• 제목/요약/키워드: magnetic measurement

검색결과 1,248건 처리시간 0.032초

Design and Analysis of Lorentz Force-type Magnetic Bearing Based on High Precision and Low Power Consumption

  • Xu, Guofeng;Cai, Yuanwen;Ren, Yuan;Xin, Chaojun;Fan, Yahong;Hu, Dengliang
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.203-213
    • /
    • 2017
  • Magnetically suspended control & sensitive gyroscope (MSCSG) is a novel type of gyroscope with the integration of attitude control and attitude angular measurement. To improve the precision and reduce the power consumption of Lorentz Force-type Magnetic Bearing (LFMB), the air gap flux density distribution of LFMB has been studied. The uniformity of air gap flux density is defined to qualify the uniform degree of the air gap flux density distribution. Considering the consumption, the average value of flux density is defined as well. Some optimal designs and analyses of LFMB are carried out by finite element simulation. The strength of the permanent magnet is taken into consideration during the machining process. To verify the design and simulation, a high-precision instrument is employed to measure the 3-dimensional magnetic flux density of LFMB. After measurement and calculation, the uniform degree of magnetic flux density distribution reaches 0.978 and the average value of the flux density is 0.482T. Experimental results show that the optimal design is effective and some useful advice can be obtained for further research.

인덕턴스 측정에 의한 윤활유 내 자성입자 정량적 평가 (Monitoring Inductance Change to Quantitatively Analyze Magnetic Wear Debris in Lubricating Oil)

  • 구희조;안효석
    • Tribology and Lubricants
    • /
    • 제32권6호
    • /
    • pp.189-194
    • /
    • 2016
  • Wear debris in lubricating oil can be indicative of potential damage to mechanical parts in rotating and reciprocating machinery. Therefore, on-line or in-line monitoring of lubricating components in machinery is of great importance. This work presents a device based on inductive measurement of lubricating oil to detect magnetic wear particles in a tested volume. The circuit in the device consists of Maxwell Bridge and LVDT to measure inductance differences between pure and contaminated oil. The device detects the passage of ferrous particles by monitoring inductance change in a coil. The sensing principle is initially demonstrated at the microscale using a solenoid. The device is then tested using iron particles ranging from $50{\mu}m$ to $100{\mu}m$, which are often found in severely worn mechanical components. The test results show that the device is capable of detecting and distinguishing ferrous particles in lubricating oil. The design concept demonstrated here can be extended to an in-line monitoring device for real-time monitoring of ferrous debris particles. A simulation using the CST code is performed to better understand the inductive response in the presence of magnetic bodies in the oil. The CST simulation further verifies the effectiveness of inductance measurement for monitoring magnetic particles within a tube.

UKF를 사용한 AHRS의 자기장 측정 편차 추정 (Bias Estimation of Magnetic Field Measurement by AHRS Using UKF)

  • 고낙용;송경섭;정석기;이종무;최현택;문용선
    • 한국해양공학회지
    • /
    • 제31권2호
    • /
    • pp.177-182
    • /
    • 2017
  • This paper describes an unscented Kalman filter approach to estimate the bias in magnetic field measurements. A microelectromechanical systems attitude heading reference system (MEMS AHRS) was used to measure the magnetic field, together with the acceleration and angular rate. A magnetic field is usually used for yaw detection, while the acceleration serves to detect the roll and pitch. Magnetic field measurements are vulnerable to distortion due to hard-iron effect and soft-iron effect. The bias in the measurement accounts for the hard-iron effect, and this paper focuses on an approach to estimate this bias. The proposed method is compared with other methods through experiments that implement the navigation of an underwater robot using an AHRS and Doppler velocity log. The results verify that the compensation of the bias by the proposed method improves the navigation performance more than or comparable to the compensation by other methods.

YBa2Cu3O7-y 초전도 벌크의 중성자 조사 효과 (Neutron Irradiation Effect of YBa2Cu3O7-y Superconductor)

  • 이상헌
    • 한국전기전자재료학회논문지
    • /
    • 제34권6호
    • /
    • pp.438-441
    • /
    • 2021
  • The electrical characteristics of single-crystal composite superconductors produced by a melting process were studied by neutron irradiation. In order to improve the current characteristics of the YBa2Cu3O7-y superconductor, it is necessary to form an effective flux pinning center inside the superconductor. In this study, an increase in flux pinning was attempted through neutron irradiation onto YBa2Cu3O7-y superconductors. The neutron irradiation was performed at 30 MeV for 500 sec, The electrical properties of the superconductors were measured in a magnetic field of 5 Tesla at 50 K using a magnetic properties measurement system (MPMS). After neutron irradiation, the critical current density of the YBa2Cu3O7-y superconductor in a 1 Tesla magnetic field was 1×105 A/cm2. Once neutrons were irradiated at 30 MeV and 10 μA for 500 sec, the critical current density was observed to increase significantly. When neutrons are irradiated to a superconductor, micro-defects are created in the superconductor, and they act as flux pinning centers that hold the magnetic field generated when an electric current flows.

전력구 내 전자기파에 대한 작업 환경 측정 (The Measurement of Electromagnetic Wave in Power Cable Tunnel of Underground Utility Tunnel)

  • 강대곤;박재학
    • 한국안전학회지
    • /
    • 제34권1호
    • /
    • pp.1-7
    • /
    • 2019
  • Electromagnetic measurements of the power cable tunnel were conducted from August 10 to 20, 2018, in the ${\bigcirc}{\bigcirc}$ city underground utility tunnel. During this period, the average temperature was $31.89^{\circ}C$ and the humidity was 67.56% in power cable tunnel. As a result of the electromagnetic measurement, the highest electric field was 25.3 V/m and the magnetic flux density was $42.6{\mu}T$. The average electric field was 18.56 V/m and the magnetic flux density was $29.32{\mu}T$ in the power cable tunnel. As a result of comparison with the electric equipment technical standard, the electric field in the power cable tunnel was 0.5% of the electric equipment standard and 35.2% of the magnetic flux density. It's similar value that electric field is about robotic vacuum(15.53 V/m), and magnetic flux density is similar value about capsule- type coffee machine ($23.07{\mu}T$). The number of cable lines and the size of the electromagnetic waves were not proportional to each other through comparison of cable lines in the power cable tunnel. It was confirmed that 154 kV, rather than 22.9 kV, could have a greater influence on occupational.

플라스틱 자석 혼합물의 균질도 평가방법과 균질도가 자기특성에 미치는 영향 (Evaluation Methods of Homogeneity for Feedstocks and Effect of Homogeneity on the Magnetic Properties of Plastic Magnets)

  • 이석희;최준환;문탁진;정원용
    • 한국자기학회지
    • /
    • 제8권2호
    • /
    • pp.86-92
    • /
    • 1998
  • 플라스틱 자석에는 균일한 자장분포와 높은 자기특성을 얻기 위해서는 균질화된 혼합물이 요구되며, 이를 위해서는 적절한 혼합경로와 혼합물의 균질도 평가방법이 필수적이다. 본 연구에서는 Sr-ferrite/EVA 플라스틱 자석에서 혼합균질도의 평가방법과 혼합균질도가 자기특성에 미치는 영향을 조사하였다. 회분식 혼합기와 단축압출기를 이용하여 균질도가 서로 다른 혼합균질도를 조사하였다. 토크센서를 이요한 혼합시 토크변화 측정방법은 임계분말충전율 결정에는 효과적인데 반해 혼합균질도 평가에는 적합하지 않았다. 이그이방성 플라스틱 자석의 분말이방화율을 이용한 균질도 평가방법은 정밀도는 높으나, 시편제조와 측정에 고가의 장비와 필요하고 자성분말 혼합물 이외에는 이용될수 없다. 모세관 레오미터를 이용한 압출압력변화 측정방법은 정밀도가 높고 측정이 간편하여 효과적이었다. 혼합물의 균질도가 증가함에 따라 분말이방화율이 증가하였으며, 분말이방화율의 증가에 따라 잔류자속밀도는 직선적으로 증가하였다.

  • PDF

3축 자기검출소자를 이용한 아라호의 선내자계의 측정 (Measurement of the Ship`s Magnetic Field in M . S . ARA by Use of Three Axis Magnetic Detect Elements)

  • 안영화
    • 수산해양기술연구
    • /
    • 제31권4호
    • /
    • pp.385-392
    • /
    • 1995
  • The authors have been studying about and electro-magnetic compass with a three axis magnetic sensor in order to provide and accurate ship's magnetic heading which the compass deviations can automatically compensated in the compass itself, and the theory how to derive the poisson's coefficients from ship's magnetism measured with three axis magnetic sensor. This paper describes on the analysis of deviation derived from the measured values that obtained to measure the various magnetic fields at the compass position of the M. S. ARA, training ship of Cheju University with three axis magnetic sensor at Cheju near sea from 25th, Oct, to 13th, Nov. in 1994.

  • PDF

평등자계 형성용 전자석 자극 구조에 관한 연구 (Magnetic Pole Structure of Electro-Magnet for Forming Uniform Magnetic Field)

  • 김정태;이승면;조현준;김훈년
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.515-518
    • /
    • 2002
  • In this study, the ellipsoidal cap type magnetic pole structure was proposed for the electro-magnet in B-H curve tracer. From the simulation for the electro-magnet without specimen, the area of effective uniform field(99% range for the central field value) was considerably increased in case of the newly proposed ellipsoidal cap type magnetic pole than that of the conventional simple-inclined cap type magnetic pole. Also, through the simulation for the electro-magnet with permanent magnet specimen(NaFe30), the optimal Positions of the magnetic field measurement sensor(Hall sensor) were found out in each case and the errors were decreased in case of the newly proposed ellipsoidal cap type magnetic pole.

  • PDF

초고압 송전선로의 자계크기 해석과 실측 비교 (Analysis and Comparision of Measured and Calculated Value on Magnetic Fields Strength under Transmission Lines)

  • 조성배;이은웅
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권7호
    • /
    • pp.832-838
    • /
    • 1999
  • Recently, there are growing concerns about power frequency electric and magnetic fields coming out from the high voltage transmission lines, because of the wide spread perception of their probable harmful effect on human body. In connection with this trend, this paper describes the electric and magnetic fields measurement result around 154 kV and 345 kV transmission lines, a comparison of measured EMF to calculated one and the correlations between transmission lines currents and measured magnetic fields. Daily maximum and minimum magnetic field quantities under the selected 154 kV and 345 kV transmission lines had been measured for 1 year of 1997 and the average value of magnetic field exposure under the lines were calculated and presented based on the measured data.

  • PDF

The Effect of Cr doping on the Magnetic and Magnetocaloric Properties of MnCoGe Alloys

  • Emre, S. Yuce
    • Journal of Magnetics
    • /
    • 제18권4호
    • /
    • pp.405-411
    • /
    • 2013
  • The structural, magnetic and magnetocaloric properties of $CoMn_{1-x}Cr_xGe$ (x=0.05-0.125) have been investigated by using electron microscopy, x-ray diffraction, calorimetric and magnetic measurements. In this study, our aim is to justify the magnetocaloric effect by tuning the structural and magnetic transition temperature with Cr doping on CoMnGe pure system. The substitution of Cr for Mn leads to a decrease of both structural and magnetic transition temperatures. However, structural and magnetic transition temperatures do not close to each other. From magnetization measurement, we calculate that isothermal entropy change associated with magnetic transition can be as high as 3.82 J $kg^{-1}K^{-1}$ at 302 K in a field of 7 T. Meanwhile, structural phase transition contribution to isothermal entropy change is calculated as 5.85 J $kg^{-1}K^{-1}$ at 322 K for 7 T.