• Title/Summary/Keyword: lower amplitude

Search Result 483, Processing Time 0.027 seconds

CORRELATIONS BETWEEN ORBICULARIS ORIS AND MENTALIS MUSCLE ACTIVITY AND CRANIOFACIAL MORPHOLOGY IN NORMAL OCCLUSION AND CLASS III MALOCCLUSION (정상교합자와 3급 부정교합자에서 구륜근과 턱끝근의 활성과 안면골격 사이의 상관성에 관한 연구)

  • Chang, Chun Sil;Lee, Ki Soo
    • The korean journal of orthodontics
    • /
    • v.22 no.1
    • /
    • pp.253-271
    • /
    • 1992
  • The purpose of this study was to investigate the difference of EMG activity of the Orbicularis oris and Mentalis muscle between normal occlusion and class III malocclusion group during various lip position and to find out whether any correlations exist between the muscular activity and craniofacial morphology. In this study, 50 subjects with a mean age of 22.9 Years (range 20.0-26.0) were investigated (25 subjects were normal occlusion, and 25 subjects were class III malocclusion). EMG data were recorded from the Orbicularis oris and Mentalis muscle during rest lip posture, lip position at maximum biting, lip position at maximum sealing effort, lip position at chewing, swallowing and phonation with the Medelec MS-25 electromyographic machine. Lateral cephalometric radiographs was taken with the mandible in intercuspal position on all subjects. All data were recorded and statistically processed. The findings of this study can be summerized as follows: 1. In normal occlusion, the maximal mean amplitude of upper lip during the lip position at chewing was lower than that of lower lip and mentalis muscle. But the maximal mean amplitude of orbicularis oris and mentalis muscle during the other lip position was not statistically different. 2. In Class III malocclusion, the maximal mean amplitude of upper lip during the lip position at chewing, swallowing and phonation was lower than that of lower lip and mentalis muscle. But the maximal mean amplitude of orbicularis oris and mentalis muscle during the other lip position was not statistically different. 3. Compare to normal occlusion, the Class III malocclusion was showed low maximal mean amplitude of upper lip during rest lip posture and the lip position at swallowing of saliva, and showed great maximal mean amplitude of lower lip and meantalis muscle during the lip position at chewing and phonation. 4. In normal occlusion, the maximal mean amplitude of upper lip during various lip position was not correlated with the length and thickness of upper lip, but the maximal mean amplitude of lower lip during the lip position at chewing and swallowing was positively correlated with the thickness of lower lip. 5. In Class III malocclusion, the maximal mean amplitude of upper lip during rest lip posture was negatively correlated with the thickness of upper lip, and the maximal mean amplitude of lower lip and mentalis muscle during the lip position at chewing and swallowing was positively correlated with the thickness of lower lip and mentalis muscle. But the maximal mean amplitude of orbicularis oris and mentalis muscle during the other lip position was not correlated with the cephalometric measurements of soft tissue. 6. The correlation between the maximal mean amplitude of orbicularis oris and mentalis muscle and cephalometric measurements of incisors was not nearly present. 7. In normal occlusion, the maximal mean amplitude of lower lip and mentalis muscle during the lip position at maximum biting was negatively correlated with the angle between palatal plane and mandibular plane. In Class III malocclusion, the maximal mean amplitude of upper lip, lower lip and mentalis muscle during function was negatively correlated with the length of maxilla, the maximal mean amplitude of upper lip and lower lip during function was negatively correlated with the SNA and SNPo, and the maximal mean amplitude of lower lip during the lip position at chewing was negatively correlated with the ANB.

  • PDF

Analysis of Amplitude Distortion in Super Wide-Band AM Signal Transmission (초광대역 AM 신호전송에서의 진폭왜율해석)

  • 이충웅
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.8 no.3
    • /
    • pp.27-32
    • /
    • 1971
  • This paper presents the analysis of the amplitude distortion occurring in the transmission of super wideband AM signal when the amplitude and phase variations of the upper and lower sidebands of the AM signal are symmetrical, and odd symmetrical with respect to the carrier. It is shown that the case where the amplitude variations of the upper and lower sidebands of AM signal are symmetrical with respect to the carrier while the phase variations of the upper and lower sidebands are odd symmetrical with respect to the carrier induce, no amplitude distortion in AM signal transmission.

  • PDF

Comparison Between Performance of a Sound-Triggered Measurement and an Amplitude-Triggered Measurement in Shaking Table Tests (진동대를 이용한 모바일 진동 계측 기기의 사운드 트리거 계측과 진폭 트리거 계측 성능 비교)

  • Mapungwana, S.T.;Lee, Jong-Ho;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.1
    • /
    • pp.117-126
    • /
    • 2019
  • Micro-Electro-Mechanical Systems (MEMS) sensors have been widely used in Structural Health Monitoring due to their convenience and lower costs in comparison to conventional sensors. Triggered measurements are relevant in events such as earthquakes because unlike continuous measurements, they only record the structural response once an event happens. This is more cost effective and it makes the data more manageable because only the required measurements from the event are recorded. The most common method of triggering is amplitude triggering. However, lower input amplitudes (less than 0.1g) cannot be triggered by using this method. In this paper, sound triggering was introduced to allow triggered measurements for lower input amplitude values. The performance of the sound triggering and amplitude triggering were compared by a series of shaking-table tests. It was seen that sound-triggering method has a wider frequency (0.5~10Hz) and amplitude (0.01~1.0g) range of measurements. In addition, the sound triggering method performs better than the amplitude triggering method at lower amplitudes. The performance of the amplitude triggering, in terms of the triggering being simultaneous improves at higher input amplitudes.

Changes in Hardness and Damping Capacity of Aged Mg-5%Sn Alloy (시효한 Mg-5%Sn 합금의 경도와 진동감쇠능 변화)

  • Jun, Joong-Hwan
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.35 no.5
    • /
    • pp.255-261
    • /
    • 2022
  • In this work, the strain-amplitude independent and strain-amplitude dependent damping capacities of Mg-5%Sn alloy have been investigated as a function of its age-hardening response. The hardness increased with an increase in aging time, reached a peak value after 48 h, and then it gradually decreased. The damping capacities of the Mg-5%Sn alloy exhibited a decreasing tendency in the order of solution-treated, under-aged, peakaged, and over-aged states in the strain-amplitude dependent region, whereas they increased continuously with aging time in the strain-amplitude independent region. The microstructural examination during aging revealed that the lower concentration of Sn solutes in the α-(Mg) matrix and the lower density of the Mg2Sn precipitate particles may well be the crucial factors for better damping values in the strain-amplitude independent and strain-amplitude dependent regions, respectively.

Difference in sEMG on lower extremity during leg press exercise with whole body vibration with various amplitude and frequency (수직 진동을 동반한 Leg Press 운동 시 진동 크기와 주파수에 따른 하지 근육의 근전도 차이 분석)

  • Choi, Jin-Seung;Kim, Yong-Jun;Kang, Dong-Won;Mun, Kyung-Ryoul;Tack, Gye-Rae
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1492-1495
    • /
    • 2008
  • As a prerequisite of developing muscle biofeedback system which can simulate analogous isokinetic exercise, the purpose of this study was to study the effects of frequency and amplitude of whole-body vibration on the difference in sEMG on lower extremities during leg press exercise with/without vibration. The amplitude of vibration was set to 20, 50, 80 and the frequency of vibration was set to 10, 20, 30, and 50 Hz. EMG were measured at Vastus lateralis muscle and Vastus medialis muscle. MP100 EMG module(BIOPAC system Inc., USA) was used for EMG measurement. The result showed that the combination of frequency of 30Hz and amplitude of 50 had more activated EMG than other combination with relatively small work load (30kg). It is necessary to experiment the frequency between 20 and 40Hz in detail, and to normalize sEMG using maximal voluntary contraction (MVC).

  • PDF

Effects of loading conditions on the fatigue failure characteristics in a polycarbonate

  • Okayasu, Mitsuhiro;Yano, Kei;Shiraishi, Tetsuro
    • Advances in materials Research
    • /
    • v.3 no.3
    • /
    • pp.163-174
    • /
    • 2014
  • In this study, fatigue properties and crack growth characteristics of a polycarbonate (PC) were examined during cyclic loading at various mean stress (${\sigma}_{amp}$) and stress amplitude (${\sigma}_{mean}$) conditions. Different S vs. N and da/dN vs. ${\Delta}K$ relations were obtained depending on the loading condition. The higher fatigue strength and the higher resistance of crack growth are seen for the PC samples cyclically loaded at the higher mean stress and lower stress amplitude due to the low crack driving force. Non-linear S - N relationship was detected in the examination of the fatigue properties with changing the mean stress. This is attributed to the different crack growth rate (longer fatigue life): the sample loaded at the high mean stress with lower stress amplitude. Even if the higher stress amplitude, the low fatigue properties are obtained for the sample loaded at the higher mean stress. This was due to the accumulated strain energy to the sample, where severe plastic deformation occurs instead of crack growth (plasticity-induced crack closure). Shear bands and discontinuous crack growth band (DGB) are observed clearly on the fracture surfaces of the sample cyclically loaded at the high stress amplitude, where the lower the ${\sigma}_{mean}$, the narrower the shear band and DGB. On the other hand, final fracture occurred instantly immediately after the short crack growth occurs in the PC sample loaded at the high mean with the low ${\sigma}_{amp}$, i.e., tear fracture, in which the shear bands and DGB are not seen clearly.

Fatigue Properties of Rail Steel Under Constant Amplitude Loading and Variable Amplitude Loading (일정 및 변동하중하의 레일강의 피로특성)

  • Kim, Cheol-Su;Kim, Jeong-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.4
    • /
    • pp.654-661
    • /
    • 2001
  • In this study, fatigue growth behavior of the transverse crack, which was the most dangerous damage among the various types of rail defects, was investigated using the notched keyhole specimen under constant amplitude loadings. Fatigue limit of smooth specimen in rail steel at R=0 was 110MPa, and the fatigue crack initiation life in the region of the low stress amplitude (ie. long life) occupied the major portion of the total fatigue life. The fatigue strength under variable amplitude loading was converted to the equivalent fatigue strength based upon. Miners rule, which was estimated approximately 9% lower than that under constant amplitude loading. Also, in the low ΔK(sub)rms region ($\leq$21MPa√m), fatigue crack growth rate (da/dN) under constant amplitude loading was higher than that under variable amplitude loading, whereas the tendency was reversed in the high ΔK(sub)rms region. It is believed that this behavior is due to the transition of fracture appearance.

Evaluation of Fracture Behavior of SA-516 Steel Welds Using Acoustic Emission Analysis

  • Na, Eui-Gyun;Ono, Kanji;Lee, Dong-Whan
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.197-204
    • /
    • 2006
  • The purpose of this study is to evaluate the AE characteristics for the basemetal, PWHT (post-weld heat treatment) and weldment specimens of SA-516 steel during fracture testing. Four-point bending and AE tests were conducted simultaneously. AE signals were emitted in the process of plastic deformation. AE signal strength and amplitude of the weldment was the strongest, followed by PWHT specimen and basemetal. More AE signals were emitted from the weldment samples because of the oxides, and discontinuous mechanical properties. AE signal strength and amplitude for the basemetal or PWHT specimen decreased remarkably compared to the weldment because of lower strength. Pre-cracked specimens emitted even lower event counts than the corresponding blunt notched specimens. Dimple fracture from void coalescence mechanism is associated with low-level AE signal strength for the basemetal or PWHT. Tearing mode and dimple formation were shown on the fracture surfaces of the weldment, but only a small fraction produced detectable AE.

The Medial Antebrachial Cutaneous Nerve : Orthodromic and Antidromic Conduction Studies (아래팔 내측분지신경의 자극하는 방법에 따른 신경전도검사의 비교)

  • Kwak, Jae Hyuk;Lee, Dong Kuck
    • Annals of Clinical Neurophysiology
    • /
    • v.7 no.2
    • /
    • pp.83-87
    • /
    • 2005
  • Background: The study of the medial antebrachial cutaneous nerve (MABCN) is an underused electrodiagnostic tool. But its use is often crucial for assessing mild lower brachial plexus or MABCN lesions, and sometimes for differentiating an ulnar mononeuropathy from a lower brachial plexopathy. This study was designed to know the difference of amplitude and velocity in a stimulation method (orthodromic vs antidromic), side of an arm and sex according by age. Method: MABCN conduction studies were performed orthodromically and antidromically in 90 subjects (42 women and 48 men, ranging from 22 to 79 years of age). We divided subjects into three groups by age (group 1: 20-39 years, group 2: 40-59 years, group 3: 60-79 years). The mean sensory nerve action potential amplitudes and sensory nerve conduction velocities in each group was compared by stimulation method, side of an arm and sex. Result: The amplitudes and velocities made a significant difference between orthodromic and antidromic method in all age groups. At comparison in amplitude and velocity by side of an arm, only amplitude was significantly higher in right arm than left by any stimulation method. The amplitudes and velocities were of no statistically differences in sex except amplitude checked orthodromically in right arm. Conclusion: This study suggests that there is the differences in conduction study of MABCN by stimulation method and side of an arm.

  • PDF

Damping Capacities of Mg-Al alloy with As-Cast and Discontinuous Precipitates Microstructures (주조 및 불연속 석출물 미세조직을 가지는 Mg-Al 합금의 진동감쇠능)

  • Jun, Joong-Hwan
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.34 no.5
    • /
    • pp.218-225
    • /
    • 2021
  • In this study, damping capacities were comparatively investigated for Mg-9%Al alloy with as-cast (AC) and fully discontinuous precipitates (DPs) microstructures, respectively. The DPs microstructure was obtained by solution treatment at 678 K for 24 h, followed by furnace cooling to RT. The AC microstructure was typically characterized by partially divorced eutectic β(Mg17Al12) phase particles distributed along the α-(Mg) matrix cell boundaries. The DPs microstructure showed lamellar morphology consisting of α and β thin layers with various interlamellar spacings. The DPs microstructure had better damping capacity than the AC microstructure in the strain-amplitude independent region, while in the strain-amplitude dependent region, the damping behavior was reversed. In view of the microstructural features of AC and DPs, the lower concentration of Al in the α-(Mg) phase for the DPs microstructure and the lower β phase number density for the AC microstructure would be responsible for the higher damping capacities in the strain-amplitude independent and strain-amplitude dependent regions, respectively.