• 제목/요약/키워드: magnetic field measurement

검색결과 517건 처리시간 0.024초

초고압 송전선로의 자계크기 해석과 실측 비교 (Analysis and Comparision of Measured and Calculated Value on Magnetic Fields Strength under Transmission Lines)

  • 조성배;이은웅
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권7호
    • /
    • pp.832-838
    • /
    • 1999
  • Recently, there are growing concerns about power frequency electric and magnetic fields coming out from the high voltage transmission lines, because of the wide spread perception of their probable harmful effect on human body. In connection with this trend, this paper describes the electric and magnetic fields measurement result around 154 kV and 345 kV transmission lines, a comparison of measured EMF to calculated one and the correlations between transmission lines currents and measured magnetic fields. Daily maximum and minimum magnetic field quantities under the selected 154 kV and 345 kV transmission lines had been measured for 1 year of 1997 and the average value of magnetic field exposure under the lines were calculated and presented based on the measured data.

  • PDF

가정용 전기기구에서 발생하는 자장과 유도전압의 측정과 분석 (Measurement and Analysis of Magnetic Fields and Induced Voltages Caused by Home Appliances)

  • 이복희;이동문;장영태;장근철;엄주홍;강성만;이승칠;박정용
    • 조명전기설비학회논문지
    • /
    • 제16권6호
    • /
    • pp.51-59
    • /
    • 2002
  • 논문은 가전기구의 사용으로 발생하는 유도전압 및 자장의 측정과 분석에 대한 것으로 본 실험에 사용한 유도전압과 자장 측정회로는 유도코일, 선행증폭기, 그리고 능동적분기로 구성하였다. TV와 퍼스널 컴퓨터용 모니터는 스위칭소자로 동작하는 전원장치를 사용하므로 고조파 성분을 많이 포함하는 강한 자장과 유도전압을 발생시켰다. 14"TV 주변에서 큰 자장과 높은 유도전압이 나타났고, 그 값은 측정거리 0.4 [m]에서 각각 2.1 [$\mu$Tp-p]와 140[mVp-p]이었다. 그러나 동일한 측정거리에서 단위 자장의 세기에 대한 유도전압은 17"모니터에서 약560 [mV/$\mu$T]로 가장 크게 나타났다.장 크게 나타났다.

환상 루-프 안테나를 이용한 자기장 세기의 측정 (Magnetic Field Strength Measurement using Circular Loop Antenna)

  • 박병권;강찬구;김정환
    • 한국통신학회논문지
    • /
    • 제16권6호
    • /
    • pp.566-573
    • /
    • 1991
  • 자기장 세기의 측정능력을 고찰하기 위하여 표준 자기장법으로 측정한 자기장의 세기와 표준 안테나법으로 측정한 자기장의 세기를 비교하여 보았으며, 이 결과 두 방법으로 측정한 자기장의 세기가 오차범위내에서 잘 일치함을 알 수 있었다. 또한 본 연구를 통하여 자기장 측정용 안테나 및 자기장 세기 측정기의 교정을 10KHz~30MHz의 주파수 범위에서 약 1dB의 오차내에서 가능함을 확인할 수 있었다.

  • PDF

비정질 리본의 자기장중 열처리에 의한 보자력 노이즈의 변화에 관한 연구 (Study on the Coercive Field Strenght Noise Depends on The Magnetic Field Annealing Effect of Amorphous Ribbon)

  • 최근화;손대락
    • 한국자기학회지
    • /
    • 제4권2호
    • /
    • pp.150-153
    • /
    • 1994
  • 본 연구에서는 2쌍의 헬름홀쯔코일을 사용하여 비본형 시편의 종방향 및 횡방향으로 자기장 을 인가한 상태에서 열처리한 Co-계 비정질 합금 VITROVAC 6030의 보자력 노이즈를 측정하였다. 시편의 종방향 및 횡방향으로 dc 자기장을 인가한 상태에서 열처리한 시편의 경우, 보자력노이즈는 자화주파수 가 1~100 kHz 범위에서 거의 변화하지 않았으며, 시편의 종방향으로 ac 자기장을 횡방향으로는 dc자기 장을 인가한 상태에서 열처리한 시편의 경우의 보자력 노이즈는 자화주파수의 거듭제곱으로 감소하는 경 향을 보였다. 또한 자구핵형성이 일어날 경우 보자력 노이즈는 크게 증가하며 자화주파수의 거듭제곱으 로 감소하는 경향을 보였다.

  • PDF

마이크로컴퓨터를 이용한 자체 보상형 flux-gate 마그네토미터제작 (Self Compensating Flux-gate Magnetometer Using Microcomputer)

  • 가은미;손대락;손동환
    • 한국자기학회지
    • /
    • 제12권4호
    • /
    • pp.149-153
    • /
    • 2002
  • 지구자기장 이하의 저자기장 측정에 있어서 소형이고 소비전력이 작으면서 장기적 안정성이 요구되는 분야에 flux-gate 마그네토미터를 많이 사용하고 있다. 또한 많은 저자기장 측정분야가 지구자기장의 크기측정보다는 지자장의 변화를 측정하는 경우가 많기 때문에, 본 연구에서 측정범위가 $\pm$1,000 nT, 5pT/√Hz (at 1 Hz)인 flux-gate센서를 사용 $\pm$50000 nT인 지구자기장을 순차적 근사법으로 보상한 후 지구자기장의 변화를 고감도로 측정할 수 있는 3-축의 flux-gate 마그네토미터를 개발하였다.

Silicon Matrix MRE 의 인가자기장에 따른 전단계수 증가율 측정 (Measurement of Shear Modulus Increment Ratio of Magneto-rheological Elastomer based on Silicon Matrix due to Induced Magnetic field)

  • 오재응;노정준;이선훈;김진수;정운창
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.288-291
    • /
    • 2014
  • MRE(Magneto-rheological Elastomer) is a material which shows reversible and various modulus in magnetic field. Comparing to conventional rubber vibration isolator, MREs are able to absorb broader frequency range of vibration. These characteristic phenomena result from the orientation of magnetic particle (i.e., chain-like formation) in rubber matrix. In this study, Silicon was used as a matrix in order to manufacture MREs. Magnetic reactive powder(MRP), having rapid magnetic reaction, was selected as a magnetic particle to give magnetic field reactive modulus. The mechanical properties of manufactured MREs were measured with the application of magnetic field. The analysis of MR effect was carried out by FFT analyzer with various induced magnetic field. As the addition of CIP and induced magnetic field intensity increased, increment of MR effect was observed.

  • PDF

Near-field Noise-emission Modeling for Monitoring Multimedia Operations in Mobile Devices

  • Song, Eakhwan;Choi, Jieun;Lee, Young-Jun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제5권6호
    • /
    • pp.440-444
    • /
    • 2016
  • In this paper, an equivalent circuit model for near-field noise emission is proposed to implement a multimedia operation-monitoring system for mobile devices. The proposed model includes a magnetic field probe that captures noise emissions from multimedia components, and a transfer function for near-field noise coupling from a transmission line source to a magnetic field probe. The proposed model was empirically verified with transfer function measurements of near-field noise emissions from 10 kHz to 500 MHz. With the proposed model, a magnetic field probe was optimally designed for noise measurement on a camera module and an audio codec in a mobile device. It was demonstrated that the probe successfully captured the near-field noise emissions, depending on the operating conditions of the multimedia components, with enhanced sensitivity from a conventional reference probe.

22.9[kV] 배전선로 주변의 전장과 자장의 분포 (Profiles of electric and magnetic fields in the vicinity of 22.9[kV] Distribution Line)

  • 이복희;길형준;안창환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1653-1655
    • /
    • 1998
  • In this paper, measurement and analysis of ELF electric and magnetic fields in the vicinity of 22.9[kV] distribution line have been performed. The height of measuring point from the earth's surface was 1[m], and the distance between the device and the operator was more than 3[m]. The experiments have been carried out by lateral profile, and we have made use of FIELDS program for the sake of comparision the experimental data with the theoretical value. Electric and magnetic fields intensity were strong under a distribution line, and were inversely proportional to lateral distance. The profiles of electric field were M shape and those of magnetic field were $\cap$ shape. Electric and magnetic fields intensity were increased with increasing the measurement height.

  • PDF

자화된 플라즈마 내에서의 단분산 입자의 하전량 특정 (Measurement of Monodisperse Particle Charging in Unmagnetized and Magnetized Plasmas)

  • 한장식;안강호;김곤호
    • 반도체디스플레이기술학회지
    • /
    • 제1권1호
    • /
    • pp.35-40
    • /
    • 2002
  • Understanding of charging properties of a small particle is necessary to control the particle contamination and to improve productivity of the electronic device in the plasma aided semiconductor manufacturing processes. In this study, the effects of both magnetic field and particle size on the charging properties are experimentally investigated in collisional dusty plasmas. The experiments carried out in the system consisted of a monodisperse particle generation system, a DC magnetized plasma generation system and a charge measurement system. The plasma chamber is made of cross-shape Pyrex surrounded by magnetic bucket (composed of 12 permanent magnetic bar) to confine the plasma. DC magnetic field up to 250G are applied to the plasma zone by external magnetic coil. Previous work shows the charging effect clearly increase with increasing the size of the particle and plasma density, as it was expected.

  • PDF

전기기구의 운전중에 발생되는 자계성분해석에 관한 연구 (A Study on the Analysis of the Magnetic Fields Generated by the operation of Electric Appliances)

  • 이복희;박형기;정승수;백용현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.575-577
    • /
    • 1993
  • In this study, the reponse characteristic of the time-changing magnetic field measurement system by using the self-integrated magnetic sensor is investigated. The measurement system has the frequency bandwidth of 40[Hz]-50[kHz]. The time-changing magnetic fields generated by the operations of small-size electric machines are investigated. The magnetic field generated by the starting and/or the operation of electric appliances mainly includes the odd harmonics such as the third, the fifth, the seventh, and so on.

  • PDF