Different kinds of cytokinins and auxins were tested for both shoot induction and rooting in a rare species, Abeliophyllum distichum Nakai. BA in WPM medium was the most effective in shoot induction, whereas zeatin seemed to be the most suitable for shoot elongation. Kinetin, at the concentration of 2.0~5.0 mg/L showed an effect in shoot induction, but the effect was inferior to BA and zeatin. Rapid shoot elongation could be achieved when the cultures were maintained on the diffuse light condition (below 500 lux) regardless of cytokinin treatments. For in vitro rooting, IBA was investigated as the best type of auxin tested when half strength GD medium was incorporated. The frequency of rooting using the plant growth regulator and medium just mentioned above was revealed as approximately 90%. In addition, the survival rate of rooted plantlets was almost 100% in an artificial soil mixture.
Effects of dark adaptation have large safety implications. This study was aimed to investigate the effects of varying illuminance and the size of critical detail on visual performance (i.e., time-to-detect) in a dark room environment. While adapting to the dark environment, ten subjects were asked to detect and answer simple numerical expressions under 9 experimental conditions (3 illuminance level $\times$ 3 target size). The ANOVA results revealed that the time-to-detect was significantly affected by both of the illumination level and the size of critical detail. As illumination increased from 10 lux to 20 lux, the time-to-detect was significantly declined. For the size of critical detail, 0.5/min size (i.e., equal to 2 minutes of visual angle) resulted in a shorter time-to-detect, as compared to 0.7/min size (i.e., equal to 1.6 minutes of visual angle). Potential applications of this research include the development of design guidelines for illumination and warning signs in poorly illuminated viewing environments.
Microbial whole-cell biosensors can be excellent analytical tools for monitoring environmental pollutants. They are constructed by fusing reporter genes (e.g., lux, gfp or lacZ) to inducible regulatory genes which are responsive to the relevant pollutants, such as aromatic hydrocarbons and heavy metals. A large spectrum of microbial biosensors has been developed using recombinant DNA technology and applied in fields as diverse as environmental monitoring, medicine, food processing, agriculture, and defense. Furthermore, their sensitivity and target range could be improved by modification of regulatory genes. Recently, microbial biosensor cells have been immobilized on chips, optic fibers, and other platforms of high-throughput cell arrays. This paper reviews recent advances and future trends of genetically modified microbial biosensors used for monitoring of specific environmental pollutants.
The purpose of this study is to execute evaluation experiment to know the evaluation property of lighting environment of residential space for senior people, considering visual characteristics along aging, and finally provide basic data for the lighting plan to ensure the visual amenity. Processes of this study are as follows;1) Analyzed the variation property of visual sensibility and visual ability of senior people along aging. 2) Selected 3 types of life behavior(rest, conversation and reading) after checking life behavior in residential space for senior people based on advanced study. 3) Made the Mock-up Model that Dimming is possible, actual furnace to model. 4) Executed sensitivity evaluation experiment about lighting environment. 5) Analyzed evaluation property of lighting environment of residential space for senior people. Results of this study are as follows, 1) With lens-filter, we got comfort and amenity in bulb-color lamp which has similar color temperature with red of lens filter. 2) Lighting environment tests during conversation : With lens filters, they felt comfort on bulb color in case of higher illuminance than 850lux and daylight color in 500lux. 3) Lighting environment tests at reading : With lens filter, bulb color got better score in brightness and appropriateness than daylight color.
Dark and desolate underground parking spaces in commercial facilities are optimal spaces for crime. First, this study reviewed 15 precedent CPTED guidelines and related literatures, and as a result extracted 45 CPTED planning criteria for underground parking facilities. Secondly by field survey, we investigated six parking spaces in commercial facilities whether they were planned properly based on 45 checklist items, in six categories of CPTED principles. In result, target facilities showed average 46.8% relevance ratio, which means less than a half of 45 items of CPTED planning factors were not applied. Guidelines suggest desirable illuminance level of more than 100 lux, however the measurement of illuminance levels in some parking spaces showed below 50 lux. Relatively department stores were keeping CPTED guidelines better than large discount mart and mixed used facilities. Definition of territory of loading dock and customer area should be clarified, clear signage and color scheme in different zones should be represented with higher level of territorial responsibilities and surveillance in mixed used facilities for further improvement.
Journal of the Korean Institute of Plant Engineering
/
v.23
no.4
/
pp.51-56
/
2018
Computed tomography (CT) scan room in the department of radiology is very necessary to maintain pleasant and proper illuminance to relieve fatigue and inconvenience because it affects the work environment to the radiologist. Accordingly, this paper describes the method for measurement of illuminance that exposed to an environmental elements in a CT scan room of the hospital. Therefore, the purpose of this paper is to propose an optimal environment of CT scan room based on the measurement of illuminance. In addition, the 5 point method by KS C7612 was applied to measure the illuminance with illuminometer (Unfors xi light probe) in the CT scan room. In result of this paper, minimum value and maximum value of illuminance in the CT scan room was measured 212.7 lux and 354.8 lux, respectively. The illuminance of CT scan room was lower than KS A 3011. Finally, the work environment in CT scan room should provide higher illuminance for the comfortable environment of radiologists and patients.
Journal of the Architectural Institute of Korea Planning & Design
/
v.35
no.1
/
pp.99-106
/
2019
This study aims to recommend the proper Color rendering index (CRI), the Correlated Color Temperature (CCT), and illuminance levels of Light-Emitting Diode (LED) lighting based on the analysis of the criteria of the current CRI, the CCT, and illuminance levels in merchandising spaces with LED lighting conditions. It would be a basic material to apply in line with user preference for LED merchandising lighting. To this end, it examines relevant literature review on the experiments designed to test whether lighting characteristics affect brightness perception, color appearance, and pleasantness. Highly saturated colors appear brighter than low saturated colors. Two lighting applications - grocery and clothing shop - were created in elaborating the effect of LED lighting characteristics of CRI on color appearance and the CCT and illuminance on pleasantness. The findings show that the criteria of CIE Ra<80 are appropriate to provide better color appearance of illuminated products in terms of LED lighting that can enhance color saturation, particularly for the red color. Furthermore, 2700 K and less than 500 lux for grocery, 4000 K and more than 500 lux for clothing shop are found to be the proper the CCT and illuminance levels respectively to bring better preference under LED lighting.
Kanojiya, Poonam;Banerji, Rajashri;Saroj, Sunil D.
Microbiology and Biotechnology Letters
/
v.50
no.1
/
pp.1-14
/
2022
Bacteria communicate with each other through an intricate communication mechanism known as quorum sensing (QS). QS regulates different behavioral aspects in bacteria, such as biofilm formation, sporulation, virulence gene expression, antibiotic production, and bioluminescence. Several different chemical signals and signal detection systems play vital roles in promoting highly efficient intra- and interspecies communication. Gram-negative bacteria coordinate gene regulation through the production of acyl homoserine lactones (AHLs). Gram-positive bacteria do not code for AHL production, while some gram-negative bacteria have an incomplete AHL-QS system. Despite this fact, these microbes can detect AHLs owing to the presence of LuxR solo receptors. Various studies have reported the role of AHLs in interspecies signaling. Moreover, as bacteria live in a polymicrobial community, the production of extracellular compounds to compete for resources is imperative. Thus, AHL-mediated signaling and inhibition are considered to affect virulence in bacteria. In the current review, we focus on the synthesis and regulation mechanisms of AHLs and highlight their role in interspecies bacterial signaling. Exploring interspecies bacterial signaling will further help us understand host-pathogen interactions, thereby contributing to the development of therapeutic strategies intended to target chronic polymicrobial infections.
Considering the greater role of α-amino acids in our daily lives, the enantiomer resolution of seven α-amino acids derivatized with fluorogenic reagent (4-fluoro-7-nitro-2,1,3-benzoxadiazole, NBD-F) by chiral HPLC on amylose or cellulose trisphenylcarbamate derived chiral stationary phases (CSPs) under simultaneous ultraviolet (UV) and fluorescence (FL) detection was performed. The degree of enantioseparation and resolution was affected by nature and selector backbones of the CSPs as well as the kind of amino acids. Baseline enantiomer separation and resolutions were observed for the enantiomers of all analytes as NBD derivatives especially on coated type amylose tris(3,5-dimethylphenylcarbamate) derived CSPs (Chiralpak AD-H and Lux Amylose-1). The other CSPs also showed good enantioselectivity except for the CSPs (Chiralpak IB, Chiralcel OD-H and Lux Cellulose-1) having cellulose tris(3,5-dimethylphenylcarbamate) as chiral selectors. The developed analytical chiral method was applied to determine the enantiomeric purity of seven commercially available L-α-amino acids and the impurities as D-forms were found to be in the range 0.08-0.87 %, respectively. The intra- and interday accuracy and precision assays showed high accuracy and precision of the developed analytical method. This chiral HPLC method for the enantiomer resolution of amino acids using fluorescent derivatization could be useful for the determination of enantiomeric purity of pharmaceuticals and biological study for amino acid type compounds among chiral drugs.
Kang, Duk-Young;Kim, Won-Jin;Kim, Hyo-Chan;Chang, Young Jin
Korean Journal of Ichthyology
/
v.26
no.3
/
pp.185-193
/
2014
To find the influence of water temperature, tank color and illumination in feeding, growth and blind-side hypermelanosis of starry flounder, Platichthys stellatus, in the present study, we performed a series of temperature, background color and illumination intensity test for 180 days (From June to December). The test was done in duplicate at 100 fish/tank (430% of initial covering area [PCA]) with the selected ordinary juvenile flounder (TL $17.3{\pm}0.5cm$, BW $82.5{\pm}0.2g$). The rearing was performed in darkgreen FRP aquarium tanks ($H100cm{\times}L100cm{\times}W100cm$; bottom area $1m^2$) lighten with average 1,000 lux and 230 lux, and in white FRP aquarium tank ($H100cm{\times}L100cm{\times}W100cm$; bottom area $1m^2$) lighten with average 230 lux of light intensity. We investigated correlation of daily food intake (DFI) with water temperature and salinity, and compared the influences of background colors and light intensity in DFI, food efficiency (FE), growth, survival rate, and ratio of malpigmented blind-side area and ambicolored fish ratio. In DFI, although it was not related with salinity, the amount was significantly decreased under 0.5 g/fish/day in summer and winter season, but was significantly increased over 1.5 g/fish/day in autumn season showing from $10^{\circ}C$ to $20^{\circ}C$ in water temperature. In background and illumination test, DFI, FE and survival rate showed no difference among three groups. The ratios of malpigmented blind-side area and ambicolored fish were also not significantly different among three groups, indicating that the blind-side hypermelanosis of starry may be governed not by background color (or light intensity) but by a genetics external trait inherited from parents.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.