• 제목/요약/키워드: low swing

검색결과 261건 처리시간 0.025초

만성 요천추부 신경근병증 환자의 보행분석 (Gait Analysis of the Chronic Lumbosacral Radiculopathic Patients)

  • 최병옥;유재응;정석
    • 한국전문물리치료학회지
    • /
    • 제11권3호
    • /
    • pp.19-24
    • /
    • 2004
  • The purposes of this study were to analyze gait patterns of patients with chronic lumboscaral radiculopathy and to investigate gait parameters which can reflect a functional deficit in relation to the level of lumbosacral radiculopathy. The study population consisted of 25 patients of chronic lumbosacral radiculopathy and 25 healthy control subjects. Conventional physical examinations and three-dimensional gait analyses were performed on all participants. The data were analyzed using an independent sample t-test. The results were as follows: (1) In the patients' group, cadence, walking velocity, stride length and double support time were less than in the control group (p<.05). (2) In the patients' group, maximum flexion of hip, maximum flexion of loading response, maximum flexion of swing phase on the knee and maximum plantar flexion of pre-swing were less than the control group (p<.05). Using three-dimensional gait analysis, we could identify specific gait parameters to reflect a functional deficit related to the level of lumbosacral radiculopathy.

  • PDF

편마비환자의 정적 골반경사각에 따른 보행 비대칭율의 차이에 대한 연구 (The study on difference of gait asymmetry ratio according to static pelvic inclination level in hemiplegic patient)

  • 김병조
    • The Journal of Korean Physical Therapy
    • /
    • 제18권3호
    • /
    • pp.1-7
    • /
    • 2006
  • Purpose: This study was performed to determine the difference or temporal-spatial gait asymmetry ratio according to static pelvic inclination level in hemiplegic patients. Methods: The subjects were 25 hemiplegic patients who was experienced stroke on MCA territory. Gait parameters and static pelvic inclination were recorded by $GAITRite^{(R)}$ system and radiologic PACS. The subjects were divided into three group according to static pelvic inclination. In the group I, the subjects have static pelvic inclination below $58^{\circ}$. The group II has $58^{\circ}{\sim}62^{\circ}$ or static pelvic inclination and the group m has over $62^{\circ}$ or static pelvic inclination. The data or three groups were analysed with ANOVA. Results: In comparison or single support time asymmetry ratio among 3 groups, the score or group II was significantly higher than the other groups(p<0.05). But the swing time asymmetry ratio was not significant(p>0.05). Conclusion: Asymmetry ratio of single support time was statistically significant by static pelvic inclination level. But asymmetry ratio or group II was the highest among three groups. It means that the patients or normal range of pelvic inclination was showed the most asymmetry or gait. And swing time asymmetry ratio was not significant among three groups. Even if the patient has normal ranged static pelvic inclination, it doesn't suggest that the patient has low gait asymmetry.

  • PDF

신발의 형태가 노인의 보행에 미치는 영향 (The Effect of Footwear on Gait in Older Adults)

  • 이윤경;배성수;한진태
    • 대한물리의학회지
    • /
    • 제2권2호
    • /
    • pp.161-171
    • /
    • 2007
  • Purpose : The purpose of this study was to evaluate the effect of footwear on gait in older adults. Methods : The footwear consists of loafer with fixation and mule and slipper without fixation. Twenty one female older adults voluntarily participated in this study. Each participant walked on the gait system GAITRite and measured temporal-spatial gait parameters. And the participants wore loafer, mule, slipper randomly. We measured stance time, swing time, heel-to-heel BOS, double support time, velocity, cadence, FAP as temporal-spatial gait parameters. Results : Three gait parameters showed significant difference statistically among 7 gait parameters. The stance time increased as loafer, mule, barefoot, slipper orderly. And there was a significant difference statistically (p<.05). The swing time increased as slipper, barefoot, mule, loafer orderly. And there was a significant difference statistically(p<.05). And the heel-to-heel BOS increased as barefoot, loafer, mule, slipper orderly. And there was a significant difference statistically(p<.05) according to footwear type. Conclusion : The footwear type with high stability like loafer is considered better than footwear type with low stability like mule and slipper for the elderly.

  • PDF

바이오 센서 적용을 위한 수직형 이중게이트 InGaAs TFET의 게이트 열화 현상 분석 (Constant Voltage Stress (CVS) and Hot Carrier Injection (HCI) Degradations of Vertical Double-date InGaAs TFETs for Bio Sensor Applications)

  • 백지민;김대현
    • 센서학회지
    • /
    • 제31권1호
    • /
    • pp.41-44
    • /
    • 2022
  • In this study, we have fabricated and characterized vertical double-gate (DG) InGaAs tunnel field-effect-transistors (TFETs) with Al2O3/HfO2 = 1/5 nm bi-layer gate dielectric by employing a top-down approach. The device exhibited excellent characteristics including a minimum subthreshold swing of 60 mV/decade, a maximum transconductance of 141 µS/㎛, and an on/off current ratio of over 103 at 20℃. Although the TFETs were fabricated using a dry etch-based top-down approach, the values of DIBL and hysteresis were as low as 40 mV/V and below 10 mV, respectively. By evaluating the effects of constant voltage and hot carrier injection stress on the vertical DG InGaAs TFET, we have identified the dominant charge trapping mechanism in TFETs.

Burnable Absorber Design Study for a Passively-Cooled Molten Salt Fast Reactor

  • Nariratri Nur Aufanni;Eunhyug Lee;Taesuk Oh;Yonghee Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.900-906
    • /
    • 2024
  • The Passively-Cooled Molten Salt Fast Reactor (PMFR) is one of the advanced design concepts of the Molten Salt Fast Reactor (MSFR) which utilizes a natural circulation for the primary loop and aims to attain a long-life operation without any means of fuel reprocessing. For an extended operation period, it is necessary to have enough fissile material, i.e., high excess reactivity, at the onset of operation. Since the PMFR is based on a fast neutron spectrum, direct implementation of a burnable absorber concept for the control of excess reactivity would be ineffective. Therefore, a localized moderator concept that encircles the active core has been envisioned for the PMFR which enables the effective utilization of a burnable absorber to achieve low reactivity swing and long-life operation. The modified PMFR design that incorporates a moderator and burnable absorber is presented, where depletion calculation is performed to estimate the reactor lifetime and reactivity swing to assess the feasibility of the proposed design. All the presented neutronic analysis has been conducted based on the Monte Carlo Serpent2 code with ENDF/B-VII.1 library.

Low-operating voltage Pentacene FETs with High dielectric constant polymeric gate dielectrics and its hyteresis behavior

  • Park, Chan-Eon
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.168-168
    • /
    • 2006
  • Low-operating voltage organic field-effect transistors (OFETs) have been realized with high dielectric constant (${\kappa}$) polymer such as cyanoethylated poly vinyl alcohol (CR-V, ${\kappa}=12$). Since the $high-{\kappa}$polymers are likely to contain water and ionic impurities, large hysteresis and considerable leakage current are frequently observed in OFETs. To solve these problems, we cross-linked the CR-V by using a cross-linking agent. Cross-linked CR-V dielectrics showed high dielectric constant of 11.1 and good insulating properties, resulting in a high capacitance ($81nF/cm^{2}$ at 1MHz) at 120 nm of dielectric thickness. Pentacene FETs with cross-linked CR-V dielectrics exhibited high carrier mobility ($0.72\;cm^{2}/Vs$), small subthreshold swing (185 mV/dec) and little hysteresis at low-operating voltage (${\Leq}-3V$).

  • PDF

A 6 Gbps/pin Low-Power Half-Duplex Active Cross-Coupled LVDS Transceiver with Switched Termination

  • Kim, Su-A;Kong, Bai-Sun;Lee, Chil-Gee;Kim, Chang-Hyun;Jun, Young-Hyun
    • ETRI Journal
    • /
    • 제30권4호
    • /
    • pp.612-614
    • /
    • 2008
  • A novel linear switched termination active cross-coupled low-voltage differential signaling (LVDS) transceiver operating at 1.5 GHz clock frequency is presented. On the transmitter side, an active cross-coupled linear output driver and a switched termination scheme are applied to achieve high speed with low current. On the receiver side, a shared pre-amplifier scheme is employed to reduce power consumption. The proposed LVDS transceiver implemented in an 80 nm CMOS process is successfully demonstrated to provide a data rate of 6 Gbps/pin, an output data window of 147 ps peak-to-peak, and a data swing of 196 mV. The power consumption is measured to be 4.2 mW/pin at 1.2 V.

  • PDF

만성요통환자의 보행특성에 관한 연구 (A Study on the Characteristics of Gait in Patients with Chronic Low Back Pain)

  • 김경;고주연;이성용
    • The Journal of Korean Physical Therapy
    • /
    • 제21권2호
    • /
    • pp.79-85
    • /
    • 2009
  • Purpose: This study examined the characteristics of gait in patients with chronic low back pain. Methods: The subjects were out-patients suffering from chronic low back pain at the department of physical therapy, B hospital in Seoul. Gait analysis was performed by dividing the subjects into two groups. The study and control group comprised 15 chronic low back pain patients and 14 healthy people, respectively. Gait analysis was performed using a VICON 512 Motion Analysis System to obtain the spatio-temporal and kinematic parameters. Results: First, there was a significant difference in the spatio-temporal parameters between the two groups (p<0.05). Second, the study group showed significant differences in the kinematic parameters during the stance phase (p<0.05). Third, there were significant differences in kinematic parameters in the study group during the swing phase (p<0.05). Conclusion: The gait pattern of patients with chronic low back pain is characterized by more rigid patterns. Compared to the control group, there was a decrease in the spatio-temporal parameters and kinematic parameters in patients with chronic low back pain. These findings are expected to play a role as basic data and to form a rehabilitation program for low back pain patients.

  • PDF

PSA법을 이용하여 $CH_4/CO_2/N_2$ 혼합가스 중에서 메탄의 분리 (Separation of $CH_4/CO_2/N_2$ Mixture by Pressure Swing Adsorption)

  • 조우람;정구현;신영환;유희찬;나병기
    • 청정기술
    • /
    • 제17권4호
    • /
    • pp.389-394
    • /
    • 2011
  • 바이오가스로부터 이산화탄소와 질소를 제거하기 위한 흡착공정은 많이 논의되고 있다. 특히 흡착공정 중에서 압력변동흡착(Pressure swing adsorption)공정은 에너지소모가 적고 가격이 경제적이기 때문에 기체의 분리와 정제를 위한 공정으로 적절하다. 물리적 흡착을 사용하는 PSA공정은 흡착과 탈착이 가능하다. 각 cycle단계의 구성은 가압, 주입 및 흡착, 압력 균등화, 감압 및 세정으로 이루어져있다. 본 실험에서 PSA공정은 이산화탄소와 질소를 제거하기 위한 흡착제로 zeolite 13X와 carbon molecular sieve (CMS)로 구성되어 있으며, 혼합 가스의 농도는 $CH_4/CO_2/N_2$ (75:21:4 vol%)의 비율을 갖고 있다. 각각 zeolite 13X와 CMS는 선택적으로 혼합가스로부터 질소와 이산화탄소를 흡착하여 분리하고 제거한다. 또한 CMS의 경우는 빠르게 분산되는 이산화탄소의 처리량이 높다. 상부탱크, 하부탱크, 주입탱크의 가스 조성은 TCD 검출기를 이용하는 gas chromatography (GC)에 의해서 측정되었다.

압력순환흡착법과 다공성 매체 연소법을 이용한 전자산업 불화가스 저감 스크러버 개발 (The Development of Scrubber for F-gas Reduction from Electronic Industry Using Pressure Swing Adsorption Method and Porous Media Combustion Method)

  • 정종국;이기용;이상곤;이은미;모선희;이대근;김승곤
    • 청정기술
    • /
    • 제23권2호
    • /
    • pp.181-187
    • /
    • 2017
  • 반도체 및 디스플레이 산업에서 배출되는 과불화합물은 연소, 열, 플라즈마, 촉매 등의 다양한 방법이 적용된 스크러버에 의해 분해 과정을 거친 후 배출되나, 운영 스크러버의 대부분이 과도한 에너지의 사용, 낮은 저감 효율을 보임으로써 이러한 단점의 극복이 요구된다. 압력순환흡착법과 다공성 매체 연소법의 두 가지 기술이 연계된 새로운 형태의 과불화합물 저감 스크러버를 개발하고 특성을 알아보았다. 분해 대상인 $CF_4$의 흡착비와 손실계수는 흡착 컬럼의 입구와 출구에서 농도 측정을 통해 계산하였으며, 연소기의 입구와 출구의 유량과 농도 측정을 통해 처리 효율을 계산하였다. 기존 스크러버와의 에너지 사용량 및 처리효율 비교를 위하여 다양한 유량에 대한 성능 평가가 진행되었다. 1412 ppm, 204 LPM의 $CF_4$가 유입된 흡착 컬럼에서의 흡착비는 1.65였으며, 유입되는 $CF_4$의 손실 계수는 8.2%였다. 이때 연소기로 유입되는 $CF_4$의 유량과 농도는 각각 91 LPM과 2335 ppm이었으며, $CF_4$ 19 LPM, $O_2$ 40 LPM을 사용한 연소 반응시 약 96%의 저감 효율을 나타내었다. 상용 스크러버와의 동일 운전 조건에서의 다공성 매체 연소에서의 $CF_4$ 저감 효율과 전체 에너지 사용 효율 비교시 각각 16%, 41% 이상의 저감 효율 상승과 에너지 절감 효과를 보였다.