• Title/Summary/Keyword: low profile

Search Result 1,611, Processing Time 0.039 seconds

The Calculation of the Amount of Wear using Digital Filtering (디지털 필터링을 이용한 마멸량 계산)

  • 전종하;구영필;조용주
    • Tribology and Lubricants
    • /
    • v.16 no.2
    • /
    • pp.133-137
    • /
    • 2000
  • A new method to calculate the wear amount using surface profile signal was suggested. It takes advantage of filtering technic to estimate the original surface profile of wear track precisely. The original profile of wear track was estimated by comparing with outside of wear track. The estimated surface profile was well fitted to the original profile assumed unknown.

The Calculation of the amount of wear using digital filtering (디지털 필터링을 이용한 마멸량 계산)

  • 전종하;유응대;구영필;조용주
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.200-207
    • /
    • 1999
  • A new method for the calculation of a wear amount was suggested. The amount of wear was calculated by the comparison of worn out profile with an estimated original profile. An original profile of wear track was estimated by comparing with outside of wear track. An estimated surface profile was well fitted to the original profile assumed unknown.

  • PDF

The Results of the First Ray Forefoot Osteotomy Using Low Profile Wedge Plate without a Bone Grafting for Pes Planus Correction (제 1열 전족부 절골술을 통한 평발 교정에 있어 골이식 없이 사용한 소형 쐐기형 금속판의 치료 결과)

  • Choi, Jun Young;Shin, Myung Jin;Suh, Jin Soo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.1
    • /
    • pp.7-11
    • /
    • 2017
  • Purpose: We retrospectively analyzed the radiographic and clinical results after the first ray of forefoot osteotomy using low profile wedge plate without additional cancellous bone grafting for pes planus correction. Materials and Methods: Twenty-four patients were enrolled in this study. Medial cuneiform opening wedge osteotomy was performed in 12 patients (Cotton osteotomy, group C) and first metatarsal base osteotomy was performed in 12 patients (group MT). Results: On average, the wedge size was 5.61 mm (5~6 mm). The mean time to radiographic union was 3.18 and 3.27 months in groups C and MT, respectively. Postoperative talonavicular coverage angle, talo-first metatarsal angle (anteroposterior), talo-first metatarsal angle (lateral), talo-calcaneal angle (lateral), medial cuneiform height, and American orthopaedic foot, as well as ankle society midfoot scale were significantly improved in both groups. Nonunion, delayed union or fixation failure was not presented in our series. Conclusion: We have shown that low profile wedge plate was effective in the case of first ray forefoot osteotomy for pes planus correction without any additional cancellous bone grafting.

Low Profile Dual Feeding Microstrip Antenna with High Isolation (높은 격리도를 갖는 Low Profile 이중급전 마이크로스트립 안테나)

  • 김형락;권종훈;윤영중;윤재승;전순익
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.7
    • /
    • pp.709-715
    • /
    • 2002
  • In this paper, a novel low profile dual feeding microstrip antennas with microstrip and H-shaped aperture feeding are proposed to achieve high isolation and easy feeding, and the validity of the proposed antennas is demonstrated experimentally. In the proposed single and 1$\times$4 array antenna, the measured isolations are less than -49 dB and -48 dB, impedance bandwidths are 4 % at 12.5 GHz and 2.1 % at 14.25 GHz for the VSWR<1.5 in both antennas and maximum gains are 8.25 dBi and 14.2 dBi.

Motion Control Algorithm Expanding Arithmetic Operation for Low-Cost Microprocessor (저가형 마이크로프로세서를 위한 연산처리 확장 모션제어 알고리즘)

  • Moon, Sang-Chan;Kim, Jae-Jun;Nam, Kyu-Min;Kim, Byoung-Soo;Lee, Soon-Geul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.12
    • /
    • pp.1079-1085
    • /
    • 2012
  • For precise motion control, S-curve velocity profile is generally used but it has disadvantage of relatively long calculation time for floating-point arithmetics. In this paper, we present a new generating method for velocity profile to reduce delay time of profile generation so that it overcomes such disadvantage and enhances the efficiency of precise motion control. In this approach, the velocity profile is designed based on the gamma correction expression that is generally used in image processing to obtain a smoother movement without any critical jerk. The proposed velocity profile is designed to support both T-curve and S-curve velocity profile. It can generate precise profile by adding an offset to the velocity profile with decimals under floating point that are not counted during gamma correction arithmetic operation. As a result, the operation time is saved and the efficiency is improved. The proposed method is compared with the existing method that generates velocity profile using ring buffer on a 8-bit low-cost MCU. The result shows that the proposed method has no delay in generating driving profile with good accuracy of each cycle velocity. The significance of the proposed method lies in reduction of the operation time without degrading the motion accuracy. Generated driving signal also shows to verify effectiveness of the proposed method.

Durability of the Low Profile Ionescu-Shiley Valve in the Mitral Position (이오네스큐 단고형 승모판의 내구성)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.25 no.8
    • /
    • pp.863-870
    • /
    • 1992
  • The low profile Ionescu-Shiley pericardial xenograft valve had been initially introduced to have improved hemodynamic performance and expected superior durability, However, subsequent clinical reports and laboratory studies have repeatedly indicated early failure of the valve from mechanical reasons in valve design, A total and consecutive 169 patients underwent isolated MVR with the low profile Ionescu-Shiley valve at Seoul National University Hospital from November 1984 to October 1989 [Group ISLM]. Five patients [3.0%] died within 30 days of surgery, and early survivors were followed up for 734.9 patient-years [Mean$\pm$SD, 4.9$\pm$2.0 years], Late mortality rate was 0.136% /patient-year [pt-yr], Linearized incidences of major complications were: 0.953% embolism /pt-yr; 0.680% bleeding /pt-yr; 0.272% endocarditis /pt-yr; and 0, 408% primary tissue failure [PTF] /pt-yr, The actuarial survival was 99.4$\pm$0.6%, and probabilities of from thromboembolism and from PTF were 90.7$\pm$4.6% and 95.9$\pm$2.6% at 8 years, respectively These results were compared with the clinical data from the 291 patients of isolated MVR with the standard Ionescu-Shiley valve at the same hospital during the period between October 1978 and June 1983 [Group ISUM], Group ISUM included 11% of patients younger than 15 years of age, whereas Group ISLM did no patient of this age. The mean age at the time of surgery was significantly younger in Group ISUM than one in Group ISLM [P<0.001]. Differences were not statistically significant in operative mortality, mean follow-up period and linearized incidences of thromboembolism, bleeding and endocarditis, between two groups, However, the linearized rate of PTF was lower [P<0.001] and probabilities of freedom fro PTF higher [P<0.001] in Group ISLM at least up to postoperative 8 years. While the features of PTF of the standard valve was predominantly degeneration with calcification and stenosis, the ones of the low profile valve was cusp tear and incompetence. It remains, however, to be seen whether the low profile valve fails mostly from mechanical reason, and further follow-up will still be necessary to determine the differences in mode of PTF of two valves.

  • PDF

Design of a Modified Alford Loop Antenna for On-Body Devices (인체 부착형 기기를 고려한 변형된 Alford 루프 안테나 설계)

  • Park, Joongki;Lee, Juneseok;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.1
    • /
    • pp.25-31
    • /
    • 2014
  • In this paper, a modified Alford loop antenna for on-body communication system is proposed. The proposed antenna operating in the ISM band is designed with consideration of human body effect. One of advantages of the Alford loop antenna structure is low-profile, however the Alford loop antenna is not suitable for on-body devices since it does not have a ground plane for other electronic part of on-body system and requires balanced feeding structure. To be embedded on on-body devices, the proposed antenna is design with the unbalanced feed structure and ground. The performance of the proposed antenna is simulated and measured when it is placed on the human body phantom to consider the effect of the human body. The proposed antenna a 10 dB return loss bandwidth over the ISM band and monopole-like radiation pattern with low-profile. The antenna has the surface of appropriate for on-body communication environment.

Effect of the Low Profile Agent and Release Agent on the Surface Morphology and Property of Bulk Mold Compound (저수축제 및 이형제가 벌크몰드컴파운드의 표면형태 및 물성에 미치는 영향)

  • Kim, Sung-Ryong;Kwon, Ki-Joon
    • Journal of Adhesion and Interface
    • /
    • v.12 no.4
    • /
    • pp.144-150
    • /
    • 2011
  • The effect of low profile agent and release agent on the surface and mechanical properties of bulk mold compound were investigated. Atomic content and contact angle of surface were characterized using X-ray photoelectron spectroscopy and contact anglemeter. Surface morphology and surface roughness were obtained using field emission scanning electron microscope and atomic force microscope, respectively. As increasing the low profile agent from 0 to 9.2 wt%, the volume shrinkage and surface roughness decreased from 0.35% to 0.05%, and from $0.27{\mu}m$ to $0.12{\mu}m$, respectively. The increase of release agent from 1.8 wt% to 3.6 wt% resulted in the migration of release agent to sample surface and it increased the surface roughness. The flexural strength and impact strength were decreased approximately 30% as the low profile agent increasing from 5.0 wt% to 9.0 wt%.