A Study on Microorganisms Decontamination Using a Vapor-Phase Hydrogen Peroxide System

과산화수소 증기 시스템을 이용한 미생물 제독에 관한 연구

  • Received : 2013.04.10
  • Accepted : 2013.05.15
  • Published : 2013.06.30

Abstract

Objectives: Effectiveness and conditions of vapor-phase hydrogen peroxide (VPHP) system on decontamination of Geobacillus stearothermophilus(GS) spores, Escherichia coli (E.coli) and Enterobacteria phage felix01 (felix01) were determined. Methods: The VPHP system was designed to vaporize 35% (w/w) solution of hydrogen peroxide, continuously to inject and withdraw VPHP. The system and VHP 1000ED (Steris) were operated such that dehumidification and conditioning were initiated without samples in the chamber. Then the samples were loaded into and removed. Coupons (glass, anodizing, silicon, viton) with GS spores ($1{\times}10^6$ colony forming unit/mL [CFU/mL]), E.coli ($1{\times}10^7$ CFU/mL) and felix01 ($1{\times}10^7$ plaque forming unit/mL[PFU/mL]), and Biological Indicator (BI) with GS spores ($1{\times}10^6$ CFU/mL) on stainless steel coupons were used. The tested samples were sonicated and vortexed, and then were plated for enumeration, followed by incubation at $55^{\circ}C$, 24 hr for GS spores, and at $37^{\circ}C$, 24 hr for E.coli and felix01. BI analysis in broth culture was only qualitative. Results: The efficacy of the VPHP system on decontamination was almost equivalent to that of VHP 1000ED. The conditions for complete decontamination with the VPHP system was as follows: concentration; 700~450 ppm, relative humidity; approximately 55%, and temperature; $34{\sim}32^{\circ}C$. When comparing the decontamination efficiency among different kinds of coupons, glass was the most effective, however, all kinds of coupons were decontaminated completely after 60 min exposure in both systems. Conclusion: The VPHP system can be recommended as an alternative system for traditional system using ethylene oxide, formaldehyde or chlorine dioxide.

Keywords

References

  1. McDonnell G, Russell AD. Antiseptics and disinfectants: activity, action, and resistance. Clinical microbiology reviews. 1999; 12(1): 147-179.
  2. Melly E, Cowan AE, Setlow P. Studies on the mechanism of killing of Bacillus subtilis spores by hydrogen peroxide. Journal of applied microbiology. 2002; 93(2): 316-325. https://doi.org/10.1046/j.1365-2672.2002.01687.x
  3. Grare M, Dailloux M, Simon L, Dimajo P, Laurain C. Efficacy of dry mist of hydrogen peroxide (DMHP) against Mycobacterium tuberculosis and use of DMHP for routine decontamination of biosafety level 3 laboratories. Journal of clinical microbiology. 2008; 46(9): 2955-2958. https://doi.org/10.1128/JCM.00250-08
  4. Fichet G, Comoy E, Duval C, et al. Novel methods for disinfection of prion-contaminated medical devices. Lancet. 2004; 364(9433): 521-526. https://doi.org/10.1016/S0140-6736(04)16810-4
  5. French GL, Otter JA, Shannon KP, Adams NM, Watling D, Parks MJ. Tackling contamination of the hospital environment by methicillin-resistant Staphylococcus aureus (MRSA): a comparison between conventional terminal cleaning and hydrogen peroxide vapour decontamination. The Journal of hospital infection. 2004; 57(1): 31-37. https://doi.org/10.1016/j.jhin.2004.03.006
  6. Heckert RA, Best M, Jordan LT, Dulac GC, Eddington DL, Sterritt WG. Efficacy of vaporized hydrogen peroxide against exotic animal viruses. Applied and environmental microbiology. 1997; 63(10): 3916-3918.
  7. Johnston MD, Lawson S, Otter JA. Evaluation of hydrogen peroxide vapour as a method for the decontamination of surfaces contaminated with Clostridium botulinum spores. Journal of microbiological methods. 2005; 60(3): 403-411. https://doi.org/10.1016/j.mimet.2004.10.021
  8. Quilez J, Sanchez-Acedo C, Avendano C, del Cacho E, Lopez-Bernad F. Efficacy of two peroxygen- based disinfectants for inactivation of Cryptosporidium parvum oocysts. Applied and environmental microbiology. 2005; 71(5): 2479-2483. https://doi.org/10.1128/AEM.71.5.2479-2483.2005
  9. Klapes NA, Vesley D. Vapor-phase hydrogen peroxide as a surface decontaminant and sterilant. Applied and environmental microbiology. 1990; 56(2): 503-506.
  10. Otter JA, French GL. Survival of nosocomial bacteria and spores on surfaces and inactivation by hydrogen peroxide vapor. Journal of clinical microbiology. 2009; 47(1): 205-207. https://doi.org/10.1128/JCM.02004-08
  11. Pottage T, Macken S, Giri K, Walker JT, Bennett AM. Low-temperature decontamination with hydrogen peroxide or chlorine dioxide for space applications. Applied and environmental microbiology. 2012; 78(12): 4169-4174. https://doi.org/10.1128/AEM.07948-11
  12. Krause J, McDonnell G, Riedesel H. Biodecontamination of animal rooms and heat-sensitive equipment with vaporized hydrogen peroxide. Contemporary topics in laboratory animal science / American Association for Laboratory Animal Science. 2001; 40(6): 18-21.
  13. Pottage T, Richardson C, Parks S, Walker JT, Bennett AM. Evaluation of hydrogen peroxide gaseous disinfection systems to decontaminate viruses. The Journal of hospital infection. 2010; 74(1): 55-61. https://doi.org/10.1016/j.jhin.2009.08.020
  14. Watling D, Ryle C, Parks M, Christopher M. Theoretical analysis of the condensation of hydrogen peroxide gas and water vapour as used in surface decontamination. PDA journal of pharmaceutical science and technology / PDA. 2002; 56(6): 291-299.
  15. Hose JE, Di Fiore D, Parker HS, Sciarrotta T. Toxicity of chlorine dioxide to early life stages of marine organisms. Bulletin of environmental contamination and toxicology. 1989; 42(3): 315-319. https://doi.org/10.1007/BF01699954
  16. Sagripanti JL, Carrera M, Insalaco J, Ziemski M, Rogers J, Zandomeni R. Virulent spores of Bacillus anthracis and other Bacillus species deposited on solid surfaces have similar sensitivity to chemical decontaminants. Journal of applied microbiology. 2007; 102(1): 11-21. https://doi.org/10.1111/j.1365-2672.2006.03235.x
  17. Otter JA, Yezli S. Are commercially available Geobacillus stearothermophilus biological indicators an appropriate standard for hydrogen peroxide vapour systems in hospitals? The Journal of hospital infection. 2012; 80(3): 272-273.
  18. Rogers JV, Sabourin CL, Choi YW, et al. Decontamination assessment of Bacillus anthracis, Bacillus subtilis, and Geobacillus stearothermophilus spores on indoor surfaces using a hydrogen peroxide gas generator. Journal of applied microbiology. 2005; 99(4): 739-748. https://doi.org/10.1111/j.1365-2672.2005.02686.x
  19. Greenberg DL, Busch JD, Keim P, Wagner DM. Identifying experimental surrogates for Bacillus anthracis spores: a review. Investigative genetics. 2010; 1(1): 4. https://doi.org/10.1186/2041-2223-1-4
  20. Lalain TA, Brickhouse MD, Dfarr JW. Biological Warfare Agent Decontamination Efficacy Testing: Large-Scale Chamber mVHP Decontamination System Evaluation For Biological Contamination. EDGEWOOD Chemical Biological Center Press. 2007; 1-42.
  21. Krishnan J, Berry J, Fey G, Wagener S. Vaporized Hydrogen Peroxide-based Biodecontamination of a High-Containment Laboratory under Negative Pressure. Applied Biosafety. 2006; 11(2): 74-80. https://doi.org/10.1177/153567600601100203