• 제목/요약/키워드: low leakage

검색결과 1,336건 처리시간 0.061초

누설특성을 고려한 GDI 엔진용 연료펌프의 고압생성 증진에 관한 연구 (A Study on the Pressure Increment of Fuel Pump for GDI Engines Considering Leakage Flows)

  • 나병철;김병수;최석우
    • 대한기계학회논문집B
    • /
    • 제24권6호
    • /
    • pp.785-791
    • /
    • 2000
  • GDI (Gasoline Direct Injection) engines are considered as one of the candidates for next generation engines of passenger cars, which reduce exhaust emissions and fuel consumption. In GOI engines, a high-pressure gasoline supply system is required to directly inject the fuel to combustion chambers. Because of low lubricity of gasoline fuel, the clearance between a plunger and a barrel in GDI fuel pumps is too wide to achieve smooth hydrodynamic lubrication. Thus, it is difficult to generate high-pressure condition in GDI fuel pump since large amount of leakage flow occurs between the plunger and the barrel In this study, an optimum plunger design is presented to minimize leakage in the aspect of flow control. This paper analyzes leakage flow characteristics in the clearance to improve pumping performance of GDI fuel pumps. Effects of groove in the plunger are studied according to variations of depth and width. Evaluations of pumping performance are determined by the amount of pressure drop in the leakage path assuming a constant leakage flows. Both of turbulence and incompressible models are introduced in CFD (Computational Fluid Dynamics) analysis. Design parameters have been introduced to minimize leakage in limited space, and a methodological study on geometrical optimization has been conducted. As results of CFD analysis in various geometrical cases, optimum groove depths have been found to generate maximum sealing effects on gasoline fuel between the plunger and the barrel. This procedure offers a methodological way of an enhancement of plunger design for high-pressure GDI fuel pumps.

국부발진기에서의 누설신호의 새로운 제거방식 (A Novel Method to Reduce Local Oscillator Leakage)

  • 이병제;강기조
    • 한국전자파학회논문지
    • /
    • 제11권2호
    • /
    • pp.294-301
    • /
    • 2000
  • RF(radio frequency) 시스템의 송신탄을 설계할 때 고려해야 할 중요한 요소 중의 하나인 EMI(Electro magnetic interference)의 규격시험에서 항상 문제시되는 것이 송신기의 출력 스펙트럼에서 나타나는 불요 신호(Spurious interference) 이다. 이 불요 성분들 중 특히 문제가 되고 있는 것이 국부발진기(LO; Local oscillator)로부터 누설되는 LOL(Local oscillator leakage) 성분이다. 이 LOL성분은 국부발진기에서 누설(leakage)되어 RF단의 증폭기를 통하여 증폭되어 최종 출력에서 매우 높은 선호의 크기로 나타난다. 일반적으로 LOL을 제거하기 위해 서 너치필터(Notch filter) 또는 대역통과필터 (Band pass filter)를 사용해왔다. 본 논문에서는 국부발진기로부터 누설되는 불요 성분, 즉 LOL성분을 제거하는 방법으로 LOL과 동일한 크기를 가지고 위상 차이가 $180^{\circ}$인 신호를 국부발전기의 출력에서 만들어 믹서( Mixer)의 출력단에 더함으로써 LOL성분을 효과적으로 제거한다. 본 방 식을 무선랜(WLAN; Wireless 1$\infty$al area network) 시스템에 적용한 결과. 기존의 방식보다 30 dB 이상 LO 누설선호플 감쇄시킬 수 있었다 또한 본 방식은 RF 시스댐을 소형화 및 MMIC(Monolithic microwave integrated C circuit)화 할 경우 종전의 방법보다 효과적일 것으로 기대된다.

  • PDF

Feasibility study of β-ray detection system for small leakage from reactor coolant system

  • Jang, Jaeyeong;Jeong, Jae Young;Park, Junesic;Cho, Young-Sik;Pak, Kihong;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2748-2754
    • /
    • 2022
  • Because existing reactant coolant system (RCS) leakage detection mechanisms are insensitive to small leaks, a real-time, direct detection system with a detection threshold below 0.5 gpm·hr-1 was studied. A beta-ray detection system using a silicon detector with good energy resolution for beta rays and a low gamma-ray response was proposed. The detection performance in the leakage condition was evaluated through experiments and simulations. The concentration of 16N in the coolant corresponding to a coolant leakage of 0.5 gpm was calculated using the analytic method and ORIGEN-ARP. Based on the concentration of 16N and the measurement of the silicon detector with 90Sr/90Y, the beta-ray count rate was estimated using MCNPX. To evaluate the effect of gamma rays inside the containment building, the signal-to-noise ratio (SNR) was calculated. To evaluate the count rate ratio, the radiation field inside the containment building was simulated using MCNPX, and response evaluation experiments were performed using beta and gamma rays on the silicon detector. The expected beta-ray count rate at 0.5 gpm leakage was 7.26 × 105 counts/sec, and the signal-to-background count rate ratio exceeded 88 for a transport time of 10 s, demonstrating its suitability for operation inside a reactor containment building.

직류와 60 Hz 교류가 중첩된 전압에 대한 산화아연 피뢰기 소자의 누설전류 특성 (Characteristics of ZnO Arrester Blocks Leakage Currents under Mixed Direct and 60 Hz Alternating Voltages)

  • 이복희;강성만;박건영
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권1호
    • /
    • pp.23-29
    • /
    • 2005
  • This paper presents the characteristics of leakage currents flowing through ZinC Oxide(ZnO) surge arrester blocks under mixed direct and 60 Hz alternating voltages. A mixed voltage, in which an alternating voltage is superimposed upon a direct voltage, appears on the HVDC system network. The mixed direct and alternating voltage generator with a peak open-circuit of 10 kV was designed and fabricated. The leakage currents and V-I curves for the fine and used ZnO surge arrester blocks were measured as a function of the voltage ratio k, where the voltage ratio k is defined as the ratio of the peak of alternating voltage to the peak of the mixed voltages. The resistive component in the leakage current in the low conduction region is significantly increased with increasing the voltage ratio k. The V-I characteristic curves for the mixed voltages lies between the direct and alternating characteristics, and the cross-over phenomenon in the high conduction region was appeared.

치과용 Varnish가 충전재의 변연누출에 미치는 영향에 관한 연구 (A STUDY OF CAVITY VARNISH APPLICATION ON THE MARGINAL LEAKAGE OF THE VARIOUS DENTAL RESTORATIONS)

  • 김희중;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제9권1호
    • /
    • pp.69-79
    • /
    • 1983
  • This study was undertaken to evaluate the effects of varnish application and thermocycling on the marginal leakage. 240 cavities of Class V were prepared on the 120 extracted premolars, and the cavities were filled with amalgam, Heliosit$^{(R)}$, and Hipol$^{(R)}$ after application of Copalite$^{(R)}$ or Duraphat$^{(R)}$. All specimens were immersed in methylene blue solution for 24 hours after thermocycling at $4^{\circ}C$ and $60^{\circ}C$, embedded in acrylic resin, and sectioned with low speed saw into two parts. The sectioned specimens observed with the metallurgical microscope. The following results were obtained: 1. The marginal seal was more effective in the amalgam-filled cavities after application of Copalite$^{(R)}$ threetimes or an application of Duraphat$^{(R)}$ varnish than in those without varnish applications. 2. Of the composite resin-filled cavities, the leakage of the varnish applied cases showed much more than without application. 3. There was no significant difference in the effect of marginal sealing between Copalite$^{(R)}$ and Duraphat$^{(R)}$ applications. 4. There was a significant difference in the degree of the marginal leakage of amalgam-filled cavities between the groups of thermocycling times, but no significant difference in the resin-filled cavities. 5. There was no significant difference in the degree of the marginal leakage between the Heliosit$^{(R)}$ and the Hipol$^{(R)}$ resin-filled cavities.

  • PDF

모래자갈과 누수성 토질을 기반으로하는 용수로의 누수방지에 대한 연구 (A Study on the Leakage Interception Work in the Irrigation Canal Founding on the Sandy Gravel or the Porous Soil)

  • 강신업
    • 한국농공학회지
    • /
    • 제12권2호
    • /
    • pp.1965-1970
    • /
    • 1970
  • The experiment was carried out in order to improve the leakage stopping work in the irrigation canal founding on the porous soil. But the experiment had many problems to be studied more owing to the insufficient time and facilities. The results obtained are summarized as follows; 1. Polyethylene film is estimated not to make strength decrease owing to buring in the subsoil, but to make owing to the sunlight. 2. Coated nylon shows the tendency to deteriorate strength when it is buried in the earth or exposed to the sun for long time, but leakage is all but impermeability generally. 3. Leakage loss rates for one hour show some differences in the canal to be full with water in accordance with operating methods, that is, the clay lining section is 12.6%, the coated nylon lining section is 1.7%, the polyethylene film lining section is 1.3%, respectively. 4. Leakage quantities per wetted perimeter unit area show $3.556cc/cm^2/hr$. in the clay lining section, $1.574cc/cm^2/hr$. in the coated nylon section, $0.695cc/cm^2/hr$. in the polyethylene film lining section, respectively. 5. When the construction fund make the clay lining section as a standard, the polyethylene film section is 92.1%, the coated nylon section is 174.2%, respectively. But, the unit cost of execution may be low when the polyethylene film and the coated nylon will enable to mass-produce for the purpose of execution.

  • PDF

양극성 DC 배전용 3상 3-레벨 컨버터의 누설전류 저감과 NP 전류 제어를 위한 공간벡터 PWM 방법 (Space Vector PWM Method for Leakage Current Reduction and NP Current Control in 3-phase 3-level Converter used in Bipolar DC Distribution System)

  • 이은철;최남섭;김희준
    • 전력전자학회논문지
    • /
    • 제23권5호
    • /
    • pp.336-344
    • /
    • 2018
  • This study proposes a new PWM method for leakage current reduction and neutral point (NP) current control in three-phase three-level converter employed in bipolar DC distribution systems. The proposed PWM method uses medium vectors only when there is no need to control the NP current. Thus, common mode voltages are held constant to realize zero leakage current. Some space vectors that produce low-frequency common mode voltages are employed to minimize leakage currents when the average NP current needs to be a positive or negative value. The proposed space vector PWM is implemented based on barycentric coordinate. The validity of the proposed PWM method is verified by simulations and experiments.

Variations of Interface Potential Barrier Height and Leakage Current of (Ba, Sr)$TiO_3$ Thin Films Deposited by Sputtering Process

  • Hwang, Cheol-Seong;Lee, Byoung-Taek
    • The Korean Journal of Ceramics
    • /
    • 제2권2호
    • /
    • pp.95-101
    • /
    • 1996
  • Variations of the leakage current behaviors and interface potential barrier $({\Phi}_B)$ of rf-sputter deposited (Ba, Sr)$TiO_3$ (BST) thin films with thicknesses ranging from 20 nm to 150nm are investigated as a function of the thickness and bias voltages. The top and bottom electrodes are dc-sputter-deposited Pt films. ${\Phi}_B$ critically depends on the BST film deposition temperature, postannealing atmosphere and time after the annealing. The postannealing under $N_2$ atmosphere results in a high interface potential barrier height and low leakage current. Maintaining the BST capacitor in air for a long time reduces the ${\Phi}_B$ from about 2.4 eV to 1.6 eV due to the oxidation. ${\Phi}_B$ is not so dependent on the film thickness in this experimental range. The leakage conduction mechanism is very dependent on the BST film thickness; the 20 nm thick film shows tunneling current, 30 and 40 nm thick films show Shottky emission current.

  • PDF

자기 포화와 누설자속이 고려된 자기등가회로법을 이용한 클로우 폴 스테핑 모터의 요크 형상 설계 (Yoke Shape Design of Claw-Poles Stepping Motor Using Modified Magnetic Equivalent Circuit Method Including Magnetic Saturation Effect and Leakage Flux)

  • 이형우;조수연;배재남;손병욱;박경진;이주
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1942-1946
    • /
    • 2009
  • This paper presents a shape design process of Claw-Poles Stepping Motor(CPSM) using Modified Magnetic Equivalent Circuit Method(MMEC). Because this motor is adopted on low power devices, the motor size is a very small type. But it have a very strong permanent magnet. So magnetic saturation effect happens on yoke teeth of CPSM. Also this magnetic saturation effect causes more leakage flux component between yoke tooth have another pole. In this motor type, it is essential to design a shape of yoke teeth for avoiding the magnetic saturation effect and the leakage flux. In this paper, MMEC including the magnetic saturation effect and the leakage flux component was used for design process. Comparing with data calculated by using the MMEC and results analyzed by 3-D FEM, it could be stated that the design process with MMEC was reasonable. Finally, the model has the optimized shape of yoke teeth was compared with a conventional model for no-load Back EMF and torque at steady-state operation.

환경조건에 따른 EPDM 고분자 애자의 누설전류파형과 스펙트럼 분석 (Leakage Current Waveforms and Spectrum Analysis of EPDM Polymer Insulator according to Environment Condition)

  • 박재준;김정부;송영철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.82-86
    • /
    • 2004
  • This research is about the result of leakage current waveform about the situation of surface leakage current and environmental changes(Salt fog, clean fog and rain) by EPDM polymer insulators' amount of salt. The researcher presents the result of changing about fundamental harmonic, 3rd harmonic and 5th harmonic from starting point of supplying power to flashover. In this study, researched environmental affects (clean fog, salt fog and rain) about surface aging of polymer insulators and used frequency spectrum of leakage current waveform to develop the diagnostic technique of surface aging. When amount of salt contents changed, surface aging stage and the degree of aging (distortion factor) about 3rd and 5th harmonic waveform on low frequency harmonic wave. The distortion factor which is harmonic percentage about basic harmonic is important pointer to evaluate the surface condition of polymer insulators.

  • PDF