Evaluation of Planning Dose Accuracy in Case of Radiation Treatment on Inhomogeneous Organ Structure (불균질부 방사선치료 시 계획 선량의 정확성 평가)

  • Kim, Chan Yong;Lee, Jae Hee;Kwak, Yong Kook;Ha, Min Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.137-143
    • /
    • 2013
  • Purpose: We are to find out the difference of calculated dose of treatment planning system (TPS) and measured dose in case of inhomogeneous organ structure. Materials and Methods: Inhomogeneous phantom is made with solid water phantom and cork plate. CT image of inhomogeneous phantom is acquired. Treatment plan is made with TPS (Pinnacle3 9.2. Royal Philips Electronics, Netherlands) and calculated dose of point of interest is acquired. Treatment plan was delivered in the inhomogeneous phantom by ARTISTE (Siemens AG, Germany) measured dose of each point of interest is obtained with Gafchromic EBT2 film (International Specialty Products, US) in the gap between solid water phantom or cork plate. To simulate lung cancer radiation treatment, artificial tumor target of paraffin is inserted in the cork volume of inhomogeneous phantom. Calculated dose and measured dose are acquired as above. Results: In case of inhomogeneous phantom experiment, dose difference of calculated dose and measured dose is about -8.5% at solid water phantom-cork gap and about -7% lower in measured dose at cork-solid water phantom gap. In case of inhomogeneous phantom inserted paraffin target experiment, dose difference is about 5% lower in measured dose at cork-paraffin gap. There is no significant difference at same material gap in both experiments. Conclusion: Radiation dose at the gap between two organs with different electron density is significantly lower than calculated dose with TPS. Therefore, we must be aware of dose calculation error in TPS and great care is suggested in case of radiation treatment planning on inhomogeneous organ structure.

  • PDF

Early Bronchoconstriction After Allergen Challenge of Nonanesthetized Guinea Pigs (Ovalbumin으로 감작된 기니픽에서 Allergen 흡입으로 인한 즉시형 기관지 수축반응에 대한 비침습적 측정)

  • Kim, Je-Hyeong;Shim, Jae-Jeong;Lee, Sung-Yong;Kwon, Young-Hwan;Lee, So-Ra;Lee, Sang-Youb;Cho, Jae-Youn;In, Kwang-Ho;Yoo, Se-Hwa;Kang, Kyung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.99-106
    • /
    • 1998
  • Background: Bronchial asthma is a complex disease, which is characterized by spontaneous exacerbations of airway obstruction and persistent bronchial hyperresponsiveness. Animal models have fallen short of reproducing the human disease, particularly in mimicking the spontaneous and persistent airflow obstruction that characterized in asthma. In animals, airflow obstruction is usually assessed by measuring airflow resistance during tidal breathing under such invasive technique as tracheostomy and anesthesia. A noninvasive technique for measuring pulmonary function in small animals is needed to evaluate long-term changes in lung function during the course of experimentally produced disease without sacrificing the animal. Purpose: The purpose of this study was to evaluate early bronchoconstrcition after allergen challenge and airway responsiveness (AR) to inhaled methacholine in nonanethetized, unrestrained guinea pigs. Method: Guinea pig model of asthma was sensitized by subcutaneous injection with ovalbumin and challenged by inhalation of aerosolized ovalbumin(1% wt/vol ovlabumin). Airflow obstruction of conscious guinea pig was measured as specific airway resistance (airway resistance $\times$ thoracic gas volume). Airway resistance and thoracic gas volume of conscious guinea pig were assessed by body plethysmography before challenge and at regular intervals for as long as 30 minutes after challenge. AR to aerosolized methacholine of asthma group was compared with that of control group in body plethysmography. Result: Asthma model<> developed in 13 (65%) among 20 guinea pigs, in which early responses occurred in the airways after the exposure to inhalation with ovalbumin. Airway challenge with ovalbumin caused increase in specific airway resistance, which peaked at 6 minutes and amounted to a $231.5{\pm}30.4%$ increase from baseline. AR to aerosolized methacholine of asthma model increased significantly compared with control group. Conclusion: These results have showed a useful animal model to evaluate early bronchoconstrcition after allergen challenge and airway responsiveness in nonanethetized, unrestrained guinea pigs.

  • PDF

Evaluation of Tangential Fields Technique Using TOMO Direct Radiation Therapy after Breast Partial Mastectomy (유방 부분 절제술 후 방사선 치료 시 TOMO Direct를 이용한 접선 조사의 선량적 유용성에 관한 고찰)

  • Kim, Mi-Jung;Kim, Joo-Ho;Kim, Hun-Kyum;Cho, Kang-Chul;Chun, Byeong-Chul;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.59-66
    • /
    • 2011
  • Purpose: Investigation of the clinical use of tangential fields technique using TOMO direct in comparison to conventional LINAC based radiation therapy after breast partial mastectomy. Materials and Methods: Treatment plans were created for 3 left-sided breast cancer patients who had radiation therapy after breast partial mastectomy by using wedged tangential fields technique, field in field technique (FIF), TOMO Direct, TOMO Direct intensity modulated radiation therapy (IMRT) under the normalized prescription condition ($D_{90%}$: 50.4 Gy/28 fx within CTV). Dose volume histogram (DVH) and isodose curve were used to evaluate the dose to the clinical target volume (CTV), organ at risk (OAR). We compared and analyzed dosimetric parameters of CTV and OAR. Dosimetric parameters of CTV are $D_{99}$, $D_{95}$, Dose homogeneity index (DHI: $D_{10}/D_{90}$) and $V_{105}$, $V_{110}$. And dosimetric parameters of OAR are $V_{10}$, $V_{20}$, $V_{30}$, $V_{40}$ of the heart and $V_{10}$, $V_{20}$, $V_{30}$ of left lung. Results: Dosimetric results of CTV, the average value of $D_{99}$, $D_{95}$ were $47.7{\pm}1.1Gy$, $49.4{\pm}0.1Gy$ from wedged tangential fields technique (W) and FIF (F) were $47.1{\pm}0.6Gy$, $49.2{\pm}0.4Gy$. And it was $49.2{\pm}0.4$ vs. $48.6{\pm}0.8Gy$, $49.9{\pm}0.4$ vs. $49.5{\pm}0.3Gy$ Gy for the TOMO Direct (D) and TOMO Direct IMRT (I). The average value of dose homogeneity index was W: $1.1{\pm}0.02$, F: $1.07{\pm}0.02$, D: $1.03{\pm}0.001$, I: $1.05{\pm}0.02$. When we compared the average value of $V_{105}$, $V_{110}$ using each technique, it was the highest as $34.6{\pm}9.3%$, $7.5{\pm}7.9%$ for wedged tangential fields technique and the value dropped for FIF as $16.5{\pm}14.8%$, $2.1{\pm}3.5%$, TOMO direct IMRT as $7.5{\pm}8.3%$, $0.1{\pm}0.1%$ and the TOMO direct showed the lowest values for both as 0%. Dosimetric results of OAR was no significant difference among each technique. Conclusion: TOMO direct provides improved target dose homogeneity over wedged tangential field technique. It is no increase the amount of normal tissue volumes receiving low doses, as oppose to IMRT or Helical TOMO IMRT. Also, it simply performs treatment plan procedure than FIF. TOMO Direct is a clinical useful technique for breast cancer patients after partial mastectomy.

  • PDF

Survey of Current Status of the Patients with Home Ventilator in Seoul and Kyunggi Province (가정용 인공호흡기를 사용하는 서울 및 경기 지역 환자의 실태)

  • Ahn, Jong-Joon;Lee, Ki-Man;Shim, Tae-Sun;Lim, Chae-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.5
    • /
    • pp.624-632
    • /
    • 2000
  • Background : Home ventilation can decrease hospital-acquired infection, increase physical activity, improve nutritional status, enhance quality of life, and reduce medical costs. The number of patient using home ventilators has been increasing, particularly in Europe and United States. Although the number of patients with home ventilation has been increasing in Korea, the current status of these patients is not well known. This study was undertaken to obtain basic information upon these patients in addition to evaluating any problems related to patients' home care in our country. Methods : A register of 92 patients with home ventilators in Seoul and Kyunggi Province were obtained from commercial ventilator supply companies. The patients were contacted by phone and 29 of them accepted our visit. Information concerning education about home care before discharge, equipment cost, and problems related to home care were documented. The mode and preset variables of the home ventilator were checked; tidal volume (TV), peak airway pressure, and oxygen saturation were measured. Results : There were 26 males (90%) and their mean age was 48.0 (${\pm}20.1$) years. The underlying diseases were : 21 neuromuscular disorders, 2 spinal cord injuries, 6 chronic lung diseases. Among the caregivers, spouses (n=14) predominated. Education for home care before discharge was performed primarily by intensive care unit nurses and the education for ventilator management by commercial companies. Twenty-five of the 29 patients had tracheostomies. Volume targeted type (VTT ; n=20, 69%) was more frequently used than the pressure targeted type (PTT). Twenty-three of the 29 patients purchased a ventilator privately, which cost 7,450,000 (${\pm}$3,290,000) won for a PTT, and 14,280.000 (${\pm}$3,130,000) won for a VTT. Total cost for the equipment was 11,430,000 (${\pm}$634,000) won. The average cost required for home care per month was 1,120,000 (${\pm}$1,360, 000) won. Conclusion : The commonest underlying disease of the patients was neuromuscular disease. The VTT ventilator was primarily used with tracheostomy. Patients and their families considered the financial difficulties associated with purchasing and maintaining equipment for home care an urgent problem. Some patients were aided by a visiting nurse, however most patients were neglected and left without professional medical supervision.

  • PDF

Comparison of Virtual Wedge versus Physical Wedge Affecting on Dose Distribution of Treated Breast and Adjacent Normal Tissue for Tangential Breast Irradiation (유방암의 방사선치료에서 Virtual Wedge와 Physical Wedge사용에 따른 유방선량 및 주변조직선량의 차이)

  • Kim Yeon-Sil;Kim Sung-Whan;Yoon Sel-Chul;Lee Jung-Seok;Son Seok-Hyun;Choi Ihl-Bong
    • Radiation Oncology Journal
    • /
    • v.22 no.3
    • /
    • pp.225-233
    • /
    • 2004
  • Purpose: The Ideal breast irradiation method should provide an optimal dose distribution In the treated breast volume and a minimum scatter dose to the nearby normal tissue. Physical wedges have been used to Improve the dose distribution In the treated breast, but unfortunately Introduce an Increased scatter dose outside the treatment yield, pavllculariy to the contralateral breast. The typical physical wedge (FW) was compared with 4he virtual wedge (VW) to do)ermine the difference In the dose distribution affecting on the treated breast and the contralateral breast, lung, heart and surrounding perlpheral soft tissue. Methods and Materials: The data collected consisted of a measurement taken with solid water, a Humanoid Alderson Rando phantom and patients. The radiation doses at the ipsllateral breast and skin, contralateral breast and skin, surrounding peripheral soft tissue, and Ipsllateral lung and heart were compared using the physical wedge and virtual wedge and the radiation dose distribution and DVH of the treated breast were compared. The beam-on time of each treatment technique was also compared Furthermore, the doses at treated breast skin, contralateral breast skin and skin 1.5 cm away from 4he field margin were also measured using TLD in 7 patients of tangential breast Irradiation and compared the results with phantom measurements. Results: The virtual wedge showed a decreased peripheral dose than those of a typical physical wedge at 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, and 60$^{\circ}$. According to the TLD measurements with 15$^{\circ}$ and 30$^{\circ}$ virtual wedge, the Irradiation dose decreased by 1.35$\%$ and 2.55$\%$ In the contralateral breast and by 0.87$\%$ and 1.9$\%$ In the skin of the contralateral breast respectively. Furthermore, the Irradiation dose decreased by 2.7$\%$ and 6.0$\%$ in the Ipsllateral lung and by 0.96$\%$ and 2.5$\%$ in the heart. The VW fields had lower peripheral doses than those of the PW fields by 1.8$\%$ and 2.33$\%$. However the skin dose Increased by 2.4$\%$ and 4.58$\%$ In the Ipsliateral breast. VW fields, In general, use less monitor units than PW fields and shoriened beam-on time about half of PW. The DVH analysis showed that each delivery technique results In comparable dose distribution in treated breast. Conclusion: A modest dose reduction to the surrounding normal tissue and uniform target homogeneity were observed using the VW technique compare to the PW beam in tangential breast Irradiation The VW field is dosmetrically superlor to the PW beam and can be an efficient method for minimizing acute, late radiation morbidity and reduce 4he linear accelerator loading bV decreasing the radiation delivery time.

Evaluation of Standardized Uptake Value applying EQ PET across different PET/CT scanners and reconstruction (PET/CT 장비와 영상 재구성 차이에 따른 EQ PET을 이용한 표준섭취계수의 평가)

  • Yoon, Seok Hwan;Kim, Byung Jin;Moon, Il Sang;Lee, Hong Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • Purpose Standardized uptake value(SUV) has been widely used as a quantitative metric of uptake in PET/CT for diagnosis of malignant tumors and evaluation of tumor therapy response. However, the SUV depends on various factor including PET/CT scanner specifications and reconstruction parameter. The purpose of this study is to validate a EQ PET to evaluate SUV across different PET/CT systems. Materials and Methods First, NEMA IEC body phantom data were used to calculate the EQ filter for OSEM3D with PSF and TOF reconstruction from three different PET/CT systems in order to obtain EARL compliant recovery coefficients of each spheres. The Biograph true point 40 PET/CT images were reconstructed with a OSEM3D+PSF reconstruction, images of the Biograph mCT 40 and Biograph mCT 64 PET/CT scanners were reconstructed with a OSEM3D+PSF, OSEM3D+TOF, OSEM3D+PSF+TOF. Post reconstructions, the proprietary EQ filter was applied to the reconstruction data. Recovery coefficient can be estimated by ratio of measured to true activity concentration for spheres of different volume and coefficient variability(CV) value of RC for each sphere was compared. For clinical study, we compared SUVmax applying different reconstruction algorithms in FDG PET images of 61 patients with lung cancer using Biograph mCT 40 PET/CT scanner. Results For the phantom studied, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.05, 0.04, 0.04 and 0.03 respectively for RC. Application of the proprietary EQ filter, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.04, 0.03, 0.03 and 0.02 respectively for RC. Clinical study, there were no statistical significance of the difference applying EQ PET on SUVmax of 61 patients FDG PET image. (p=1.000) Conclusion This study indicates that CV values of RC in phantom were decreased after applying EQ PET for different PET/CT system and The EQ PET reduced reconstruction dependent variation in SUVs for 61 lung cancer patients, Therefore, EQ PET will be expected to provide accurate quantification when the patient is scanned on different PET/CT system.

Validation of the Korean Version of the St. George's Respiratory Questionnaire for Patients with Chronic Respiratory Disease (한국어판 세인트조지 호흡기설문의 타당도와 신뢰도 검정)

  • Kim, Young Sam;Byun, Min Kwang;Jung, Wou Young;Jeong, Jae Hee;Choi, Sang Bong;Kang, Shin Myung;Moon, Ji Ae;Han, Jung Suk;Nam, Chung-Mo;Park, Moo Suk;Kim, Se Kyu;Chang, Joon;Ahn, Chul Min;Kim, Sung Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.2
    • /
    • pp.121-128
    • /
    • 2006
  • Background: The "health-related quality of life" (HRQL) for patients with chronic respiratory disease has been emphasized, because chronic respiratory disease (CRD) is chronic and progressive, and it finally causes disability. HRQL instruments may be useful for monitoring patients' progress or for determining the most appropriate choice of treatment. We describe the adapting St George's Respiratory Questionnaire (SGRQ), which is a self-administered questionnaire developed by Jones et al. (1991), into the Korean version for covering three domains of health for the patients suffering with airways disease. Method: We obtained the original SGRQ from the author after gaining permission. For adaptation, we created an expert panel and translated the original questionnaire into Korean language. The translated questionnaire was then back-translated by bilingual experts and we compared it with the original questionnaire. After correction and feasibility testing, 74 patients with chronic respiratory disease (COPD, asthma, destroyed lung) completed the Korean version of the SGRQ. The clinical status of each patients was evaluated concurrently with measurement of their health status. Result: The Korean version of the SGRQ was acceptable and easy to understand. Cronbach's alpha reliability coefficient was 0.92 for the overall scale and 0.63 for the "Symptoms", subscale, 0.87 for the "Activity", subscale, and 0.89 for the "Impacts" subscales. The correlation coefficients between the overall score and the Borg scale score, oxygen saturation, and forced expiratory volume in one second ($FEV_1$) were 0.52, -0.32 and -0.26, respectively. These results support that the Korean SGRQ was correlated with other measurements. Conclusion: The Korean SGRQ was reliable and valid for patients with chronic respiratory disease, such as COPD, asthma, and destroyed lung. The SGRQ score was well correlated with other respiratory measurements as well. Although further studies should complete the adaptation work, our results suggest that the SGRQ may be used in Korea and also for international studies involving Korean CRD patients.

Desalination of Boiled Oyster Extract by Electrodialysis (전기투석에 의한 굴자숙액의 탈염 특성)

  • 박표잠;이상훈;김세권
    • KSBB Journal
    • /
    • v.15 no.2
    • /
    • pp.167-173
    • /
    • 2000
  • For selective elimination of salt from boiled oyster extract (BOE), electrodialyzer was used and the desalination conditions of B BOE were investigated. The ion-exchange membrane with a molecular weight cut off 100 Da was used for desalting of B BOE. The desalination efficiency at pH 4.0 was 13% higher than that at pH 9.0 when BOE was desalted for 90min. The e electrodialysis pro$\infty$ss could remove above 90% of the initial salt content when 5% BOE was desalted at pH 5.62 for 1 100min. The initial volume and concentration of permeation solution did not have significant effects on desalination time and r ratio. The important factors for the desalination of BOE were found to be pH and concentration of BOE. The results obtained prove that electrodialysis is a practical solution to the problem of selective elimination of salt from BOE.

  • PDF

Correction Method on Mismatched Posterior Edge of Medial and Lateral Tangential Fields for Three Fields Techniques in Breast Cancer (유방암 환자의 삼문 조사 시 내외측 접면 조사야의 Posterior Edge의 어긋남의 교정)

  • Kim Hun-Jung;Loh John JK;Kim Woo-Cheol;Park Sung-Young
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.174-181
    • /
    • 2003
  • Purpose: The target volume for the three field technique in breast cancer include the breast tangential and supraclavicular areas. The techniques rotating the gantry and couch angles, to match these two areas, will geometrically produce mismatching of the posterior edge between the medial and lateral tangential beams. This mismatch was confirmed by film dosimetry and three-dimensional computer planning. The correction methods of this mismatching were studied in this article. Materials and Methods: After the supraclavicular field was simulated using a half beam block and the medial and lateral tangential fields, by the rotation of the couch and gantry, we compared the following two methods to correct the mismatch. The first method was the rotation of coillmator until a line drawn on the posterior edge of tangential beams before the rotation of couch aligned the line drawn on the posterior edge after the rotation. The second method was the rotation of collimator according to the formula developed by the author as follows; Co=$2sin^{-1}${$sin\{theta}\{cdot}sin(C/2)$} (Co: collimator angle, $\theta$: angle between tangential beam and table, C: couch angle) Results: The film dosimetry showed the mismatching of posterior edges of the medial and lateral tangential fields prior to the rotation of collimator, while the posterior edges matched well after the rotation of collimator according to the formula. The three-dimensional computer plan also showed that the posterior edges matched well after the rotation of collimator accordingly. The DVH of the ipsilateral lung with the proper rotation of collimator angle was better than that without the rotation of collimator angle. Conclusion: The mismatching of the posterior edges of the medial and lateral tangential fields can be recognized on the three fileld technique in breast irradiation when the gantry and couch are simultaneously rotated and can be corrected with the proper rotation of the collimator angle. The radiation dose to the ipsilateral lung could be lowered with this technique.

The Correlation between HRCT Emphysema Score and Exercise Pulmonary Testing Parameters (HRCT Emphysema Scoring과 운동부하 폐기능검사 지표들 간의 상관관계)

  • Choi, Eun-Kyoung;Choi, Young-Hee;Kim, Doh-Hyung;Kim, Yong-Ho;Yoon, Se-Young;Park, Jae-Seuk;Kim, Keun-Youl;Lee, Kye-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.4
    • /
    • pp.415-425
    • /
    • 2001
  • Background : The correlation between the high resolution computed tomography(HRCT) emphysema score and the physiologic parameters including resting and exercise pulmonary function test was investigated in 14 patients($60.6{\pm}10.3$ years) with pulmonary emphysema. Methods : The patients underwent a HRCT, a resting pulmonary function test, and incremental exercise testing(cycle ergometer, 10 W/min). Computed tomography scans were obtained on a GE highlight at 10 mm intervals using 10 mm collimation, from the apex to the base after a full inspiration. The emphysema scores were determined by a CT program 'Density mask' outlining the areas with attenuation values less than -900 HU, indicating the emphysema areas, and providing an overall percentage of lung involvement by emphysema. Results : Among the resting PFT parameters, only the diffusing capacity(r=-0.75) and $PaO_2$ (r=-0.66) correlated with the emphysema score(p<0.05). Among the exercise test parameters, the emphysema score correlated significantly with the maximum power(r=-0.74), maximum oxygen consumption(r=-0.68), anaerobic threshold(V-slope method: r=-0.69), maximal $O_2$-pulse(r=-0.73), and the physiologic dead space ratio at the maximum workload(r=-0.80)(p<0.01). Conclusion: We could find that exercise testing parameters showed a much better correlation with the HRCT emphysema score, which is known to have a good correlation with the pathologic severity than the resting PIT parameters. Therefore it is suggested that exercise testing is superior to resting PIT for estimating in the estimation of the physiologic disturbance in emphysema patients.

  • PDF