants (NPPs) are a boundary between the primary side generating heat by nuclear fission and the secondary side generating electric power by a turbine. The water inside the SGT is high temperature and high pressure. Therefore, defects and magnetic phases (MPs) are partly produced in non-magnetic SGT by high stresses and temperatures. This causes trouble regarding the safety of SGTs but it is difficult to detect the MP using the conventional eddy current technique (ECT). In particular, a circumferential defect (CD) and circumferential magnetic phase (CMP) cannot detected by ECT. Consequently, a new method is needed to detect CDs and CMPs in SGT. A new U-type yoke with two types of coils was designed and the reactance signal by the CMPs and CDs in the SGT material was simulated.

Development of 1[kW] BLDC Motor Drive System and Magnetic Coupler for Water Thrust (1kW급 수중로봇 추진용 브러시레스 직류전동기 구동시스템 및 자기커플러 개발)

  • Kim, Tae-Hyoung;Ha, Byung-Gil;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1103-1104
    • /
    • 2011
  • This paper presents 1kW BLDC motor drive system and magnetic coupler for water thrust in ROV. In order to get a high performance and reliability, some design flow is proposed in this paper. The proposed system is verified by the experimental tests.

  • PDF

A Magnetic Survey on the Lake for the Detection of the Unexploded Ordnances (위험물탐지를 위한 수상 자력탐사)

  • Jo Churl-hyun;Jung Yong Hyun;Lee Hyo Jin
    • Geophysics and Geophysical Exploration
    • /
    • v.6 no.1
    • /
    • pp.23-27
    • /
    • 2003
  • A magnetic survey on the lake war carried out to explore the possible UXO (unexploded ordnance) under the water. A magnetic gradiometer with 2 magnetometer sensors was used, which measures total magnetic intensity. For the positioning of the measurement points on the water, RTK (real time kinematic) survey system was used. The theoretical responses were calculated assumming the dimension and the material of the UXO so that the detectability could be investigated. Since the areal size of the survey vessel was rather small, the influence from the magnetic material of the vessel and the other equipments such as a laptop computer was not negligible, and the influence did not remain constant during the survey due to the change of survey direction. These effects were reduced remarkably using moving average technique. The result reveals the lineament of a pipe line laid on the bottom of the lake, which can be regarded as an indirect proof of detectability of the method.

Water-Fat Imaging with Automatic Field Inhomogeneity Correction Using Joint Phase Magnitude Density Function at Low Field MRI (저자장 자기공명영상에서 위상-크기 결합 밀도 함수를 이용한 자동 불균일 자장 보정 물-지방 영상 기법)

  • Kim, Pan-Ki;Ahn, Chang-Beom
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.57-66
    • /
    • 2011
  • Purpose : A new inhomogeneity correction method based on two-point Dixon sequence is proposed to obtain water and fat images at 0.35T, low field magnetic resonance imaging (MRI) system. Materials and Methods : Joint phase-magnitude density function (JPMF) is obtained from the in-phase and out-of-phase images by the two-point Dixon method. The range of the water signal is adjusted from the JPMF, and 3D inhomogeneity map is obtained from the phase of corresponding water volume. The 3D inhomogeneity map is used to correct the inhomogeneity field iteratively. Results : The proposed water-fat imaging method was successfully applied to various organs. The proposed 3D inhomogeneity correction algorithm provides good performances in overall multi-slice images. Conclusion : The proposed water-fat separation method using JPMF is robust to field inhomogeneity. Three dimensional inhomogeneity map and the iterative inhomogeneity correction algorithm improve water and fat imaging substantially.

Characteristics of GMR-SV Sensor for Measurement of Mineral Contents in Edible Water

  • Kim, Da-Woon;Lee, Ju-Hee;Kim, Min-Ji;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.14 no.2
    • /
    • pp.80-85
    • /
    • 2009
  • The mineral dissolution sensor system using GMR-SV and glass/Mg(200 nm) was prepared and characterized. The magnetic field sensitivity of GMR-SV to microscopic magnetic variation was about 0.8%/Oe. The change that occurs when Mg-film dissolves in water, the solubility of water, which is one of the basic properties of mineral water, was sensed by measuring the subtle variation of an electric current. In the case of edible water with Mg mineral added, bubbles were generated on the surface of the Mg film in the first 45 minutes, and the number of drops that were dissolved more rapidly than with the tap and DI waters later reduced to zero. For the edible water samples that each had different mineral Mg concentrations, the Mg solubility speed significantly differed. After injecting Mg film into the edible water, the magnetoresistance of the output GMR-SV signal decreased from a maximum of $45.4\;{\Omega}$ to a minimum of $43.6\;{\Omega}$. The measurement time was within 1 min, giving the rate of change ${\Delta}R/{\Delta}t=0.18\;{\Omega}/s$. This measurement system can be applied to develop a mineral Mg solubility GMR-SV sensor that can be used to sense the change from edible water to reduced alkali.

Preparation and properties of water-based magnetic fluid with synthesized magnetite (합성마그네타이트를 이용한 수상자성유체의 제조 및 특성)

  • Kim, Mahn;Oh, Jae-Hyun;Seo, Ho-Jun;Cho, Moung-Ho;Kim, Mi-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.2
    • /
    • pp.173-178
    • /
    • 1994
  • The water-based magnetic fluids were prepared with the synthesized ultra-fine magnetite, oleic acid and SDBS (sodium dodecyl benzene sulfonate) as surfactants. The dispersion of water-based magnetic fluids was about 90 % when the added amounts of oleic acid and SDBS for magnetite(27 g) were more than $2.66{\times}10^{-3}$ mol and 10 g respectively. As the solid content increased from o. 05 g/cc to 0.4 g/cc, saturation magnetization of magnetic fluids at 5 kOe increased from 1.98 emu/g to 9.63 emu/g at $Fe^{2+}/Fe^{3+}=0.5$ and from 2.7 emu/g to 14.63 emu/g at $Fe^{2+}/Fe^{3+}=1.0$, and the its viscosity increased from 1.3 cp to 4.4 cp at $Fe^{2+}/Fe^{3+}=0.5$. pH region of oleic acid and SDBS stabilized water-based mag¬netic fluids was stable was in the range of pH 3.0 to pH 11.0. Stability of Water-based magnetic fluids can be obtained by observation of magnetic memory patterns on the VCR tape.