• 제목/요약/키워드: low load

Search Result 3,904, Processing Time 0.037 seconds

A Inertia Load Test using a Low Frequency Synchronous PWM Technique of high efficiency for Electric car. (전동차용 고효율 저주파 동기 PWM을 이용한 관성부하 시험)

  • 이광주;정만규;고영철;장성영;방이석
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.233-240
    • /
    • 1998
  • This paper presents a high efficiency low switching PWM technique for the propulsion system of Electric car. In order to achieve the continuous voltage control to six-step and a low harmonics with low switching frequency under 500㎐, the synchronous technique is combined with a space vector overmodulation and implemented by using DSP. Improved performance and a validation of proposed method is shown by the experimental results using a 1.65MVA IGBT VVVF inverter and inertia load equivalent to 160 tons electric cars.

  • PDF

Strategical Postures for Relieving EMG Amplitude Discrepancy on Bilateral Low Back Muscles and Total Low Back Muscle Fatigue while Lifting Asymmetric Load Dynamically (비대칭무게중심 물체의 동적 들기 작업시 좌.우 허리 근육의 EMG 진폭차이와 피로를 줄이기 위한 자세 연구)

  • Kim, Sun-Uk;Han, Seung-Jo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.3
    • /
    • pp.103-109
    • /
    • 2012
  • The purpose of this paper is to suggest the strategical lifting postures able to alleviate imbalanced EMG amplitude leading to an increase in low back muscle fatigue while lifting asymmetric load dynamically. Eleven male subjects are required to lift symmetrically an external load with 15.8kg and load center of gravity (LCG) deviated 10cm to the right from the floor to the waist height at the speed of about 25cm/sec. The EMG amplitudes on bilateral low back muscles (Longissimus, Iliocostalis, and Multifidus) are recorded during 2sec and analyzed. Independent variables are trunk postures (No bending vs. Bending to the LCG) and feet placements (Parallel vs. Right foot in front of the other vs. Right foot behind the other). Dependent variables are EMG amplitude average on six muscles and the EMG amplitude difference between right and left muscle group. Results indicate the phenomenon showing an amplitude increase in the left muscle group is equal to an decrease in the right one is observed in dynamic as well as static lifts, bending the trunk to the LCG increases amplitude discrepancy more than no trunk bending, and the amplitude discrepancy in one foot ipsilateral to LCG in front of the other foot is lowest among other foot postures. As bilateral EMG amplitude discrepancy increases total low back muscle fatigue, the strategical combination of no trunk bending and one foot close to LCG in front of the other is recommended for preventing elevated incidence of low back pain (LBP).

Study on Low Temperature Environmental Characteristics of Sandwich Core Made with 3D Printer (3D 프린터로 제작한 샌드위치 코어의 저온 환경 특성 연구)

  • Ahn, Ju-Hun;Choi, Ju-Hwan;Hong, Seung-Lae;Lee, Chang-Yull
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.4
    • /
    • pp.18-25
    • /
    • 2019
  • Studies on the fabrication of UAV by using 3D printer have been actively carried out. However, research on structural load characteristics in low temperature environment is insufficient. In this study, a composite sandwich structure with ordinary orbs structure was proposed, and the load characteristics for temperature condition changes were analyzed. The ordinary orbs and honeycomb structures were fabricated by using a FDM type 3D printer. The bending load test was carried out at room temperature and low temperature condition. The low temperature condition was classified into four cases. Bending load tests were performed in a low temperature chamber to maintain the required temperature conditions. As a result of the test, it was confirmed that the proposed ordinary orbs structure had better load characteristics at low temperatures than the existing honeycomb structure.

Hybrid DC-DC Converter For Power Efficiency Improvement Operating Over a Wide Load Power (넓은 부하전력에서 동작하는 전력 효율 향상을 위한 하이브리드 DC-DC 컨버터)

  • Woo, Ki-Chan;Mok, Jin-Won;Kim, Tae-Woo;Hwang, Seon-Kwang;Yang, Byung-Do
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.9
    • /
    • pp.1763-1770
    • /
    • 2016
  • This paper proposed hybrid converter to operate over a wide output load power. The switched-capacitor converter has a high efficiency at low load power and a low efficiency at high load power. On the contrary, the buck converter has a high efficiency at high load power and a low efficiency at low load power. The proposed hybrid converter has combination of the switched-capacitor converter and the buck converter. The switched-capacitor operates at low load power and buck converter operates at high load power, so that the hybrid converter is improved power efficiency at wide output load power. The hybrid converter was implemented with a $0.18{\mu}m$ CMOS process. The hybrid converter has a range of the load power between $50{\mu}W$and 100mW. The maximum power efficiencies are 93% and 77% at the buck converter and the switched-capacitor converter, respectively.

The Scheme for Efficient Driving of Engine/Generator-Battery in Series HEV (직렬형 HEV의 엔진/발전기-배터리 연계운전 방안)

  • 박영수;허민호;안재영;강신영;김광헌
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.423-426
    • /
    • 1999
  • This paper describes a driving scheme of the series hybrid electric vehicle that we have developed. Both series HEV and parallel HEV are well known. We chose series HEV because it provides good energy efficiency in urban driving and operates in all-electric mode in performance. And engine-Generator is driven at constant speed with constant load to maintain the low emission. And the battery supplies power during high-load and receive energy during low-load

  • PDF

Least Order Load Torque.Inertia Observer for Low Speed Drive of Motor Using (전동기 극저속 운전을 위한 최소차원 부하토크.관성 관측기)

  • Kim Young-Chun;Kim Eun-Gi;Cho Moon-Taek
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.575-579
    • /
    • 2006
  • In this paper, an instantaneous speed observer with a reduced order is proposed to implement an indirect control for a motor with excellent dynamic stability and performance in a very low speed region. The proposed observer can estimate the instantaneous speed in very low speed region and simplify the system configuration by adopting an least order load torque-inertia observer to estimate the load torque and the motor speed. Simulation are carried out to illustrate the performance of the proposed estimator at very low speed.

  • PDF

Voltage Regulation Method Considering Load Variation Characteristics of High and Low Voltage Distribution Line in Distribution System (시간 불일치성을 고려한 배전계통 전압조정방법)

  • Kim, T.E.;Kim, C.S.;Kim, J.E.;Son, J.M.;Park, J.K.;Rho, D.S.;Kim, K.H.;Cho, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.115-117
    • /
    • 2002
  • In general, it is supposed that load characteristics of high and low voltage distribution line are always coincidence. But in practical distribution system, voltage variation characteristics of high and low voltage distribution line are not same. Then in this paper, we proposes a voltage regulation method considering load variation characteristics of high and low voltage distribution line in distribution system.

  • PDF

A Study on the Delamination Growth in Composite Laminates Subjected to Low-Velocity Impact (저속 충격을 받는 복합 재료 적층판의 층간 분리 성장에 관한 연구)

  • 장창두;송하철;김호경;허기선;정종진
    • Journal of Ocean Engineering and Technology
    • /
    • v.16 no.6
    • /
    • pp.55-59
    • /
    • 2002
  • Delamination means that cracking occurs on the interface layer between composite laminates. In this paper, to predict the delamination growth in composite laminates subjected to low-velocity impact, the unit load method was introduced, and an eighteen-node 3-D finite element analysis, based on assumed strain mixed formulation, was conducted. Strain energy release rate, necessary to determine the delamination growth, was calculated by using the virtual crack closure technique. The unit load method saves the computation time more than the re-meshing method. The virtual crack closure technique enables the strain energy release rate to be easily calculated, because information of the singular stress field near the crack tip is not required. Hence, the delamination growth in composite laminates that are subjected to low-velocity impact can be efficiently predicted using the above-mentioned methods.

Low Speed Drive of Motor Using Least Order Load $Torque{\cdot}Inertia$ Observer (최소차원 토크${\cdot}$관성 관측기를 이용한 전동기 극저속 운전)

  • Kim, Eun-Gi;Jeon, Kee-Young;Oh, Bong-Hwan;Chung, Choon-Byeong;Lee, Hoon-Goo;Kim, Yong-Joo;Seo, Young-Soo;Han, Kyung-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.234-236
    • /
    • 2005
  • In this paper, an instantaneous speed observer with a reduced order is proposed to implement an indirect control for an motor with excellent dynamic stability and performance in a very low speed region. The proposed observer can estimate the instantaneous speed in very low speed region and simplify the system configuration by adopting a least order load torque-inertia observer to estimate the load torque and the rotor speed. Simulation are carried out to illustrate the performance of the proposed estimator at very low speed.

  • PDF

The algorithm of the load flow problem for integrated distributed generation network (분산전원의 특성을 고려한 조류계산의 새로운 알고리즘 고찰)

  • Nguyen, Dinh Hung;Nguyen, Minh Y.;Nguyen, Van Thang;Kim, Tae-Won;Kim, Kern-Joong;Yoon, Yong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.168-169
    • /
    • 2011
  • The aim of this paper is to present a new algorithm for the load flow problem using modified Newton-Raphson (NR) iteration method and a approach to derive a simple formula to compensate the reactive power at some heavy load bus. The reactive power source used in this research is the DG which is adjacent to the heavy load. Phenomena of low voltages may cause the load flow calculation process to diverge. In modified NR method, low voltages will be detected and corrected before the next iteration. Therefore, the results of load flow calculation process satisfy the voltage constraint i.e. higher than the lower voltage limit or higher than the critical voltage in case the conventional load flow diverges. Linearizing the power network using PTDFs is a simple method with accepted errors. A new value of voltage at the DG terminal is computed in terms of the voltage deviation of load buses. In this approach, solving the entire system is unnecessary.

  • PDF