• Title/Summary/Keyword: magnetic curve

Search Result 445, Processing Time 0.029 seconds

Static Characteristics Investigation of LPM According to Input Current Waveforms (입력 전류 파형에 따른 LPM의 정특성 고찰)

  • 허두석;조윤현
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.7
    • /
    • pp.409-416
    • /
    • 2004
  • This paper presents the selection method o( the input current wave forms for the thrust force ripple of linear pulse motor (LPM). We have developed and tested a prototype 2-phase 4-poles LPM with the permanent magnet and its control driver. To obtain the thrust performance curve of LPM, the performance curve at the air gap and the thrust are calculated and estimated by the analytical method on the base of the magnetic equivalent circuit and the finite element method. And, the thrust characteristics at the static operation state are analyzed and experimented with the respect to the input wave forms such as the rectangular, the triangular micro-step and the sine micro-step wave forms to investigate the thrust ripple and the vibration effects of LPM.

Analytical Formulation for the Everett Function

  • Hong, Sun-Ki;Kim, Hong-Kyu;Jung, Hyun-Kyo
    • Journal of Magnetics
    • /
    • v.2 no.3
    • /
    • pp.105-109
    • /
    • 1997
  • The Preisach model neds a density function or Everett function for the hysterisis operator to simulate the hysteresis phenomena. To obtain the function, many experimental data for the first order transition curves are required. However, it needs so much efforts to measure the curves, especially for the hard magnetic materials. By the way, it is well known that the density function has the Gaussian distribution for the interaction axis on the Preisach plane. In this paper, we propose a simple technique to determine the distribution function or Everett function analytically. The initial magnetization curve is used for the distribution of the Everett function for the coercivity axis. A major, minor loop and the initial curve are used to get the Everett function for the interaction axis using the Gaussian distribution function and acceptable results were obtained.

  • PDF

Analytical Estimation of Inductance at Aligned and Unaligned Rotor Positions in a Switched Reluctance Motor (스위치드 릴럭턴스 전동기의 회전자 정렬과 비정렬 위치에서의 인덕턴스 예측)

  • Lee, Chee-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.34-40
    • /
    • 2012
  • Flux linkage of phase windings or phase inductance is an important parameter in determining the behavior of a switched reluctance motor (SRM) [1-8]. Therefore, the accurate prediction of inductance at aligned and unaligned rotor positions makes a significant contribution to the design of an SRM and its analytical approach is not straightforward due to nonlinear flux distribution. Although several different approaches using a finite element analysis (FEA) or curve-fitting tool have been employed to compute phase inductance [2-5], they are not suitable for a simple design procedure because the FEA necessitates a large amount of time in both modeling and solving with complexity for every motor design, and the curve-fitting requires the data of flux linkage from either an experimental test or an FEA simulation. In this paper, phase inductance at aligned and unaligned rotor positions is estimated by means of numerical method and magnetic equivalent circuit as well, and the proposed approach is analytically verified in terms of the accuracy of estimated inductance compared to inductance computed by an FEA simulation.

Design of PDP driving waveform for the addressing problem with wide screen driving (대화면 구동에 따른 데이터 기입 문제 해결을 위한 PDP 구동파형 설계)

  • O, Sun-Taek;Kim, Jun-Hyeong;Lee, Dong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.848-851
    • /
    • 2003
  • Display devices are becoming increasingly important as an interface between humans and machines in the growing information society In display device, PDP(Plasma Display Panel) has many advantages in that wide screen, light weight, thin, wide viewing angle and unaffected by magnetic field. In this paper, modified ramp waveform is suggested by Vt Close Curve, and PDP driving circuit is designed by modified ramp waveform, this modified ramp waveform have more addressing wall voltage better then the old ramp waveform.

  • PDF

Analysis of Flexible Media Behavior by Dynamic Elastica (Dynamic Elastica에 의한 유연매체의 거동해석)

  • Hong, Sung-Kwon;Jee, Jung-Geun;Jang, Yong-Hoon;Park, No-Cheol;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.600-605
    • /
    • 2004
  • In many machines handling lightweight and flexible media such as magnetic tape drives, xerographic copiers and sewing machines, the media must transit an open space. It is important to predict the static and dynamic behavior of the sheets with a high degree of reliability. The nonlinear theory of the dynamic elastica has often been used to a nonlinear dynamic deflection model. In this paper, the governing equation is derived and simulated by the finite differential method. The parametric cubic curve is applied for defining the guide shape. The dynamic contact conditions suggested by Klarbring is used to predict the direction of the flexible media according to the initial velocity and the friction coefficient. The analysis is also compared to the conventional model, showing that after contacting a $45^{\circ}$ wall, the directions of flexible media of two models are different.

  • PDF

Observation of Water Level and Temperature Properties by using a Giant Magnetoresistance-Spin Valve Film

  • Choi, Jong-Gu;Park, Kwang-Jun;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.17 no.3
    • /
    • pp.214-218
    • /
    • 2012
  • The water level and temperature properties for the cooling system of potassium titanyl phosphate laser systems were observed. The middle point of the GMR-SV magnetoresistance curve is set in the neighborhood of high magnetic sensitivity (2.8 %/Oe). The experimental results for resistance dependence on water height and temperature showed linear regions with rates of 0.4 ${\Omega}/mm$ and 0.1 ${\Omega}/^{\circ}C$, respectively. The proposed results were found to be for adjusting the water level and temperature in the laser cooling system.

Dry Magnetic Particle Inspection of Ingot Cast Billets (강편 빌레트의 건식 자분 탐상)

  • Kim, Goo-Hwa;Lim, Zhong-Soo;Lee, Eui-Wan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.3
    • /
    • pp.162-173
    • /
    • 1996
  • Dry magnetic particle inspection(MPI) was performed to detect the surface defects of steel ingot cast billets. Magnetic properties of several materials were characterized by the measurement of the B-H hysteresis curve. The inspection results were evaluated in terms of the magnetizing current, temperature, and the amount of magnetic particles applied to billets. Magnetic flux leakage near the defect site of interest was measured and compared with the results of calculation by the finite element method in the case of direct magnetizing current. Direct and alternating magnetizing currents for materials were deduced by the comparison of the inspections. Results of the magnetic particle inspection by direct magnetizing current were compared with those of finite element method calculations, which were verified by measuring magnetic leakage flux above the surface and the surface defects of the material. For square rods, due to the geometrical effect, the magnetic flux density at the edges along the length of the rods was about 30% of that at the center of rod face for a sufficiently large direct magnetizing current, while it was about 70% for an alternating magnetizing current. Thus, an alternating magnetizing current generates rather uniform magnetic flux density over the rods, except for the region on the face across about 10 mm from the edge. The attraction of the magnetic particle by the magnetic leakage field was nearly independent of the surface temperature of the billets up to $150^{\circ}C$. However, the temperature should have been limited below $60^{\circ}C$ for an effective fixing of gathered magnetic particles to the billet surface using methylene chloride. We also found that the amount of applied magnetic particles tremendously affected the detection capability.

  • PDF

Quantification of Cerebral Blood Flow Measurements by Magnetic Resonance Imaging Bolus Tracking

  • Park Byung-Rae
    • Biomedical Science Letters
    • /
    • v.11 no.2
    • /
    • pp.129-134
    • /
    • 2005
  • Three different deconvolution techniques for quantifying cerebral blood flow (CBF) from whole brain $T2^{\ast}-weighted$ bolus tracking images were implemented (parametric Fourier transform P-FT, parametric single value decomposition P-SVD and nonparametric single value decomposition NP-SVD). The techniques were tested on 206 regions from 38 hyperacute stroke patients. In the P-FT and P-SVD techniques, the tissue and arterial concentration time curves were fit to a gamma variate function and the resulting CBF values correlated very well $(CBF_{P-FT}\;=\;1.02{\cdot}CBF_{p-SVD},\;r^2\;=\;0.96)$. The NP-SVD CBF values correlated well with the P-FT CBF values only when a sufficient number of time series volumes were acquired to minimize tracer time curve truncation $(CBF_{P-FT}\;=\;0.92{\cdot}CBF_{NP-SVD},\;r^2\;=\;0.88)$. The correlation between the fitted CBV and the unfitted CBV values was also maximized in regions with minimal tracer time curve truncation $(CBV_{fit}\;=\;1.00{\cdot}CBV_{ Unfit},\;^r^2\;=\;0.89)$. When a sufficient number of time series volumes could not be acquired (due to scanner limitations) to avoid tracer time curve truncation, the P-FT and P-SVD techniques gave more reliable estimates of CBF than the NP-SVD technique.

  • PDF

Development and Validation of a Screening Questionnaire for Dementia With Lewy Bodies (DLB): the DLB Screening Questionnaire (DLBSQ)

  • Mincheol Park;Kyoungwon Baik;Young H. Sohn;Byoung Seok Ye
    • Dementia and Neurocognitive Disorders
    • /
    • v.23 no.1
    • /
    • pp.11-21
    • /
    • 2024
  • Background and Purpose: Although dementia with Lewy bodies (DLB) is the second most common cause of neurodegenerative dementia, its clinical prevalence is low. We developed a short and easy-to-complete DLB screening questionnaire (DLBSQ) to raise diagnostic sensitivity in routine clinical settings. Methods: A total of 501 participants were retrospectively enrolled, including 71 controls, 184 patients without DLB, and 246 patients with probable DLB. All patients underwent clinical evaluation, including core features of DLB, the DLBSQ, brain magnetic resonance imaging, and detailed neuropsychological assessments. The diagnostic performance of the DLBSQ for probable DLB was investigated using a receiver operating characteristic curve analysis. Results: Total DLBSQ score was associated with visuospatial and frontal/executive dysfunction and the diagnosis of probable DLB. The area under the receiver operating characteristic curve for total DLBSQ score was 0.727. Youden's method revealed an optimal cutoff value of 3. The sensitivity and specificity of the DLBSQ were 68.7% and 62.4%, respectively. Its discriminating performance improved when cognitive test profiles were additionally considered (area under the curve: 0.822, sensitivity: 80.6%, and specificity: 70.4%). Conclusions: The DLBSQ might be a useful screening tool for DLB in routine clinical practice with good sensitivity and specificity.

The role of the iliotibial band cross-sectional area as a morphological parameter of the iliotibial band friction syndrome: a retrospective pilot study

  • Park, Jiyeon;Cho, Hyung Rae;Kang, Keum Nae;Choi, Kun Woong;Choi, Young Soon;Jeong, Hye-Won;Yi, Jungmin;Kim, Young Uk
    • The Korean Journal of Pain
    • /
    • v.34 no.2
    • /
    • pp.229-233
    • /
    • 2021
  • Background: Iliotibial band friction syndrome (ITBFS) is a common disorder of the lateral knee. Previous research has reported that the iliotibial band (ITB) thickness (ITBT) is correlated with ITBFS, and ITBT has been considered to be a key morphologic parameter of ITBFS. However, the thickness is different from inflammatory hypertrophy. Thus, we made the ITB cross-sectional area (ITBCSA) a new morphological parameter to assess ITBFS. Methods: Forty-three patients with ITBFS group and from 43 normal group who underwent T1W magnetic resonance imaging were enrolled. The ITBCSA was measured as the cross-sectional area of the ITB that was most hypertrophied in the magnetic resonance axial images. The ITBT was measured as the thickest site of ITB. Results: The mean ITBCSA was 25.24 ± 6.59 ㎟ in the normal group and 38.75 ± 9.11 ㎟ in the ITBFS group. The mean ITBT was 1.94 ± 0.41 mm in the normal group and 2.62 ± 0.46 mm in the ITBFS group. Patients in ITBFS group had significantly higher ITBCSA (P < 0.001) and ITBT (P < 0.001) than the normal group. A receiver operator characteristic curve analysis demonstrated that the best cut-off value of the ITBT was 2.29 mm, with 76.7% sensitivity, 79.1% specificity, and area under the curve (AUC) 0.88. The optimal cut-off score of the ITBCSA was 30.66 ㎟, with 79.1% sensitivity, 79.1% specificity, and AUC 0.87. Conclusions: ITBCSA is a new and sensitive morphological parameter for diagnosing ITBFS, and may even be more accurate than ITBT.