• Title/Summary/Keyword: low-level controller

Search Result 189, Processing Time 0.047 seconds

A Hierachical Controller for Soccer Robots (축구로봇을 위한 계층적 제어기)

  • Lee, In-Jae;Baek, Seung-Min;Sohn, Kyung-Oh;Kuc, Tae-Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.9
    • /
    • pp.803-812
    • /
    • 2000
  • In this paper we introduce a model based centralized hierarchical controller for cooperative team of soccerplaying multiple mobile robots. The hierarchical controller is composed of high-level and low-level controllers. Using the coordinates information of objects from the vision are simple models of multiple mobile tobots on the playground. Subsequently, the high level controller selects and action model corresponding to the perceived state transition model and generates subgoal and goal-velocity, from which the low level controller generates trajectory of each wheel velocity of the robot. This two layered simplicity. The feasubility of the control strategy has been demonstrated in an implementation for real soccer games at a MiroSot league.

  • PDF

Application of Fuzzy Algorithm with Learning Function to Nuclear Power Plant Steam Generator Level Control

  • Park, Gee-Yong-;Seong, Poong-Hyun;Lee, Jae-Young-
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.1054-1057
    • /
    • 1993
  • A direct method of fuzzy inference and a fuzzy algorithm with learning function are applied to the steam generator level control of nuclear power plant. The fuzzy controller by use of direct inference can control the steam generator in the entire range of power level. There is a little long response time of fuzzy direct inference controller at low power level. The rule base of fuzzy controller with learning function is divided into two parts. One part of the rule base is provided to level control of steam generator at low power level (0%∼30% of full power). Response time of steam generator level control at low power level with this rule base is shown generator level control at low power level with this rule base is shown to be shorter than that of fuzzy controller with direct inference.

  • PDF

A Fuzzy Logic Controller for the Level Swell and Shrinkage of the Nuclear Steam Generators

  • Moon, Byung-Soo;Moon, Je-Sun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.260-265
    • /
    • 1995
  • Based on a thermohydraulic estimation of the level swell and shrinkage of the nuclear steam generators, a fuzzy logic controller is designed and tested to handle the problem of controlling the level swell and its restoration. The estimation is used to form an artificial system which is nearly the opposite of the level swell and shrinkage and a PD type controller is designed to control this system. This controller is added to a PI type ordinary fuzzy logic controller to form the proposed controller which is tested through various experiments on a scaled-down steam generator. It is found to perform efficiently so that the divergence of the level to a low limit can be avoided.

  • PDF

The devlepment of a MPC controller for water level control in the steam generator of a nuclear power plant (원전 증기발생기 수위제어를 위한 MPC 제어기 개발)

  • 손덕현;한진욱;이환섭;이창구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.359-359
    • /
    • 2000
  • Generally, level control in the steam generator of a nuclear power plant is difficulty process control, because the low power operating can lead nonminimum phase characteristics(swell and shrink phenomenon) and flow measurement are unreliable and nonlinear characteristics. This paper presents a framework for solving this problem based on the constrained linear model predictive control and introduces the design of method for the level of the controller in the entire operating power of the steam generator, and compares with conventional PI controller.

  • PDF

A Supervisor-Based Neural-Adaptive Shift Controller for Automatic Transmissions Considering Throttle Opening and Driving Load

  • Shin, Byung-Kwan;Hahn, Jin-Oh;Yi, Kyong-Su;Lee, Kyo-II
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.418-425
    • /
    • 2000
  • Recently, many passenger cars have adopted automatic transmissions for shifting gears, and thus the smooth and precise control of gear shifts of passenger car automatic transmissions has become more and more essential for the riding comfort of vehicles equipped with automatic transmissions. In this article, a neural network-based supervisor for an automotive shift controller considering the throttle opening, variations in throttle opening, and the driving load is presented. For using the driving load information, an observer-based driving load estimation algorithm is proposed. A proportional-integral-derivative controller along with an open loop controller is used as a low level controller for controlling the gear shifts, and a supervisory controller for properly adapting the shift control parameters of the low level shift controller is designed using ANFIS. To evaluate the control performance of the proposed supervisor-based shift controller, both simulation studies and experimental studies are performed for various shifting situations.

  • PDF

Reliable stabilizing multi-controller for steam generator level control (증기발생기 수위제어를 위한 다중 안정화 제어기 설계)

  • 권현진;박상현;이상정;함창식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1229-1232
    • /
    • 1996
  • This paper proposes the passive redundancy algorithm of multi-controller structure applicable to the steam generator level control system in the low power operating range. In the passive redundancy scheme of multi-controller structure, two suitable controllers exist if the plant is strongly stabilizable. One of the two controllers can be selected arbitrarily only if it is stable. In particular, this paper shows that the passive redundancy scheme can be efficiently used with PID and GPC control algorithms through simulation studies on the control of the steam generator.

  • PDF

A 0.25-$\mu\textrm{m}$ CMOS 1.6Gbps/pin 4-Level Transceiver Using Stub Series Terminated Logic Interface for High Bandwidth

  • Kim, Jin-Hyun;Kim, Woo-Seop;Kim, Suki
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.165-168
    • /
    • 2002
  • As the demand for higher data-rate chip-to-chip communication such as memory-to-controller, processor-to-processor increases, low cost high-speed serial links\ulcorner become more attractive. This paper describes a 0.25-fm CMOS 1.6Gbps/pin 4-level transceiver using Stub Series Terminated Logic for high Bandwidth. For multi-gigabit/second application, the data rate is limited by Inter-Symbol Interference (ISI) caused by channel low pass effects, process-limited on-chip clock frequency, and serial link distance. The proposed transceiver uses multi-level signaling (4-level Pulse Amplitude Modulation) using push-pull type, double data rate and flash sampling. To reduce Process-Voltage-Temperature Variation and ISI including data dependency skew, the proposed high-speed calibration circuits with voltage swing controller, data linearity controller and slew rate controller maintains desirable output waveform and makes less sensitive output. In order to detect successfully the transmitted 1.6Gbps/pin 4-level data, the receiver is designed as simultaneous type with a kick - back noise-isolated reference voltage line structure and a 3-stage Gate-Isolated sense amplifier. The transceiver, which was fabricated using a 0.25 fm CMOS process, performs data rate of 1.6 ~ 2.0 Gbps/pin with a 400MHB internal clock, Stub Series Terminated Logic ever in 2.25 ~ 2.75V supply voltage. and occupied 500 * 6001m of area.

  • PDF

Controller Design and Dynamic Performance Analysis of UPFC based on 3-Level Inverters (3-레벨 인버터 UPFC의 제어기설계와 동특성해석)

  • Han, Byeong-Mun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.6
    • /
    • pp.272-279
    • /
    • 2000
  • This paper describes a controller design and dynamic performance analysis of UPFC based on 3-level inverters. Major attention is focused on the controller design for both shunt and series inverters, including regulator design for the dc link voltage sharing across the dc capacitors. An energy-based approach was investigated for effectively designing the controller. A detailed UPFC model has been developed with EMTP using 24-pulse 3-level inverters to verify this approach. Simulation results about dynamic performance of UPFC confirm effects for increasing transmission capacity and damping low-frequency oscillation. The developed simulation model would be very effective to analyze the dynamic performance of UPFC.

  • PDF

Development of a Self-tuning Fuzzy-PID Controller for Water Level of Steam Generator (증기발생기 수위제어를 위한 자기동조 퍼지 PID 제어기 개발)

  • Han, Jin-Wook;Lee, Chang-Goo;Han, Hoo-Seuk
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1251-1258
    • /
    • 1999
  • The water level control of a steam generator in the unclear power plant is an important process. Most of the water level controllers of the actual plant are PID controllers. But they have limitations in appling for tracking the set point and getting rid of disturbances, so there are some defects to apply in the actual ground even though many research works represented the resolutions to solve it. In this paper, it is suggested that the established simple PID controller in low power has the ability to remove disturbances and trace the set-point, and then possesses the real-time self-tuning function according to the variety of moving peculiarity of a plant. This function realized by making use of fuzzy logic. PID parameters are formulated by a variable ${\alpha}$ and made it fluctuate by a fuzzy inference according to level error and level error change. This mechanism makes application of actual plant effective as well as taking advantage of improving the efficiency of water level controller by way of adding the function of self-tuning instead of replacing PID controller. The computer simulation of this scheme shows the improved performance compare to conventional PID controller.

  • PDF

THE MODEL PREDICTIVE CONTROLLER FOR THE FEEDWATER AND LEVEL CONTROL OF A NUCLEAR STEAM GENERATOR

  • Lee, Yoon Joon;Oh, Seung Jin;Chun, Wongee;Kim, Nam Jin
    • Nuclear Engineering and Technology
    • /
    • v.44 no.8
    • /
    • pp.911-918
    • /
    • 2012
  • Steam generator level control at low power is difficult due to its adverse thermal hydraulic properties, and is usually conducted by an operator. The basic model predictive control (MPC) is similar to the action of an operator in that the operator knows the desired reference trajectory for a finite period of time and takes the necessary control actions needed to ensure the desired trajectory. An MPC is based on a model; the performance as well as the efficiency of the MPC depends heavily on the exactness of the model. In this study, steam generator models that can describe in detail its thermal hydraulic behaviors, particularly at low power, are used in the MPC design. The design scope is divided into two parts. First, the MPC feedwater controller of the feedwater station is determined, and then the MPC level controller for the overall system is designed. Because the dynamic properties of a steam generator change with the power levels, a realistic situation is simulated by changing the transfer functions of the steam generator at every time step. The resulting MPC controller shows good performance.