• 제목/요약/키워드: m_1)-system$

검색결과 13,885건 처리시간 0.049초

과산화수소 증기 시스템을 이용한 미생물 제독에 관한 연구 (A Study on Microorganisms Decontamination Using a Vapor-Phase Hydrogen Peroxide System)

  • 김윤기;김민철;윤성녀;황현철;류삼곤
    • 한국환경보건학회지
    • /
    • 제39권3호
    • /
    • pp.279-288
    • /
    • 2013
  • Objectives: Effectiveness and conditions of vapor-phase hydrogen peroxide (VPHP) system on decontamination of Geobacillus stearothermophilus(GS) spores, Escherichia coli (E.coli) and Enterobacteria phage felix01 (felix01) were determined. Methods: The VPHP system was designed to vaporize 35% (w/w) solution of hydrogen peroxide, continuously to inject and withdraw VPHP. The system and VHP 1000ED (Steris) were operated such that dehumidification and conditioning were initiated without samples in the chamber. Then the samples were loaded into and removed. Coupons (glass, anodizing, silicon, viton) with GS spores ($1{\times}10^6$ colony forming unit/mL [CFU/mL]), E.coli ($1{\times}10^7$ CFU/mL) and felix01 ($1{\times}10^7$ plaque forming unit/mL[PFU/mL]), and Biological Indicator (BI) with GS spores ($1{\times}10^6$ CFU/mL) on stainless steel coupons were used. The tested samples were sonicated and vortexed, and then were plated for enumeration, followed by incubation at $55^{\circ}C$, 24 hr for GS spores, and at $37^{\circ}C$, 24 hr for E.coli and felix01. BI analysis in broth culture was only qualitative. Results: The efficacy of the VPHP system on decontamination was almost equivalent to that of VHP 1000ED. The conditions for complete decontamination with the VPHP system was as follows: concentration; 700~450 ppm, relative humidity; approximately 55%, and temperature; $34{\sim}32^{\circ}C$. When comparing the decontamination efficiency among different kinds of coupons, glass was the most effective, however, all kinds of coupons were decontaminated completely after 60 min exposure in both systems. Conclusion: The VPHP system can be recommended as an alternative system for traditional system using ethylene oxide, formaldehyde or chlorine dioxide.

Response of Soybean (Glycine max L.) to Subsurface Drip Irrigation with Different Dripline Placements at a Sandy-loam Soil

  • Lee, Sanghun;Jung, Ki-Yuol;Chun, Hyen-Chung;Choi, Young-Dae;Kang, Hang-Won
    • 한국토양비료학회지
    • /
    • 제51권2호
    • /
    • pp.79-89
    • /
    • 2018
  • Subsurface drip irrigation (SDI) system is considered one of the most effective methods for water application. A 2-year field study was conducted to investigate the effect of SDI systems with various dripline spacing (0.7 or 1.4 m) and position (under furrow or ridge) on soybean (Glycine max L.) production at a sandy-loam soil in Miryang, South Korea. For 2016-2017, average grain yield in SDI irrigated plots, $3.16Mg\;ha^{-1}$, was statistically greater than rainfed irrigated plot ($2.63Mg\;ha^{-1}$). Soybean grain yield averaged $3.25Mg\;ha^{-1}$ for the 0.7 m dripline spacing and $3.07Mg\;ha^{-1}$ for the 1.4 m spacing for the two-year period compared to a rainfed irrigated average of $2.63Mg\;ha^{-1}$ for the same period. Soybean treated with SDI system had significantly greater values of normalized difference vegetation index and stomatal conductance, indicating that soybean plants in SDI plots had greater photosynthetic and stomatal activity due to the higher water availability in soil. Irrigation water use efficiency (IWUE) was greatest in the plot of 0.7 m spacing installed under ridge position than any other plot across growing season. Average soil water content in plots with 0.7 m dripline spacing was $0.21m^3\;m^{-3}$ at 5 cm depth layer, which was 45% greater compared to the plots with 1.4 m spacing, even though the gross irrigation amounts were greater in 1.4 m spacing plots. It is concluded that wide dripline spacing (1.4 m) is probably the more economical installation design for SDI system compared to 0.7 m spacing in this study soil because the initial cost for dripline may be reduced with wide spacing design, even though the IWUE is greater in the plot of 0.7 m dripline spacing.

옵셋 보정 주기에 따른 망원경 시스템 관측 성능 분석 (Observation Performance Analysis of the Telescope System according to the Offset Compensation Cycle)

  • 이호진;현철;이상욱
    • 한국정보통신학회논문지
    • /
    • 제24권1호
    • /
    • pp.15-21
    • /
    • 2020
  • 본 논문에서는 미확인 우주물체를 감시하기 위해, 전자광학 관측 장비인 망원경 시스템의 관측 성능에 대한 M&S(Modeling & Simulation) 분석을 수행한다. 2개의 망원경 시스템을 활용한 미확인 우주물체 관측에 대한 운용개념을 고려하고, M&S 모델을 구성한다. 관측 운용개념을 바탕으로 초기궤도결정을 수행하여 추정궤도를 생성하고, 추정궤도에 대한 옵셋 보정을 수행하여 보정 주기에 따른 관측 성능을 분석한다. 본 논문의 M&S 분석 결과는 옵셋 보정 주기가 짧을수록 관측 성능이 높게 나타나며, 길어질수록 오차 보정 기회가 줄어들기 때문에 성능이 낮아짐을 보여준다. 그래서 미확인 우주물체 감시를 위한 망원경 시스템의 관측 성능을 높이기 위해서는 초기궤도 추정을 정밀화하거나 옵셋 보정을 지속적으로 수행할 수 있도록 하는 관측 시스템이 구성되어야 한다.

심부 광산의 효율적 환기 시스템에 관한 연구 (A Study of Efficient Ventilation System in Deep Mines)

  • 송두환;김윤광;김택수;김상환
    • 청정기술
    • /
    • 제22권3호
    • /
    • pp.168-174
    • /
    • 2016
  • 석탄 광산의 심부화 및 운행갱도의 증가로 인한 온도상승으로 작업환경이 점차 악화되는 광산에서 작업환경의 개선을 위하여 A광업소를 대상으로 통기평가를 하였으며 갱내의 통기 효율을 증가시키기 위하여 작업장의 온도 저하를 위한 선풍기 통기 방식에 대해 유동해석 프로그램을 이용하여 통기방식에 따른 운반갱도의 온도분포를 해석하였다. 연구결과 A 광업소의 소요환기량은 17,831 m3 min-1으로 산출되었으며, 실제 총 입기량은 16,474 m3 min-1로 환기량이 1,357 m3 min-1 부족한 것으로 나타났고 운반갱도에서 작업장까지의 온도는 송기식 통기보다 배기식 통기방식이 2~3℃ 낮게 분포하였다. 운반갱도에서 작업장까지의 길이가 긴 경우 송기식 보다는 배기식 통기방식을 운용 하는 것이 더욱 효과적일 것이다.

A law of large numbers for maxima in $M/M/infty$ queues and INAR(1) processes

  • Park, Yoo-Sung;Kim, Kee-Young;Jhun, Myoung-Shic
    • Journal of the Korean Statistical Society
    • /
    • 제23권2호
    • /
    • pp.483-498
    • /
    • 1994
  • Suppose that a stationary process ${X_t}$ has a marginal distribution whose support consists of sufficiently large integers. We are concerned with some analogous law of large numbers for such distribution function F. In particular, we determine a weak law of large numbers for maximum queueing length in $M/M\infty$ system. We also present a limiting behavior for the maxima based on AR(1) process with binomial thining and poisson marginals (INAR(1)) introduced by E. Mckenzie. It turns out that the result of AR(1) process is the same as that of $M/M/\infty$ queueing process in limit when we observe the queues at regularly spaced intervals of time.

  • PDF

Optimizing Fat Grafting Using a Hydraulic System Technique for Fat Processing: A Time and Cost Analysis

  • Verdura, Vincenzo;Guastafierro, Antonio;Di Pace, Bruno;Faenza, Mario;Nicoletti, Giovanni Francesco;Rubino, Corrado
    • Archives of Plastic Surgery
    • /
    • 제49권2호
    • /
    • pp.266-274
    • /
    • 2022
  • Background Many authors have researched ways to optimize fat grafting by looking for a technique that offers safe and long-term fat survival rate. To date, there is no standardized protocol. We designed a "hydraulic system technique" optimizing the relationship among the quantity of injected fat, operative time, and material cost to establish fat volume cutoffs for a single procedure. Methods Thirty-six patients underwent fat grafting surgery and were organized into three groups according to material used: standard, "1-track," and "2-tracks" systems. The amount of harvested and grafted fat as well as material used for each procedure was collected. Operating times were recorded and statistical analysis was performed to establish the relationship with the amount of treated fat. Results In 15 cases the standard system was used (mean treated fat 72 [30-100] mL, mean cost 4.23 ± 0.27 euros), in 11 cases the "1-track" system (mean treated fat 183.3 [120-280] mL, mean cost 7.63 ± 0.6 euros), and in 10 cases the "2-tracks" one (mean treated fat 311[220-550] mL, mean cost 12.47 ± 1 euros). The mean time difference between the standard system and the "1-track" system is statistically significant starting from three fat syringes (90 mL) in 17.66 versus 6.87 minutes. The difference between the "1-track" system and "2-tracks" system becomes statistically significant from 240 mL of fat in 15 minutes ("1-track") versus 9.3 minutes for the "2-tracks" system. Conclusion Data analysis would indicate the use of the standard system, "1-track," and "2-tracks" to treat an amount of fat < 90 mL of fat, 90 ÷ 240 mL of fat, and ≥ 240 mL of fat, respectively.

화단형 침투시설의 단위설계침투량 산정 및 효과분석 (Estimation of Appropriate Infiltration Rate and the Effects of the Flowerbed Type Infiltration System)

  • 한영해;이태구
    • 한국조경학회지
    • /
    • 제40권5호
    • /
    • pp.140-147
    • /
    • 2012
  • 본 연구에서는 우수 유출량을 일정수준 이하로 제어할 수 있는 화단형 침투시설을 개발하여 이의 적정 설계침투량을 산정하고 적용효과를 분석하였다. 침투시설의 설계침투량을 산정하고 성능을 분석하는 것은 지구단위계획과 같은 공간계획에 구체적으로 빗물침투시설을 계획할 경우에 적용 후 효과를 예측하는데 있어 반드시 검토되어야 할 사항이다. 이에 본 연구에서는 한국건설기술연구원 실험동 옆 주차장을 대상으로 본 시설의 단위설계침투량에 변화를 주어 물수지 분석 프로그램을 이용, 유출량 감소효과를 분석하였다. 침투시설의 설계침투량을 $0.1{\sim}3m^3/m^2.day$로 각각 변화를 주어 유출율 변화를 분석한 결과, $1.0m^3/m^2.day$에서 유출량 80%를 침투시키는 것으로 분석되었으며, 이때의 단위설계침투량이 0.0416($m^3/m^2.hr$)이었다. 또한 개발한 시스템을 현장침투실험한 결과, 단위설계침투량이 약 $0.045m^3/m^2.hr$으로 나타났다. 이 값은 시뮬레이션한 단위설계침투량과 유사한 것으로 분석되었다. 본 연구결과를 토대로 경제적인 규모와 환경적 효과를 최대한 고려한 침투량 산정이 가능하였으며, 또한 도시에서의 녹색인프라로서 빗물침투시설을 공간계획에 적용할 때 고려할 수 있는 근거를 마련했다는 데 의의를 갖는다.

The Tip-Tilt Correction System in AO System for Gwacheon 1m Telescope

  • 유형준;박용선;계창우
    • 천문학회보
    • /
    • 제38권1호
    • /
    • pp.69.1-69.1
    • /
    • 2013
  • We are developing Adaptive Optics (AO) system for 1m telescope at Gwacheon National Science Museum Observatory. The beam spot of the Gwacheon 1m telescope. The tip-tilt correction system consists of a CMOS sensor, a tip-tilt mirror and a feed back loop. The beam spot location at the CMOS sensor indicates the tip-tilt components of the incoming light. The tip-tilt mirror is controlled by DAC output voltage calculated by proportional-integral-derivative (PID) controller. This system successfully corrects the tip-tilt motion of the spot.

  • PDF

DMB 시스템에서 UWB 전파가 서비스에 미치는 영향에 관한 연구 (A Study of Limitation of Service Area by UWB Transmission Jamming in DMB System)

  • 김동옥
    • 정보통신설비학회논문지
    • /
    • 제4권2호
    • /
    • pp.1-8
    • /
    • 2005
  • 본 논문에서는 UWB 시스템이 근처의 단일 장비 또는 집단 장비와의 간섭영향이 DMB 서비스에 미치는 영향에 관한 연구를 하였다. 이를 위해 UWB 시스템에서 방사되는 불요 방사 레벨에 따른 신호의 간섭을 비롯한 전파 간섭 특성이 인접 대역인 2.6425GHz SDMB(Satellite Digital Multimedia Broadcasting)와, In-band 대역인 3.4125GHz 방송 중계망과 서비스에 미치는 간섭 영향의 정도를 비교 분석하였으며, 방송 중계망과 간섭 측정 장비의 변조방식은 Impulse 방식과 OFDM 방식을 사용하였다. SDMB 시스템에서 Impulse 방식은 2m 지점에서부터 간섭 영향이 발생하여 1.4m 지점에서 방송 신호 수신이 가능한 $BER=1{\times}10^4$ 이었으며, OFDM 방식은 0.8m 지점에서부터 간섭 영향을 받아 0.5m 지점에서 방송 신호 수신이 가능한 $BER=1{\times}10^4$ 이었다. 또한 Gap-Filler 중심 주파수에 대해서는 0.01m 이상 이격 시는 간섭영향이 없었다. 따라서 소출력인 UWB 시스템의 전파가 DMB 서비스에 간섭 영향 없이 시스템에 적용하기 위해서는 Impulse 방식의 UWB 시스템보다 OFDM 방식의 UWB 시스템이 간섭 영향이 적다는 것을 확인하였다.

  • PDF

방송통신 시스템에서 UWB 전파가 서비스에 미치는 영향에 관한 연구 (A Study of Limitation of Service Area by UWB Transmission Jamming in Broadcasting Communication System)

  • 박노진
    • 정보통신설비학회논문지
    • /
    • 제7권1호
    • /
    • pp.23-31
    • /
    • 2007
  • 본 논문에서는 UWB 시스템이 근처의 단일 장비 또는 집단 장비와의 간섭영향이 방송통신서비스에 미치는 영향에 관한 연구를 하였다. 이를 위해 UWB 시스템에서 방사되는 불요 방사 레벨에 따른 신호의 간섭을 비롯한 전파 간섭 특성이 인접 대역인 2.6425GHz SDMB(Satellite Digital Multimedia Broadcasting)와, In-band 대역인 3.4125GHz 방송 중계망과 서비스에 미치는 간섭영향의 정도를 비교 분석하였으며, 방송 중계망과 간섭측정 장비의 변조방식은 Impulse 방식과 OFDM 방식을 사용하였다. SDMB 시스템에서 Impulse 방식은 2m 지점에서부터 간섭 영향이 발생하여 1.4m 지점에서 방송 신호 수신이 가능한 $BER\;=\;1{\times}\;10^{-4}$ 이었으며, OFDM 방식은 0.8m 지점에서부터 간섭 영향을 받아 0.5m 지점에서 방송 신호 수신이 가능한 $BER\;=\;1{\times}\;10^{-4}$ 이었다. 또한 Gap-Filler 중심 주파수에 대해서는 0.01m 이상 이격 시는 간섭영향이 없었다. 따라서 소출력인 UWB 시스템의 전파가 방송통신서비스에 간섭 영향 없이 시스템에 적용하기 위해서는 Impulse 방식의 UWB 시스템보다 OFDM 방식의 UWB 시스템이 간섭 영향이 적다는 것을 확인하였다.

  • PDF