• Title/Summary/Keyword: magnetic measurements

Search Result 775, Processing Time 0.029 seconds

A study on the electrical and magnetic properties of Viologen-TCNQ(2:2) LB films (Viologen-TCNQ(2:2) LB막의 전기 및 자기적 특성에 관한 연구)

  • 이용수;신동명;김태완;강도열
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.195-198
    • /
    • 1996
  • In conducting systems based on LB films, TCNQ derivatives have been extensively studied as electron acceptor molecules. We have investigated the optical, electrical, and magnetic properties of Viologen-(TCNQ ̄)$_2$LB films. In UV/visible absorption measurements, we have observed TCNQ ̄ peak at 380 nm and dimer peak at 620 nm. The electron spin resonance measurements infer that Viologen-(TCNQ ̄)$_2$LB film exhibits anisotropic properly. In other words, the LB film shows angular dependence. Iodine doping affects the degree of charge transfer and the conductivity of the films. The UV/visible absorption spectra of the LB film doped with I$_2$show peaks at near 400~430 nm and there is no dimer absorption peak. The in-plane electrical conductivity of the undoped film is approximately 4.2$\times$10$^{-6}$ S/cm.

  • PDF

Collapse of Charge Ordering in Ru-doped Mono-layered Manganites

  • Hong, Chang-Seop;Kim, Wan-Seop;Hur, Nam-Hwi
    • Journal of Magnetics
    • /
    • v.8 no.2
    • /
    • pp.85-88
    • /
    • 2003
  • The magnetic and transport properties far single crystals of Ru-doped mono-layered manganites $La_{0.5}Sr_{1.5}-Mn_{1-x}Ru_xO_4$ (0$\leq$$\chi$$\leq$0.1) have been studied using neutron diffraction and magnetization measurements. Temperature dependent magnetization data reveal that with an increase in the Ru concentration the parent charge ordered antiferromagnetic state is gradually destroyed and new ferromagnetic phase evolves. In the low Ru-doped system spin glass behavior is apparent in low temperature region, which is confirmed by ac and do magnetization measurements. The competing magnetic interaction between Mn/Mn and Mn/Ru couples is the most likely cause of the spin glass transition.

Silicon Nitride Thin Film Deposition Using ECR Plasma (ECR 플라즈마를 이용한 실리콘화박막증착)

  • 송선규;장홍영
    • Journal of the Korean institute of surface engineering
    • /
    • v.23 no.4
    • /
    • pp.218-224
    • /
    • 1990
  • Silicon nitride thin(SiNx) is deposited onto 3 inch silicon wafor using ECR plasma apparatus. For the two different plasma extraction windows size, the thin films which were deposited by changing the SiH4/N2 gas fole at at 1.5mTorr without substrate heating are analyzed through the XPS and wlliposometer measurements. The very uniform and good quality silicon nitride thin film were obtained with the analyzed results of the deposited films, and particularly, ion temperature perpendicular to the magnetic filed was nearly same as the neutral gas temperature. The large amount of plasma loss in the transport process following magnetic field lines could be seen from the plasma emission intensity measurements.

  • PDF

Comparison of Magnetization loss of YBCO wires and BSCCO Wires

  • Lim Hyoung-Woo;Lee Hee-Joon;Cha Guee-Soo;Lee Ji-Kwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.2
    • /
    • pp.33-36
    • /
    • 2006
  • Multi-stacked HTS wires are needed to conduct large current in the power application. In this paper, magnetization losses of the multi-stacked YBCO wire and the BSCCO wire have been measured and compared. 4 types of YBCO wires and BSCCO wires, that is, single, 2-stacked, 3-stacked and 4-stacked, have been tested. HTS multi-stacked wires were fabricated using face-to-face type stacking method. Measurements of magnetization loss were performed under various angles of external magnetic field to consider the anisotropic characteristics of HTS wires. The ratios of the magnetization loss by multiple stacking of superconducting wires were presented. Measurements results show that loss reduction ratios have three distinct regions due to the magnitude of external magnetic field, the material of HTS wire and number of stacks.

Ankle Morphometry in Adults using MRI (성인에서 자기 공명 영상을 이용한 족관절 형태 계측)

  • Yoo, Moon-Jib;Kim, You-Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.1
    • /
    • pp.18-22
    • /
    • 2007
  • Purpose: To provide basic data on anatomy of the ankle joint in adults using magnetic resonance imaging as well as to compare measurements with available data of corresponding dimension in the different sizes of the total ankle replacements design ($HINTEGRA^{(R)}$). Materials and Methods: Magnetic resonance (MR) sagittal and coronal images from one hundred-forty nine were studied. Post traumatic, arthritic, or grossly deformed ankles at any reason were excluded. Lengths, widths of the main parts of this articulation and also the radius of curvature of talar dome were measured in the MR images. Statistical analysis was performed on these measurements. Results: On MR coronal image data, average tibial width was $30.0{\pm}4.1\;mm$ and talar width was $27.0{\pm}3.4\;mm$. On sagittal image date, average anteroposterior length of the distal tibia was $39.0{\pm}4.2\;mm$, average anteroposterior length of the talus was $31.3{\pm}2.8\;mm$, and average sagittal radius of curvature of talar dome was $20.1{\pm}2.9\;mm$. All measurements in male were significantly larger than in female (p<0.01), but a significant difference according to age was not found. Conclusion: Ankle morphometric data define a basis of size, particularly useful in the design of ankle prostheses.

  • PDF

Muscular Adaptations and Novel Magnetic Resonance Characterizations of Spinal Cord Injury

  • Lim, Woo-Taek
    • Physical Therapy Korea
    • /
    • v.22 no.2
    • /
    • pp.70-80
    • /
    • 2015
  • The spinal cord is highly complex, consisting of a specialized neural network that comprised both neuronal and non-neuronal cells. Any kind of injury and/or insult to the spinal cord leads to a series of damaging events resulting in motor and/or sensory deficits below the level of injury. As a result, muscle paralysis (or paresis) leading to muscle atrophy or shrinking of the muscle along with changes in muscle fiber type, and contractile properties have been observed. Traditionally, histology had been used as a gold standard to characterize spinal cord injury (SCI)-induced adaptation in spinal cord and skeletal muscle. However, histology measurements is invasive and cannot be used for longitudinal analysis. Therefore, the use of conventional magnetic resonance imaging (MRI) is promoted to be used as an alternative non-invasive method, which allows the repeated measurements over time and secures the safety against radiation by using radiofrequency pulse. Currently, many of pathological changes and adaptations occurring after SCI can be measured by MRI methods, specifically 3-dimensional MRI with the advanced diffusion tensor imaging technique. Both techniques have shown to be sensitive in measuring morphological and structural changes in skeletal muscle and the spinal cord.

Improved Perfusion Contrast and Reliability in MR Perfusion Images Using A Novel Arterial Spin Labeling

  • Jahng, Geon-Ho;Xioaping Zhu;Gerald Matson;Weiner, Michael-W;Norbert Schuff
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.341-344
    • /
    • 2002
  • Neurodegenerative disorders, like Alzheimer's disease, are often accompanied by reduced brain perfusion (cerebral blood flow). Using the intrinsic magnetic properties of water, arterial spin labeling magnetic resonance imaging (ASLMRI) can map brain perfusion without injection of radioactive tracers or contrast agents. However, accuracy in measuring perfusion with ASL-MRI can be limited because of contributions to the signal from stationary spins and because of signal modulations due to transient magnetic field effects. The goal was to optimize ASL-MRI for perfusion measurements in the aging human brain, including brains with Alzheimer's disease. A new ASL-MRI sequence was designed and evaluated on phantom and humans. Image texture analysis was performed to test quantitatively improvements. Compared to other ASL-MRI methods, the newly designed sequence provided improved signal to noise ratio improved signal uniformity across slices, and thus, increased measurement reliability. This new ASL-MRI sequence should therefore provide improved measurements of regional changes of brain perfusion in normal aging and neurodegenerative disorders.

  • PDF

FPCB-based Birdcage-Type Receiving Coil Sensor for Small Animal 1H 1.5 T Magnetic Resonance Imaging System (소 동물 1H 1.5 T 자기공명영상 장치용 유연인쇄기판 기반 새장형 수신 코일 센서)

  • Ahmad, Sheikh Faisal;Kim, Hyun Deok
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.245-250
    • /
    • 2017
  • A novel method to implement a birdcage-type receiving coil sensor for use in a magnetic resonance imaging(MRI) system has been demonstrated employing a flexible printed circuit board (FPCB) fabrication technique. Unlike the conventional methods, the two-dimensional shape of the coil sensor is first implemented as a FPCB and then it is attached to the surface of a cylindrical supporting structure to implement the three-dimensional birdcage-type coil sensor. The proposed method is very effective to implement object-specific MRI coil sensors especially for small animal measurements in research and preclinical applications since the existing well-developed FPCB-based techniques can easily meet the requirements on accuracies and costs during coil implement process. The performances of the coil sensor verified through $^1H$ 1.5T MRI measurements for small animals and it showed excellent characteristics by providing a high spatial precision and a high signal-to-noise ratio.

Power Absorption Measurements during NMR Experiments

  • Felix-Gonzalez, N.;Urbano-Bojorge, A.L.;de Pablo, C. Sanchez-L;Ferro-Llanos, V.;del Pozo-Guerrero, F.;Serrano-Olmedo, J.J.
    • Journal of Magnetics
    • /
    • v.19 no.2
    • /
    • pp.155-160
    • /
    • 2014
  • The heating produced by the absorption of radiofrequency (RF) has been considered a secondary undesirable effect during MRI procedures. In this work, we have measured the power absorbed by distilled water, glycerol and egg-albumin during NMR and non-NMR experiments. The samples are dielectric and examples of different biological materials. The samples were irradiated using the same RF pulse sequence, whilst the magnetic field strength was the variable to be changed in the experiments. The measurements show a smooth increase of the thermal power as the magnetic field grows due to the magnetoresistive effect in the copper antenna, a coil around the probe, which is directly heating the sample. However, in the cases when the magnetic field was the adequate for the NMR to take place, some anomalies in the expected thermal powers were observed: the thermal power was higher in the cases of water and glycerol, and lower in the case of albumin. An ANOVA test demonstrated that the observed differences between the measured power and the expected power are significant.

Step-Up Asymmetrical Nine Phase Delta-Connected Transformer for HVDC Transmission

  • Ammar, Arafet Ben;Ammar, Faouzi Ben
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1920-1929
    • /
    • 2018
  • In order to provide a source for nine phases suitable for 18-pulse ac to dc power, this paper proposes a new structure for a step-up asymmetrical delta-connected transformer for converting three-phase ac power to nine-phase ac power. The design allows for symmetry between the nine output voltages to improve the power quality of the supply current and to minimize the THD. The results show that this new structure proves the equality between the output voltages with $40^{\circ}-{\alpha}$ and $40^{\circ}+{\alpha}$ phase shifting and produces symmetrical output currents. This result in the elimination of harmonics in the network current and provides a simulated THD that is equal to 5.12 %. An experimental prototype of the step-up asymmetrical delta-autotransformer is developed in the laboratory and the obtained results give a network current with a THD that is equal to 5.35%. Furthermore, a finite element analysis with a 3D magnetic field model is made based on the dimensions of the 4kVA, 400 V laboratory prototype three-phase with three-limb delta-autotransformer with a six-stacked-core in each limb. The magnetic distribution flux, field intensity and magnetic energy are carried out under open-circuit operation or load-loss.