• 제목/요약/키워드: low viscosity, low toxicity

검색결과 9건 처리시간 0.032초

아크릴레이트계 주입약액의 특성 및 적용 (Characteristics and Applications of Acrylate Injection Material)

  • 천병식;류동성;조산연;정성남;여유현
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.539-542
    • /
    • 1999
  • In this study, acrylate salt material of new chemical composition for injection grouting was prepared in the state of aqueous solution, and the chemical and physical properties of the material were investigated. The gelation time of the material was freely controllable through the control of added catalysts amount. As the viscosity of the material was very low (2∼3cps), its injection efficiency was expected to be very excellent. The variation of its viscosity plotted with the process of gelation revealed that the efficiency of its penetration into the ground soil was very excellent. The LD$\sub$50/ test on white mouse verified the toxicity of the material was very slight and substantially negligible. The grouting effect using the material was examined through field case histories.

  • PDF

폴리아크릴아마이드를 함유한 에멀젼의 유변학적 거동 (Rheological Behaviour of Emulsions Containing Polyacrylamide)

  • 조완구;김송이
    • 한국응용과학기술학회지
    • /
    • 제27권2호
    • /
    • pp.99-106
    • /
    • 2010
  • We have investigated the rheological behaviours of emulsions containing polymers. The polymers used in this study were polyacrylamide and carboxy vinyl polymer. The emulsion with polyacrylamide shows better prior preference than that with carboxy vinyl polymer on the skin texture. In the toxicity test, such as, LLNA cell toxicity, skin organ culture and human patch test, polyacrylamide was the appropriate materials for the cosmetics. The viscosity of polyacrylamide shows maximum value in neutral pH and good stability against temperature. The decreasing effect of viscosity against salt was not good enough but showed a better result than that of carboxy vinyl polymer. Two times the amount of polyacrylamide should be used for the formation of a similar viscosity of carboxy vinyl polymer. Yield value of polyacrylamide was low and the effect for the stabilizing emulsions was also low.

Effect of Polymerization Conditions on the Characteristics of Polyvinyl Acetate Emulsions

  • Youn, Hye-Jung;Lee, Hak-Lae
    • 펄프종이기술
    • /
    • 제30권4호
    • /
    • pp.28-34
    • /
    • 1998
  • Polyvinyl acetate emulsion has been widely used as adhesives for wood and paper, paint additives and binders for fiber, leather, and other materials because it is an excellent adhesive with many advantages including low in toxicity risks and manufacturing cost. It is expected the consumption of polyvinyl acetate emulsion as adhesives will increase in cigarette industry as well as in paperboard coating industry. Recently the operation speed of the cigarette tip wrapper increased so substantially that improvement of the emulsion properties is required including good wet tack development, narrow and controlled particle size distribution, low viscosity, etc. In this study the effects of such polymerization conditions as the type and amount of emulsifier, internal or external plasticizing, and emulsification methods on the viscosity and particle size of polyvinyl acetate emulsions were examined. Results showed that polyvinyl alcohol with a high degree of hydrolysis and low molecular weight and nonionic surfactants are superior to anionic surfactant in improving adhesion and emulsion stability. They also tend to produce emulsions with smaller particle size. External plasticization with dipropylene glycol dibenzoate was more effective in improving flexibility than internal plasticization with butyl acrylate. Monomer emulsification under high shear was more effective in decreasing the particle size.

  • PDF

철도차량 및 지하철 불연 내장재 페놀 SMC 개발 (Development of Phenolic SMC for The Rail)

  • 김영근;신동혁;김영민;박종욱;민재준
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2004년도 춘계학술발표대회 논문집
    • /
    • pp.55-58
    • /
    • 2004
  • Phenolin resin, prepared form phenol and formaldehyde, is one of the oldest thermosetting resins available. Phenolic resins are cured via condensation polymerization with evolution of water, which in molding process is a big problem. The use of phenolic resins in glass fiber composites is growing, primarily due to their low flame spread, low smoke generation and low smoke toxicity properties. SMC of phenolics has been rearched since the 1986. The technology challenge was to match resin viscosity, handling and cure with those for the polyester SMC to avoid any special processing for fabricators and end users. Phenolic SMC was chosen because of the ease of molding to the required shape with light- weight, thin wall structure and with excellent fire protection.

  • PDF

The toxicity of Aceporol 460 as a novel high loading capacity solubilizer of paclitaxel

  • Kim, Yeo-Woon;Kim, Ja-Young;Cho, Min-Jung;Song, Hye-Weon;Lee, Min-Jae;Kim, Jong-Jae;Lee, Mi-Suk;Sheen, Yhun-Yhong
    • 한국환경독성학회:학술대회논문집
    • /
    • 한국환경독성학회 2002년도 추계국제학술대회
    • /
    • pp.172-172
    • /
    • 2002
  • Previously, we reported a novel polymeric micellar solubilizer, Aceporol 330, that showed relatively low toxic effects when it was compared with that of Cremophor EL which is currently being used for paclitaxel. In this study, we have developed a new micellar solubilizer, Aceporol 460, that has 3-4 times higher loding capacity for paclitaxel than Aceporol 330. The single-dose and the repeated-dose toxicity of Aceporol 460 were evaluated in ICR mice. For single dose toxicity test, male and female mice were randomly assigned to one of five study groups to receive, and injected intravenously with dosages of 0, 3, 4mL Cremophor EL/kgbody weight, and 3, 4mL Aceporol 460/kg body weight, respectively. In both male and female mice, LD50 for Aceporol 460 can not he determined even at the maximal administrable dosage, 4mL/kg due to the high viscosity of chemical and there was no significant change in body weight, hematological and serum biochemical analysis, organ weight, and histopathological examination compared with that of Cremophor EL. For the repeated dose toxicity test, male and female mice were given the dosage of 0, 1.6mL Cremophor EL/kgbody weight/day, and 1.6mL Aceporol 460/kg body weight/day for 2 weeks. Results of repeated dose toxicity tests for 2 weeks suggested that Aceporol 460 treated group show no significant toxicological findings with body weight, hematological and serum biochemical analysis, organ weight, urinalysis, and ophthalmoscopic and histopathological examination compared with that of Cremophor EL. These results indicate that Aceporol 460 have higher paclitaxeL-loading capacity than Aceporol 330 and less toxic effects than Cremophor EL in male and female mice.

  • PDF

갈륨 및 갈륨 합금을 이용한 저온접합 기술 동향 (Trends of Low-temperature Bonding Technologies using Gallium and Gallium Alloys)

  • 홍태영;심호률;손윤철
    • 마이크로전자및패키징학회지
    • /
    • 제29권2호
    • /
    • pp.11-18
    • /
    • 2022
  • 최근 세계적으로 유연 전자소자 관련 기술들이 주목을 받으면서 유연소자 제작 과정에서의 성형성 및 굽힘 상태에서의 성능과 내구성 등의 문제점을 개선하기 위하여 액체 금속을 사용한 배선·접합 기술들의 개발이 요구되고 있다. 이러한 요구에 부응하여 독성이 없으면서 낮은 점도와 우수한 전기전도도를 가지는 갈륨 및 갈륨계 합금 (공정 갈륨-인듐 및 공정 갈륨-인듐-주석 등)의 액체금속을 저온 접합소재로 이용하려는 다양한 연구들이 이루어지고 있다. 본 논문에서는 갈륨 및 갈륨계 합금을 이용한 저온접합 기술의 최신 연구동향을 정리하여 소개하고자 한다. 이러한 기술들은 향후 유연 전자소자의 제조 및 전자패키지에서의 저온접합 등의 분야에서 실용화를 위한 중요한 기반기술이 될 것으로 예상된다.

Methanol+Dimethyl Carbonate 혼합계의 333.15 K 등온 기-액 평형과 열역학 과잉 물성 (Isothermal Vapor-Liquid Equilibria at 333.15K and Thermodynamic Excess Properties for the Binary System of Methanol+Dimethyl Carbonate)

  • 한규진;박소진
    • Korean Chemical Engineering Research
    • /
    • 제43권3호
    • /
    • pp.387-392
    • /
    • 2005
  • Dimethyl carbonate(DMC)는 낮은 독성과 빠른 생분해성으로 인해 MTBE(methyl tert-butyl ether)를 대체할 수 있는 무연가솔린의 첨가제로 주목받는 물질로, 주로 methanol의 carbonylation에 의해 합성되고, 원가절감을 위해 methanol을 출발물질로 한 새로운 DMC 제조공정의 개발이 진행 중에 있다. 이에 필요한 다양한 조건하의 DMC 관련 혼합계의 상평형 자료 및 물성은 Dortmund Data Bank(DDB)검색 결과, 매우 부족하며 무한희석 활동도계수에 대한 자료는 전무한 것으로 나타났다. 이 글에서는 methanol+DMC계의 333.15 K에서의 이성분계 등온 기-액 평형과, 혼합물성으로써 methanol+DMC계의 과잉부피 및 점도편차를 298.15 K에서 측정하였다. 또한, 무한희석상태에서 DMC 용매에서의 methanol의 무한희석 활동도계수를 303.15, 313.15, 323.15 K에서 각각 측정하였으며, 측정값은 modified UNIFAC(Dortmund)식에 의한 계산 값과도 비교하였다.

삼백초, 뽕나무 줄기, 닥나무 줄기 등을 함유한 복합수목추출물의 화장품소재 특성 (Cosmetic Effect of Mixed Plant Extracts Including Saururus Chinensis, Morus Bombycis Stem and Morus Papyrifera Stem)

  • 정향리;김현우;김지혜;김진홍;김동욱
    • Korean Chemical Engineering Research
    • /
    • 제50권4호
    • /
    • pp.610-613
    • /
    • 2012
  • 본 연구에서는 삼백초 추출물 25%, 뽕나무 줄기추출물 20%, 닥나무 줄기추출물 20% 등을 함유한 복합수목추출물의 화장품소재로서의 이용가능성을 검토하였다. 소재 시험으로는 세포독성시험, 엘라스타제 억제효과시험, 티로시나제 억제효과시험, 항산화효과시험 및 온도 안정성시험이 실시되었다. 복합수목추출물은 세포독성이 낮았으며, 우수한 엘라스타제 억제효과와 항산화효과를 보여주었으나 티로시나제 억제효과는 다소 낮았다. 추출물을 함유한 스킨, 로션 및 에센스 제형을 제조하여 온도 안정성시험 결과 스킨과 에센스 제형은 우수한 안정성을 보여주었으나 로션은 상분리가 관찰되고, 점도의 변화가 심하여 제형의 변경이 필요한 것으로 나타났다. 따라서 삼백초 추출물, 뽕나무 추출물 및 닥나무 추출물을 함유한 복합수목추출물은 화장품소재로서 응용 가능성이 높음을 알 수 있었다.

식품첨가물의 독성자료 고찰과 ADI 평가지침 - 소포제 Polydimethylsiloxane를 사례로 - (Evaluation of Toxicological Data on Food Additives and Guideline for ADI establishment - Polydimethylsiloxane as emulsifier -)

  • 최찬웅;정지윤;박형수;문진현;이광호;이효민
    • 한국식품위생안전성학회지
    • /
    • 제24권4호
    • /
    • pp.352-356
    • /
    • 2009
  • 본 연구는 최근 JECFA에서 이슈화된 식품첨가물의 평가 정보를 파악하여 국내에서 선제적 위해관리에 활용할 수있도록 하기 위하여, 제 69차 JECFA 회의에 의제로 선정된 PDMS의 독성자료 검토 및 monograph 작성 내용에 대하여 소개하고자 수행되었다. PDMS의 독성자료 검토는 'Guidelines for the preparation of toxicological working papers for the Joint FAO/WHO Expert Committee on Food Additives'에 근거하였고, 평가 의뢰 시 제공된 자료 및 추가적으로 검색된 자료를 활용하였다. PDMS는 거품제거와 뭉침 방지를 위하여 간장, 제당, 당밀, 유제품, 쨈, 과즙제품, 두부 등의 제조 시 첨가물로 사용된다. 15,000-20,000 Da 이하의 분자량을 가지는 PDMS가 혈관을 통해 좀 더 쉽게 흡수될 수 있다는 문제가 제기되어, 기존에 설정된 ADI 0-1.5 mg/kg bw/day의 검토가 요구되었다. 이에 따라 흡수, 분포, 배설에 대한 자료와 독성시험자료의 검토가 수행되었다. 검토 결과 PDMS는 체내로 흡수가 거의 이루어지지 않고 대부분 배설되었으며, 급성독성, 아만성독성, 만성독성시험에서 특이적인 전신증상이 관찰되지 않았다. 그러나 급성독성, 아만성독성 및 만성독성시험에서 안구독성이 일관되게 관찰되었으며 이 안구독성의 기전이 확실하게 밝혀지지 않았다. 따라서 이전에 설정된 ADI 0-1.5mg/kg bw/day 값에 안구독성에 대한 추가적인 safety factor 2를 적용하여 temporary ADI 0-0.8 mg/kg bw/day로 재설정하였다. 또한 독성시험에서 관찰된 안구독성의 타당성을 설명하기 위한 추가적인 연구결과를 2010년까지 제공하도록 요청하였다.