Immune Cell Activation and Co-X-irradiation Effect of Eleutherococcus senticosus Maxim Root (가시오갈피 뿌리의 면역세포 활성 및 방사선 병용효과)

  • Kwon, Hyoung-Cheol;Park, Jeong-Seob;Choi, Dong-Seong
    • Radiation Oncology Journal
    • /
    • v.25 no.3
    • /
    • pp.185-191
    • /
    • 2007
  • Purpose: This study was performed to investigate the effects of immune cell activation and the antitumor effect for the combination of treatment with X-irradiation and E/eutherococcus senticosus Maxim Root (ESMR) on mouse tumor cells. Materials and Methods: ESMR (250g) was extracted with 80% methanol, concentrated under decompression and lyophilized. To determine whether ESMR is able to activate the immune cells or not, the proliferation of splenocytes in vitro and the number of B cells and T cells in splenic lymphocytes in ESMR-pretreated mice were evaluated. X-irradiation was given to the mouse fibrosarcoma tumor cells (FSa II) by 250 kv X-irradiation machine. The cytotoxicity of ESMR was evaluated from its ability to reduce the clonogenecity of FSa II cells. In X-irradiation alone group, each 2, 4, 6 and 8 Gy was given to FSa II cells. In X-irradiation with ESMR group, 0.2 mg/ml of ESMR was exposed to FSa II cells for 1 hour before X-irradiation. Results: The proliferation of cultured mouse splenocytes and thymocytes were enhanced by the addition of ESMR in vitro. The number of B cells and T cells in mouse splenic lymphocytes was significantly increased in ESMR pretreated mice in vivo. In FSa II cells that received a combination of 0.2 mg/ml of ESMR with X-irradiation exposure, the survival fraction with a dose of 2, 4 and 6 Gy was $0.39{\pm}0.005$, $0.22{\pm}0.005$ and $0.06{\pm}0.007$, respectively. For FSa II cells treated with X-irradiation alone, the survival fraction with a dose of 2, 4 and 6 Gy was $0.76{\pm}0.02$, $0.47{\pm}0.008$ and $0.37{\pm}0.01$. The difference in the survival fraction of the mouse FSa II cells treated with and without ESMR was statistically significant (p<0.05). Conclusion: Treatment with ESMR increased cell viability of mouse splenocytes in vitro and especially the subpopulation of B cells and T cells in splenocytes in ESMR-pretreated mice. However, treatment with ESMR did not increase the level of Th and Tc subpopulations in the thymocytes. Treatment with the combination of ESMR and X-irradiation was more cytotoxic to mouse tumor cells than treatment with X-irradiation alone; this finding was statistically significant.

An Implementation Method of the Character Recognizer for the Sorting Rate Improvement of an Automatic Postal Envelope Sorting Machine (우편물 자동구분기의 구분율 향상을 위한 문자인식기의 구현 방법)

  • Lim, Kil-Taek;Jeong, Seon-Hwa;Jang, Seung-Ick;Kim, Ho-Yon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.12 no.4
    • /
    • pp.15-24
    • /
    • 2007
  • The recognition of postal address images is indispensable for the automatic sorting of postal envelopes. The process of the address image recognition is composed of three steps-address image preprocessing, character recognition, address interpretation. The extracted character images from the preprocessing step are forwarded to the character recognition step, in which multiple candidate characters with reliability scores are obtained for each character image extracted. aracters with reliability scores are obtained for each character image extracted. Utilizing those character candidates with scores, we obtain the final valid address for the input envelope image through the address interpretation step. The envelope sorting rate depends on the performance of all three steps, among which character recognition step could be said to be very important. The good character recognizer would be the one which could produce valid candidates with very reliable scores to help the address interpretation step go easy. In this paper, we propose the method of generating character candidates with reliable recognition scores. We utilize the existing MLP(multilayered perceptrons) neural network of the address recognition system in the current automatic postal envelope sorters, as the classifier for the each image from the preprocessing step. The MLP is well known to be one of the best classifiers in terms of processing speed and recognition rate. The false alarm problem, however, might be occurred in recognition results, which made the address interpretation hard. To make address interpretation easy and improve the envelope sorting rate, we propose promising methods to reestimate the recognition score (confidence) of the existing MLP classifier: the generation method of the statistical recognition properties of the classifier and the method of the combination of the MLP and the subspace classifier which roles as a reestimator of the confidence. To confirm the superiority of the proposed method, we have used the character images of the real postal envelopes from the sorters in the post office. The experimental results show that the proposed method produces high reliability in terms of error and rejection for individual characters and non-characters.

  • PDF

Clinical Study of Acute and Chronic Pain by the Application of Magnetic Resonance Analyser $I_{TM}$ (자기공명분석기를 이용한 통증관리)

  • Park, Wook;Jin, Hee-Cheol;Cho, Myun-Hyun;Yoon, Suk-Jun;Lee, Jin-Seung;Lee, Jeong-Seok;Choi, Surk-Hwan;Kim, Sung-Yell
    • The Korean Journal of Pain
    • /
    • v.6 no.2
    • /
    • pp.192-198
    • /
    • 1993
  • In 1984, a magnetic resonance spectrometer(magnetic resonance analyser, MRA $I_{TM}$) was developed by Sigrid Lipsett and Ronald J. Weinstock in the USA, Biomedical applications of the spectrometer have been examined by Dr. Hoang Van Duc(pathologist, USC), and Nakamura, et al(Japan). From their theoretical views, the biophysical functions of this machine are to analyse and synthesize a healthy tissue and organ resonance pattern, and to detect and correct an abnormal tissue and organ resonance pattern. All of the above functions are based on Quantum physics. The healthy tissue and organ resonance patterns are predetermined as standard magnetic resonance patterns by digitizing values based on peak resonance emissions(response levels or high pitched echo-sounds amplified via human body). In clinical practice, a counter or neutralizing resonance pattern calculated by the spectrometer can correct a phase-shifted resonance pattern(response levels or low pitched echo-sounds) of a diseased tissue and organ. By administering the counter resonance pattern into the site of pain and trigger point, it is possible to readjust the phase-shifted resonance pattern and then to alleviate pain through regulation of the neurotransmitter function of the nervous system. For assessing clinical effectiveness of pain relief with MRA $I_{TM}$ this study was designed to estimate pain intensity by the patient's subjective verbal rating scale(VRS such as graded to no pain, mild, moderate and severe) before application of it, to evaluate an amount of pain relief as applied the spectrometer by the patients subjective pain relief scale(visual analogue scale, VAS, 0~100%), and then to observe a continuation of pain relief following its application for managing acute and chronic pain in the 102 patients during an 8 months period beginning March, 1993. An application time of the spectrometer ranged from 15 to 30 minutes daily in each patient at or near the site of pain and trigger point when the patient wanted to be treated. The subjects consisted of 54 males and 48 females, with the age distribution between 23~40 years in 29 cases, 41~60 years in 48 cases and 61~76 years in 25 cases respectively(Table 1). The kinds of diagnosis and the main site of pain, the duration of pain before the application, and the frequency of it's application were recorded on the Table 2, 3 and 4. A distinction between acute and chronic pain was defined according to both of the pain intervals lasting within and over 3 months. The results of application of the spectrometer were noted as follows; In 51 cases of acute pain before the application, the pain intensities were rated mild in 10 cases, moderate in 15 cases and severe in 26 cases. The amounts of pain relief were noted as between 30~50% in 9 cases, 51~70% in 13 cases and 71~95% in 29 cases. The continuation of pain relief appeared between 6~24 hours in two cases, 2~5 days in 10 cases, 6~14 days in 4 cases, 15 days in one case, and completely relived of pain in 34 cases(Table 5~7). In 51 cases of chronic pain before the application, the pain intensities were rated mild in 12 cases, moderate in l8 cases and severe in 21 cases. The amounts of pain relief were noted as between 0~50% in 10 cases, 51~70% in 27 cases and 71~90% in 14 cases. The continuation of pain relief appeared to have no effect in two cases. The level of effective duration was between 6~12 hours in two cases, 2~5 days in 11 cases, 6~14 days in 14 cases, 15~60 days in 9 cases and in 13 cases the patient was completely relieved of pain(Table 5~7). There were no complications in the patients except a mild reddening and tingling sensation of skin while applying the spectrometer. Total amounts of pain relief in all of the subjects were accounted as poor and fair in 19(18.6%) cases, good in 40(39.2%) cases and excellent in 43(42.2%) cases. The clinical effectiveness of MRA $I_{TM}$ showed variable distributions from no improvements to complete relief of pain by the patient's assessment. In conclusion, we suggest that MRA $I_{TM}$ may be successful in immediate and continued pain relief but still requires several treatments for continued relief and may be gradually effective in pain relief while being applied repeatedly.

  • PDF

Experimental Studies on the Properties of Epoxy Resin Mortars (에폭시 수지 모르터의 특성에 관한 실험적 연구)

  • 연규석;강신업
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.26 no.1
    • /
    • pp.52-72
    • /
    • 1984
  • This study was performed to obtain the basic data which can be applied to the use of epoxy resin mortars. The data was based on the properties of epoxy resin mortars depending upon various mixing ratios to compare those of cement mortar. The resin which was used at this experiment was Epi-Bis type epoxy resin which is extensively being used as concrete structures. In the case of epoxy resin mortar, mixing ratios of resin to fine aggregate were 1: 2, 1: 4, 1: 6, 1: 8, 1:10, 1 :12 and 1:14, but the ratio of cement to fine aggregate in cement mortar was 1 : 2.5. The results obtained are summarized as follows; 1.When the mixing ratio was 1: 6, the highest density was 2.01 g/cm$^3$, being lower than 2.13 g/cm$^3$ of that of cement mortar. 2.According to the water absorption and water permeability test, the watertightness was shown very high at the mixing ratios of 1: 2, 1: 4 and 1: 6. But then the mixing ratio was less than 1 : 6, the watertightness considerably decreased. By this result, it was regarded that optimum mixing ratio of epoxy resin mortar for watertight structures should be richer mixing ratio than 1: 6. 3.The hardening shrinkage was large as the mixing ratio became leaner, but the values were remarkably small as compared with cement mortar. And the influence of dryness and moisture was exerted little at richer mixing ratio than 1: 6, but its effect was obvious at the lean mixing ratio, 1: 8, 1:10,1:12 and 1:14. It was confirmed that the optimum mixing ratio for concrete structures which would be influenced by the repeated dryness and moisture should be rich mixing ratio higher than 1: 6. 4.The compressive, bending and splitting tensile strenghs were observed very high, even the value at the mixing ratio of 1:14 was higher than that of cement mortar. It showed that epoxy resin mortar especially was to have high strength in bending and splitting tensile strength. Also, the initial strength within 24 hours gave rise to high value. Thus it was clear that epoxy resin was rapid hardening material. The multiple regression equations of strength were computed depending on a function of mixing ratios and curing times. 5.The elastic moduli derived from the compressive stress-strain curve were slightly smaller than the value of cement mortar, and the toughness of epoxy resin mortar was larger than that of cement mortar. 6.The impact resistance was strong compared with cement mortar at all mixing ratios. Especially, bending impact strength by the square pillar specimens was higher than the impact resistance of flat specimens or cylinderic specimens. 7.The Brinell hardness was relatively larger than that of cement mortar, but it gradually decreased with the decline of mixing ratio, and Brinell hardness at mixing ratio of 1 :14 was much the same as cement mortar. 8.The abrasion rate of epoxy resin mortar at all mixing ratio, when Losangeles abation testing machine revolved 500 times, was very low. Even mixing ratio of 1 :14 was no more than 31.41%, which was less than critical abrasion rate 40% of coarse aggregate for cement concrete. Consequently, the abrasion rate of epoxy resin mortar was superior to cement mortar, and the relation between abrasion rate and Brinell hardness was highly significant as exponential curve. 9.The highest bond strength of epoxy resin mortar was 12.9 kg/cm$^2$ at the mixing ratio of 1:2. The failure of bonded flat steel specimens occurred on the part of epoxy resin mortar at the mixing ratio of 1: 2 and 1: 4, and that of bonded cement concrete specimens was fond on the part of combained concrete at the mixing ratio of 1 : 2 ,1: 4 and 1: 6. It was confirmed that the optimum mixing ratio for bonding of steel plate, and of cement concrete should be rich mixing ratio above 1 : 4 and 1 : 6 respectively. 10.The variations of color tone by heating began to take place at about 60˚C, and the ultimate change occurred at 120˚C. The compressive, bending and splitting tensile strengths increased with rising temperature up to 80˚ C, but these rapidly decreased when temperature was above 800 C. Accordingly, it was evident that the resistance temperature of epoxy resin mortar was about 80˚C which was generally considered lower than that of the other concrete materials. But it is likely that there is no problem in epoxy resin mortar when used for unnecessary materials of high temperature resistance. The multiple regression equations of strength were computed depending on a function of mixing ratios and heating temperatures. 11.The susceptibility to chemical attack of cement mortar was easily affected by inorganic and organic acid. and that of epoxy resin mortar with mixing ratio of 1: 4 was of great resistance. On the other hand, when mixing ratio was lower than 1 : 8 epoxy resin mortar had very poor resistance, especially being poor resistant to organicacid. Therefore, for the structures requiring chemical resistance optimum mixing of epoxy resin mortar should be rich mixing ratio higher than 1: 4.

  • PDF

SHEAR BOND STRENGTH AND MICROLEAKAGE OF COMPOSITE RESIN ACCORDING TO TREATMENT METHODS OF CONTAMINATED SURFACE AFTER APPLYING A BONDING AGENT (접착제 도포후 오염된 표면의 처리방법에 따른 복합레진의 전단결합강도와 미세누출)

  • Park, Joo-Sik;Lee, Suck-Jong;Moon, Joo-Hoon;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.647-656
    • /
    • 1999
  • The purpose of this study was to investigate the shear bond strength and marginal microleakage of composite to enamel and dentin according to different treatment methods when the applied bonding agent was contaminated by artificial saliva. For the shear bond strength test, the buccal and occlusal surfaces of one hundred twenty molar teeth were ground to expose enamel(n=60) and dentin surfaces(n=60). The specimens were randomly assigned into control and 5 experimental groups with 10 samples in each group. In control group, a bonding system(Scotchbond$^{TM}$ Multi-Purpose plus) and a composite resin(Z-100$^{TM}$) was bonded on the specimens according to manufacture's directions. Experimental groups were subdivided into 5 groups. After polymerization of an adhesive, they were contaminated with at artificial saliva on enamel and dentin surfaces: Experimental group 1 ; artificial saliva was dried with compressed air. Experimental group 2 ; artificial saliva was rinsed with air-water spray and dried. Experimental group 3 ; artificial saliva was rinsed, dried and applied an adhesive. Experimental group 4 ; artificial saliva was rinsed, dried, and then etched using phosphoric acid followed by an adhesive. Experimental group 5, artificial saliva was rinsed, dried, and then etched with phosphoric acid followed by consecutive application of both a primer and an adhesive. Composite resin(Z-100$^{TM}$) was bonded on saliva-treated enamel and dentin surfaces. The shear bond strengths were measured by universal testing machine(AGS-1000 4D, Shimaduzu Co. Japan) with a crosshead speed of 5mm/minute under 50kg load cell. Failure modes of fracture sites were examined under stereomicroscope. The data were analyzed by one-way ANOVA and Tukey's test. For the marginal microleakage test, Class V cavities were prepared on the buccal surfaces of sixty molars. The specimens were divided into control and experimental groups. Cavities in experimental group were contaminated with artificial saliva and those surfaces in each experimental groups received the same treatments as for the shear test. Cavities were filled with Z-100. Specimens were immersed in 0.5% basic fuchsin dye for 24 hours and embedded in transparent acrylic resin and sectioned buccolingually with diamond wheel saw. Four sections were obtained from the one specimen. Marginal microleakages of enamel and dentin were scored under streomicroscope and averaged from four sections. The data were analyzed by Kruskal-Wallis test and Fisher's LSD. The results of this study were as follows. 1. The shear bond strength to enamel showed lower value in experimental group 1(13.20${\pm}$2.94MPa) and experimental group 2(13.20${\pm}$2.94MPa) than in control(20.03${\pm}$4.47MPa), experimental group 4(20.96${\pm}$4.25MPa) and experimental group 5(21.25${\pm}$4.48MPa) (p<0.05). 2. The shear bond strength to dentin showed lower value in experimental group 1(9.35${\pm}$4.11MPa) and experimental group 2(9.83${\pm}$4.11MPa) than in control group(17.86${\pm}$4.03MPa), experimental group 4(15.04${\pm}$3.22MPa) and experimental group 5(14.33${\pm}$3.00MPa) (p<0.05). 3. Both on enamel and dentin surfaces, experimental group 1 and 2 showed many adhesive failures, but control and experimental group 3, 4 and 5 showed mixed and cohesive failures. 4. Enamel marginal microleakage was the highest in experimental group 1 and there was a significant difference in comparison with other groups (p<0.05). 5. Dentin marginal microleakages of experimental group 1 and 2 were higher than those of other groups (p<0.05). This result suggests that treatment methods, re-etching with 35% phosphoric acid followed by re-application of adhesive or repeating all adhesive procedures, will produce good effect on both shear bond strength and microleakage of composite to enamel and dentin if the polymerized bonding agent was contaminated by saliva.

  • PDF

BONDING OF RESIN INLAY TO GLASS-IONOMER BASE WITH VARIOUS TREATMENTS ON INLAY SURFACE (내표면 처리에 따른 레진 인레이와 글래스아이오노머 베이스간의 접착)

  • Jang, Byung-Sung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.399-406
    • /
    • 2000
  • The effect of inlay surface treatment on bonding was investigated when resin inlay was bonded to resin-modified glass-ionomer base with resin cement. For the preparation of glass-ionomer base, resin-modified glass-ionomer cement (Fuji II LC, GC Co., Japan) was filled in class I cavities of 7mm in diameter and 2mm in depth made in plastic molds. Eighty eight resin inlay specimens were made with Charisma$^{(R)}$ (Kulzer, Germany) and then randomly assigned to the four different surface treatment conditions: Group I, $50{\mu}m$ aluminium oxide sandblasting and silane treatment ; Group II, silane treatment alone ; Group III, sandblasting alone, and Group IV (control), no surface treatment. After a dentin bonding agent with primer (One-Step$^{TM}$, Bisco Inc., IL., U.S.A.) was applied to bonding surface of resin inlay and base, resin inlay were cemented to glass-ionomer base with a resin cement (Choice$^{TM}$, Bisco Inc., IL., U.S.A.). Shear bond strengths of each specimens were measured using Instron universal testing machine (4202 Instron, lnstron Co., U.S.A.) and fractured surfaces were examined under the stereoscope. Statistical analysis was done with one-way ANOVA and Dunkan's multiple range test. The results were as follows: 1. Sandblasting and silane treatment provided the greatest bond strength(10.56${\pm}$1.95 MPa), and showed a significantly greater bond strength than sandblasting alone or no treatment (p<0.05). 2. Silane treatment provided a significantly greater bond strength(9.77${\pm}$2.04 MPa) than sandblasting alone or no treatment (p<0.05). However, there was no significant difference in bond strength between sandblasting treatment and silane one (p>0.05). 3. Sandblasting alone provided no significant difference in bond strength from no treatment (p>0.05). 4. Stereoscopic examination of fractured surface showed that sandblasting and silane treatment or silane treatment alone had more cohesive failure mode than adhesive failure mode. 5. In relationship between shear bond strength and failure mode, cohesive failure occurred more frequently as bond strength increased.

  • PDF

Semi-supervised learning for sentiment analysis in mass social media (대용량 소셜 미디어 감성분석을 위한 반감독 학습 기법)

  • Hong, Sola;Chung, Yeounoh;Lee, Jee-Hyong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.5
    • /
    • pp.482-488
    • /
    • 2014
  • This paper aims to analyze user's emotion automatically by analyzing Twitter, a representative social network service (SNS). In order to create sentiment analysis models by using machine learning techniques, sentiment labels that represent positive/negative emotions are required. However it is very expensive to obtain sentiment labels of tweets. So, in this paper, we propose a sentiment analysis model by using self-training technique in order to utilize "data without sentiment labels" as well as "data with sentiment labels". Self-training technique is that labels of "data without sentiment labels" is determined by utilizing "data with sentiment labels", and then updates models using together with "data with sentiment labels" and newly labeled data. This technique improves the sentiment analysis performance gradually. However, it has a problem that misclassifications of unlabeled data in an early stage affect the model updating through the whole learning process because labels of unlabeled data never changes once those are determined. Thus, labels of "data without sentiment labels" needs to be carefully determined. In this paper, in order to get high performance using self-training technique, we propose 3 policies for updating "data with sentiment labels" and conduct a comparative analysis. The first policy is to select data of which confidence is higher than a given threshold among newly labeled data. The second policy is to choose the same number of the positive and negative data in the newly labeled data in order to avoid the imbalanced class learning problem. The third policy is to choose newly labeled data less than a given maximum number in order to avoid the updates of large amount of data at a time for gradual model updates. Experiments are conducted using Stanford data set and the data set is classified into positive and negative. As a result, the learned model has a high performance than the learned models by using "data with sentiment labels" only and the self-training with a regular model update policy.

The Effect of Au Addition on the Hardening Mechanism in Ag-30wt%Pd-10wt%Cu Alloy (Ag-30wt% Pd-10wt% Cu 3원합금(元合金) 및 Au 첨가합금(添加合金)의 시효경화특성(時效硬化特性))

  • Lee, K.D.;Nam, S.Y.
    • Journal of Technologic Dentistry
    • /
    • v.21 no.1
    • /
    • pp.27-41
    • /
    • 1999
  • The Ag-Pd-Cu alloys containing a small amount of Au is commonly used for dental purposes, because this alloy cheaper than Au-base alloys for clinical use. However, the most important characteristic of this alloy is age-hardenability, which is not exhibited by other Ag-base dental alloys. The specimens used were Ag-30Pd-10Cu ternary alloy and Au addition alloy. These alloys were melted and casted by induction electric furnace and centrifugal casting machine in Ar atmosphere. These specimens were solution treated for 2hr at $800^{\circ}C$ and were then quenched into iced water, and aged at 350-$550^{\circ}C$ Age-hardening characteristic of the small Au-containing Ag-Pd-Cu dental alloys were investigated by means of hardness testing, X-ray diffraction and electron microscope observations, electrical resistance, differential scanning calorimetric, energy dispersed spectra and electron probe microanalysis. Principal results are as follows ; Maximum hardening occured in two co-phases of ${\alpha}_2$ + PdCu In stage II, decomposition of the $\alpha$ solid solution to a PdCu ordered phase($L1_o$ type) and an Ag-rich ${\alpha}_2$ phase occurred and a discontinuous precipitation occurred at the grain boundary. From the electron microscope study, it was concluded that the cause of age-hardening in this alloy is the precipitation of the PdCu redered phase, which has AuCu I type face-centered tetragonal structure. Precipitation procedure was ${\alpha}{\to}{\alpha}_1+PdCu{\to}{\alpha}_2+PdCu$ at Pd/Cu = 3 Pd element of Ag-Pd-Cu alloy is more effective dental alloy on anti-corrosion and is suitable to isothermal ageing at $450^{\circ}C$.

  • PDF

The Effect of Au Addition on the Hardening Mechanism in Ag-20wt% Pd-20wt% Cu (Ag-20wt% Pd-20wt% Cu 3원합금(元合金) 및 Au첨가합금(添加合金)의 시효경화특성(時效硬化特性))

  • Park, M.H.;Bae, B.J.;Lee, H.S.;Lee, K.D.
    • Journal of Technologic Dentistry
    • /
    • v.19 no.1
    • /
    • pp.21-35
    • /
    • 1997
  • The Ag-Pd-Cu alloys containing a small amount of Au is commonly used for dental purposes, because this alloy is cheaper than Au-base alloys for clinical use. However, the most important characteristic of this alloy is age-hardenability, which is not exhibited by other Ag-base dental alloys. The specimens used were Ag-20Pd-20Cu ternary alloy and Au addition alloy. These alloys were melted and casted by induction electic furace and centrifugal casting machine in Ar atmoshpere. These specimens were solution treated for 2hr at $800^{\circ}C$ and were then quenched into iced water, and aged at $350{\sim}550^{\circ}C$ Age-hardening characteristics of the small Au-containing Ag-pPd-Cu dental alloys were investigated by means of hardness testing, X-ray diffraction and electron microscope observations, electrical resistance, differential scanning calorimetric, emergy dispersed spectra and electron probe microanalysis. Principal results are as follows : Hardening occured in two stages, I. e., stage I in low temperature and stage II in high temperature regions, during continuous aging. The case of hardening in stage I was due to the formation of the Llo type face centered tetragonal PdCu-ordered phase in the grain interior and hardening in stage I was affedted by the Cu concentration. In stage II, decomposition of the $\alpha$ solid solution to a PdCu ordered phase(L1o type) and an Agrich ${\alpha}2$ phase occurred and a discontiunous precipitation occurred at the grain boundary. Form the electron microscope study, it was concluded that the cause of age-hardening in this alloy is the precipitation of the PdCu ordered phase, which has AuCu I type face-centered tetragonal structure. Precipitation procedure was ${\alpha}\to{\alpha}+{\alpha}2+PdCu\to{\alpha}1+{\alpha}2+PdCu$ at Pd/Cu = 1 Ag-Pd-Cu alloy is more effective dental alloy as ageing treatment and is suitable to isothermal ageing at $450^{\circ}C$.

  • PDF

APPLICATION OF ACIDIC PRIMER FOR ORTHODONTIC ADHESIVE SYSTEM (Acidic primer를 이용한 교정용 브라켓 접착의 전단결합강도)

  • Kim, Jin-Hee;Jin, Hun-Hee;Oh, Jang-Kyun
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.137-147
    • /
    • 2001
  • Acidic primer is the bonding agent which combines the conditioning and priming agent into the single solution and was originally developed for the dentin bonding system. It is less harmful to the tooth structure and more convenient to manipulate than the traditional etching procedure. The Purpose of this study is to evaluate the shear bond strength of various bonding materials when the enamel is treated with acidic primer for the bracket bonding procedure. Fifty recently extracted human premolars were randomly separated into five groups -Group I using Clearfil Liner Bond 2 adhesive system to the enamel treated with acidic primer, Group II using Transbond XT adhesive system to the enamel treated with acidic primer, Group III using panavia 21 adhesive system to the enamel treated with acidic primer, Group IV using Fuji-Ortho LC adhesive system to the enamel treated with acidic primer, Group V using Transbond XT adhesive system to the enamel treated with 37$\%$ phosphoric acid. The shear bond strength was measured with Instron universal testing machine after storing in $37^{\circ}C$ water bath for 48 hours. After debonding, the teeth and brackets were examined under scanning electron microscope (SEM) and assessed with the adhesive remnant index (ARI). The results were as follows : 1. There were no significant differences in shear bond strength between group III ($8.69{\pm}2.72MPa$), group IV (9.7 ± 3.16 MPa), and group V ($10.48{\pm}2.60MPa$) (p>0.05). 2. The shear bond strength of group III and group IV was significantly higher than that of group I ($1.09{\pm}0.53MPa$), and Group II ($2.70{\pm}1.46MPa$) (p<0.05). 3. The ARI of group IV ($2.1{\pm}1.1$) and group V ($2.9{\pm}0.3$) was significantly higher than that of group I ($0.2{\pm}0.4$), group II ($0.3{\pm}0.9$) and group III ($0.2{\pm}0.4$) (p<0.05). 4. There were no significant difference between the ARI of group IV and group V (p>0.05). This result suggests that the combination of acidic primer and some bonding adhesive can provide sufficient shear bond strength for clinical orthodontics.

  • PDF