• 제목/요약/키워드: low-field measurement

Search Result 562, Processing Time 0.031 seconds

Sol-Gel Synthesis, Crystal Structure, Magnetic and Optical Properties in ZnCo2O3 Oxide

  • Das, Bidhu Bhusan;Barman, Bittesh
    • Journal of the Korean Chemical Society
    • /
    • v.63 no.6
    • /
    • pp.453-458
    • /
    • 2019
  • Synthesis of ZnCo2O3 oxide is performed by sol-gel method via nitrate-citrate route. Powder X-ray diffraction (XRD) study shows monoclinic unit cell having lattice parameters: a = 5.721(1) Å, b = 8.073(2) Å, c = 5.670(1) Å, β = 93.221(8)°, space group P2/m and Z = 4. Average crystallite sizes determined by Scherrer equation are the range ~14-32 nm, whereas SEM micrographs show nano-micro meter size particles formed in ZnCo2O3. Endothermic peak at ~798 K in the Differential scanning calorimetric (DSC) trace without weight loss could be due to structural transformation and the endothermic peak ~1143 K with weight loss is due to reversible loss of O2 in air atmosphere. Energy Dispersive X-ray (EDX) analysis profile shows the presence of elements Zn, Co and O which indicates the purity of the sample. Magnetic measurements in the range of +12 kOe to -12 kOe at 10 K, 77 K, 120 K and at 300 K by PPMS-II Physical Property Measurement System (PPMS) shows hysteresis loops having very low values of the coercivity and retentivity which indicates the weakly ferromagnetic nature of the oxide. Observed X-band EPR isotropic lineshapes at 300 K and 77 K show positive g-shift at giso ~2.230 and giso ~2.217, respectively which is in agreement with the presence of paramagnetic site Co2+(3d7) in the oxide. DC conductivity value of 2.875 ×10-8 S/cm indicates very weakly semiconducting nature of ZnCo2O3 at 300 K. DRS absorption bands ~357 nm, ~572 nm, ~619 nm and ~654 nm are due to the d-d transitions 4T1g(4F)→2Eg(2G), 4T1g(4F)→4T1g(4P), 4T1g(4F)→4A2g(4F), 4T1g(4F)→4T2g(4F), respectively in octahedral ligand field around Co2+ ions. Direct band gap energy, Eg~ 1.5 eV in the oxide is obtained by extrapolating the linear part of the Tauc plot to the energy axis indicates fairly strong semiconducting nature of ZnCo2O3.

Sapphire Based 94 GHz Coplanar Waveguide-to-Rectangular Waveguide Transition Using a Unilateral Fin-line taper (평면형 Fin-line 테이퍼를 이용한 사파이어 기반의 94 GHz CPW-구형 도파관 변환기)

  • Moon, Sung-Woon;Lee, Mun-Kyo;Oh, Jung-Hun;Ko, Dong-Sik;Hwang, In-Seok;Rhee, Jin-Koo;Kim, Sam-Dong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.10
    • /
    • pp.65-70
    • /
    • 2008
  • We design and fabricate the 94 GHz Coplanar waveguide(CPW)-to-rectangular waveguide transition that is transmits signal smoothly between the CPW, which is a popular transmission line of the planar circuits, and rectangular waveguide for the 94 GHz transceiver system. The proposed transition composed of the unilateral fin-line taper and open type CPW-to-slot-line transition is based on the hard and inflexible sapphire for the flip-chip bonding of the planar MMICs using conventional MMIC technology. We optimize a single section transition to achieve low loss by using an EM field solver of Ansoft's HFSS and fabricate the back- to-back transition that is measured by Anritsu ME7808A Vector Network Analyzer in a frequency range of $85{\sim}105$ GHz. From the measurement and do-embedding CPW with 3 mm length, an insertion and return loss of a single-section transition are 1.7 dB and more an 25 than at 94 GHz, respectively.

Scientific Missions and Technologies of the ISSS on board the NEXTSat-1

  • Choi, Cheong Rim;Sohn, Jongdae;Lee, Jun-Chan;Seo, Yong Myung;Kang, Suk-Bin;Ham, Jongwook;Min, Kyoung-Wook;Seon, Jongho;Yi, Yu;Chae, Jang-Soo;Shin, Goo-Hwan
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.1
    • /
    • pp.73-81
    • /
    • 2014
  • A package of space science instruments, dubbed the Instruments for the Study of Space Storms (ISSS), is proposed for the Next Generation Small Satellite-1 (NEXTSat-1), which is scheduled for launch in May 2016. This paper describes the instrument designs and science missions of the ISSS. The ISSS configuration in NEXTSat-1 is as follows: the space radiation monitoring instruments consist of medium energy particle detector (MEPD) and high energy particle detector (HEPD); the space plasma instruments consist of a Langmuir probe (LP), a retarding potential analyzer (RPA), and an ion drift meter (IDM). The space radiation monitoring instruments (MEPD and HEPD) measure electrons and protons in parallel and perpendicular directions to the geomagnetic field in the sub-auroral region, and they have a minimum time resolution of 50 msec for locating the region of the particle interactions with whistler mode waves and electromagnetic ion cyclotron (EMIC) waves. The MEPD measures electrons and protons with energies of tens of keV to ~400 keV, and the HEPD measures electrons with energies of ~100 keV to > ~1 MeV and protons with energies of ~10 MeV. The space plasma instruments (LP, RPA, and IDM) observe irregularities in the low altitude ionosphere, and the results will be compared with the scintillations of the GPS signals. In particular, the LP is designed to have a sampling rate of 50 Hz in order to detect these small-scale irregularities.

Effect of Fertilizer Application and Planting Method on Growth and Yield of 'Seolhyang' Strawberry in Seedling Stage (육묘과정 중 배양액 추비시용과 정식방법에 따른 '설향' 딸기 생육 및 수량에 미치는 영향)

  • Park, Gab-Soon;Kang, Tae-Ju;Kim, Young-Chil;Ann, Seoung-Won
    • Journal of Environmental Science International
    • /
    • v.24 no.2
    • /
    • pp.197-205
    • /
    • 2015
  • This study was performed to identify the effect of fertilizer application and planting method on growth and yield of 'Seolhyang' strawberry during seedling raising. According to the concentration of fertilizer applied, the height of daughter plants was the highest at an EC of $0.8dS{\cdot}m^{-1}$. Leaf number and crown diameter were greatest at an EC of $0.6-0.8dS{\cdot}m^{-1}$. In the first measurement, root number was highest in non-fertilizer application, while root weight was heaviest in non-fertilizer application and EC $0.4dS{\cdot}m^{-1}$. The higher the concentration of fertilizer applied as culture media, the lower the growth rate. Thirty days after planting on the main field, plant height and number of new leaf were highest at an EC of $0.8dS{\cdot}m^{-1}$. However, no significant difference was found in leaf length and width and chlorophyll content according to fertilizer application. Marketable yield of 25 g or higher was greatest in EC $0.6dS{\cdot}m^{-1}$. In contrast, no significance was found in total marketable yield at an EC of $0.4-0.8dS{\cdot}m^{-1}$. Aconsistent pattern was exhibited in the growth of 1-5 harvesting flower clusters according to planting method. The length of leaf and flower cluster was short and chlorophyll content was low, when bed soil was removed 100% in harvesting of the first flower cluster. In all treatment, leaf length was shortened until harvesting of the second and third flower cluster, but rapidly lengthened in harvesting of the third and fourth flower clusters. Moreover, the length of flower cluster had a increasing tendency from harvesting of the third flower cluster. However, chlorophyll content was reduced continuously until harvesting of the fifth flower cluster, and was lowest in harvesting of the fourth flower cluster without removal of bed soil. Total yield was greatest in treatment of crown removal in bed soil between November and May. Late marketable yield between March and May was highest in treatment of 100% bed soil removal, followed by treatment of crown removal. Marketable yield of 25 g or higher was greatest in treatment of crown removal between December and February, while greatest in treatment of 100% bed soil removal between March and May.

Analysis of Question Patterns Appearing in Teaching Demonstrations Which Applied Science Teachings Model Prepared by a Pre-service Biology Teacher (생물 예비교사의 과학수업모형을 적용한 수업 시연에 나타난 질문 유형 분석)

  • Jo, In Hee;Son, Yeon-A;Kim, Dong Ryeul
    • Journal of Science Education
    • /
    • v.36 no.2
    • /
    • pp.167-185
    • /
    • 2012
  • This study aimed at finding points of improvement in teaching expertise by analyzing the question patterns that appeared during teaching demonstrations which applied science teaching models prepared by a pre-service biology teacher. The question analysis frame for analyzing question types were categorized largely into the question types of Category 1 (questions in cognitive domain, questions with research function, questions in affective domain), Category 2 (repeated questions, questions for narrowing the range, practice questions), and Category 3 (questions on student activity progress, memory questions, and thinking questions). The results of analyzing question patterns from five different science teaching models revealed a high frequency of questions in the fields of cognition and memory. For the circular learning model, questions from the cognitive field appeared the most often, while, student activity progressive questions in particular were used mostly in the 'preliminary concept introduction stage' of the circular learning model and the 'secondary exploratory stage', in which experiments were conducted, and displayed the characteristics of these stages. The discovery learning model combined the courses of observation, measurement, classification and generalization, but, during teaching demonstrations, memory questions turned up the most, while the portion of inquisitive function questions was low. There were many questions from the inquisitive learning model, and, compared to other learning models, many exploratory function questions turned up during the 'experiment planning stage' and 'experiment stage'. Definitional questions and thought questions for the STS learning model turned up more than other learning models. During the change of concept learning model, the five concepts of students were stimulated and the modification of scientific concepts was very much aided by using many memory questions.

  • PDF

A Study on the Nutritional Assessment of Early Childhood Using Mid-Upper-Arm Circumference (상박위(上膊圍)에 의(依)한 성장기(成長期) 아동(兒童)에 영양상태(營養狀態)의 판정(判定)에 관(關)한 연구(硏究))

  • Tchai, B.S.;Nam, Y.K.;Chung, Y.J.
    • Journal of Nutrition and Health
    • /
    • v.8 no.4
    • /
    • pp.9-14
    • /
    • 1975
  • Growth retardation and a variable degree of body disproportion are recognized features of malnutrition, and mild and moderate protein-calorie malnutrition(PCM). Among the various body measurements suggested to assess the prevalence of all grades of PCM as judged by growth retardation and by body disproportion, the 'mid-upper-arm circumference'-abbreviated to 'arm-circumference' has been suggested as a potential useful simple field index for the assessment of PCM showing that the measurement would give composite information simultaneously on three important effects on PCM-deficit in the muscle protein reservoirs, availability of calorie stores in the form of subcutaneous fat, and growth failure. And this is selected because of its easy accessibility, and less involvement with clinical edema. This study is conducted to make a comparison between the percentage of Korean weight for age standards and the percentage of mid-upper-arm circumference for age standards of 175 preschool children aged $3{\sim}72$ months who are selected among the low-income residents in Seoul. In this study, a comparison is made between the results obtained by expressing the observed weight of the child as a percentage of Korean standard, referred to as 'weight-for-age' and the observed arm-circumference expressed as a percentage of the age-specific arm standard of Jelliffe, referred to as 'arm-for-age'. All the measurements were taken following the techniques described by Jelliffe. The left mid upper arm was measured using a glass-fibre tape and the Fairbanks Morse beam balance was used for weighing. 80% level of weight for age Korean standard and 85% level of arm for are Jelliffe standard were used as an upper borderline limit for PCM. Comparing the 80% weight-for-age and the 85% arm-for-age standard as an upper limit for PCM, for children aged $3{\sim}72$ months, results in 84.6% agreement with the sensitivity of 86.4% and its specificity of 83.5%. If arm circumference alone had been measured and judgement made on this basis, then only 5.1% of the children would have been 'wrongly' classified. And there is a moderately close correlation between arm circumference and weight for age as the data in Table 4 shows. The problem therefore lies in the standard for arm circumference in normal children and in determining what is the lower limit of normal. Once this is clearly difined, one can rely more confidently on arm circumference measurements alone for the nutritional assessment of early childhood.

  • PDF

Required Mowing Power and Bale Density of Miscanthus × Giganteus for Field Biomass Harvesting using Different Methods

  • Jun, Hyeon-Jong;Choi, Il-Su;Kang, Tae-Gyoung;Choi, Yong;Choi, Duck-Kyu;Lee, Choung-Keun
    • Journal of Biosystems Engineering
    • /
    • v.39 no.4
    • /
    • pp.253-260
    • /
    • 2014
  • Purpose: This study investigated the harvesting properties of the giant miscanthus (Miscanthus ${\times}$ giganteus) to measure the required mowing power for different stem conditioning methods in order to shorten the drying time after mowing and the bale density so that the crop can be used as biomass in the winter season. Methods: The required mowing power and bale density were measured using a power measurement device, three different mower-conditioners, and a mid-sized round baler under different working speeds and conditioning methods. Results: For the various mower-conditioners, the average stem length from mowing was 0.86-0.91 m, and the available working speed was 1.6 m/s. The steel roller-type mower-conditioner showed better stem conditioning but could not mow over a working speed of 1.6 m/s. The required average power of the mower-conditioners varied from 23.8 kW for the steel roller-type rotary disk mower-conditioner with a working width of 2.4 m to 37.2 kW for the flail-type rotary disk mower-conditioner with a working width of 3.2 m at a working speed of 1.6 m/s. The bale densities were $155.8-172.2kg/m^3$. The highest bale density was measured for stems with no conditioning and a moisture content of 11.3% (d.b.) mowed by the rotary disk mower. The bale density was affected by the mowing method because of the low moisture content of the miscanthus stems. Conclusions: In terms of the working performance and conditioning statue, the steel roller-type mower-conditioner is a better choice at a working width of 2.4 m, while the flail finger-type mower-conditioner is better at a working width of 3.2 m. The type of mower-conditioner used for giant miscanthus harvesting should be determined by considering the harvest area, workable period, and working performance of a mower-conditioner and baler during the winter.

Comparison of the Real-time Measurements for PM2.5 and Quality Control Method (PM2.5 자동측정장비 비교 및 정도관리 방안)

  • Park, Mikyung;Park, Jin Su;Jo, Mira;Lee, Yong Hwan;Kim, Hyun Jae;Oh, Jun;Choi, Jin Soo;Ahn, Joon Young;Hong, You Deog
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.6
    • /
    • pp.616-625
    • /
    • 2017
  • Measurements using five real-time particle samplers were compared to measurements using three NRM (National Reference Method system) filter-based samplers(Gravimetric method) at Incheon, Korea, between May and August, 2014. The purpose of this study was to suggest the quality assurance/quality control (QA/QC) method of each instrument for use in a real-time continuous particle sampler to measure the mass of airborne particles with an aerodynamic diameter less than $2.5{\mu}m$ ($PM_{2.5}$). Five real-time particle samplers of BAM1020, FH62C_14, TEOM, PM-711 and SPM-613 were evaluated by comparing its measured 23 hr average $PM_{2.5}$ concentrations with those measured with NRM filter-based samplers simultaneously. The parameters(e.g. Inlet heating condition, Slope factor, Film response, Intercept, Background, Span value) of the real-time samplers were optimized respectively by conducting test performance evaluation during 7 days in field sampling. For example, inlet heating temperature of TEOM sampler controls $35{\sim}40^{\circ}C$ to minimize the fluctuation of the real-time measurement data and background value of BAM1020 is the key factor affecting the accuracy of $PM_{2.5}$ mass concentration. We classified the $PM_{2.5}$ concentration according to relative humidity (80%) to identify water absorbed in aerosols by measuring the ${\beta}$-ray samplers(BAM1020, FH62C_14) and TEOM. ${\beta}$-ray samplers were not strongly affected by relative humidity that the difference of the average $PM_{2.5}$ concentration was about 5%. On the other hand, The TEOM sampler overestimated $PM_{2.5}$ mass concentration about 15% at low relative humidity (<80%).

A Study on the Structural Relation of Vietnamese Consumer's Green Purchase Behavior (그린구매행동의 구조적 관계에 관한 연구)

  • Thanh, Huyen;Park, Ju-Sik
    • Management & Information Systems Review
    • /
    • v.35 no.3
    • /
    • pp.131-153
    • /
    • 2016
  • This research suggests a structural model of green purchase behavior, focusing on the moderating effect of affordability. Affordability means buying power or ability to buy products. Based on the literature review, a research model of behavior of buying green products was proposed and tested empirically using the field study. To examine the proposed research model, the reliability and validity verifications on measurement items were carried out and then the structural equation model analysis was applied to test the model. Lastly, to test the moderating effect of affordability, a two-group model(using Amos program) was used subsequently so that it could be determined whether or not there was any significant difference in structural parameters between the high affordability group and the low affordability group. The empirical results are as follow: Firstly, green purchase attitude is influenced by ecological concern and collectivism, then green purchase attitude has an impact on green purchase intention, and in turn, green purchase intention affects green purchase behavior. Secondly, affordability significantly moderates the relationship between green purchase intention and green purchase behavior. These results are consistent with the past researches and based on them, some managerial implications are given.

  • PDF

Optical Current Sensors with Improved Reliability using an Integrated-Optic Reflective Interferometer (반사형 간섭계를 이용하여 신뢰성을 향상시킨 광전류센서)

  • Kim, Sung-Moon;Chu, Woo-Sung;Oh, Min-Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.5
    • /
    • pp.17-23
    • /
    • 2017
  • Optical current sensors are suitable for operation in high voltage and high current environments such as power plants due to they are not affected by electromagnetic interference and have excellent insulation characteristics. However, as they operate in a harsh environment such as large temperature fluctuation and mechanical vibration, high reliability of the sensor is required. Therefore, many groups have been working on enhancing the reliability. In this work, an integrated optical current sensor incorporating polarization-rotated reflection interferometer is proposed. By integrating various optical components on a single chip, the sensor exhibits enhanced stability as well as the solution for low-cost optical sensors. Using this, we performed the characterization for the actual field application. By using a large power source, the current of 0.3 kA~36 kA was applied to the photosensor and the linear operation characteristics were observed. The error of the sensor was within $0{\pm}.5%$. Even when operating for a long time, the error range of the sensor was kept within $0{\pm}.5%$. In addition, the measurement of the frequency response over the range of 60 Hz to 10 kHz has confirmed that the 3-dB frequency band of the proposed OCT is well over 10 kHz.