• Title/Summary/Keyword: magnetic measurement

Search Result 1,247, Processing Time 0.04 seconds

A Study on Temperature Properties Analysis for Tension Measurement of Steel Cables Using Magnetic Sensor (자기센서에 의한 강재 케이블 장력측정에서 온도특성에 대한 연구)

  • Park, Hae-won;Ahn, Bong-young;Lee, Seung-seok;Park, Jeong-hak
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.2 s.54
    • /
    • pp.181-188
    • /
    • 2009
  • Measuring the tensile strength of steel cables used to support bridges is a critical inspection item in terms of the safety of a bridge. Today, cable tension is measured with the vibration method and loadcell. Recently, some advanced countries have conducted studies on measuring tension with magnetic method and are suggesting prospective results. Since there were no such studies ongoing in Korea, we began a study on measuring tension with magnetic method as we are undergoing researches to improve the precision of measurements. It is necessary to consider the influence for the magnetic field and the temperature of steel cables in tension measurement of magnetic method. In this paper, we tested an output characteristic of tension sensor according to temperature and deduced temperature compensation coefficient in the given magnetic field and applied the compensation coefficient to the tension measurement system in the lab. We analyzed and evaluated testing results for the output voltages of the tension sensor according to cable tensions.

Displacement Sensorless Active Magnetic Bearing Control by Current Measurement (전류신호를 이용한 능동 자기 베어링계의 제어)

  • 권계시;정호섭;이종원
    • Journal of KSNVE
    • /
    • v.5 no.1
    • /
    • pp.49-57
    • /
    • 1995
  • An electronic circuit device is developed such that the displacement between an electromagnet and a moving target can be estimated from the coil current measurement, and then applied to an active magnetic bearing system. In order to levitate the shaft without using displacement sensor the stable control gains are obtained from the linearized model which includes the gap estimation circuit. Experimental results show that the shaft, by the estimated gap feedback, can be levitated within $\pm$6 ${\mu}m$ positioning error.

  • PDF

Measurement and Comparison of Iron Loss in Bonded- and Embossed-Type Segmented Stator Cores for IPMSM

  • Jeong, Kwangyoung;Zhang, Dianhai;Kwon, Jaehoon;Ren, Ziyan;Koh, Chang-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2013-2018
    • /
    • 2014
  • According to the manufacturing process of the laminated stator core for an inserted permanent magnet synchronous motor (IPMSM), the iron loss may be different. It is because the mechanical stress imposed to electrical steel sheet is strongly dependent on the manufacturing process. This paper proposes a new iron loss measurement algorithm which utilizes the induced voltage of a search coil and exciting current. The method is effective even when the distribution of magnetic flux density is not uniform along the magnetic flux path as well as uniform. The developed iron loss measurement system is applied to bonded- and embossed-type segmented stator cores of an IPMSM, and the iron losses are quantitatively compared.

Research of operators and patients exposed to electromagnetic field in the hospital (병원에서의 환자, 의료진의 전자파 노출 실태 조사)

  • Ji, Hyo-Chul;Hong, Hyun-Ki;Kim, Sung-Woo;Lee, Ju-Hyung;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.70-72
    • /
    • 2007
  • In this study, electromagnetic fields emitted from the various environment in the hospital were measured. Measurement spot was patients' head. To monitor how much magnetic fields are emitting from operation room, monitoring device was attached to 19 anesthesiologist and monitoring lasted 8 hours. We also took a measurement from various medical devices. Devices include ESWL, PET, MRI, CT, Gamma knife, X-ray, Angiogram, Echocardiogram, Upper GI and Linear Accelerator. Electromagnetic fields were measured from 10 spots from each of 5 patient waiting room. As a results, there were no places showing risk of high exposure. All the measurement values were below the reference levels for general public exposure to time varying electric and magnetic fields which is issued by ICNIRP.

  • PDF

The Effect of Transverse Magnetic field on Macrosegregation in vertical Bridgman Crystal Growth of Te doped InSb

  • Lee, Geun-Hee;Lee, Zin-Hyoung
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1996.06a
    • /
    • pp.522-522
    • /
    • 1996
  • An investigation of the effects of transverse magnetic field and Peltier effect on melt convection and macrosegregation in vertical Bridgman crystal grosth of Te doped InSb was been carried out by means of microstructure observation, Hall measurement, electrical resistivity measurement and X-ray analysis. Before the experiments, Interface stability, convective instability and suppression of convection by magnetic field were calculated theoretically. After doping 1018, 1019 cm-3 Te in InSb, the temperature of Bridgman furnace was set up at $650^{\circ}C$. The samples were grown in I.D. 11mm, 100mm high quartz tube. The velocity of growth was about 2${\mu}{\textrm}{m}$/sec. In order to obtain the suppression of convection by magnetic field in the middle of growth, 2-4KG magnetic field was set on the melt. For searching of the shape of solid-liquid interface and the actual velocity of crystal growth, let 2A current flow from solid to liquid for 1second every 50seconds repeatedly (Peltier effect). The grown InSb was polycrystal, and each grain was very sharp. There was no much difference between the sample with and without magnetic field at a point of view of microstructure. For the sample with Peltier effect, the Peltier marks(striation) were observed regularly as expected. Through these marks, it was found that the solid-liquid interface was flat and the actual growth velocity was about 1-2${\mu}{\textrm}{m}$/sec. On the ground of theoretical calculation, there is thermosolutal convection in the Te doped InSb melt without magnetic field in this growth condition. and if there is more than 1KG magnetic field, the convection is suppressed. Through this experiments, the effective distribution coefficients, koff, were 0.35 in the case of no magnetic field, and 0.45 when the magnetic field is 2KG, 0.7 at 4KG. It was found that the more magnetic field was applied, the more convection was suppressed. But there was some difference between the theoretical calculation and the experiment, the cause of the difference was thought due to the use of some approximated values in theoretical calculation. In addition to these results, the sample with Peltier effect showed unexpected result about the Te distribution in InSb. It looked like no convection and no macrosegregation. It was thought that the unexpected behavior was due to Peltier mark. that is, when the strong current flew the growing sample, the mark was formed by catching Te. As a result of the phenomena, the more Te containing thin layer was made. The layer ruled the Hall measurement. The values of resistivity and mobility of these samples were just a little than those of other reference. It was thought that the reason of this result was that these samples were due to polycrystal, that is, grain boundaries had an influence on this result.

  • PDF

A Study on Surface Tension Measurement for the Water through Electro-Magnetic Field (전자장을 통과한 물의 표면장력 측정에 대한 연구)

  • 고영하
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.7
    • /
    • pp.826-831
    • /
    • 2003
  • The purpose of this study was to measure the surface tension of hard water through electro-magnetic field for investigating the effect of electro-magnetic water treatment. The maximum reduction of surface tension was 8% comparing to the no treatment case. When the flow velocity through the permanent magnetic device (PMD) was 6.3 m/s, sample of hard water had the minimum surface tension.

Study on the Magnetic Field Measurement Using the Ultrasonic Transducer (초음파진동자를 이용한 자계측정방법 연구)

  • 손은영;류주현;윤광희;정영호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.350-355
    • /
    • 1997
  • A new magnetic field measuring system with induced coil is reported. This system consists of air-cared coil that is forced by the ultrasonic transducer. Induction voltage of coil is proportional to the DC magnetic field and the driving frequency of ultrasonic transducer by the principle of Faraday's law. The experimental measuring system is setup, and the possibility of a new magnetic field sensors is confirmed.

  • PDF

A New Model of Magnetic Force in Magnetic Levitation Systems

  • Lee, Y.S.;Yang, J.H.;Shim, S.Y.
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.4
    • /
    • pp.584-592
    • /
    • 2008
  • In this paper, we propose a new model of the magnetic control force exerted on the levitation object in magnetic levitation systems. The model assumes that the magnetic force is a function of the voltage applied to an electromagnet and the position of a levitation object. The function is not explicitly expressed but represented through a 2D lookup table constructed from the experimentally measured data. Unlike the conventional model that reveals only local characteristics of the magnetic force, the proposed model shows global characteristics satisfactorily. Specially devised measurement equipment is utilized in order to gather the data required for model construction. An experimental procedure to construct the model is presented. We apply the proposed model to designing a sliding mode controller for a lab-built magnetic system. The validity of the proposed model is illustrated by comparing the performances of the controller adopting the conventional model with that of the controller adopting the proposed model.

A New Algorithm of B-waveform Control for the Measurement of Two-dimensional Magnetic Properties of Electrical Steel Sheets using Single Sheet Tester (SST를 이용한 전기강판의 2차원 자기특성 측정을 위한 새로운 자속밀도 파형 제어법)

  • Eum, Young-Hwan;Yoon, Hee-Sung;Koh, Chang-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1167-1174
    • /
    • 2008
  • The measurement of two-dimensional magnetic properties of electrical steel sheet using single sheet tester (SST) requires to control the B-waveform as sinusoidal. The SST electric circuit, in general, has inductance, and this makes the phase lag in electric current. For this reason, the induced voltages of H- or B-coil may have phase difference from the exciting voltage. In this paper, a new algorithm is developed to compensate the phase difference and makes the B-waveform control efficient. The developed algorithm experimentally calculates the phase difference based on the measured waveform of the induced voltage for the magnetic field intensity along transverse direction. By using the proposed algorithm, the two-dimensional magnetic properties of grain-orientated electrical steel sheet (30PG110) is measured up to 2T. By comparing the measured B- and H-waveforms, the effectiveness of the proposed algorithm is proven.

Design of e-compass with terrestrial magnetic compensation for a ship (선박용 지자기 보정 기능을 갖는 이동식 전자컴퍼스 개발)

  • Hong, Chang-Hyun;Kim, Yung-Chul;Chong, Kil-To
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.381-382
    • /
    • 2007
  • Recently fishing industry is interested in efficient and automated fishing implementations to reach the level of the international leading technology. One of the important device used in fishing boat is an automated electric compass that harnesses the GPS and terrestrial magnetic sensor. The electric compass is desired to be minimized in size while keeping a high effectiveness in the characteristic of a magnetic compass. This device also can be used as a heading angle sensor to construct auto-navigation system in a small size of ships. However, there exists measurement errors induced from the slope of terrestrial magnetic sensor caused by the motion of boat. In this paper, a method has been proposed removing the measurement error arising from the slope of terrestrial magnetic sensor when the ship is in motion. We have designed a sensor with two DOF(degree of freedom) and a weight to maintain the horizontality of the sensor. Through this research, the hardware has been designed and also a test has been performed. The test shows a promissory result.

  • PDF