• 제목/요약/키워드: luting

검색결과 135건 처리시간 0.025초

The effect of individualization of fiberglass posts using bulk-fill resin-based composites on cementation: an in vitro study

  • Lins, Rodrigo Barros Esteves;Cordeiro, Jairo Matozinho;Rangel, Carolina Perez;Antunes, Thiago Bessa Marconato;Martins, Luis Roberto Marcondes
    • Restorative Dentistry and Endodontics
    • /
    • 제44권4호
    • /
    • pp.37.1-37.10
    • /
    • 2019
  • Objectives: This study evaluated the bond strength of various fiberglass post cementation techniques using different resin-based composites. Materials and Methods: The roots from a total of 100 bovine incisors were randomly assigned to 5 treatment groups: G1, post + Scotchbond Multi-Purpose (SBMP) + RelyX ARC luting agent; G2, relined post (Filtek Z250) + SBMP + RelyX ARC; G3, individualized post (Filtek Z250) + SBMP; G4, individualized post (Filtek Bulk-Fill) + SBMP; G5, individualized post (Filtek Bulk-Fill Flow) + SBMP. The samples were subjected to the push-out (n = 10) and pull-out (n = 10) bond strength tests. Data from the push-out bond strength test were analyzed using 2-way analysis of variance (ANOVA) with the Bonferroni post hoc test, and data from the pull-out bond strength test were analyzed using 1-way ANOVA. Results: The data for push-out bond strength presented higher values for G2 and G5, mainly in the cervical and middle thirds, and the data from the apical third showed a lower mean push-out bond strength in all groups. No significant difference was noted for pull-out bond strength among all groups. The most frequent failure modes observed were adhesive failure between dentine and resin and mixed failure. Conclusions: Fiberglass post cementation using restorative and flowable bulk-fill composites with the individualization technique may be a promising alternative to existing methods of post cementation.

풀지르코니아 수복물의 실용성과 전망 (Practicality and prospect of full-zirconia restoration)

  • 황정원
    • 대한심미치과학회지
    • /
    • 제24권2호
    • /
    • pp.101-121
    • /
    • 2015
  • 지르코니아 폴리크리스탈은 (Y-TZP) 다른 치과용 세라믹에 비해 기계적 강도와 파절저항성이 우수하다. 지르코니아 기반 세라믹은 캐드캠 시스템을 바탕으로 고정식 수복물 제작에 성공적으로 소개되어 왔다. 이는 고정식 수복물을 위한 금속 구조물의 임상적 대안으로 제시되었다. 지르코니아 수복물의 가장 흔한 합병증은 상부 도재의 파절이다. 다른 옵션은 고도로 반투명한 지르코니아를 전부지르코니아 고정식 수복물로 사용하는 것이다. 본 논문에서는 전부지르코니아 수복물의 장점, 지르코니아 수복물의 임상적용, 지대치 삭제, 대합치 마모, 지르코니아와 레진시멘트와의 접착, 그리고 기공소와의 의사소통에 관하여 보고하였다.

Influence of nano-structured alumina coating on shear bond strength between Y-TZP ceramic and various dual-cured resin cements

  • Lee, Jung-Jin;Choi, Jung-Yun;Seo, Jae-Min
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권2호
    • /
    • pp.130-137
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the effect of nano-structured alumina surface coating on shear bond strength between Y-TZP ceramic and various dual-cured resin cements. MATERIALS AND METHODS. A total of 90 disk-shaped zirconia specimens (HASS CO., Gangneung, Korea) were divided into three groups by surface treatment method: (1) airborne particle abrasion, (2) tribochemicalsilica coating, and (3) nano-structured alumina coating. Each group was categorized into three subgroups of ten specimens and bonded with three different types of dual-cured resin cements. After thermocycling, shear bond strength was measured and failure modes were observed through FE-SEM. Two-way ANOVA and the Tukey's HSD test were performed to determine the effects of surface treatment method and type of cement on bond strength (P<.05). To confirm the correlation of surface treatment and failure mode, the Chi-square test was used. RESULTS. Groups treated with the nano-structured alumina coating showed significantly higher shear bond strength compared to other groups treated with airborne particle abrasion or tribochemical silica coating. Clearfil SA Luting showed a significantly higher shear bond strength compared to RelyX ARC and RelyX Unicem. The cohesive failure mode was observed to be dominant in the groups treated with nano-structured alumina coating, while the adhesive failure mode was prevalent in the groups treated with either airborne particle abrasion or tribochemical silica coating. CONCLUSION. Nano-structured alumina coating is an effective zirconia surface treatment method for enhancing the bond strength between Y-TZP ceramic and various dual-cured resin cements.

The selection criteria of temporary or permanent luting agents in implant-supported prostheses: in vitro study

  • Alvarez-Arenal, Angel;Gonzalez-Gonzalez, Ignacio;deLlanos-Lanchares, Hector;Brizuela-Velasco, Aritza;Ellacuria-Echebarria, Joseba
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권2호
    • /
    • pp.144-149
    • /
    • 2016
  • PURPOSE. The use of temporary or permanent cements in fixed implant-supported prostheses is under discussion. The objective was to compare the retentiveness of one temporary and two permanent cements after cyclic compressive loading. MATERIALS AND METHODS. The working model was five solid abutments screwed to five implant analogs. Thirty Cr-Ni alloy copings were randomized and cemented to the abutments with one temporary (resin urethane-based) or two permanent (resin-modified glass ionomer, resin-composite) cements. The retention strength was measured twice: once after the copings were cemented and again after a compressive cyclic loading of 100 N at 0.72 Hz (100,000 cycles). RESULTS. Before loading, the retention strength of resin composite was 75% higher than the resin-modified glass ionomer and 2.5 times higher than resin urethane-based cement. After loading, the retentiveness of the three cements decreased in a non-uniform manner. The greatest percentage of retention loss was shown by the temporary cement and the lowest by the permanent resin composite. However, the two permanent cements consistently show high retention values. CONCLUSION. The higher the initial retention of each cement, the lower the percentage of retention loss after compressive cyclic loading. After loading, the resin urethane-based cement was the most favourable cement for retrieving the crowns and resin composite was the most favourable cement to keep them in place.

Early complications and performance of 327 heat-pressed lithium disilicate crowns up to five years

  • Huettig, Fabian;Gehrke, Ulf Peter
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권3호
    • /
    • pp.194-200
    • /
    • 2016
  • PURPOSE. The prospective follow-up aimed to assess the performance of lithium disilicate crowns and clinical reasons of adverse events compromising survival and quality. MATERIALS AND METHODS. 58 patients were treated with 375 heat-pressed monolithic crowns, which were bonded with resin cement. Annual recalls up to five years included a complete dental examination as well as quality assessment using CDA-criteria. Any need for clinical intervention led to higher complication rate and any failure compromised the survival rate. Kaplan-Meier-method was applied to all crowns and a dataset containing one randomly selected crown from each patient. RESULTS. Due to drop-outs, 45 patients (31 females, 14 males) with the average age of 43 years (range = 17-73) who had 327 crowns (176 anterior, 151 posterior; 203 upper jaw, 124 lower jaw) were observed and evaluated for between 4 and 51 months (median = 28). Observation revealed 4 chippings, 3 losses of retention, 3 fractures, 3 secondary caries, 1 endodontic problem, and 1 tooth fracture. Four crowns had to be removed. Survival and complication rate was estimated 98.2% and 5.4% at 24 months, and 96.8% and 7.1% at 48 months. The complication rate was significantly higher for root canal treated teeth (12%, P<.01) at 24 months. At the last observation, over 90% of all crowns showed excellent ratings (CDA-rating Alfa) for color, marginal fit, and caries. CONCLUSION. Heat pressed lithium disilicate crowns showed an excellent performance. Besides a careful luting, dentists should be aware of patients' biological prerequisites (grade of caries, oral hygiene) to reach full success with these crowns.

The effect of silane applied to glass ceramics on surface structure and bonding strength at different temperatures

  • Yavuz, Tevfik;Eraslan, Oguz
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권2호
    • /
    • pp.75-84
    • /
    • 2016
  • PURPOSE. To evaluate the effect of various surface treatments on the surface structure and shear bond strength (SBS) of different ceramics. MATERIALS AND METHODS. 288 specimens (lithium-disilicate, leucite-reinforced, and glass infiltrated zirconia) were first divided into two groups according to the resin cement used, and were later divided into four groups according to the given surface treatments: G1 (hydrofluoric acid (HF)+silane), G2 (silane alone-no heat-treatment), G3 (silane alone-then dried with $60^{\circ}C$ heat-treatment), and G4 (silane alonethen dried with $100^{\circ}C$ heat-treatment). Two different adhesive luting systems were applied onto the ceramic discs in all groups. SBS (in MPa) was calculated from the failure load per bonded area (in $N/mm^2$). Subsequently, one specimen from each group was prepared for SEM evaluation of the separated-resin-ceramic interface. RESULTS. SBS values of G1 were significantly higher than those of the other groups in the lithium disilicate ceramic and leucite reinforced ceramic, and the SBS values of G4 and G1 were significantly higher than those of G2 and G3 in glass infiltrated zirconia. The three-way ANOVA revealed that the SBS values were significantly affected by the type of resin cement (P<.001). FIN ceramics had the highest rate of cohesive failure on the ceramic surfaces than other ceramic groups. AFM images showed that the surface treatment groups exhibited similar topographies, except the group treated with HF. CONCLUSION. The heat treatment was not sufficient to achieve high SBS values as compared with HF acid etching. The surface topography of ceramics was affected by surface treatments.

여성에서 절식이 체지방과 혈청의 Leptin 및 지질조성에 미치는 영향 (Effect of Complete Fasting on Body Fatness, Serum Leptin and Lipid Profile in Women)

  • 이은옥;박현서;신현대
    • Journal of Nutrition and Health
    • /
    • 제33권1호
    • /
    • pp.42-48
    • /
    • 2000
  • The study was designed to observe the effect of complete listing for 10 days on body fatness, serum leptin level and lipid profile in thirty women who were admitted to fasting Clinical Program in Kyung-Hee Oriental Medical Center. Most of the subjects had food habits of over-eating and preferred oily foods which was correlated to the increase of body weight and BMI during realimentation. Average loss of body weight was 7.98kg and waist-hip ratio was significantly decreased during fasting. Body weight showed significant positive correlation with body fat(r=0.8182), lean body mass(r=0.7797) and total body water(r=0.7563). Body fat was gradually reduced after 9 days fasting, but lean body mass was not diminished any more after 7 days luring. Serum leptin level was significantly decreased after luring and re-feeding. The leptin showed significant positive correlation with body weight(r=0.9324), body mass index(r=0.8279) and body fat(r=0.8376). The levels of serum total cholesterol and LDL-C were significantly increased but HDL-C level was significantly decreased after fasting which increased could be harmful for persons with hypercholesterolemia. VLDL-C and triglyceride levels were not significantly decreased after fasting. Serum total free fatty acid level was significantly increased after fasting. These data suggest that the best way of maintaining the reduced body weight was to carry out the modification of food habits and behavior in daily lift. It could not be recommended to repeat often complete luting for reduction of body weight. (Korean J Nutrition 33(1) : 42-48, 2000)

  • PDF

임시접착 후, 치면세마에 따른 Lithium Disilicate Glass-Ceramic의 레진결합강도에 대한 연구 (Resin Bond Strength of Lithium Disilicate Glass-Ceramic by Surface Cleansing Method after Temporary Cementation)

  • 정승화;이진한;오상천
    • 구강회복응용과학지
    • /
    • 제23권3호
    • /
    • pp.259-268
    • /
    • 2007
  • purpose: This study was to evaluate the shear bond strength of Lithium Disilicate Glass-Ceramic by removable method of temporary cement on the abutment tooth. Material and Method: Sixty molar teeth of human with the occlusal surface up were mounted in acrylic resin blocks. The 45 specimens were prepared to exposure dentin by diamond bur and the eugenol-containing temporary cement($Cavitec^{TM}$ ($KERR^{(R)}$, U.S.A)was applied to the dentin surfaces. After initial removal of the cement with a dental explorer, the specimens were divided into 4 groups of 15 specimens each. The dentin surfaces of the specimens were treated by rotary instrument with as follow pastes: $Zircate^{(R)}$ prophy paste(Dentsply, U.S.A), Radent Prophy Paste(Pascal company,inc. U.S.A), and Dental pumice(Wip mix corporation,U.S.A). An adhesive resin luting agent(Variolink $II^{(R)}$, Ivoclar Vivadent, Leichtenstein) including Monobond-S and $Excite^{(R)}$ was applied to all specimens. The ceramic specimens were made with an A1 ingot of IPS Empress $II^{(R)}$ (Ivoclar Vivadent, Leichtenstein). After the specimens were stored in distilled water for 48hr, the shear bond strength(MPa) was measured by a Universal testing machine(Zwick 145641, Zwick, Germany) at a 1mm/min cross-head speed. The data were statistically analyzed by one-way ANOVA and Duncan's multiple range test. Results: In all group, there were no significant differences in comparison with the control group(p>0.05). The pattern of most failure showed the mixed type of cohesive and adhesive failure. Conclusion: Resin bond strength of IPS Empress $II^{(R)}$ was not affected by removal method of the temporary cement.

시멘트 유지형 임플란트 지대주의 높이와 축면경사도가 보철물의 유지력에 미치는 영향 (Effect of different abutment height and convergence taper on the retention of crowns cemented onto implant-supported prostheses)

  • 변태희;김부섭;정인성
    • 대한치과기공학회지
    • /
    • 제30권1호
    • /
    • pp.57-63
    • /
    • 2008
  • The purpose of this study was to ascertain the effect of different abutment height and different taper of abutment on retention force of cemented implant-supported prostheses. Test specimens consisted of different abutment height group(3mm, 4mm, 5mm, 6mm, 7mm) and different taper(degrees) abutment group($4^{\circ},\;5^{\circ},\;6^{\circ},\;7^{\circ},\;8^{\circ}$). The surfaces of abutments and crowns were manufactured and finished by automatic lathe(CNC). Luting cement(Tokuso Ionomer) was prepared according to the manufacturer's instruction. And the cylinders were sealed onto the abutments and loaded in compression at 5kg for 10minutes. Excess cement was removed from the abutment-cylinder junction and the specimens were stored at room temparature for 24 hours. Specimens were tested in tension using a universal testing machine. Within the limits of this study, the following conclusions were drawn: 1. The increase in abutment height result in improvement in retention strength(P<0.05). 2. The increase in taper of abutment result in decrease in retention strength(P<0.05). 3. The decrease in abutment height result in decrease in retention strength, besides has a significantly lower retention strength at 3mm abutment height. 4. The increase in taper of abutment result in decrease in retention strength, besides has a significantly lower retention strength at $7^{\circ}$ abutment.

  • PDF

The effect of light sources and CAD/CAM monolithic blocks on degree of conversion of cement

  • Cetindemir, Aydan Boztuna;Sermet, Bulent;Ongul, Deger
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.291-299
    • /
    • 2018
  • PURPOSE. To assess the degree of conversion (DC) and light irradiance delivered to light-cured and dual-cured cements by application of different light sources through various types of monolithic computer-aided design and computer-aided manufacturing (CAD/CAM) materials. MATERIALS AND METHODS. RelyX Ultimate Clicker light-cured and dual-cured resin cement specimens with 1.5-mm thicknesses (n=300, 10/group), were placed under four types of crystalline core structure (Vita Enamic, Vita Suprinity, GC Ceresmart, Degudent Prettau Anterior). The specimens were irradiated for 40 seconds with an LED Soft-Start or pulse-delay unit or 20 seconds with a QTH unit. DC ratios were determined by using Fourier transform infrared spectroscopy (FTIR) after curing the specimen at 1 day and 1 month. The data were analyzed using the Mann-Whitney U test (for paired comparison) and the Kruskal-Wallis H test (for multiple comparison), with a significance level of P<.05. RESULTS. DC values were the highest for RelyX Ultimate Clicker light-cure specimens polymerized with the LED Soft-Start unit. The combination of the Vita Suprinity disc and RelyX Ultimate Clicker dual-cure resin cement yielded significantly higher values at both timepoints with all light units (all, P<.05). CONCLUSION. Within the limitations of this study, we conclude that the DC of RelyX Ultimate Clicker dual-cure resin cement was improved significantly by the use of Vita Suprinity and the LED Soft-Start light unit. We strongly recommend the combined use of an LED light unit and dual-cure luting cement for monolithic ceramic restorations.