• 제목/요약/키워드: magnetic impact

검색결과 222건 처리시간 0.028초

An Investigation on Solution of Insecurity Sense Using a Music Performing Magnetic Resonance Imaging: Case report (자기공명영상 검사 시 음악을 이용하여 환자의 불안감 해소에 관한 고찰: 사례 보고)

  • Goo, Eun-Hoe;Kang, Soo-Cheol
    • Korean Journal of Digital Imaging in Medicine
    • /
    • 제11권2호
    • /
    • pp.59-62
    • /
    • 2009
  • The purpose of this study is to know about solution of insecurity sense for solving the tediousness and inducing comfortableness in long time MRI examination. Studies were examined with total of 117 patients that the intention expression of self is possible for a month without dividing man and woman in november 2006. Examination methods were filled in questionnaire after testing using Siemens Impact 1.0T. The musical art were selected through intranet search and record sale inquiry using CD player and speaker. That kind of a music were selected with Korean classical music's 10 chapter, pop song 10's chapter, classic's 10 chapter and Korean popular song's 10 chapter. With analytical method, patients of under 40 year-old, or older and patients using ear-pad and head-phone were classified into groups. As analysis result with question item of questionnaire, most of the patients were showed a favor(36.72%) in playing a music, specially, examination of about 15.38% which uses the headphone prefer a music as older generation of over 40 year-old. In conclusion, with installing of the professional musical program in MRI test rooms, if listening to the music with selection by oneself before testing by season, age, time through development of appropriate musical program will be able to expect the more effect.

  • PDF

Identification of Propentofylline Metabolites in Rats by Gas Chromatography/Mass Spectrometry

  • Kwon, Oh-Seung;Ryu, Jae-Chun
    • Archives of Pharmacal Research
    • /
    • 제23권4호
    • /
    • pp.374-380
    • /
    • 2000
  • Propentofylline (PPF, 3-methyl-1-(5-oxohexyl)-7-propylxanthine) has been reported to be a compound for treatment of both vascular dementia and dementia of the Alzheimer type. The short half-life (about 15 min) of PPF at the terminal elimination phase and poor bioavailability after oral administration of PPF to rabbits (Kim et al., 1992) suggest in part that this drug takes the extensive first-pass metabolism in the liver. In addition, the metabolic pathway for PPF remains unclear. The objective of this experiment is to identify urinary metabolites of PPF in rats. For the identification of the metabolites, rat urine was collected after oral administration of 100${m}g/kg$ PPF. PPF metabolite, 3-methyl-1-(5-hydroxyhexyl)-7-propylxanthine, was synthesized and confirmed by gas chromatography/mass spectroscopy (GC/MS) and $^1H$ nuclear magnetic resonance spectroscopy. The urinary metabolites of PPF were extracted with diethyl ether and identified by electron impact and chemical ionization GC/MS. One urinary metabolite was confirmed to be 3-methyl-1-(5-hydroxyhexyl)-7-propylxanthine by synthesized authentic compound. Several metabolites of monohydroxy- and dihydroxy-PPF were identified based on mass fragmentation of both intact and trimethylsilylated derivatives of PPF metabolites and the novel structure of these metabolites is suggested based on mass spectra.

  • PDF

Impact of Amino-Acid Coating on the Synthesis and Characteristics of Iron-Oxide Nanoparticles (IONs)

  • Ebrahiminezhad, Alireza;Ghasemi, Younes;Rasoul-Amini, Sara;Barar, Jaleh;Davaran, Soodabeh
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권12호
    • /
    • pp.3957-3962
    • /
    • 2012
  • Iron-oxide nanoparticles (IONs) with biocompatible coatings are the only nanostructural materials which have been approved by the FDA for clinical use. Common biocompatible coatings such as hydrocarbons, polymers, and silica have profound influences on critical characteristics of IONs. Recently, amino acids were introduced as a novel biocompatible coating. In the present study, the effects of amino acids on IONs synthesis and characteristics have been evaluated. Magnetite nanoparticles with L-arginine and L-lysine coatings were synthesised by a coprecipitation reaction in aqueous solvent and their characteristics were compared with naked magnetite nanoparticles. The results showed that amino acids can be a perfect coating for IONs and would increase particle stability without any significant effects on the critical properties of nanoparticles such as particle size and magnetization saturation value.

A Novel Dual-Input Boost-Buck Converter with Coupled Inductors for Distributed Thermoelectric Generation Systems

  • Zhang, Junjun;Wu, Hongfei;Sun, Kai;Xing, Yan;Cao, Feng
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.899-909
    • /
    • 2015
  • A dual-input boost-buck converter with coupled inductors (DIBBC-CI) is proposed as a thermoelectric generator (TEG) power conditioner with a wide input voltage range. The DIBBC-CI is built by cascading two boost cells and a buck cell with shared inverse coupled filter inductors. Low current ripple on both sides of the TEG and the battery are achieved. Reduced size and power losses of the filter inductors are benefited from the DC magnetic flux cancellation in the inductor core, leading to high efficiency and high power density. The operational principle, impact of coupled inductors, and design considerations for the proposed converter are analyzed in detail. Distributed maximum power point tracking, battery charging, and output control are implemented using a competitive logic to ensure seamless switching among operational modes. Both the simulation and experimental results verify the feasibility of the proposed topology and control.

Sliding Mode Control for Improving Performance of Mount with MR(Magneto-Rheological) Fluid (MR마운트 진동제어 성능 향상을 위한 슬라이딩 모드 제어)

  • Ahn, Young Kong;Kim, Sung-Ha;Jeong, Seok-Kwon
    • Journal of Power System Engineering
    • /
    • 제21권4호
    • /
    • pp.18-25
    • /
    • 2017
  • This paper deals with vibration control of a small mount with MR(Magneto-Rheological) fluid as a functional fluid mount for precision equipment of automobiles. Damping and stiffness coefficients of the mount with MR fluid are changed by variations of the applied magnetic field strength. We present the robust control scheme, based on a conventional sliding mode control theory, for the design of a stable controller that is capable of vibration control due to various disturbances such as impact and periodic excitations, and is insensitive to dynamic properties of the mount. We got stable controller by using Lyapunov stability theory. The controller is then realized by using a semi-active control condition in simulations. Chattering problem of the sliding mode control is eliminated by saturation function instead of signum function. The sliding mode control with Lyapunov stability theory is superior to passive and Sky-Hook control in performance.

Clinical impact of cerebral microbleeds on cognition in patients with CADASIL

  • Lee, Jung Seok;Ko, Keun Hyuk;Oh, Jung-Hwan;Choi, Jay Chol;Kim, Joong-Goo
    • Journal of Medicine and Life Science
    • /
    • 제15권2호
    • /
    • pp.89-94
    • /
    • 2018
  • Cerebral autosomal-dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL) is inherited microangiopathy caused by mutations in the Notch3 gene. Typical findings from brain magnetic resonance imaging (MRI) include subcortical lacunes, extensive white matter change and cerebral microbleeds(CMBs). CMBs are indicative of bleeding-prone microangiopathy. Despite some studies investigating the association between lacunes and cognitive dysfunction in CADASIL, few studies have examined the relationship between cognitive dysfunction and CMBs. We sought to assess whether CMBs are associated with cognitive dysfunction in CADASIL. This study enrolled 83 consecutive patients with CADASIL between April 2012 and January 2014. Their degree of cognitive dysfunction was assessed by the Korean version of the CERAD neuropsychological assessment battery, digit span test, and the Stroop test. A 3.0-T MRI was used to obtain T1-weighted, fluid-attenuated inversion recovery, and susceptibility weighted images. In multiple logistic regression analysis, the grade of CMBs influenced tests of memory dysfunction (p=0.003). Three or more lacunes correlated with dysfunction in the executive domain (p=0.013) and attention domain (p=0.005). White matter hyperintensity (WMH) was an independent predictor of executive dysfunction (p=0.001). These findings suggest that in addition to lacunes, CMBs and WMHs may be useful imaging markers to associated with cognitive dysfunction in CADASIL.

Performance Evaluation of Microchip Removal Device Rotating by Conveyor Belt with Neodymium Permanent Magnet (네오디뮴 영구자석을 이용한 컨베이어벨트 구동형 미세칩 포집장치의 성능 평가)

  • Choi, Sung-Yun;Wang, Jun-hyeong;Wang, Duck Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • 제20권1호
    • /
    • pp.103-109
    • /
    • 2021
  • Fine chips generated by machining have an impact on machine failure and quality of machined products, it is necessary to remove the chips, so the microchip collection and removal device by rotating conveyor belt with neodymium permanent magnets was developed. In this research, to solve the problem for reducing the existing microchips in the tank, a micro-chip removal device by rotating conveyor belt with neodymium permanent magnets developed. In the development of micro-chip removal device, 3D CATIA modeling was used, and the flow analysis and the electromagnetic force analysis were performed with COMSOL Multiphysics program. To evaluate the performance of the prototypes produced, design of experiments (DOE) is used to obtain the effect of neodymium conveyor movement speed on chip removal for the ANOVA analysis of recovered powders. An experiment was conducted to investigate the effect of the conveyor feed rate on the chip removal performance in detail. As a result of the experiment, it was confirmed that the slower the feeding speed of the fine chip removing device, the more efficient the chip removal.

Effect of myoglobin, hemin, and ferric iron on quality of chicken breast meat

  • Zhang, Muhan;Yan, Weili;Wang, Daoying;Xu, Weimin
    • Animal Bioscience
    • /
    • 제34권8호
    • /
    • pp.1382-1391
    • /
    • 2021
  • Objective: The objective was to evaluate the impact of different forms of iron including myoglobin, hemin, and ferric chloride on the quality of chicken breast meat. Methods: Chicken breast muscles were subjected to 1, 2, 3 mg/mL of FeCl3, myoglobin and hemin treatment respectively, and the production of reactive oxygen species (ROS) and malondialdehyde, meat color, tenderness, water holding capacity and morphology of meat was evaluated. Results: Hemin was found to produce more ROS and induce greater extent of lipid oxidation than myoglobin and ferric chloride. However, it showed that hemin could significantly increase the redness and decrease the lightness of the muscle. Hemin was also shown to be prominent in improving water holding capacity of meat, maintaining a relatively higher level of the immobilized water from low-field nuclear magnetic resonance measurements. Morphology observation by hematoxylin-eosin staining further confirmed the results that hemin preserved the integrity of the muscle. Conclusion: The results indicated that hemin may have economic benefit for the industry based on its advantage in improving water holding capacity and quality of meat.

Functional Anatomy of the Temporomandibular Joint and Pathologic Changes in Temporomandibular Disease Progression: A Narrative Review

  • Yeon-Hee Lee
    • Journal of Korean Dental Science
    • /
    • 제17권1호
    • /
    • pp.14-35
    • /
    • 2024
  • The temporomandibular joint (TMJ) is one of the most unique joints in the human body that orchestrates complex movements across different orthogonal planes and multiple axes of rotation. Comprising the articular eminence of the temporal bone and the condylar process of the mandible, the TMJ integrates five major ligaments, retrodiscal tissues, nerves, and blood and lymph systems to facilitate its function. Cooperation between the contralateral TMJ and masticatory muscles is essential for coordinated serial dynamic functions. During mouth opening, the TMJ exhibits a hinge movement, followed by gliding. The health of the masticatory system, which is intricately linked to chewing, energy intake, and communication, has become increasingly crucial with advancing age, exerting an impact on oral and systemic health and overall quality of life. For individuals to lead a healthy and pain-free life, a comprehensive understanding of the basic anatomy and functional aspects of the TMJ and masticatory muscles is imperative. Temporomandibular disorders (TMDs) encompass a spectrum of diseases and disorders associated with changes in the structure, function, or physiology of the TMJ and masticatory system. Functional and pathological alterations in the TMJ and masticatory muscles can be visualized using various imaging modalities, such as cone-beam computed tomography, magnetic resonance imaging, and bone scans. An exploration of potential pathophysiological mechanisms related to the TMJ anatomy contributes to a comprehensive understanding of TMD and informs targeted treatment strategies. Hence, this narrative review presents insights into the fundamental functional anatomy of the TMJ and pathological changes that evolve with TMD progression.

Evaluation of Extremely Low Frequency Magnetic Fields emission Level from High Voltage Transmission Lines (고압 송전선로에서 극저주파 자기장 영향평가 적용에 관한 연구)

  • Jung, Joon Sig;Choi, Sung Ho;Jeon, Hyung Jin;Kim, Yoon Shin;Hong, Seung Cheol
    • Journal of Environmental Impact Assessment
    • /
    • 제23권5호
    • /
    • pp.353-363
    • /
    • 2014
  • The purpose of this study was to investigated the ELF-MF emission level of various environments such as 258 facilities near located to high voltage transmission lines and 120 high voltage transmission lines, 17 underground cable lines. In addition, ELF-MF reduction rate according to separation distance was calculated by using simulations. An appropriate separation distance showing below 4mG was at least 70m. In the case of the appropriate separation distance for 120 high voltage transmission lines, 154kV required 20m of separation distance and 345kV required 60m of separation distance. The simulation results showed that the appropriate separation distance showing below 4mG was 40m and 60m for overhead 154kV and 345kV respectively. To adjust the worst conditions considering the aspects of environmental impact assessment study and the electric power currents that will increase in the future, the appropriate minimum separation distance for HVTL is judged to be above 70m in this study. Thus, there is a need to establish the greenbelt or buffer zone within 70m so as to create an environment in which the receptors are not exposed and thereby eliminate the risk factors of ELF-MF against humans.