• 제목/요약/키워드: low frequency inverter

검색결과 397건 처리시간 0.024초

새로운 방식의 단상 인버터를 이용한 태양광 시스템 구현 (A New Solar Energy Conversion System Implemented using Single Phase Inverter)

  • 홍정표;김태화;원태현;권순재;홍순일;김종달
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.488-491
    • /
    • 2006
  • In this paper proposed method of maximum power point tracking using boost converter for a connected single phase inverter with photovoltaic system. The maximum power point tracking control is based on generated circuit control MOSFET switch of boost converter and single phase inverter uses predicted current control to control four IGBT's switch in full bridge. The predicted current control provide current with sinusoidal wave shape and inphase with voltage. The generation control circuit allows each photovoltaic module to operate independently at peak capacity, simply by detecting of the output power of the system. Furthermore, the generation control circuit attenuates low-frequency ripple voltage, which is caused by the full-bridge inverter, across the photovoltaic modules. Consequently, the output power of system is increased due to the increase in average power generated by the photovoltaic modules. The effectiveness of the proposed inverter system is confirmed experimentally and by means of simulation.

  • PDF

단상 인버터를 이용한 새로운 태양광 에너지 변환 시스템 구현 (A New Solar Energy Conversion System Implemented Using Single Phase Inverter)

  • 김실근;홍순일
    • 조명전기설비학회논문지
    • /
    • 제20권7호
    • /
    • pp.74-80
    • /
    • 2006
  • 본 논문은 새로운 태양광 에너지 변환 기술에 의한 연계형 단상 인버터 제어기술을 나타내었다. 최대전력 점 추적제어는 두 부스터 컨버터의 MOSFET 스위치 제어 발생회로에 기초하고 단상 인버터는 풀 브리지의 4개 IGBT 스위치에 의해 전류 추종제어 된다. PV 모듈의 발생전력 제어회로는 PV 모듈의 출력 전압, 전류 검출에 의해 최대전력 점 제어한다. 결국 PV 모듈 양단은 인버터 입력전압으로 낮은 리플 전압을 유지하고 출력은 증가한다. 제안한 태양광 인버터 시스템의 효과가 시뮬레이션과 실험을 통하여 입증되었다.

계통연계 인버터의 인덕터 최적화 기법을 통한 LCL 필터 설계 (Design of LCL Filter through Inductor Optimization Method in Grid-Connected Inverter)

  • 장재하;김경화
    • 조명전기설비학회논문지
    • /
    • 제28권11호
    • /
    • pp.58-67
    • /
    • 2014
  • A grid-connected inverter used for renewable energy resources produces harmonic components in the switching frequency. To effectively reduce switching harmonic components, several types of filter are generally used in the output stage of the grid-connected inverter. Many research works on LCL filter design have been done to maintain the performance with low cost. However, it is not easy to make the filter design be economical and optimal due to the varying characteristic of magnetic core and redundancy design by experience. In this paper, a design method for a LCL filter is presented through the inductor optimization scheme in view of the size and cost when the inductor is manufactured using the magnetic core. The effectiveness is verified through tests using a 3kW grid-connected inverter by simulations and experiments.

위상 변위제어기법을 이용한 저주파 다중레벨 스위칭 방식 (Low frequency Multi-level Switching Strategy based on Phase-Shift Control)

  • 송성근;이상훈;남해곤;박성준;이만형
    • 전력전자학회논문지
    • /
    • 제11권6호
    • /
    • pp.520-528
    • /
    • 2006
  • 동일한 변압기를 사용하는 공통암 타입의 절연형 다중레벨 인버터에서 스위칭 주파수를 저감하기 위해 새로운 위상변위제어기법을 제안 하였다. 제안된 스위칭 방식은 인버터의 각 암이 기본주파수당 한번만을 스위칭을 하는 스텝 펄스파 방식을 사용하여 동일한 스위칭 주파수를 유지할 수 있다. 제안된 스위칭 방식의 타당성을 검증하기 위해 기존의 동일변압기를 이용한 멀티레벨 인버터의 스위칭 패턴과 제안된 위상변위 제어방식을 이용한 멀티레벨 인버터의 스위칭 패턴을 시뮬레이션하고 실험을 통해 비교 하였다.

Cascaded H-bridge PWM 멀티레벨인버터의 스위칭 손실 저감을 위한 효율적인 스위칭 패턴 (Efficient Switching Pattern to Decrease Switching Losses in Cascaded H-bridge PWM Multilevel Inverter)

  • 정보창;김선필;김광수;박성준;강필순
    • 전기학회논문지
    • /
    • 제62권4호
    • /
    • pp.502-509
    • /
    • 2013
  • It presents an efficient switching pattern, which expects a reduction of switching losses in a cascaded H-bridge PWM multilevel inverter. By the proposed switching scheme, the lower H-bridge module operates at low frequency of 60[Hz] because it assigns to transfer most load power. The upper H-bridge module operates at high frequency of PWM switching to improve THD of output voltage. The proposed switching pattern applies to cascaded H-bridge multilevel inverter with PD, APOD, bipolar, and unipolar switching methods. By computer-aided simulations, we verify the validity of the proposed switching scheme. Finally, we prove that the proposed PD and APOD switching patterns are better than those of the conventional one in efficiency.

구형파 및 PWM 인버터 조합에 의한 오존발생용 인버터 (The Invert for ozone generator by mixed square_wave and PWM)

  • 박노식;박성준;원태헌;안진우;김철우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1193-1195
    • /
    • 2004
  • Ozone gas is one of the strongest oxidizing and bleaching agents which leave no residues harmful to the global environment. In recent years, the ozone generator has been widely utilized, However, it has been known that a broader application of ozone is hindered primarily because of its low efficiency of generation. Thus, it is more indispensable to improve actual system efficiency of the silent discharge type ozonizer using high frequency inverter. This paper presents a multi level resonant ozone power regulation by association of high frequency transformers and full bridge invert. And proposed resonant inverter system can generate continuous output voltage. can control linearly quantity of ozone gas. This invert that add PWM forms within square forms of output voltage about one level range. The power regulation characteristics and operating performances of silent discharge (SD)type ozone generating tube load driven by this load proposed inverter using FET modules are illustrated from a practical point of view, which can operate under stable conditions of basic level and PWM hybrid control strategy implemented DSP(2406). The effectoveness of propsed invert type ozonizer is proved by experiment results.

  • PDF

3레벨 인버터로 구동되는 IPMSM의 고주파 주입 센서리스 운전에서 중성점 전압 리플 저감 (Neutral-Point Voltage Ripple Reduction of High Frequency Injection Sensorless Control of IPMSM Fed by a Three-Level Inverter)

  • 조대현;김석민;이교범
    • 전기전자학회논문지
    • /
    • 제24권3호
    • /
    • pp.867-876
    • /
    • 2020
  • 본 논문에서는 3레벨 인버터로 구동되는 IPMSM의 고주파 주입 센서리스 운전에서 중성점 전압 리플 저감을 제안한다. 고주파 전압 주입 기반의 센서리스 제어는 IPMSM의 저속 영역에서 일반적으로 사용하는 센서리스 제어 기법이다. 고주파 전압 주입을 이용한 IPMSM의 센서리스 제어 과정에서 중성점에서의 전압 리플이 증가하는 문제가 발생한다. 중성점에서의 큰 전압 리플은 출력 전류를 왜곡시킬 뿐만 아니라 직류단 커패시터의 수명을 단축시키므로 저감되어야 한다. 본 논문에서 제안하는 기법은 지령 전압에 적절한 값을 보상하여 중성점 전압 리플을 저감하며, 보상값은 지령 전압과 전류를 이용하여 간단히 계산한다. 제안하는 중성점 전압 리플 저감 기법의 타당성은 시뮬레이션을 통해 검증한다.

가변속 유도 전동기를 구동하기 위한 PWM인버터의 새로운 변조 방식 (A Novel Modulation Techniques for Driving a Variable-Speed Induction Motor)

  • 윤병도;전희종;김국진;정율기;손진근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.600-604
    • /
    • 1991
  • In this paper, an advanced PWM modulation strategy for driving a variable-speed induction motor is introduced. According to this method, the technique of efficiently eliminating harmonics component is achived. A switching pattern was computed making use of the near-proportionality of voltage and frequency in AC machines operating with constant flux. At low magnitudes and low frequencies of the foundamental, many more harmonics are eliminated than at high magnitudes and frequencies. In order to keep the inverter switching frequency constant over the output frequency range, chopping times diminishes as the frequency of the fundamental increases.

  • PDF

마이크로 프로세서를 이용한 전자식 안정기 설계 (Design of a Electronic Ballast using Microprocessor)

  • 이창훈
    • 조명전기설비학회논문지
    • /
    • 제21권5호
    • /
    • pp.44-52
    • /
    • 2007
  • 본 논문에서는 저가형 마이크로 프로세서를 이용한 형광등용 안정기의 인버터 구동회로를 설계하였다. 인버터 안정기의 고속 절체 주파수에 따른 스위칭 손실 및 모멘트 저하를 방지하기 위하여 소프트 스타트 기법이 사용되었으며, 설계된 전자식 안정기는 PWM 제어를 통한 스위칭 펄스의 안정화를 통해 안정기의 안정도 향상 및 형광등의 조도특성 개선이 가능하였다.

보급형 인버터식 X선발생장치의 특성에 관한 연구 (A Study on the Characteristics of Inverter Type X-Ray Genertator)

  • 박수강
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.26-29
    • /
    • 2000
  • The conventional types of X-ray generators were bulky in physical size and heavy in weight and the control accuracies of the output voltages were not always satisfacotry. The high frequency switching inverter and converter technology on power conversion and control systems have been greatly closed up introducing power semiconducot devices. To decreasing the volume and the weight of high voltage transformer and to stabilize ripple. In this paper the newly developed x-ray generator in a low cost using duty modulation PWM inverter. This system verify improved performance by stabilize ripple of X-ray tube voltage and compared the reproducibility linearity and dose in single phase three phase and PSU.

  • PDF