• Title/Summary/Keyword: low leakage

Search Result 1,336, Processing Time 0.038 seconds

Harmonics Analysis of Leakage Current Waveforms and Surface Discharge for EPDM Polymer Insulator (EPDM 고분자 애자에 대한 표면방전 및 누설전류파형의 고조파분석)

  • 박재준;양태규
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.9
    • /
    • pp.1013-1021
    • /
    • 2004
  • This paper presents the results of spectrum analysis of leakage current waveforms on contaminated polymer insulators under fog conditions. This is a basic study on development of a monitoring for aging degree and surface pollution state using distortion rate(%) of 3rd and 5th harmonics according fundamental frequency[60Hz] under environment conditions. Arcing on the surface was always associated with distortion in the leakage current ; hence the low frequency components of the leakage current can be used as a means to evaluate the surface degradation. The results indicate that the distortion rate by spectrum analysis is available for the monitoring of contamination condition of EPDM Polymer insulators.

Comparisons between Analysis and Experiment for Leakage Flowrate and Stability depending on the Effect of the Height and the Length of Floating Ring Seal (플로팅 링 실의 길이와 높이 효과에 따른 누수 및 안정성에 대한 해석과 실험의 비교)

  • An, Kyoung-Min;Lee, Yong-Bok;Kim, Chang-Ho;Ha, Tae-Woong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.329-336
    • /
    • 2004
  • The lock-up position of the floating ring seal affects the leakage flowrate and the stability. And it is changed depending on the operating and geometry condition. In this paper, the leakage flowrate and stability with change of the height and length were investigated by theoretical analysis and experiment. The parameter of the height and length is expressed to the b and L. The decreasing of the b resulted in the increasing of equivalent whirl frequency ratio in the experimental result at the low speed and high pressure not such as theoretical analysis. As the L increased the leakage flowrate decreased and stiffness and direct damping coefficient increased in the experimental result. That was similar to the theoretical analysis.

  • PDF

A study on the characteristic of adhesion on the low temperature concrete of self adhesive waterproofing sheet using interface leakage test. (계면 누수를 통한 자착형 방수시트의 저온 부착 특성에 관한 연구)

  • Choi, Su-Young;Kim, Meong-Ji;Lee, Jung-Hoon;Choi, Sung-Min;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.234-235
    • /
    • 2014
  • Recently, waterproof construction used to self adhesive waterproofing sheet in the actual field in winter for reduce cost and term. However self adhesive waterproofing sheet's quality is declined in low temperature condition. So, this study was to confirm on the low temperature condition of concrete substrate effecting the adhesion of self adhesion waterproofing sheet using interface leakage test. As a result of this study, self adhesion waterproofing sheet must not be used at temperature below 5℃. Also, adhesion between waterproofing sheet and concrete is declined in low temperature.

  • PDF

Dependence of Stress-Induced Leakage Current on Low Temperature Polycrystalline Silicon TFTs

  • Chen, Chih-Chiang;Chang, Jiun-Jye;Chuang, Ching-Sang;Wu, Yung-Fu;Sheu, Chai-Yuan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.622-625
    • /
    • 2003
  • The dependence of stress-induced leakage current on LTPS TFTs was characterized in this study. The impacts of poly-Si crystallization, gate insulator, impurity activation, hydrogenation process and electrostatic discharge damage were investigated. It was observed more TFTs instable characteristic under those process-assisted processes. According to the LTPS roadmap, smaller geometric and low temperature process were the future trend and the stress-induced leakage current should be worthy of remark.

  • PDF

Fractal Analysis of the Surface in Thin Film Capacitors

  • Hong, Kyung-Jin;Min, Yong-Ki;Cho, Jae-Cheol
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.11C no.2
    • /
    • pp.18-22
    • /
    • 2001
  • The thin films of high permitivity in ferroelectric materials using a capacitor are applied to DRAMs and FRAMs. (Ba, Sr)TiO$_3$ thin as ferroelectric materials were prepared by the sol-gel method and made by spin-coating on the Pt/Sio$_2$/Si substrate at 4,000 [rpm] for 10 seconds. The structural characteristics of the surface were analyzed by fractal dimension. The thickness of BST ceramics thin films was about 260∼280 [nm]. The property of the leakage current was stable with 10-9∼10-11[A] when the applied voltage was 0∼3[V]. BST thin films ha low leakage current properties when fractal dimension was low and a coating area was high.

Low Leakage Current Circular AlGaN/GaN Schottky Barrier Diode (누설전류를 줄이기 위한 원형 AlGaN/GaN 쇼트키 장벽 다이오드)

  • Kim, Min-Ki;Lim, Ji-Yong;Choi, Young-Hwan;Kim, Young-Shil;Seok, O-Gyun;Han, Min-Koo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.9
    • /
    • pp.751-755
    • /
    • 2009
  • We proposed circular AlGaN/GaN schottky barrier diode, which has no mesa structure near the current path. Proposed device showed low leakage current of 10 nA/mm at -100 V while that of the rectangular device was 34 nA/mm at the same condition. Proposed circular AIGaN/GaN SBD showed high forward current of 88.61 mA at 3,5 V while that of the conventional device was 14.1 mA at the same condition.

Carrier Based LFCPWM for Leakage Current Reduction and NP Current Control in 3-Phase 3-Level Converter (3상 3-레벨 컨버터의 누설전류 저감과 NP 전류 제어를 위한 캐리어 기반 LFCPWM)

  • Lee, Eun-Chul;Choi, Nam-Sup
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.446-454
    • /
    • 2022
  • This study proposes a carrier-based pulse width modulation (PWM) method for leakage current reduction and neutral point (NP) current control in a three-phase three-level converter, which is a carrier-based PWM version of the previously proposed low-frequency common mode voltage PWM. Three groups of space vectors with the same common mode voltage are used. When the averaged NP current needs to be positive or negative, the specific groups are employed to produce low-frequency common mode voltages. The validity of the proposed PWM method is verified through experiments.

A Study on the Reliability Improvement Plan on Electric Leakage & Ground Fault of Low-voltage Electrical Line (저압전로의 누전.지락에 대한 신뢰성향상 방안에 관한 연구)

  • Kang, Kyung-Won;Yoon, Myung-O;Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.136-145
    • /
    • 2011
  • One of a large proportion among the causes of fire is electrical factors, and of fire by electric factors, the accident which accounted for over certain percentage is electric leakage and ground fault. In order to reduce the electric leakage and ground fault, the technical guidelines on the protection of ground fault in the low-voltage electrical line (KECG 1091-2011) was amended for reflecting recent international standard, IEC 60364-4-41, and new conservation methods, which improved the reliability by recovering the facility's all-time use operation and breakdown defect, was on the rise. Accordingly, in this paper, after grasping the fire's status for last 10 years and analyzing the risk of electrical fires, and as a way to improve the electric leakage and ground fault accident which accounted for more than certain percentage, the revision of KECG 1091-2011 will be reviewed. And then, after applying to the preventive conservation methods in order to enhance the protection reliability of electric leakage and ground fault detection, the problems at issue routine inspection scheme and durable years scheme in time-scheduled conservation method are listed, along with suggestion of the problem-solving scheme, and the leakage current integrated monitoring systems and digital electric leakage devices by status monitor conservation method will be proposed.

An Advanced Embedded SRAM Cell with Expanded Read/Write Stability and Leakage Reduction

  • Chung, Yeon-Bae
    • Journal of IKEEE
    • /
    • v.16 no.3
    • /
    • pp.265-273
    • /
    • 2012
  • Data stability and leakage power dissipation have become a critical issue in scaled SRAM design. In this paper, an advanced 8T SRAM cell improving the read and write stability of data storage elements as well as reducing the leakage current in the idle mode is presented. During the read operation, the bit-cell keeps the noise-vulnerable data 'low' node voltage close to the ground level, and thus producing near-ideal voltage transfer characteristics essential for robust read functionality. In the write operation, a negative bias on the cell facilitates to change the contents of the bit. Unlike the conventional 6T cell, there is no conflicting read and write requirement on sizing the transistors. In the standby mode, the built-in stacked device in the 8T cell reduces the leakage current significantly. The 8T SRAM cell implemented in a 130 nm CMOS technology demonstrates almost 100 % higher read stability while bearing 20 % better write-ability at 1.2 V typical condition, and a reduction by 45 % in leakage power consumption compared to the standard 6T cell. The stability enhancement and leakage power reduction provided with the proposed bit-cell are confirmed under process, voltage and temperature variations.

Flow Characteristics of a Tip Leakage Vortex at Different Flow Rates in an Axial Flow Fan (유량에 따른 축류홴의 익단누설와류 특성)

  • Jang, Choon-Man;Kim, Kwang-Yong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1383-1388
    • /
    • 2004
  • The flow characteristics in the blade passage of a low speed axial flow fan have been investigated by experimental analysis using a rotating hot-wire sensor for design and off-design operating conditions. The results show that the tip leakage vortex is moved upstream when flow rate is decreased, thus disturbing the formation of wake flow near the rotor tip. The tip leakage vortex interfaces with blade pressure surface, and results in high velocity fluctuation near the pressure surface. From the relative velocity distributions near the rotor tip, large axial velocity decay is observed at near stall condition, which results in large blockage compared to that at the design condition. Througout the flow measurements using a quasi-orthogonal measuring points to the tip leakage vortex, it is noted that the radial position of the tip leakage vortex is distributed between 94 and 96 percent span for all flow conditions. High spectrum density due to the large fluctuation of the tip leakage vortex is observed near the blade suction surface below the frequency of 1000 Hz at near stall condition.

  • PDF