• Title/Summary/Keyword: low point

Search Result 5,332, Processing Time 0.037 seconds

Novel Maskless Bumping for 3D Integration

  • Choi, Kwang-Seong;Sung, Ki-Jun;Lim, Byeong-Ok;Bae, Hyun-Cheol;Jung, Sung-Hae;Moon, Jong-Tae;Eom, Yong-Sung
    • ETRI Journal
    • /
    • v.32 no.2
    • /
    • pp.342-344
    • /
    • 2010
  • A novel, maskless, low-volume bumping material, called solder bump maker, which is composed of a resin and low-melting-point solder powder, has been developed. The resin features no distinct chemical reactions preventing the rheological coalescence of the solder, a deoxidation of the oxide layer on the solder powder for wetting on the pad at the solder melting point, and no major weight loss caused by out-gassing. With these characteristics, the solder was successfully wetted onto a metal pad and formed a uniform solder bump array with pitches of 120 ${\mu}m$ and 150 ${\mu}m$.

An Image Contrast Enhancement Technique Using Integrated Adaptive Fuzzy Clustering Model (IAFC 모델을 이용한 영상 대비 향상 기법)

  • 이금분;김용수
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2001.12a
    • /
    • pp.279-282
    • /
    • 2001
  • This paper presents an image contrast enhancement technique for improving the low contrast images using the improved IAFC(Integrated Adaptive Fuzzy Clustering) Model. The low pictorial information of a low contrast image is due to the vagueness or fuzziness of the multivalued levels of brightness rather than randomness. Fuzzy image processing has three main stages, namely, image fuzzification, modification of membership values, and image defuzzification. Using a new model of automatic crossover point selection, optimal crossover point is selected automatically. The problem of crossover point selection can be considered as the two-category classification problem. The improved MEC can classify the image into two classes with unsupervised teaming rule. The proposed method is applied to some experimental images with 256 gray levels and the results are compared with those of the histogram equalization technique. We utilized the index of fuzziness as a measure of image quality. The results show that the proposed method is better than the histogram equalization technique.

  • PDF

A Fuzzy Image Contrast Enhancement Technique using the K-means Algorithm (K-means 알고리듬을 이용한 퍼지 영상 대비 강화 기법)

  • 정준희;김용수
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2002.12a
    • /
    • pp.295-299
    • /
    • 2002
  • This paper presents an image contrast enhancement technique for improving low contrast images. We applied fuzzy logic to develop an image contrast enhancement technique in the viewpoint of considering that the low pictorial information of a low contrast image is due to the vaguness or fuzziness of the multivalued levels of brightness rather than randomness. The fuzzy image contrast enhancement technique consists of three main stages, namely, image fuzzification, modification of membership values, and image defuzzification. In the stage of image fuzzification, we need to select a crossover point. To select the crossover point automatically the K-means algorithm is used. The problem of crossover point selection can be considered as the two-category, object and background, classification problem. The proposed method is applied to an experimental image with 256 gray levels and the result of the proposed method is compared with that of the histogram equalization technique. We used the index of fuzziness as a measure of image quality. The result shows that the proposed method is better than the histogram equalization technique.

A Study on the Importance and Performance of the Display of Dining Space for Hotel Banquets (호텔 연회 식공간 연출에 대한 중요도와 만족도 분석 연구)

  • Kim, Gi-Chul;Lee, Yeon-Jung
    • Culinary science and hospitality research
    • /
    • v.15 no.2
    • /
    • pp.173-187
    • /
    • 2009
  • The purpose of this study is to provide useful information for establishing efficient marketing direction by investigating the performance(satisfaction) and importance of the display of dining space for hotel banquets. The importance and satisfaction scores of the display of dining space were measured on the five-point Likert scale. The results were summarized as follows. 'Taste of food(4.53 point)', 'freshness of food materials(4.50 point)', and 'indoor cleanliness(4.38 point)' were considered highly important while 'carpet shape of the floor(3.68 point)' and 'art objects(3.69 point)' were scored low. As for the factors of satisfaction, 'freshness of food materials(3.86 point)', 'taste of food(3.85 point)', 'indoor cleanliness(3.74 point)', and 'overall cleanliness of tables(3.73 point)' were considered highly satisfactory while 'art objects(3.42 point)', 'item decoration(3.44 point)', 'furniture and accessory decoration(3.45 point)' were scored low. As a result of analyzing difference between importance and performance of the display of dining space, importance(4.02 point) was much higher than performance(3.60 point). For the IPA result, customers made much account of 'taste of food', 'freshness of food materials', 'indoor cleanliness', 'overall cleanliness of tables', 'cleanliness state of a banquet hall' and so on, so they were regarded as the items to be continuously cared for. Also, intensive care was needed in such factors as 'indoor temperature', 'food vessels', 'soundproofing' and 'colors of a banquet hall' due to low customer satisfaction.

  • PDF

A Randomized Controlled Trial to Verify Effects of Kuesu Point on Low Back Pain and Accompanied Sciatica

  • Lee, Jeong-Won;Kim, Dong-Il
    • The Journal of Korean Medicine
    • /
    • v.28 no.4
    • /
    • pp.86-94
    • /
    • 2007
  • Objective : Kuesu point is a newly discovered point, it is located in 3-cun from the centre of sacrum laterally, paralleled to the 4th foramen on the sacrum. This controlled trial was to evaluate the superior effect of Kuesu point on back pain which radiated to lower extremities. Methods : Randomized Controlled Trial (RCT) and Single Blind in patient was designed. Patients (n=31) were randomized to two groups, Kuesu-point acupuncture group (Group A, n=16) and non Kuesu point acupuncture group (Group B, n=15). Group A was acupunctured on B25 (大腸兪), B26 (關元兪) and B60 (崑崙) with Kuesu point. Group B was acupunctured on the same points without Kuesu point. The clinical subjects were female patients. Beside acupuncture, the other therapies were excluded. Clinical period was three weeks total. Each group was treated 4-5 times per week for 3 weeks. The outcome measurements were The Estimation Index of Backache (quality of life), Pain Rating Scale (pain intensity) and other physical examinations (ROM, SLR, etc.). Results : 31 patients (Group A: n=16, Group B: n=15) were Randomized, 6 of them dropped out. Eventually 25 patients (Group A: n=15, Group B: n=10) were included in the analysis. Group A acupunctured on Kuesu point scored more significant Estimation Index of Backache and lower PRS (Pain Rating Scale) than Group B acupunctured without Kuesu point (p=0.003/2). It turned out that the group acupunctured on Kuesu point show meaningful high improvement index. And other examination's results showed that the treatment effects of Group A are twice as better as Group B. Conclusion : These results suggest that Kuesu point acupuncture was more effective on lower back pain and improved the life quality of patients, being compared with non Kuesu point acupuncture.

  • PDF

Development of Titanium-based Brazing Filler Metals with Low-melting-point

  • Onzawa, T.;Iiyama, T.
    • International Journal of Korean Welding Society
    • /
    • v.2 no.2
    • /
    • pp.14-18
    • /
    • 2002
  • Titanium and titanium alloy are excellent in corrosion resistance and specific intensity, and also in the biocompatibility. On the other hand, the brazing is bonding method of which productivity and reliability are high, when the complicated and precise structure of the thin plate is constructed. However, though conventional titanium-based brazing filler metal was excellent in bond strength and corrosion resistance, it was disadvantageous that metal structure and mechanical property of the base metal deteriorated, since the brazing temperature ( about $1000^{\circ}C$ ) is considerably high. Authors developed new brazing filler metal which added Zr to Ti-Cu (-Ni) alloy which can be brazed at $900^{\circ}C$ or less about 15 years ago. In this paper, the development of more low-melting-point brazing filler metal was tried by the addition of the fourth elements such as Ni, Co, Cr for the Ti-Zr-Cu alloy. As a method for finding the low-melting-point composition, eutectic composition exploration method was used in order to reduce the experiment point. As the result, several kinds of new brazing filler metal such as 37.5Ti-37.5-Zr-25Cu alloy (melting point: $825^{\circ}C$) and 30Ti-43Zr-25Cu-2Cr alloy (melting point: $825^{\circ}C$) was developed. Then, the brazing joint showed the characteristics which were almost equal to the base metal from the result of obtaining metallic structure and strength of joint of brazing joint. However, the brazing filler metal composition of the melting point of $820^{\circ}C$ or less could not be found. Consequentially, it was clarified that the brazing filler metal developed in this study could be practically sufficiently used from results such as metal structure of brazing joint and tensile test of the joint.

  • PDF

Algebraic Accuracy Verification for Division-by-Convergence based 24-bit Floating-point Divider Complying with OpenGL (Division-by-Convergence 방식을 사용하는 24-비트 부동소수점 제산기에 대한 OpenGL 정확도의 대수적 검증)

  • Yoo, Sehoon;Lee, Jungwoo;Kim, Kichul
    • Journal of IKEEE
    • /
    • v.17 no.3
    • /
    • pp.346-351
    • /
    • 2013
  • Low-cost and low-power are important requirements in mobile systems. Thus, when a floating-point arithmetic unit is needed, 24-bit floating-point format can be more useful than 32-bit floating-point format. However, a 24-bit floating-point arithmetic unit can be risky because it usually has lower accuracy than a 32-bit floating-point arithmetic unit. Consecutive floating-point operations are performed in 3D graphic processors. In this case, the verification of the floating-point operation accuracy is important. Among 3D graphic arithmetic operations, the floating-point division is one of the most difficult operations to satisfy the accuracy of $10^{-5}$ which is the required accuracy in OpenGL ES 3.0. No 24-bit floating-point divider, whose accuracy is algebraically verified, has been reported. In this paper, a 24-bit floating-point divider is analyzed and it is algebraically verified that its accuracy satisfies the OpenGL requirement.

EFFECT OF VARIOUS MECHANICAL TREATMENTS ON TITANIUM PLASMA SPRAYED IMPLANT SURFACES (Titanium plasma sprayed implant에 관한 여러가지 기계적 표면처리방법이 implant표면조도에 미치는 영향)

  • Yu, Hyeon-Seok;Park, Jae-Wan;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.493-506
    • /
    • 1993
  • For maintenance of an ailing or failed implant it is essential to treat the implant fixture surface so as to remove bacterial endotoxin and make a surface tolerated by surrounding soft and hard tissue. Thus in this study the method that makes the smoothest surface treated with a high speed diamond bur, a low speed diamond bur, a stone, a rubber point or Jetpolisher was studied. With the profilomenter a mean value of $R_{max}$ was measured. The hight speed diamond, the rubber point and the Jetpolisher showed a mean $R_{max}\;7.77{\mu}m$. The low speed diamond bur, the rubber, point and the Jetolisher made a mean value of $R_{max}\;8.44{\mu}m$. The stone, the rubber point and the Jetolisher showed the smoothest surfaces with a mean value of $R_{max}\;6.24{\mu}m$. TPS (titanium plasma sprayed) areas showed a mean vlaue of $R_{max}\;24.42{\mu}m$, and the smooth surfaced titanium disc manufactured by the company (IMZ, Germany) shows a mean value of $R_{max}\;3.00{\mu}m$. Under the SEM examination the disc treated with a high speed diamond bur, a rubber point and a Jetpolisher showed partially remaining TPS particles, but the height of these particles were reduced remarkably compared with those of the original TPS. The disc treated with a low speed diamond bur, a rubber point and a Jetpolisher showed a rough topography with remaining TPS on the entire surface. A stone, a rubber point and a Jetpolisher removed almost TPS and the bulk titanium metal was exposed and some scratches were made by the stone. All treated discs were revealed as rougher than the smooth surface disc manufactured by the company. An untreated TPS disc shows a very irregular surface and a $40{\mu}m$ height of the plasma sprayed areas.

  • PDF

The Immediate Effects of 975-nm GaAlAs Low-level Laser Therapy on Myofacial Triger Point of Upper Trapezius Muscle in Subjects with Rounded Shoulder Posture (둥근 어깨 자세를 가진 자의 등세모근 위 섬유의 압통점에 975-nm GaAlAs 저출력레이저 적용에 대한 즉각적인 효과)

  • Kim, Byeong-Jo;Lee, Jung-Hoon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.4
    • /
    • pp.433-438
    • /
    • 2014
  • PURPOSE: The purpose of our study was to compare a 975-nm, 500-mW GaAlAs low-level laser therapy versus placebo low-level laser therapy with regard to the immediate changes on the myofascial trigger point of the dominant upper trapezius muscle in subjects with rounded shoulder posture. METHODS: Thirty-two male college students with rounded shoulder posture and shoulder pain consented to participate in the experiment. The subjects were randomly assigned to a 2-minute procedure with either an active GaAlAs low-level laser or a placebo GaAlAs low-level laser. The pressure-pain threshold and visual analog scale on tenderness at 3 kg were measured with an algometer before and after the laser treatments. RESULTS: The active GaAlAs low-level laser group showed significant changes in pressure-pain threshold and visual analog scale on tenderness at 3 kg (p<0.05). The placebo GaAlAs low-level laser group showed no significant changes in either pressure-pain threshold or visual analog scale on tenderness at 3 kg (p>0.05). CONCLUSION: An immediate effect was observed in pressure-pain threshold and visual analog scale on tenderness at 3 kg following a 2-minute application ($857.14J/cm^2$) of a 975-nm, 500-mW GaAlAs low-level laser to the myofascial trigger point of the dominant upper trapezius muscle in patients with rounded shoulder posture.

Effect of n-Alkylamine Hydrochlorides on the Cloud Point of Nonionic Polyoxyethylated Surfactant

  • Han, Suk-Kyu;Kim, Young-Mi
    • YAKHAK HOEJI
    • /
    • v.20 no.3
    • /
    • pp.156-161
    • /
    • 1976
  • The salting in and salting out of Octoxynol, N.F., a nonionic polyoxyethylated surfactant by n-alkylamine hydrochlorides ws investigated by measuring their effect on the cloud point of the surfactant at various salt concentrations. The carbon number of the alkyl chain was varied from zero to twelve. Ammonium chloride, methylamine hydrochloride and ethylamine hydrochloride tended to salt out the surfactant, lowering its cloud point in proportion to the salt concentration. n-Ankylamine and n-butylamine hydrochlorides showed salting-out effect at low concentrations of the electrolyte, while their effects were leveled off and showed rather salting-in trend at higher concentrations of the electrolyte. These salting-in effect was ascribed to the formation of a hydrotropy of the n-alky lammonium cations with the surfactant. The higher homolog compounds of n-alkylamine hydrochlorides showed extraordinarily high salting-in effect at very low oncentrations of the electrolyte. These large salting-in effects were more drastic as the chain length was getting longer. These large increases of the cloud point of the surfactant were attributed to the formation of mixed micelles of n-alkylammonium cations with the polyoxyethylated surfactant.

  • PDF