• Title/Summary/Keyword: low intensity laser

Search Result 115, Processing Time 0.028 seconds

The Effects of Low Level Laser Therapy on Decrease of Atopic Dermatitis Symptoms (저출력 레이저 치료(LLLT)가 아토피 피부염의 증상 완화에 미치는 영향)

  • Yoon, Hye-Joon;Yoon, Jong-Sung;Kim, Deog-Gon;Lee, Jin-Yong
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.23 no.3
    • /
    • pp.193-206
    • /
    • 2009
  • Objectives The purpose of this study is to evaluate the effects of Low Level Laser Therapy on Atopic dermatitis symptoms. Methods 19 patients (7 men, 12 women) were involved in this study. The intensity of SCORAD index (Erythema/darkening, Edema/papulation, Oozing/crust, Excoriation, Lichenification/prurigo, Dryness) and the symptom of SCORAD index (Pruritus) in two regions were measured. One region was treated by LLLT, the other region was not treated. Then a comparative study of index score of two regions was analyzed. Results After treatment, there were statistically significant differences in Edema/papulation, Excoriation (p<0.001), Oozing/crust (p<0.01), and Pruritus(p<0.05) index. Conclusions Based on the results, we concluded that LLLT is an effective in the treatment of atopic dermatitis. Also, further controlled studies with clinical cases of appropriate treatment time, wavelength, and intervals are needed.

  • PDF

Effects of single-dose, low-level laser therapy on pain associated with the initial stage of fixed orthodontic treatment: A randomized clinical trial

  • Qamruddin, Irfan;Alam, Mohammad Khursheed;Abdullah, Habiba;Kamran, Muhammad Abdullah;Jawaid, Nausheen;Mahroof, Verda
    • The korean journal of orthodontics
    • /
    • v.48 no.2
    • /
    • pp.90-97
    • /
    • 2018
  • Objective: The aim of this study was to assess the analgesic effect of a single application of low-level laser therapy (LLLT) on spontaneous pain and pain on chewing after placement of initial archwires. Methods: Forty-two patients (26 women, 16 men) were randomly recruited for this split-mouth randomized clinical trial. Each patient received super-elastic nickel-titanium (NiTi) initial archwires (0.012, 0.014, 0.016, and 0.018-inch [in]) in the maxilla for leveling and alignment for an interval of 4 weeks between archwires. One side of the mouth was randomly designated as experimental, while the other side served as placebo. After insertion of each archwire, the experimental side was irradiated with a diode laser for 3 seconds each on 5 points facially and palatally per tooth, from the central incisor to first molar. On the placebo side, the laser device was held the same way but without laser application. A numerical rating scale was used to assess the intensity of spontaneous and masticatory pain for the following 7 days. The Mann-Whitney U test was used to compare pain scores between sides. Results: Patients in the LLLT group exhibited significantly lower mean scores for spontaneous pain after insertion of the initial two archwires (0.012-in and 0.014-in NiTi; p < 0.05), while there was no significant difference for 0.016-in and 0.018-in wires between the LLLT and placebo groups. LLLT significantly reduced chewing pain scores (p < 0.05) for all archwires. Conclusions: A single dose of LLLT considerably lessened postoperative pain accompanying the placement of super-elastic NiTi wires for initial alignment and leveling.

Double Pulse Raman-Laser Induced Plasma Spectroscopy System for Space Exploration (우주 탐사를 위한 이중펄스 라만-레이저 유도 플라즈마 분광 시스템 개발 연구)

  • Yang, Jun-Ho;Yoh, Jai-Ick
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.6
    • /
    • pp.479-487
    • /
    • 2020
  • A new double-pulse laser system that combines Raman and laser induced plasma spectroscopy (LIPS) in a single unit is proposed. The study attempts to enhance the laser induced plasma signals while simultaneously extracting the desired molecular signals from Raman spectroscopy. In low pressure conditions such as the lunar atmosphere, the measuring of plasma emission is hard because of the low electron density and short persistence time causing a rapid plasma expansion. Furthermore, in the integration of the detecting system aimed at space exploration, the minimization of laser system is important in terms of the payload mass. Simultaneous molecular and atomic detection that gave highly resolved spectral data at pressure below 0.07 torr is demonstrated amongst eight rock samples test. The plasma stacking produced from the double-pulse laser enhanced the signal intensity of calcium and oxygen lines in calcite matrix by twofold, compared to a conventional LIPS.

Design of Monolithically Integrated Vertical Cavity Laser with Depleted Optical Thyristor for Optically Programmable Gate Array (Optically Programmable Gate Array 구현을 위한 수직 공진형 완전공핍 광싸이리스터)

  • Choi, Woon-Kyung;Kim, Do-Gyun;Choi, Young-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1580-1584
    • /
    • 2009
  • We have theoretically analyzed the monolithic integration of vertical cavity lasers with depleted optical thyristor (VCL-DOT) structure and experimentally demonstrated optical logic gates such as AND-gate, OR-gate, and INVERTER implemented by VCL-DOT for an optical programmable gate array. The optical AND and OR gates have been realized by changing a input bias of the single VCL-DOTs and all kinds of optical logic functions are also implemented by adjusting an intensity of the reference input beams into the differential VCL-DOTs. To achieve the high sensitivity, high slope efficiency and low threshold current, a small active region of lasing part and a wide detecting area are simultaneously designed by using a selective oxidation process. The fabricated devices clearly show nonlinear s-shaped current-voltage characteristics and lasing characteristics of a low threshold current with 0.65 mA and output spectrum at 854 nm.

1.25 Gb/s Broadcast Signal Transmission in WDM-PON Based on Mutually Injected Fabry-Perot Laser Diodes

  • Yoo, Sang-Hwa;Mun, Sil-Gu;Kim, Joon-Young;Lee, Chang-Hee
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.101-106
    • /
    • 2012
  • We demonstrate a cost effective broadcast signal transmission at 1.25-Gb/s with 100 GHz channel spacing based on a broadband light source (BLS) for a wavelength division multiplexing-passive optical network (WDM-PON). The BLS is implemented by using mutually injected Fabry-Perot laser diodes (MI F-P LDs). The error-free transmission without a forward error correction (FEC) is achieved by its low relative intensity noise (RIN). The number of usable modes is determined by RIN and/or extinction ratio (ER) in the spectrum sliced light output.

Direct Aerosol Analysis by Time Resolved Laser Plasma Spectroscopy - Improvement by Single Shot Measurements

  • Schechter, Israel
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.779-786
    • /
    • 1995
  • Environmental and industrial aerosols can be analyzed on-line by laser plasma spectroscopy. The main problem in direct (no preparation or presorting) aerosol analysis is the extensive spectral fluctuations. A method to partially solve this problem is proposed. It is based on single shot measurements and application of a special rejection algorithm. The major factors that influence the spectral variations are discussed, in relation to the correction possibility by a rejection program. The method works well when average intensity of the single spectra is relatively high, as compared to detector's saturation limit. If intensities are too low, the accumulation of readout noise is critical, and no improvement is expected.

  • PDF

A Study on the Fluorescence Imaging System Packaging and Optical Intensity Characteristics (형광 이미징 시스템의 패키징 및 강도 특성 연구)

  • Kim, Taehoon;Cho, Sang Uk;Park, Chan Sik;Lee, Hak-Guen;Kim, Doo-In;Jeong, Myung Yung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.3
    • /
    • pp.37-41
    • /
    • 2016
  • In this paper, we introduced a near infrared fluorescence imaging system that has long working distance and analyzed on the effects of measurement variables such as gain, exposure time, working distance, magnification. Fluorescence signal intensity is growing up according to exposure time and magnification increasing, and it is getting stronger according to increase of gain, but the background signal intensity is getting stronger together. It causes low SBR. Due to a laser irradiation method, laser intensity distribution of the introduced system is not uniform and it makes fluorescence signal weak. So, we proposed a solution.

Systemic and local effects of doxycycline and low-intensity laser treatment on periodontitis in rats

  • Silveira, Glauco Rodrigues Carmo;Lima, Daniela Coelho de;Cintra, Luciano Tavares Angelo;Brigagao, Maisa Ribeiro Pereira Lima;Ervolino, Edilson;Fernandes, Leandro Araujo
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.1
    • /
    • pp.39-53
    • /
    • 2022
  • Purpose: This study evaluated the systemic and local effects of doxycycline (DOX) and low-intensity laser (LIL) treatment as adjuvants to scaling and root planing (SRP) in the treatment of experimental periodontitis in rats. Methods: The sample consisted of 180 male rats (Rattus norvegicus albinus, Wistar), of which 30 did not receive induction of periodontal disease (negative control [NC] group) and 150 received induction of periodontal disease in the lower first molar. After 7 days, the ligature was removed, and the animals were divided into the following groups: NT (no treatment), SRP (SRP), DOX (SRP and DOX irrigation), LIL (SRP and laser irradiation), and DOX+LIL (SRP, DOX, and LIL). The animals were euthanized at 7, 15, and 30 days; thereafter, biochemical, radiographic, histological, and immunohistochemical analyses were performed. Results: In the intragroup analysis, lower concentrations of α-1-glycoprotein acid (α-1-Ga) and complement 3 (C3) were observed in the DOX+LIL group than in all other groups at all time points, as well as lower levels of complement 4 (C4) at 15 and 30 days (P<0.001). Less bone loss was observed in the DOX, LIL, and DOX+LIL groups than in the NC and SRP groups at all time points (P<0.001). There was a smaller number of tartrate-resistant acid phosphatase (TRAP)-positive cells in the DOX+LIL group than in the other groups at all time points (P<0.001). Positive correlations were observed between the systemic levels of α-1-Ga, C3, and C4 and the number of TRAP-positive cells. Conclusions: The combination of DOX with LIL as SRP adjuvants was effective both systemically and locally for the treatment of experimental periodontitis in rats.

Dependence of Thermal Annealing Conditions on Photoluminescence in $SiO_2$ films

  • Lee, Jae-Hee;Lee, Weon-Sik;Kim, Kwang-Il
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.102-102
    • /
    • 1999
  • Visible photoluminescence(PL) in si-implanted SiO2 films on crystaline silicon were observed. Thermal oxide films of 1 ${\mu}{\textrm}{m}$ thickness on P-type crystal silicon were made and si+ ions were implanted with 200keV acceleration voltage on ti. Argon laser (wavelength 488nm) and PM tube were used for PL measurements. As annealing time increased at low temperature, the visible PL intensity are increased and the peak positions are changed. On the other hand, with increasing annealing time at high temperature, the visible PL intensity are disappeared. From the PL peaks and intensity changes, XRD results, and TEM observations, we will discuss the origin of PL in Si+-implanted SiO2 films with oxygen righ defects and silicon rich defects.

  • PDF

Cross-Correlation Measurements of Phase Noise Induced by Relative Intensity Noise in Photodetectors

  • Cao, Zhewei;Yang, Chun;Zhou, Zhenghua
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.694-697
    • /
    • 2016
  • Up-converted phase noise, which is induced by the low-frequency relative intensity noise (RIN) of a laser through AM-PM conversion within a photodetector (PD), is first measured here by means of a cross-correlation method. Our proposed measurement system can isolate the RIN-induced phase noise from noise contributions of other components, such as amplifiers, modulators, and mixers. In particular, shot noise and thermal noise generated from the PD are also suppressed by this method, so that standalone characteristics of the RIN-induced phase noise can be obtained. Experimental results clearly show the quantitative relationship between the RIN-induced phase noise and the incident optical power of the PD. Our findings indicate that the least RIN-induced phase noise appeared at the saturation point of the PD, which is about -162 dBc/Hz at 10 kHz offset.