Characteristics of Pressure Drop in SMX Type Motionless Mixers (SMX형 정적 믹서의 압력손실 특성)

  • Yang, Hei-Cheon;Park, Jeong-Il
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.6
    • /
    • pp.479-486
    • /
    • 2008
  • The objective of this study is to investigate experimentally the characteristics of pressure drop in SMX type motionless mixers. The motionless mixers used are SMX-O, SMX-H, SMXL-O and SMXL-H ones. The SMX-H and SMXL-H mixer elements have been designed to reduce the pressure drop as compared with the SMX-O and SMXL-O ones. The Reynolds number based on the bulk average properties of the water is in a range of 5000 to 13000. The pressure drops across the motionless mixers are measured and the friction factors are calculated using the pressure drop data. On the average, the friction factors of the SMX-H and SMXL-H mixers are about 8% and 15% lower than those of the SMX-O and SMXL-O ones. In addition, the proposed correlations from the experimental data for the friction factor are presented and compared with those obtained from the literature.

Development on Full Drop Type Aluminium Form System (완전 드롭형 알폼 시스템 개발)

  • Lim, Nam-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.14-15
    • /
    • 2021
  • Even though the Al. form system, which was developed to replace the Euro-form, has been used as the slab lower formwork for almost all concrete structures based on the light weight and high conversion rate, the low-noise Drop method has been developed and used in order to overcome the limitations of the Al. Form system such as noise pollution and safety accidents caused by free fall during the demolding. However, as the low-noise drop method is still insufficient, Safety Full Drop Al. Form method is expected to be in the spotlight in the construction market based on its excellent advantages compared to the developed methods. In addition, we plan to conduct research to further contribute to securing the quality of the overall structure through continuous improvement and supplementation by introducing an automation system to the very construction method.

  • PDF

Greenhouse Cooling by Fog System (FOG SYSTEM 을 이용한 여름철 온실냉방)

  • 서원명
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.1
    • /
    • pp.60-71
    • /
    • 1999
  • This study was performed to improve underirable warm greenhouse environment by fog cooling system in summer season. The resultsof droplet size analysis and cooling effects for fog cooling system are summarized as follows ; 1. At the pump pressure of 70kgf/$\textrm{cm}^2$ , the mean (SMD) drop size was 22.6${\mu}{\textrm}{m}$ and the maximum and minimum drop size was 45.68${\mu}{\textrm}{m}$ and 1.73${\mu}{\textrm}{m}$ , respectively, and almost all of the drop size was less than 40${\mu}{\textrm}{m}$. 2. The temperature of fog cooling greenhouse with 60% shading was dropped more than 2$^{\circ}C$ below the ambient temperature , while the greenhouse temperature without shading was 1$^{\circ}C$ higher than the ambient temperature. 3. It was found that fog spraying intervals were significantly influential on cooling effect. 4. When the greenhouse was ventilated sufficiently by natural vent system, green house temperature could be maintained by 2.5$^{\circ}C$ lower than the ambient temperature, while it was difficult to drop the greenhouse temperature below ambient temeperature without sufficient ventilation. 5. It was found that the temperature of experimental greenhouse could be maintained 3$^{\circ}C$ to 14$^{\circ}C$ lower that of control greenhouse though there were variations depending on experimental and weather conditions.

  • PDF

Experimental Study on Heat Transfer and Pressure Drop of Heat Exchangers for Cooling Fan Coil Unit (냉방용 팬코일 유닛 열교환기의 열전달 및 압력강하 특성 실험연구)

  • Kwon, Young-Chul;Ko, Kuk-Won;Kwon, Jeong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.599-604
    • /
    • 2008
  • An experimental study has been performed to investigate the air-side capacity and pressure drop of the fin-tube heat exchanger for a fan coil unit under a cooling condition. The experimental data of five kinds of slit fin-tube heat exchangers were measured using an air-enthalpy calorimeter and a constant temperature water bath. Cooling capacities at the air and water rating flow rates were larger at the lower inlet water temperature. With increasing the water flow rate, the cooling capacity increased at the constant rate. Under the lower inlet water temperature, since the condensate was generated more on the fin-tube surface, the air-side pressure drop of the heat exchanger was larger.

Effects of Kinematics and Kinetics of the Lower Extremities Joint during Drop Landing in Adult Women with Patellofemoral Pain Syndrome (슬개대퇴동통증후가 성인 여성의 드롭랜딩 시 하지 주요관절의 운동역학적 변화에 미치는 영향)

  • Jeon, Kyoungkyu;Yeom, Seunghyeok
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.1
    • /
    • pp.64-71
    • /
    • 2021
  • Objective: This study investigated the different in isokinetic peak strength of the knee joint, and kinetics and kinematics in drop landing pattern of lower limb between the patellofemoral pain syndrome (PFPS) patients and normal. Method: 30 adult females were divided into the PFPS (age: 23.13±2.77 yrs; height: 160.97±3.79 cm, weight: 51.19±4.86 kg) and normal group (age: 22.80±2.54 yrs, height: 164.40±5.77 cm, weight: 56.14±8.16 kg), with 15 subjects in each group. To examine the knee isokinetic peak strength, kinematics and kinetics in peak vertical ground reaction force during drop landing. Results: The knee peak torque (Nm) and relative strength (%) were significantly weaker PFPS group than normal group. In addition, PFPS group had significantly greater hip flexion angle (°) than normal group. Moreover, normal group had significantly greater moment of hip abduction, hip internal rotation, and left ankle eversion than PFPS group, and PFPS group had significantly greater moment of knee internal rotation. Finally, there was significant differences between the groups at anteroposterior center of pressure. Conclusion: The PFPS patients had weakened knee strength, and which can result in an unstable landing pattern and cause of more stress in the knee joints despite to effort of reduce vertical ground reaction force.

Evaluation of Changesin the Physical Characteristics of Raindrops Under a Canopy in Central Korea (나무 아래 빗방울(雨滴)의 물리적 특성변화 분석)

  • Kim, Jin Kwan;Kim, Min Seok;Yang, Dong Yoon;Lim, Young Shin
    • Journal of The Geomorphological Association of Korea
    • /
    • v.23 no.3
    • /
    • pp.105-122
    • /
    • 2016
  • To evaluate the changes in the physical characteristics of open rainfall related to canopy effects and rainfall intensity in Korea, the terminal velocity of raindrops and drop size distributions(DSD) were continuously measured by an optical-laser disdrometer in an open site(Op) and in two forest stands(Th1: Larix leptolepis, Th2: Pinus koraiensis) during five rainfall events in 2008. The terminal velocity, DSD and two forms of kinetic energy(KE, $Jm^{-2}$ $mm^{-1}$; KER, $Jm^{-2}$ $h^{-1}$) of open rainfall drops were determined and were compared with those of throughfall drops under two different canopy heights. The effects of the canopy and rainfall intensity, together with wind speed, on the changes in drop size and kinetic energy of throughfall were evaluated. Throughfall drops were larger than open rainfall drops. The distribution of terminal velocities for the drop sizes measured at Th2 was lower than that at Op; however, at Th1 the distribution was similar to that at Op. The total kinetic energy of throughfall at Th1 and Th2 was higher than the total kinetic energy of open rainfall, and the kinetic energy distribution for the drop sizes wassimilar to the drop size distribution. The observed throughfall-KER at Th1 was lower than an estimate previously produced using a model. The overestimation from the modeled value at Th1 was likely to be due to overestimated values of a square root transformation of fall height and its coefficient in the model because the distributions of terminal velocity for the drop size measured at Th1 were similar to those of open rainfall.

Vertical Stiffness and Lower Limb Kinematic Characteristics of Children with Down Syndrome during Drop Landing (드롭랜딩 동작 시 다운증후군 아동들의 수직 강성과 하지 운동학적 특성)

  • Koo, Dohoon;Maeng, Hyokju;Yang, Jonghyun
    • Korean Journal of Applied Biomechanics
    • /
    • v.29 no.3
    • /
    • pp.137-143
    • /
    • 2019
  • Objective: Ligament laxity and hypotonia are characteristics of Down syndrome patients. The aim of this study was to compare the landing pattern between Down syndrome patients and typically developing subjects. To compare the landing pattern, variables related to ligament laxity and hypotonia i.e. vertical stiffness and lower extremities kinematics were investigated. Method: Five subjects with Down syndrome (age: $14.6{\pm}1.8years$, mass: $47.6{\pm}6.94kg$, height: $147.9{\pm}6.0cm$) and six able-bodied subjects (age: $13.2{\pm}0.4years$, mass: $54.7{\pm}6.7kg$, height: $160.1{\pm}9.8cm$) participated in this study. Results: The vertical displacement of the center of mass, vertical reaction force, leg stiffness and range of ankle angle range among Down syndrome patients were significantly different than typically developing group. The youth with Down's syndrome appeared to receive greater vertical impact force at landing than normal youth. Conclusion: The differences in the biomechanical characteristics suggest the delay in motor development among Down syndrome patients and an increased risk of injury to the lower extremity during movement execution such as drop landing.

Effects of Navicular Drop on Lumbar Disc Herniation (주상골 하강이 요추 추간판 탈출증에 미치는 영향)

  • Hwang, Gwon-Pil;Jung, Min-Keun;Park, Hyun-Sik
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.19 no.2
    • /
    • pp.19-22
    • /
    • 2013
  • Background: Excessive pronation of the feet can cause excessive inner rotation of the femur, followed by increased stress in the gluteus maximum, increased front slope of the pelvis, and lumbar lordosis, which leads to lumbar pain. The aim of the present study was to use the navicular drop test to examine foot pronation that can cause lumbar lordosis and to determine whether the navicular drop is lower in patients diagnosed with lumbar disc than in patients without this diagnosis. Methods: The Navicular Drop score was set by subtracting the navicular height at a standing position from the navicular height in a sitting position. The Navicular Drop measurements for college student with and without Lumbar Herniated Intervertebral Disc were compared using an independent t-test. Results: The control group were measured right $7.44{\pm}2.96$ and left $8.04{\pm}3.23$. The experimental group were measured right $2.12{\pm}1.33$ and left $2.80{\pm}1.29$. Therefore significant difference was found between the two groups (p<0.05). Conclusions: The navicular drop affected lumbar herniated intervertebral disc.

  • PDF

판각형 열교환기 내의 R-22 증발 압력강하 특성에 관한 실험적 연구

  • 서무교;박재홍;김영수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.930-938
    • /
    • 2001
  • In this study, evaporation pressure drop experiments were conducted with two types of plate and shell heat exchangers (P&SHE) using R-22. An experimental refrigerant loop has been established to measure the evaporation pressure drop of R-22 in a vertical P&SHE. The flow channels were formed by adding three plates having a corrugated channel of a chevron angle of $45^{\circ}$. The R-22 flows down in one channel exchanging heat with the hot water flowing up in the other channel. The effect of the refrigerant mass flux, average heat flux, system pressure and vapor quality were explored in detail. During the experiment, the quality change between the inlet and outlet of the refrigerant channel ranges from 0.03 to 0.15. The present data showed that two types of P&SHE have similar trends. The pressure drop increases with the vapor quality for both types of P&SHE. At a higher mass flux, the pressure drop is higher for the entire range of the vapor quality. Also, the increase in the average heat flux increases the pressure drop. Finally, at a higher system pressure, the pressure drop is found to be slightly lower.

  • PDF

A Study on Filtration Performance Test with Electrostatically Enhanced Fabric Filter (정전형여과집진방식에서 여과특성에 관한 연구)

  • 천중국;박출재;최금찬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.4
    • /
    • pp.361-367
    • /
    • 1995
  • This study has been carried out to investigate the filteration performance of Electrostatically Stimulated Fabric Filter(ESFF) at high temperature condition. The electric field was maintained parallel to the fabric surface. The benefits of ESFF are lower residual pressure drop, improvement of fine particle removal efficiency and increasing reduced rate of pressure drop during a filteration cycle, stable operation at higher filtering velocities. According to the variance of filtering velocities and dust loadings, the results are summarized as follows; By imposing an electric field on the filter, the reduced rate of pressure drop was 7.sim.18% at room temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Under the electric field around the filter, the reduced rate of pressure drop was 10.sim.35% at high temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Most of all, at high temperature, the value of reduced rate of pressure drop was resulted to 25%. Also the collecting efficiency was shown clearly improved. By the SEM photo analysis, the number of penetrated particles at the Conventional Fabric Filter was approximately two times that of Electrostatically Stimulated Fabric Filter.