• Title/Summary/Keyword: luminance distribution

Search Result 134, Processing Time 0.021 seconds

Study on Analysis of Characteristics of Illuminance and Luminance Distribution of LED Luminaires (LED 조명기구의 조도.휘도분포 특성 분석에 관한 연구)

  • Lee, Jin-Sook;Kim, Won-Do;Kim, Byoung-Soo;Han, Won-Tak
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.1-7
    • /
    • 2008
  • This study is intended to compare physical properties of fluorescent luminaires with ones of LED luminaires so as to analyze fundamental characteristics of LED luminaires. For this, a comparative analysis of uniformity ratio of illuminance and luminance distribution of these two luminaires was made, and materials for applying LED luminaires to interior construction space were prepared. This study was carried out in four stages. First, a theoretical review on LED illumination light source was made compared with the existing luminaires. Second, a mock-up to control experimental variables to meet the objective of this study was manufactured. Third uniformity ratio of illuminance and luminance distribution of each luminaire were measured by using the mock-up. Fourth, a comparative analysis of uniformity ratio of illuminance and characteristics of luminance distribution of the existing fluorescent luminaires and LED ones was made. As a result of the study, the uniformity ratio of illuminance of LED luminaires, 0.559, was higher than one of the existing fluorescent luminaires, 0.522. Namely, it was shown that illuminance distribution of LED luminaires was uniform and global diffuse was good. As a result of measuring luminance distribution, it was found that luminance distribution of LED luminaires was more uniform than one of the existing fluorescent luminaires. The maximum luminance of fluorescent luminaires and LED luminaires over the wall was $180.6[cd/m^2]$ and $155.26[cd/m^2]$ respectively. Namely, the maximum luminance of fluorescent luminaires was higher than one of LED luminaires. The average luminance of fluorescent luminaires and LED luminaires was $44.32[cd/m^2]$ and $58.65[cd/m^2]$. Like this, the average luminance of LED luminaires was higher than one of fluorescent luminaires. Considering these results, it's thought that LED luminaires can give a person in the room a more comfortable working environment than fluorescent luminaires.

Design of an Ultrasmall Flexible-endoscope Illumination Optical System with Bat-wing Light Distribution

  • Ju-Yeop Yim;Chul-Woo Park;Mee-Suk Jung
    • Current Optics and Photonics
    • /
    • v.7 no.6
    • /
    • pp.755-760
    • /
    • 2023
  • In this paper, an illumination optical system that can mitigate the saturation phenomenon in the center of an image (caused by the typical flexible-endoscope illumination system using LEDs with Lambertian light distribution) is designed. When an LED with Lambertian light distribution is used as a light source, the amount of light in the center of the endoscopic illumination system is relatively high, compared to the periphery, causing saturation in the image. Since this phenomenon causes difficulty in detecting the patient's lesion, it is necessary to find a lighting-system design that can alleviate the saturation phenomenon. Therefore, in this paper a lighting system with bat-wing light distribution, which can lower the intensity at the center and secure the maximum amount of light at the maximum light distribution angle, is designed. In addition, to check the performance of the designed lighting system, a simulation of illumination and luminance is conducted for a system using a common aspherical lens with otherwise the same components. As a result, it is confirmed that the lighting system designed in this paper effectively reduces the luminance value at the center and secures more luminance values at the periphery than the familiar lighting system.

A Study on luminance Measurement Method of Lightscape using DSLR (DSLR를 이용한 야간경관 휘도 측정 기법에 관한 연구)

  • Lee, Wan-Soo;Chung, Kang-Wha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.10-17
    • /
    • 2009
  • A lightscape is displayed by lots of luminance containing the wide range of lighting. The measurement of the luminance is limited because the brightness distribution was measured from a point in the existing methods. We used DSLR cameras to get information of the luminance efficiently and conveniently. The application of DSLR camera which easily provides images is widely used nowadays. We suggested the analysis of the luminance and measurement method of the scene from DSLR images using luminance distribution measurement technique.

Analysis of Luminance distribution of Illuminated Bridges by View (조망의 변화에 따른 교량경관조명의 휘도특성분석)

  • Choi, Yoon-Seok;Jeong, In-Young;Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.1-8
    • /
    • 2006
  • The study is to analyze the surface luminance of the illuminated bridges according to the change of view point using luminance measurements with instrument CS-100 and ProMetric 1400. For the purpose the illuminated bridges of the structure type were sleceted. Also, the view points were classified the three types which are a perspective view, a building view, a driver view. The luminance of the surrounding sky, surface of river, upper structure or bridge, girder side, and pier or the objects was measured. As a result of this study, The Kwangjin and Dongho Bridge showed the luminance distribution of a perspective view was high. And the Olympic and Dongjac bridge the luminance distribution of building view was high. The luminance effect of the girder bridge that has no upper structure was distinguished for the perspective view, and the cable-stayed girder bridge and the arch bridge were characterized as the building view.

Development and Validation of Sky Simulator for Reproducing CIE Overcast Sky Model (돔형 인공천공의 개발 및 CIE표준담천공 구현 검증에 관한 연구)

  • Shin, Ju Young;Yun, Geun Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.97-103
    • /
    • 2010
  • Sky simulator is a effective daylighting design tool that can evaluate three dimensional performance of lighting. Especially, the dome type sky simulator offer reliable and reproducible daylighting performance with different standard sky models. Recently, K university has developed the dome type sky simulator(sky dome) with the diameter of 6.5m and the height of 3.7m. The sky dome consists of a group of 145 large steel panels with 72 halogen lamps which are arranged in a circular array. The luminance distribution of the sky dome can be calibrated by changing the angle and the brightness of the lamps respectively. To allow more reliable prediction and evaluation of daylighting through the sky dome, It is essential to validate the sky luminance distribution of the sky dome. This study consider the validation of the comparisons between the measured and the calculated luminance values for the CIE standard overcast sky. Also, the error rate between the measured and the calculated luminance values were compared to the previous studies. The results indicated that the K university sky dome can reproduce reliable CIE standard overcast sky with the average relative error rate of 4.4% and root-mean-square error(RMSE) of 5.4%.

Luminance Performance of a Room with Light Guide and Blind Systems by Mockup Experiments (혼합형 채광조절장치가 실내공간의 휘도분포에 미치는 영향에 관한 Mockup 실험평가)

  • Shin, Hwa Young;Ahn, Hyun Tae;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.65-72
    • /
    • 2007
  • As ecological design elements, daylighting can be applied to provide adequate illumination on visual tasks to create an attractive visual environment and to save electrical energy. Daylighting control systems reject direct sunlight and penetrate it onto the ceiling or to deep into the room. This study aims to evaluate the luminance environment of sloped light guide with automated venetian blind systems according to sun angle changes. For evaluation, a mock-up model was used and the south facing side-window mounted between the clerestory window and the view window. To assess luminance performance, 3 view points of luminance were monitored. As results, the conventional and lightshelves show ideal luminance ratio between workplane and surroundings(3:1) and workplane and darkness area(2:1) due to total ratio of surroundings and darkness area has lower ratio than workplane. Compared to the lightshelves window, conventional window shows unrelieved effect in between the workplane and brightness area(1:5). It means that there has low deviation according to the required standards. Also, compared to the ratio between the brightness area and darkness area(2~6:1) conventional window with high deviation(10~20:1) provide discomfort glare due to the excessively strong contrast, while lightshelves window shows a required luminance ratio that provide a three-dimensional effect to occupants. Therefore, luminance distribution indicate that application of a lightshelves and blinds not only has a significantly positive effect but also offers higher luminance quality in a daylit room

Luminance Analysis of the Apartment Exterior Lighting using HDR Images (HDR이미지를 이용한 공동주택 외부조명의 휘도 분석)

  • Hong, Sung-De;Shin, Eun-Ju
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.12 no.2
    • /
    • pp.33-38
    • /
    • 2012
  • The purpose of luminance measurement in lighting design of urban scale is to prevent light trespass and light pollution, caused by over-bright. Specially, the illumination of road, tunnel and sports complex as urban infrastructure is measured by international standard for illuminance and luminance. It has been used the spot luminance meter and the image photometer to define the characteristics of qualitative and quantitative in exterior lighting. This study introduced the concept of HDR Image, procedure of HDR Image creation and analysis. Applications of HDR Image, particularly within the apartment building exterior lighting design analysis, have been demonstrated. The procedure proposed in this study is a affordable method that is useful for the assessment of luminance distribution in the scene with electric light. It also provides a measurement capability with the high resolution luminance data within a large field of view efficiently and quickly, which is not possible to achieve with a luminance meter.

Relationship between Adaptation Luminance and Threshold Zone Luminance for Vehicular Traffic Tunnels (터널 순응휘도와 경계부 휘도의 관계 연구)

  • Cho, Won Bum;Jeong, Jun Hwa
    • International Journal of Highway Engineering
    • /
    • v.16 no.3
    • /
    • pp.85-99
    • /
    • 2014
  • PURPOSES : This study has been performed with the objective to determine threshold zone luminance of adaptation luminance by target safety level in a vehicular traffic tunnel with design speed set at 100km/h. METHODS : The study made a miniature capable of portraying changes in luminance distribution within $2{\times}10^{\circ}$ conical field of view of the driver approaching to the tunnel for the test. Test conditions were set based on justifications for CIE 88-1990's threshold zone luminance used as a reference by domestic tunnel light standards (KS C 3703 : 2010). Luminance contrast of object background and object is 23%, object presentation duration is 0.5 seconds, and size of the object background is $7.3{\times}11.5m^2$ RESULTS : Threshold zone luminance was set within adaptation luminance of $100{\sim}3,000cd/m^2$. Adaptation luminance and threshold zone luminance based on 50%, 75% and 90% target safety level all showed a relatively high linear relationship. According to findings in the study, it is not appropriate to specify the relationship between adaptation luminance and threshold zone luminance as luminance ratio. Rather, direct utilization of the linear relationship gained from the study findings appears to be the better solution. CONCLUSIONS : Findings of this study may be used to determine operation of threshold zone luminance based on target safety level. However, a proper verification and validity of test results are required. Furthermore, a study to determine proper threshold zone luminance level considering target safety level reviewed in this study and various decision-making factors such as economic conditions in Korea and energy-related policies should be carried out in addition. Additional tests on adaptation luminance greater than $3,000cd/m^2$ will be performed, through which application scope of the test findings will be broadened.

Evaluating Interior Glare Base on Shading Adjustments (창호의 차양 조절에 따른 실내 글레어 평가)

  • Lim, Sang-Hoon
    • Journal of Korean Living Environment System
    • /
    • v.20 no.2
    • /
    • pp.233-237
    • /
    • 2013
  • Daylighting affects the luminous environment and provides comfortable environment to the occupants. However, excessive daylighting might have negative influences on the visual comfort. Skylight, light intensity and distribution, and insolation could cause glare effects on the occupants. This study analyzed the effect of fenestration on the interior glare effects, and verified luminous environment adjustability through mock up test of conventional fenestration and 'Convergence Window System' by analyzation of luminance, luminance contrast, and glare effect. Consequently, room installed Convergence Window System was improved luminance contrast and PGSV Level.

A Study on the Ratio of Luminance and Energy Saving for Lighting of Schoolroom (학교 강의실 조명에 대한 에너지 절약과 균제도에 관한 연구)

  • 최홍규;최병숙;조경남;조계술;김정한;김성수;조의상;정성윤
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.135-143
    • /
    • 2000
  • This parer is the among educational environment, lighting's role is more important since it improves the visual tasks, capability of work, and it help to build both balanced mind and body. Also, since students need spend most of their time inside rather than outside, students need appropriate illuminance everyday. If optimum illuminance and distribution of luminance is properties controlled, people can decrease the fatigue of eyes, and also, people can maximize their efficiency of work. This present studying class chose of two school measured illuminance using the computer simulation improved ratio of luminance and luminance by distribution of lighting improve the economy and energy saving.

  • PDF