• Title/Summary/Keyword: low-power system

Search Result 5,512, Processing Time 0.037 seconds

A study of residential solar airconditioning system using bidirectional PWM converter (양방향성 PWM컨버터를 이용한 가정용 태양광 에어컨 시스템에 관한 연구)

  • 유권종;송진수;황인호;김홍성;고재석;최규하;김한성
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.3
    • /
    • pp.358-364
    • /
    • 1996
  • Recently, much power demand from domestic power consumer is weakening the allowable power reserve margin in summer, especially at midday for one day due to a steep increase of air cooling loads such as air conditioner. Therefore solar airconditioning system can'be considered as one of the best remedies to meet the increase of peak power. Generally in solar air conditioning system, the diode rectifier is used to build up DC link voltage from AC source. The diode rectifier is simple and cheap but it brings out the problems of low power factor and plentiful harmonics at the AC source. Also It can derate the utilization rate of solar energy because the reverse of power flow cannot be made. Hence, in this paper to overcome the peak power problem in summer and to endure good AC input characteristics, solar air conditioning system using the PWM converter is proposed. As results, obtained are the characteristics of the PWM converter such as low distorted current waveform, high power factor and bidirectional power control. And also the stability of proposed system is verified by examining the dynamics of step load change and power reversal testing. (author). refs., figs., tabs.

  • PDF

A study on the power control algorithm for ultrasonic retrieval system (초음파 원격 이탈제어 시스템용 전력제어 알고리즘 개발)

  • Kim, Young-Jin;Jeong, Han-Cheol;Huh, Kyung-Moo;Cho, Young-June
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.113-115
    • /
    • 2005
  • To explore the seafloor, an observation instrument should be laid there for a long time and it should be again withdrawn. This system must be designed low power consumption model because it operates for a long period, but because power control don't execute or simply control algorithm executes, power efficiency is low. Hereupon, a power control algorithm for retrieval system using the ultrasonic communication that was improved its controllability and movability was presented in this paper. Likewise, the logicality of control algorithm and remote control system were ascertained by experiments.

  • PDF

The Power Performance Testing for 3MW Wind turbine System (3MW 풍력발전시스템 출력성능평가에 관한 연구)

  • Ko, Suk-Whan;Jang, Moon-Seok;Park, Jong-Po;Lee, Yoon-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.19-26
    • /
    • 2011
  • We are carried out power performance testing for 3MW wind turbine system at Je-ju wind turbine testing Site and analyzed measured data which was stored through monitoring system. In this paper, we described the power performance testing results and analyzed an uncertainty of measured data sets. The power curve with measured power data is closely coincide with designed power curve except for the low wind speed sections(4m/s~7m/s) and the annual energy production which is given Ray leigh distribution was included with 1.5~5.9% of uncertainty in the wind speed region as 4~11m/s. Although the deviation of curve between measured power and designed power is high, the difference of annual energy production is low in the low wind speed region.

Economic Analysis and Comparison between Low-Power and High-Power SOEC Systems (저출력 및 고출력 SOEC 시스템의 경제성 분석 비교)

  • TUANANH BUI;YOUNG SANG KIM;DONG KEUN LEE;KOOK YOUNG AHN;YONGGYUN BAE;SANG MIN LEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.6
    • /
    • pp.707-714
    • /
    • 2022
  • Hydrogen production using solid oxide electrolysis cells (SOEC) is a promising technology because of its efficiency, cleanness, and scalability. Especially, high-power SOEC system has received a lot of attention from researchers. This study compared and analyzed the low-power and high-power SOEC system in term of economic. By using revenue requirement method, levelized cost of hydrogen (LCOH) was calculated for comparison. In addition, the sensitivity analysis was performed to determine the dependence of hydrogen cost on input variables. The results indicated that high-power SOEC system is superior to a low-power SOEC system. In the capital cost, the stack cost is dominant in both systems, but the electricity cost is the most contributed factor to the hydrogen cost. If the high-power SOEC system combines with a nuclear power plant, the hydrogen cost can reach 3.65 $/kg when the electricity cost is 3.28 ¢/kWh and the stack cost is assumed to be 574 $/kW.

An 8-bit 40 Ms/s Folding A/D Converter for Set-top box (Set-top box용 an 8-bit 40MS/s Folding A/D Converter의 설계)

  • Jang, Jin-Hyuk;Lee, Ju-Sang;Yu, Sang-Dae
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.626-628
    • /
    • 2004
  • This paper describes an 8-bit CMOS folding A/D converter for set-top box. Modular low-power, high-speed CMOS A/D converter for embedded systems aims at design techniques for low-power, high-speed A/D converter processed by the standard CMOS technology. The time-interleaved A/D converter or flash A/D converter are not suitable for the low-power applications. The two-step or multi-step flash A/D converters need a high-speed SHA, which represents a tough task in high-speed analog circuit design. On the other hand, the folding A/D converter is suitable for the low-power, high-speed applications(Embedded system). The simulation results illustrate a conversion rate of 40MSamples/s and a Power dissipation of 80mW(only analog block) at 2.5V supply voltage.

  • PDF

A Development of Visualization Software for Protective Engineering in Low-Voltage Power Systems (저압계통 보호 엔지니어링을 위한 시각화 소프트웨어 개발)

  • Yun, Sang-Yun;Lee, Nam-Ho;Lee, Wook-Hwa;Lee, Jin;Kim, Jae-Chul
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.7
    • /
    • pp.297-305
    • /
    • 2006
  • This paper summarizes a development of visualization software for protective engineering in low-voltage power systems. The study is concentrated on the following aspects. First, a software engineering method is applied for designing the object-oriented program. The design and implementation of a Graphic User Interface(GUI) and its integration to a power system framework are developed using object-oriented programming(OOP) in Visual C++. Second, we develop the short circuit analysis module that oriented a low-voltage power system. It is possible to calculate a peak, symmetrical RMS, DC component and asymmetrical fault currents for each time. And it is the first software that can calculate the fault current for single branch of three-phase system. The calculation accuracy is compared with commercial software, and the libraries of low-voltage components are served for convenience use. Third, protective engineering functions are equipped. It is possible to automatically select the circuit breaker which based on the user input characteristics and the fault current calculation and examine the protective coordination. Through the case study, we verified that the developed software can be effectively used to examine the protective engineering in low-voltage power systems.

Effect Analysis of the Low Frequency Oscillation Mode of Inter-area System According to Load Characteristics (부하특성이 지역간 계통의 저주파 진동 모드 해석에 미치는 영향 분석)

  • Kim, Hak-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1703-1707
    • /
    • 2008
  • Low frequency oscillation of inter-area system is important problem in power system areas because the operation conditions of power system depend on it. Generally, the analysis of the problem is used by small signal stability. Especially, the analysis results are affected by decision of load models. In this paper, the effect of the analysis results was studied according to load component characteristics. ZIP model, popular in large-scaled power system analysis, was used as the load model. Many cases were studied according to the combination of ZIP model in inter-area system.

Design of a Low Power Self-tuning Digital System Considering Aging Effects (노화효과를 고려한 저전력 셀프 튜닝 디지털 시스템의 설계)

  • Lee, Jin-Kyung;Kim, Kyung Ki
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.13 no.3
    • /
    • pp.143-149
    • /
    • 2018
  • It has become ever harder to design reliable circuits with each nanometer technology node; under normal operation conditions, a transistor device can be affected by various aging effects resulting in performance degradation and eventually design failure. The reliability (aging) effect has traditionally been the area of process engineers. However, in the future, even the smallest of variations can slow down a transistor's switching speed, and an aging device may not perform adequately at a very low voltage. Therefore, circuit designers need to consider these reliability effects in the early stages of design to make sure there are enough margins for circuits to function correctly over their entire lifetime. However, such an approach excessively increases the size and power dissipation of a system. As the impact of reliability, new techniques in designing aging-resilient circuits are necessary to reduce the impact of the aging stresses on performance, power, and yield or to predict the failure of a system. Therefore, in this paper, a novel low power on-chip self-tuning circuit considering the aging effects has been proposed.

Design and Performance Evaluation of OFDM-Based Low Power Communication System (OFDM 기반 저전력 통신 시스템 설계와 성능 평가)

  • Choi, Jae-Hoon;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.10
    • /
    • pp.951-959
    • /
    • 2011
  • The low power consumption modulation is required for short range communication. In this paper, we analyze performance of low power consumption modulation scheme such as PSPM, PSSK and QAPM using OFDM transmission in AWGN channel. A PSPM, PSSK and QAPM modulation scheme are decrease in bandwidth efficiency but improved power efficiency than existing PSK and QAM. These modulation schemes can achieve power efficiency because every symbol of modulations has a zero-envelope period like PPM techniques. The OFDM system is high bandwidth efficiency than single carrier system. In this paper, we are propose the frequency domain mapping method for OFDM transmission using low power consumption modulation method. Also, we compare low power OFDM communication system regard to BER performance, throughput and PAPR.