The Sensorless Control of PMSM Using the Coordinate Transform and Differential Method (좌표 변환과 미분 기법을 이용한 PMSM의 센서리스 제어)

  • Choi, Chul;Won, Tae-Hyun;Park, Sung-Jun;Park, Han-Woong;Kim, Chul-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.107-115
    • /
    • 2003
  • PMSM(permanent magnet synchronous motor) are widely used in industrial and home appliance because of their high torque to inertia ratio, superior power density, and high efficiency For the high control performance, accurate information of rotor position Is essential. In recent, sensorless algorithms are much studied due to high cost problem of position sensor and low reliability in harsh environment. In the proposed method, a differential linkage flux is used for the estimation of rotor position. The differential magnetic field flux is calculated by the voltage equations and measured phase current without any integration and differential calculus. Instead of linkage flux calculation with differential operation, a new mathematical differential method is introduced by a-$\beta$ transformation. The proposed novel position sensorless speed control scheme is verified through experimental results.

Fuzzy Simulation of a Multi-electronic Acupuncture System and Clip-type Pulsimeter Equipped with a Magnetic Sensing Hall Device

  • Hong, You-Sik;Rhee, Jin-Kyu;Kim, Han-Kyu;Son, Il-Ho;Yoon, Woo-Sung;Lee, Nam-Kyu;Park, Do-Young;Kim, Keun-Ho;Kim, Yong-Jin;Khajidmaa, P.;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.255-260
    • /
    • 2014
  • A portable clip-type pulsimeter equipped with a magnetic sensing Hall device has been developed to raise the accuracy of oriental disease diagnosis and therapy by convergence of magnetism and oriental medicine. To improve accuracy and reliability of conventional pulsimeter due to subjective analysis of the pulse wave and measuring position dependency of the arterial pulse sensor, the fuzzy algorithm was applied to analyze the strong- and weak-pulse wave symptom. Optimal time for electronic acupuncture was calculated using fuzzy rules and interference were drawn from objective data in view of pre-treatment. Moreover, the electrical characteristics of the pain parts that respond to acupuncture point were applied in view of post-treatment to propose the scientific pulse wave algorithm and simulation experiment.

Experimental Evaluation of Superconductor Flywheel Energy Storage System with Hybrid Type Active Magnetic Bearing (하이브리드 AMB를 포함한 초전도 플라이휠 에너지 저장장치의 실험평가)

  • Lee, J.P.;Kim, H.G.;Han, S.C.
    • Progress in Superconductivity
    • /
    • v.13 no.3
    • /
    • pp.195-202
    • /
    • 2012
  • In this paper, we designed Active Magnetic Bearing (AMB) for large scale Superconductor Flywheel Energy Storage System (SFESS) and PD controller for AMB. And we experimentally evaluated SFESS including hybrid type AMB. The radial AMB was designed to provide force slew rate that was sufficient for the unbalance disturbances at the maximum operating speed. The thrust AMB is a hybrid type where a permanent magnet carries the weight of the flywheel and an electromagnetic actuator generates the dynamic control force. We evaluated the design performance of the manufactured AMB through comparison of FEM analysis and the results of experimental force measurement. In order to obtain gains of PD controller and design a notch filter, the system identification was performed through measuring frequency response including dynamics for the AMBs, a power amp and a sensor using a sine swept test method after levitating the flywheel. Through measuring the current input of the AMBs and the orbit of a flywheel according to rotational speed, we verified excellent control performance of the AMBs with small amount current for the large scale SFESS.

Design of Ball Bearing Type OIS Actuator for Mobile Camera Module (모바일 카메라 모듈용 볼베어링 방식 OIS 액추에이터 설계)

  • Song, Myeong-Gyu;Son, Dong-Hun;Park, No-Cheol;Park, Kyoung-Su;Park, Young-Pil;Lim, Soo-Cheol
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.4
    • /
    • pp.361-372
    • /
    • 2010
  • Optical image stabilization is a technique to compensate the image blurring caused by some vibrations of camera at the exposure time. Pitching and yawing of camera are sensitive to the image quality so they are usually compensated by optical image stabilization. Corresponding pitching and yawing of a camera, a lens or the image sensor is translated in two-axis direction and then the optical path of camera is adjusted. In this paper, two-axis OIS actuator for mobile camera module is suggested and designed. The actuator is a voice-coil actuator that uses the electromagnetic force of voice-coil to make compensation motions. And ball bearing is used to reduce friction force. Magnetic attractive force between magnets and yokes acts as a preload and magnet springs. Prototype actuator is fabricated to measure the friction force and to verify the feasibility of the OIS actuator with ball bearing. At last, the actuator is improved in consideration of driving force and friction force. Design of experiments is used for designing the actuator.

Development of autonomous system using magnetic position meter (자기거리계를 이용한 자율주행시스템의 개발)

  • Kim, Geun-Mo;Ryoo, Young-Jae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.3
    • /
    • pp.343-348
    • /
    • 2007
  • Development of autonomous vehicle system that use magnetic position meter research of intelligence transportation system is progressed worldwide active by fast increase of vehicles. Among them, research about autonomous of vehicles occupies field. And autonomous of vehicles is element that path recognition is basic. Existent magnetic base autonomous system analyzes three-dimensional data of magnet marker to 3 axises magnetic sensor and recognized route. But because using Magnetic Wire and Magnetic Position Meter in treatise that see, measure side lateral error and propose system that driving. And system that compare with system of autonomous vehicles and propose wishes to verify by hardware of that specification and simple algorithm through an experiment that autonomous is available.

A Novel Rotor Position Error Calculation Method using a Rotation Matrix for a Switching Frequency Signal Injected Sensorless Control in IPMSM (스위칭 주파수 신호 주입 IPMSM 센서리스 제어를 위한 회전 행렬 기반의 새로운 위치 오차 추정 기법)

  • Kim, Sang-Il;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.5
    • /
    • pp.402-409
    • /
    • 2015
  • This paper proposes a novel rotor position error calculation method for high-frequency signal-injected sensorless control. The rotor position error using the conventional modulation method can be only measured up to ${\pm}45^{\circ}$. In addition, when the rotor position estimation error is not sufficiently small, the small angle approximation in no longer valid. To overcome these problems, this study introduces a new rotor position error calculation method using the rotating matrix. In this study, the position error measurement range of the proposed method is extended from ${\pm}45^{\circ}$ to ${\pm}90^{\circ}$. The linearity between the real rotor position error and the estimated error is maintained by nearly $90^{\circ}$. These features of the proposed method improve the performance of the sensorless control. The validity of the proposed method is verified by simulations and experiments.

A Study on starting Characteristics Improvement of Sensorless BLDC Motor (센서리스 구동 브러시리스 DC 모터의 기동 특성 개선에 관한 연구)

  • Hong, Sun-Ki
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.54-59
    • /
    • 2005
  • Brushless DC motor is a motor which is modified form DC brush motor and it does not have brushes. BLDCM is easy to centre, has wide speed range, high efficiency. However it needs speed sensor like encoder which increases the motor price and cause some faults in poor surroundings.. In this paper, for the sensorless control, the driving techniques for the initial stable start and the steady state are studied For the steady state the rotor position is determined using the measured back-EMF. To enhance the initial stating performance, the current signal from the free-wheeling diode is used. The results are conformed through the experiments.

Magnetic Guidance Vehicle using Up-and-down Rotating Type Differential Drive Unit (상하 회전형 차동 구동부를 이용한 자기 유도 무인운반차)

  • Song, Hajun;Cho, Hyunhak;Kim, Sungshin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.2
    • /
    • pp.123-128
    • /
    • 2014
  • This paper presents the study about MGV(Magnetic guidance vehicle) with up-and-down rotating type differential drive unit. Previous MGV needs the landmarks to get the driving information and additional sensor to recognize the landmarks except for localization sensor. Previous MGV requires at least 2 drive units when common fixed differential drive unit is used because it occurs the problems with driving control and localization error from imbalance of the MGV's weight. To solve such problems, we propose the MGV using up-and-down rotating type differential drive unit. Proposed MGV recognizes the driving information from the pattern which is consisted of both pole of magnet without landmarks and additional sensors, and it control the backward movement using up-and-down rotating type differential drive unit instead of common drive units. Proposed MGV considers KF(Kalman filter) to improve the localization accuracy. To verify the performance of proposed method, we designed MGV for the experiment. As the results, we can confirm the performance of propoesed method to recognize the pattern and to control the backward movement. With respect to localization, proposed method has the less RMSE about 5.6904 mm than previous method.

System Development of Precision Vision Measurement Using Fuzzy C-Means Algorithm (Fuzzy C-Means를 이용한 정밀 영상측정 시스템 개발)

  • 김석현
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.4 no.4
    • /
    • pp.7-14
    • /
    • 1999
  • The measuring systems of auto-parts are most of greater part very expensive. This paper tries to study to make a low-cost measuring equipment there's several kinds of parts in automobile. In this study, we take aircon-switch called magnet coil-housing as the object of measurements. The measurements of this product is currently in difficult situations at factory. In the case of the mesuring objects being big sizes and camera sensor having under 410000 pixels, the key point is the number of pixels not to be changed whenever the same object is measured under the same position. We modified and used fuzzy c-means algorithm to get mostly without the change of the numbers of pixels exactly. Also, the standardized ruler is necessary to measure the length of the object but it is not easy to get the precised ruler. Therefore, the standard length has been taken as the mean value of the pixels in the previous passed objects manually obtained at factory. The results are displayed on monitor and transferred these signals to the microprocessor through RSC-232 port to determine a good or bad of products.

  • PDF

System Development of Precision Vision Measurement Using Fuzzy C-means and Possibilistic C-Means Algorithm (Fuzzy C-means와 확률 C-Means를 결합한 정밀 영상측정 시스템 개발)

  • 김석현
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 1999.12a
    • /
    • pp.315-323
    • /
    • 1999
  • The measuring systems of auto-parts are most of greater part very expensive. This paper tries to study to make a low-cost measuring equipment. There's several kinds of parts in automobile. In this study, we take aircon-switch called magnet coil-housing as the object of measurements. The measurements of this product is currently in difficult situations at factory. In the case of the mesuring objects being big sizes and camera sensor having under 410000 pixels, the key point is the number of pixels not to be changed whenever the same object is measured under the same position. We modified and used fuzzy c-means algorithm to get mostly without the change of the numbers of pixels exactly. Also, the standardized ruler is necessary to measure the length of the object but it is not easy to get the precised ruler. Therefore, the standard length has been taken as the mean value of the pixels in the previous passed objects manually obtained at factory. The results are displayed on monitor and transferred these signals to the microprocessor through RSC-232 port to determine a good or bad of products.

  • PDF