• Title/Summary/Keyword: machine

Search Result 24,373, Processing Time 0.052 seconds

A Study of the Accidents of the Residents in a Rural Area (일개 보건진료소 사업 지역의 사고조사)

  • Kang, Pock-Soo;Lee, Kyeong-Soo;Kim, Seok-Beom;Kim, Chang-Yoon;Lee, Ok-Keum
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.2
    • /
    • pp.174-184
    • /
    • 1991
  • To determine the incidence rate of accidents and its associated factors, a prospective survey was carried out in a rural area of a total of 1,360 residents for 1 year from January 1 to December 31, 1988 in Shin-am Ri, Jungdong Myun, Sangju Kun, Kyungpook Province. Data for accidents were collected by the community health practitioner who is working at Primary Health Post in Shin-am Ri. A total number of accident cases was 85 among 1,360 persons during one year study period, and annual incidence rate was 62.5 per 1,000 persons. The highest incidence rate of accident was observed in the age group of 30-39 was 179.8. The incidence rate of accident in male was 86.5 which was about 2 times that in female. In male, the highest incidence rate was seen in 30-39 age group and in female, 60-69 age group. The highest incidence rate of accident was observed in spring(29.4%) and summer(29.4%), and the lowest in fall(17.7%). The highest incidence rate of accident was observed in Friday(24.5%) by day of week, and between 9 a.m. to 12 a.m. by time zone. The most frequent use of medical facilities was Primary Health Post(51.8%) and the next was clinic(38.8%). Mean duration of treatment was 9.8 days. The accident occured in the room and kitchen(23.5%), in the yard and barn(23.5%), on the road(22.4%). and in the rice field and dry field(20.0%). The causes of accident were motor vehicle accident(20.0%), piercing or cutting(20.0%), collision or fighting(12.9%), and poisoning(11.8%) in order of frequency. The most common type of injury was open wound which was 43.5%. The most common tool of accident was farm machine which was 23.5%. The most common injuried part of body was extremity(55.3%).

  • PDF

Effect of Heat Treatment in Dried Lavers and Modified Processing (마른김에 대한 열처리 효과와 제조 공정 개선 시험)

  • Lee, Tae-Seek;Lee, Hee-Jung;Byun, Han-Seok;Kim, Ji-Hoe;Park, Mi-Jung;Park, Hi-Yun;Jung, Kyoo-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.6
    • /
    • pp.529-532
    • /
    • 2000
  • To establish a food safety of dried layer, heat treatment effect on the bacterial density of dried layers was investigated. And a modified process developing experiment for dried layer products using closing type drying oven was carried out. tittle bacterial density difference on the dried layer products were found before and after heat treatment at $90^{\circ}C$ for 6 hrs called Hwaip treatment having been used for long term storage. Direct or indirect heat treatment of dried lavers using gas burner and frying pan reduced about 1 to 3 log cycle of viable cell count from $10^8\;CFU/g\;to\;10^5\;CFU/g$. Heat treatment by direct surface contact type cooking machine being used in the market place for cooked dried layer products could reduce the viable cell count on the layer product from $2.2{\times}10^5{\~}5.2{\times}10^7\;CFU/g\;to\;7.0{\times}10^2{\~}5.0{\times}10^5\;CFU/g$, Ultraviolet irradiation (20 W, 30 cm) to one or both side of the dried laver products reduced the viable cell count from $2.2{\times}10^6\;CFU/g\;to\;8.0{\times}10^5\;CFU/g\;and\;2.0{\times}10^5\;CFU/g$, respectively. The viable cell count of the dried layer products produced by modified process using a closing type dryer was about $10^3\;CFU/g$ and lower 3 log cycle than that in the products collected in market place and made by open type dryer.

  • PDF

Survey on sanitary knowledge level and degree of HACCP practice in culinary staff employed in elementary, middle, and high schools in Chungnam province (충남지역 초.중.고 학교급식 조리원의 위생지식 및 HACCP 수행도 조사)

  • Lee, Young Joong;Kim, Sun Hyo
    • Journal of Nutrition and Health
    • /
    • v.47 no.4
    • /
    • pp.300-312
    • /
    • 2014
  • Purpose: This study was performed to examine the sanitary knowledge level and degree of HACCP (hazard analysis critical control point) practice in school culinary staff in order to provide basic information for improving hygiene of school meals. Methods: Exactly 305 culinary staff members were selected from elementary, middle, and high schools in 14 cities and rural areas, including whole administrative districts in Chungnam province. Surveyed schools were selected by convenience sampling, and one subject was selected randomly from each school. Surveys were taken by self-administered questionnaires developed by researchers and questionnaire were distributed and collected by postal mail. Results: Sanitary education administered by school dietitians to culinary staff was more frequent and longer in elementary schools, followed by middle and high schools (p < 0.001). Sanitary knowledge level and degree of HACCP practice, except for a few CCP or CP of culinary staff, were highest in elementary schools and middle school followed by high schools (p < 0.05), respectively. School class was negatively correlated with sanitary knowledge level of culinary staff (p < 0.01), and frequency of sanitary education was positively correlated with sanitary knowledge level of culinary staff (p < 0.01). Sanitary knowledge level of culinary staff was positively correlated with degree of HACCP practice (p < 0.01). School class, daily frequency of meal service, work experience, rice washing machine, and total score of sanitary knowledge were significant variables influencing degree of HACCP practice in culinary staff. Conclusion: The above results show that the following points should be considered to improve hygiene of school meals. Sanitary education should be administered more frequently by school dietitians to culinary staff, especially to those in high schools, which showed the lowest sanitary knowledge level and degree of HACCP practice. In addition, facilities and equipment required for HACCP practice should be supported in small-sized elementary schools.

THE EFFECT OF WASHING PHOSPHORIC ACID ETCHANT ON SHEAR BOND STRENGTH OF AN ORTHODONTIC ADHESIVE (인산 부식액의 수세가 교정용 접착레진의 전단결합강도에 미치는 영향)

  • Kim, Hee-Kyun;Lee, Ki-Soo;Park, Young-Guk
    • The korean journal of orthodontics
    • /
    • v.26 no.5 s.58
    • /
    • pp.497-507
    • /
    • 1996
  • The aim of present study in vitro was to evaluate and compare the effects of different washing times of enamels etched with low phosphoric acid solution which makes unsoluble salts and etched but contaminated with saliva on shear bond strength of an orthodontic adhesive to enamel, and to observe the washing effect on the etched enamel surface by scanning electron microscope. All brackets were bonded with Mono-$Lok2^{TM)}$) on the labial surface of extracted human bicuspids after etching with $20w/w\%\;and\;37w/w$ and phosphoric acid solution for 60seconds and then washing for 0,5,10 and 20seconds respectedly. After etching with $37w/w\%$ phosphoric acid solution and contaminating with saliva for 30seconds and then washing for 0,5,20 and 30seconds and re-etching for 10seconds. After 24hours passed in the $37^{\circ}C$ water bath, the shear bond strengths were measured on Universal Test Machine. The data were evaluated and tested by ANOVA and Duncan's multiple range test, and those results were as follows. 1. There was no significant differences between (p>0.05) shear bond strength of bonded brackets with 5, 10, 20seconds washing etched enamel using $37{\%}w/w{\%}$ phosphoric acid solution. 2. The shear bond strength of bonded brackets with $20w/w\%$ phosphoric acid and then washing for 5seconds showed bonded strength durable to occlusal force but its coefficiency score was high and etched surface was not cleaned completely and therefore it was assumed that its clinical application is not applicable. 3. There was no significant differences between (p>0.05) shear bond strengths of bonded brckets with washing for 5seconds etched enamel using $37w/w\%$ phosphoric acid solution and 10,20 seconds washing etched enamel using $20w/w\%$ phosphoric acid solution. 4. The shear bond strength of washing for 5seconds etched enamel which was contaminated with saliva showed sufficient bonded strength durable to occlusal force but its coefficiency score was high and therefore its clinical application was not applicable. 5. After etching, the sample contaminated with saliva showed the sufficient shear bond strength even washing 20seconds without re-etching.

  • PDF

A Study on Bracket-Adhesive Combinations in Aspect of Shear Bond Strength and Bond Failure (전단접착강도와 탈락양상을 고려한 브라켓-접착제의 선택)

  • Han, Jae-Ik;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.28 no.6 s.71
    • /
    • pp.955-974
    • /
    • 1998
  • The purpose of the present study was to seek bracket-adhesive combinations which have adequate bond strength with no enamel and bracket fracture. The shear bond strengths were measured, the sites of failure and the enamel damage were investigated and the peripheral sealing and adaptation between enamel surface, bonding adhesive and bracket were evaluated. 240 noncarious human premolars were divided into twenty four groups of ten teeth. Shear bond strengths of each group were determined in an universal testing machine after two days passed and the debonded specimens were inspected to determine the predominant bond failure sites. To evaluate peripheral sealing and adaption between enamel surface, adhesive and bracket, each specimen was cut longitudinally into two halves which included the midsection of the bracket, adhesive and enamel and exmined in scanning electron microscope. Six different types of brackets were bonded to the tooth with four different type of adhesives. Six different types of brackets were Image, Plastic, Crystaline, Fascination, Transcend 2000 and metal bracket and four different adhesives were No-mix, Light-Bond, OrthoLC and Superbond C&B. From this study, it may be concluded that (1) The mean shear bond strength varied from a high of 36.58 Kg (410.07 Kg/$cm^2$) with the Fascination-Light Bond combination group to a low of 8.93 Kg (75.51 Kg/$cm^2$) with theImage-OrthoLC combination group. When using OrthoLC as adhesive, the mean shear bond strength was significantly lower than that of other combination groups, (2) Regardless of adhesives, the mean shear bond strength of Fascination brackets was relatively high whereas Plastic and Image brackets had low shear bonding strength. The shear bond strength of Crystaline bracket and Transcend 2m was relatively equal to or lower than that of metal bracket, (3) There was a correlation between bond strength, enamel damage and bracket fracture. As the shear bond strength was increased, the rate of enamel damage and bracket fracture were increased, (4) The combination groups that use OrthoLC as adhesive were debonded in shear stress without enamel fracture and bracket fracture, whereas the combination groups that use Superbond C&B as adhesive experienced a relative high enamel fracture rate and bracket fracture rate, (5) Peripheral sealing and adaptation between enamel-adhesive-bracket were relatively good when using Light-Bond or No-mix as adhesive. Regardless of adhesives, adaptation between bracket-adhesive were relatively good in Ceramic brackets, (6) The combination groups which had adequate bonding strength with no enamel and bracket fracture were Crystaline-No mix, Crystaline-Light Bond, Crystaline-OrthoLC, metal-No mix, metal-Light Bond and metal-OrthoLC combination groups.

  • PDF

CORRELATIONS BETWEEN ORBICULARIS ORIS AND MENTALIS MUSCLE ACTIVITY AND CRANIOFACIAL MORPHOLOGY IN NORMAL OCCLUSION AND CLASS III MALOCCLUSION (정상교합자와 3급 부정교합자에서 구륜근과 턱끝근의 활성과 안면골격 사이의 상관성에 관한 연구)

  • Chang, Chun Sil;Lee, Ki Soo
    • The korean journal of orthodontics
    • /
    • v.22 no.1
    • /
    • pp.253-271
    • /
    • 1992
  • The purpose of this study was to investigate the difference of EMG activity of the Orbicularis oris and Mentalis muscle between normal occlusion and class III malocclusion group during various lip position and to find out whether any correlations exist between the muscular activity and craniofacial morphology. In this study, 50 subjects with a mean age of 22.9 Years (range 20.0-26.0) were investigated (25 subjects were normal occlusion, and 25 subjects were class III malocclusion). EMG data were recorded from the Orbicularis oris and Mentalis muscle during rest lip posture, lip position at maximum biting, lip position at maximum sealing effort, lip position at chewing, swallowing and phonation with the Medelec MS-25 electromyographic machine. Lateral cephalometric radiographs was taken with the mandible in intercuspal position on all subjects. All data were recorded and statistically processed. The findings of this study can be summerized as follows: 1. In normal occlusion, the maximal mean amplitude of upper lip during the lip position at chewing was lower than that of lower lip and mentalis muscle. But the maximal mean amplitude of orbicularis oris and mentalis muscle during the other lip position was not statistically different. 2. In Class III malocclusion, the maximal mean amplitude of upper lip during the lip position at chewing, swallowing and phonation was lower than that of lower lip and mentalis muscle. But the maximal mean amplitude of orbicularis oris and mentalis muscle during the other lip position was not statistically different. 3. Compare to normal occlusion, the Class III malocclusion was showed low maximal mean amplitude of upper lip during rest lip posture and the lip position at swallowing of saliva, and showed great maximal mean amplitude of lower lip and meantalis muscle during the lip position at chewing and phonation. 4. In normal occlusion, the maximal mean amplitude of upper lip during various lip position was not correlated with the length and thickness of upper lip, but the maximal mean amplitude of lower lip during the lip position at chewing and swallowing was positively correlated with the thickness of lower lip. 5. In Class III malocclusion, the maximal mean amplitude of upper lip during rest lip posture was negatively correlated with the thickness of upper lip, and the maximal mean amplitude of lower lip and mentalis muscle during the lip position at chewing and swallowing was positively correlated with the thickness of lower lip and mentalis muscle. But the maximal mean amplitude of orbicularis oris and mentalis muscle during the other lip position was not correlated with the cephalometric measurements of soft tissue. 6. The correlation between the maximal mean amplitude of orbicularis oris and mentalis muscle and cephalometric measurements of incisors was not nearly present. 7. In normal occlusion, the maximal mean amplitude of lower lip and mentalis muscle during the lip position at maximum biting was negatively correlated with the angle between palatal plane and mandibular plane. In Class III malocclusion, the maximal mean amplitude of upper lip, lower lip and mentalis muscle during function was negatively correlated with the length of maxilla, the maximal mean amplitude of upper lip and lower lip during function was negatively correlated with the SNA and SNPo, and the maximal mean amplitude of lower lip during the lip position at chewing was negatively correlated with the ANB.

  • PDF

THE EFFECT OF TEMPERATURE CHANGES ON THE PHYSICAL PROPERTIES OF POSTERIOR COMPOSITE RESINS (구치부용 복합 레진 가열시 물리적 성질의 변화에 관한 실험적 연구)

  • Park, Yeon-Hong;Min, Byung-Soon;Choi, Ho-Young;Park, Sung-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.1
    • /
    • pp.41-56
    • /
    • 1989
  • The purpose of this study was to examine the effect of temperature dependence of the behavior on the physical properties of posterior composite resins. Three light cure posterior composite resins (Heliomolar, Litefil-P, and P-50) and one chemical cure posterior composite resin (Bisfil-II) were used as experimental materials. Composite resin was placed in a cylindrical brass mold (2.5 mm high and 6.5 mm inside diameter) that was rested on a glass plate. Another flat glass was placed on top of the mold, and the plate was tightly clamped together. After the mold had been filled with the light cure composite material, the top surface was cured for 30 seconds with a light source. Chemical cure resin specimens were made in the same manner as above. Three hundreds and twenty composite resin specimens were constructed from the four composite materials. One hundred and sixty specimens of them were placed in a heater at $50^{\circ}C$, $75^{\circ}C$, $100^{\circ}C$, $125^{\circ}C$, $150^{\circ}C$, $175^{\circ}C$ and $200^{\circ}C$ for 5 minutes or 10 minutes respectively before compressive strengths were measured. Another one hundred and sixty specimens were tested for the diametral tensile strengths in the same way as above. They were randomly divided into eight groups according to the mode of heating methods as follows and stored in distilled water at $37^{\circ}C$ for 24 hours. Group $37^{\circ}C$ - specimens were stored at $37^{\circ}C$ in distilled water for 24 hours. Group $50^{\circ}C$ - specimens were heated at $50^{\circ}C$ after curing. Group $75^{\circ}C$ - specimens were heated at $75^{\circ}C$ after curing. Group $100^{\circ}C$ - specimens were heated at $100^{\circ}C$ after curing. Group $125^{\circ}C$ - specimens were heated at $125^{\circ}C$ after curing. Group $150^{\circ}C$ - specimens were heated at $150^{\circ}C$ after curing. Group $175^{\circ}C$ - specimens were heated at $175^{\circ}C$ after curing. Group $200^{\circ}C$ - specimens were heated at $200^{\circ}C$ after curing. Twenty specimens of each of four composite resins were respectively made by insertion of materials into same mold for examining the dimensional changes between before and after heating. The final eighty specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before testing the dimensional changes. Compressive and diametral tensile strengths were measured crosshead speed 1mm/minute and 500Kg in full scale with a mechanical testing machine (DLC 500 Type, Shimadzu Co., Japan). Dimensional changes were determined by measuring the diametral changes of eighty specimens with micrometer (Mitutoyo Co., Japan). Results were as follows: 1. Diametral tensile strengths of specimens in all groups were increased with time heated compared with control group except for that in group $50^{\circ}C$ and the maximum diametral tensile strength was appeared in the specimen of Litefil-P heated for 10 minutes at $100^{\circ}C$. In heliomolar and P-50, it could be seen in the specimen heated for 10 minutes at $150^{\circ}C$, but in Bisfil-II, it could be found in the specimen heated for 5 minutes at $150^{\circ}C$. 2. Compressive strengths of specimens in all groups was tended to be also increased with time heated but that in group $50^{\circ}C$ and the maximum compressive strengths were showed in the same specimens conditioned as the diametral tensile strengths of four composite materials tested. 3. In Heliomolar, Litefil-P, and Bisfil-II, it was decreased in diameters of resin specimens between before heating and increased in diameters of resin specimens after storing in distilled water, but it was not in P-50. 4. There is little difference in diametral tensile strengths, compressive strengths, and dimensional changes followed by heating the resin specimens for 5 minutes and 10 minutes, but there is no statistical significances.

  • PDF

Effect of X-Irradiation on the Levels of some Sulfhydryl Groups, Protein and Cell Volume of Ehrlich Ascites Tumour Cells (X-선(線) 조사(照射)가 Ehrlich 암세포(癌細胞)의 용적(容積), 단백양(蛋白量) 및 수종(數種) Sulfhydryl 기(基)에 미치는 영향(影響)에 관(關)하여)

  • Yu, Choon-Shik;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.3 no.2
    • /
    • pp.9-16
    • /
    • 1969
  • It is well known that a number of -SH and -SS containing substances afford a certain measure of protection against radiation effects in many biological systems, and it is conceivable that inherent -SH levels in Ehrlich ascites tumour (ELD)cells may be of decisive improtance with respect to the development of cellular radiation injury. So far, little effort has been directed to elucidate the changes in levels of different -SH and -SS groups in ELD cells when the tumour-bearing whole animal was subjected to the sublethal dose of X-irradiation. The present study was designed to bring some lights in the possible changes of and relationship between various sulfhydryl levels, such as P-SH, NP-SH and NP-SS, as well as the content of protein and cell volume of ELD cells, after subjecting the ELD mice to 1,200 r of X-irradiation. The animals used in this experiment were all mixed bred mice of $20{\sim}25\;gm$ in body weight (approximately 2 months old) irrespective of sex. 12 mice in one experiment were inoculated intraperitoneally with 0.2 ml of ascites tumour cells $(2{\times}10^6\;cells)$, and on the 7th day of the tumour growth, they were X-irradiated with 1,200 r, using the conventional X-ray machine under the following conditions: 200 Kv at 15 mA, 0.5 mm Cu filter, target-skin distance: 50 cm. Radiation dose was measured with the the Philip integrating dosimeter. At 24, 36, 48 and 60 hours after the X-irradiation, the mice were killed by cervical dislocation, and the tumours were taken out. Freshly withdrawn ascites tumours were placed in ice, and immediately the cell concentration was measured with the Coulter Cell Counter (Model B), and the hematocrit of the tumour cells were also determined. Cell volume was thus calculated by the cell concentration and hematocrit value. P-SH content of ELD cells was measured potentiometrically according to the method of Calcutt & Doxey, and NP-SH and NP-SS contents were measured spectrophotometrically by the method described by Ellman. Protein content of ELD cells was determined with the Folin phenol reagent by Lowry et al. Altogether, 48 experimental mice were used, and 12 mice with the only exception of X-irradiation were used as the control. Results obtained indicate that the contents of all the cellular sulfhydryl groups as well as cell volume and protein content of the ELD cells increase significantly as time progresses after the sub-lethal X-ray dose of 1,200 r was given and that all the increase is in a lineal fashion. The regression lines of the relative values, (i. e., taking each control value as 1) of all the values obtained, and the regression lines of cell volume, protein and NP-SH are identical, whereas those of NP-SS and P-SH appear to be widely seperated. However, the difference of those two lines (NP-SS & P-SH) were found to be not significant statistically (p>0.05). Therefore, it can be concluded from the above results that all the values examined increase in a lineal fashion with no statistically significant difference among them. Also, with the radiation dose of 1,200 r, the ELD cell becomes enlarged and swollen progressively up to 60 hours post-irradiation and it becomes more than two times of the original normal size at 60 hours after the irradiation, and up to this stage, it seems apparent that the cell division has been slow due to the X-irradiation applied in this experiment. It is well understandable that the contents of NP-SH, NP-SS, P-SH and protein of the ELD cells increase in parallel with the increase of the cell volume by the X-ray does used, but it also seems interesting to note that all the cellular substances tested show no appreciable difference in the pattern of increase.

  • PDF

Composting of the Pig Manure Used with the Ceramic Biocarrier (복합세라믹 담체를 이용한 돈분 퇴비화 연구)

  • Hwang, Joon-Young;Lee, Jong-Eun;Chang, Ki-Woon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.2
    • /
    • pp.110-116
    • /
    • 2003
  • This study was executed to evaluate the utilization and efficiency of the ceramic biocarrier as the promoter of decomposing on the organic matters for the composting using with pig manure by analyzing of the physico-chemical properties during composting. The treatments of this experiment were consisted of the control(C),microorganism(M), M with natural zeolite(M+Z), M with synthesized zeolite(M+SZ), and M with ceramic biocarrier(M+CZ). The process term of composting was conducted for 30days in the rapidly fermented machine(as pilot system). The results of the physico-chemical properties of the composts were as follows. The changes of temperature during composting was not relative with the microorganism and zeolite materials used in the composts. At all of the treatments were similar to changing of temp. from the initial stage to the final stage. But the added microorganism treatments were higher than control. And the entire pH value of treatments were appeared the same that above temperature result, also the M+CZ and M+SZ treatment among the treatment were higher. At the results of T-C, T-N and C/N ratio, in case of T-C value, the M+CZ treatment was highly more decreased than others. However at the T-N value, there were not the differences from the each treatment. And the C/N ratio was changed according to the changes of T-C and T-N value. Especially, at the M+CZ aud M+SZ treatments were remarkably reduced by about 21.4-23.3 value. In the result of G.I for evaluating of the compost humidity, the M+CZ and M+SZ treatments were close up approximately 110 value compared with the control(G.I value 100). Therefore, the examined ceramic biocarrier amended with compost-promoting-bacteria could be applied to the production of many high quality fertilizers. It is also expected that the results of this researches could be applied to the recycle of the organic wastes based on the experimental results of ceramic biocarrier and compost-promoting-bacteria application.

  • PDF

A Study on the Stereotype of ICT SMEs' R&D: Empirical Evidence from Korea (ICT 중소기업 R&D의 스테레오타입에 대한 연구 : 한국의 사례를 중심으로)

  • Jun, Seung-pyo;Choi, San;Jung, JaeOong
    • Journal of Korea Technology Innovation Society
    • /
    • v.20 no.2
    • /
    • pp.334-367
    • /
    • 2017
  • The ICT industry has been the main driver of Korea's economy with international competitiveness and is expected to be the growth engine that will revitalize the currently depressed economy. A broad range of different perspectives and opinions on the industry exist in Korea and overseas. Some of these are stereotypes, not all of which are based on objective evidence. Stereotypes refer to widely-held fixed opinions on a specific group and do not necessarily have negative connotations. However, they should not be viewed lightly because they can substantially affect decision-making process. In this regard, this study sought to review the stereotypes of ICT industry and identify objective and relative stereotypes. In the study, a decision-tree analysis was conducted on a survey result of 3,300 small and medium-sized enterprises (SMEs) in order to identify Korean ICT companies' characteristics that distinguish them from other technology companies. The decision-tree analysis, a data mining process based on machine learning, took a total of 291 variables into account in 10 subjects such as: corporate business in general, technology development activities as well as organization and people in technology development. Identifying the variables that distinguish ICT companies from other technology companies with the decision-tree analysis, the study then came up with a list of objective stereotypes of ICT companies. The findings from the stereotypes of Korean ICT companies are as follows. First, the companies are in need of technology policies that help R&D planning and market penetration. Second, policies must better support the companies working to sell new products or explore new business. Third, the companies need policies that support secure protection of development outcomes and proper management of IP rights. Fourth, the administrative procedures related to governmental support for ICT companies' R&D projects must be simplified. It is hoped that the outcome of this study will provide meaningful guidance in establishment, implementation and evaluation of technology policies for ICT SMEs, particularly to policymakers or researchers in relevant government agencies who determine R&D policies for ICT SMEs.