• Title/Summary/Keyword: low frequencies

Search Result 1,470, Processing Time 0.028 seconds

Adaptive Response Induced by Low Dose Ionizing Raditation in Human Cervical Carcinoma Cells

  • Kim, Jeong -Hee;Lee, Kyung -Jong;Cho, Chul -Koo;Yoo, Seong -Yul;Kim, Tae -Hwan;Ji, Young -Hoon;Kim, Sung -Ho
    • Archives of Pharmacal Research
    • /
    • 제18권6호
    • /
    • pp.410-414
    • /
    • 1995
  • Adaptive response induced by low dese .gamma.-ray irradiation in human cervical carcinoma cells was examined. Cells were exposured to low dose of .gamma.-ray irradiation in human cervical carcinoma cells was examined. Cells were exposured to low dose of .gamma.-ray (1-cGy) followed by high doses of r-ray irradiation (0,1,2,3,5,7 and 9Gy for chlnogenic assay or 1.5Gy for micronucleus assay) with various time intervals. Survival fractions of cells in both low dose-irradiated and unirrated groups were analyzed by clonogenic assay. Surviva fractions of low dose-irradiated in cell survival was maximum when low and high dose irradiation time interval was 4 hr. Frequencies of micronuclei which is an indicative of chromosome aberration were also enutained from survival fractions analyzed by clonogenic assay, maximum when low and high dose irradiation time interval was 4hr. Frequencies of micronuclei which is an indicative of chromosome aberration were also enumerated in both low dose-irradiated and unirradiated groups. In consiststent with the result obtained from survival fractions analyzed by clonogenic assay, maximum reduction in frquencies of micronuclei was observed when low dose radiation was given 4 hr prior to high response to subsequent high dose .gamma.-ray irradiation in human cervical carcinomal cells. Our data suggest that one of the possible mechanisms of adaptive response induced by low dose rediation is the increase in repair of DNA double strand breaks in low dose radiation-adapted cells.

  • PDF

성인여성 기성복의 치수 간격설정에 관한 연구 (A study on the apparel sizing system of adult women)

  • 이진희;최혜선;박수찬;김진호
    • 대한인간공학회지
    • /
    • 제13권1호
    • /
    • pp.59-74
    • /
    • 1994
  • The purposes of this paper were to suggest the procedures for a sizing sys- tem which can provide good fitting of apparel and minimize the loss due to excessive inventory, and to determine an adequate apparel sizing standard. An anthropometric database used for this study was the 1992 National Anthro- pometric Survey of Koreans. The database was limited to 1,336 women who were 18-51 years old. They study was conducted by classifying ages into two groups (18-33, 34-51) using Wilk's lamda. Three principal components : laterality( fullness), linearity(length) and characteristic of torso were selected to describe body types, and these three body type classification of each group were selected by cluster analysis. It was found that all intervals between standard sizes were not equal. They were narrow around the center with high frequencies of the customers but wide in both tail with low frequencies. It was also found that the optimal sizes suing the loss function can be applied well in practice.

  • PDF

수직 및 랜덤입사 흡음률에 관한 연구 (Study on Normal and Random incidence Absorption Coefficient)

  • 강현주;김봉기;김상렬
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2000년도 하계학술발표대회 논문집 제19권 1호
    • /
    • pp.283-286
    • /
    • 2000
  • 흡음률을 예측 및 평가하기 위한 연구로서 우선 수직입사 흡음률을 예측하는 경험식 모델에 대한 비교 연구를 수행하였다. 비교결과는 Voronina 가 제안한 경험식이 상대적으로 실험치와 잘 일치하고 있다. 한편 수직입사와 랜덤입사와의 상관관계를 실험 연구를 통하여 조사하였다. 이 상관관계는 주파수에 따라서 다르게 나타나고 있다. 저주파수 대역에서는 랜덤 입사가 수직입사 보다 크게 나타나고 있지만 고주파수에서는 수평입사 성분의 영향으로 랜덤입사에서는 감소하는 경향을 보이고 있다.

  • PDF

주파수 대역 제한에 의한 한국어 모음의 지각 특성 분석 (Perceptual Characteristics of Korean Vowels Distorted by the Frequency Band Limitation)

  • 김연화;최대림;이숙향;이용주
    • 말소리와 음성과학
    • /
    • 제6권1호
    • /
    • pp.85-93
    • /
    • 2014
  • This paper investigated the effects of frequency band limitation on perceptual characteristics of Korean vowels. Monosyllabic speech (144 syllables of CV type, 56 syllables of VC type, 8 syllables of V type) produced by two announcers were low- and high-pass filtered with cutoff frequencies ranging from 300 to 5000 Hz. Six listeners with normal hearing performed perception tests by types of filter and cutoff frequencies. We reported phoneme recognition rates and types of perception error of band-limited Korean vowels to examine how frequency distortion in the process of speech transmission affect listener's perception.

변화하는 감쇠를 갖는 계가 조화력을 받을 때의 운동 - 이론적 해석 (Motion of a System with Varying Damping Subject to Harmonic Force - Analytical Analysis)

  • 박오철;이건명
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.898-902
    • /
    • 2006
  • The motion of a system composed of a plate, constant springs and varying dampers is considered when the system is subject to harmonic force. Letting the frequencies of harmonic force and damper variation ${\Large f}_1\;and\;{\Large f}_2$ respectively, the displacement at the center of the plate has the strongest component at frequency ${\Large f}_1$. The angular displacement of the plate has strong components at ${\Large f}_1-{\Large f}_2$ and the natural frequency of the rotational mode of the system. If these two frequencies coincide, the plate oscillates with almost single frequency and a large amplitude. Part of these simulation results are proved analytically.

  • PDF

날개짓 비행체의 양력 변위 (Lift Force Variation of Flapping Wing)

  • 홍영선
    • 한국군사과학기술학회지
    • /
    • 제10권1호
    • /
    • pp.33-43
    • /
    • 2007
  • Using the more common conventional chordwise aerodynamic approach, flapping a flat plate wing with zero degree chordwise pitch angle of attack and no relative wind should not produce lift. However, in hover, with no forward relative velocity and zero degree chordwise pitch angle of attack, flapping flat plate wings does in fact produce lift. In the experiments peformed for this paper, the flapping motion is considered pure(downstroke and upstroke) with no flapping stroke plane inclination angle. No changes in chordwise pitch angle are made. The total force is measured using a force transducer and the net aerodynamic force is determined from this measured total force by subtracting the experimentally determined inertial contribution. These experiments were repeated at various flapping frequencies and for various wing planform sizes for flat plate wings. The trends in the aerodynamic lift variation found using a force transducer have nearly identical shape for various flapping frequencies and wing planform sizes.

Spatial Luminance Contrast Sensitivity: Effects of Surround

  • Kim, Youn-Jin;Kim, Hong-Suk
    • Journal of the Optical Society of Korea
    • /
    • 제14권2호
    • /
    • pp.152-162
    • /
    • 2010
  • This study examined the effects of surround luminance on the shape of the spatial luminance contrast sensitivity function (CSF). The reduction in brightness of uniform neutral patches shown on a computer controlled display screen is also assessed to explain the change of CSF shape. Consequently, a large amount of reduction in contrast sensitivity at middle spatial frequencies can be observed; however, the reduction is relatively small for low spatial frequencies. In general, the effect of surround luminance on the CSF appears similar to that of mean luminance. Reduced CSF responses result in less power of the filtered image; therefore, the stimulus should appear dimmer with a higher surround luminance.

한국인 집단에서 Cytochrome P450 2E1의 유전적 다형성 (Genetic Polymorphism of Cytochrome P450 2E1 in Korean Population)

  • 정혜광;구희경;이상섭;양규환;정태천;변부형
    • 한국환경성돌연변이발암원학회지
    • /
    • 제16권2호
    • /
    • pp.97-102
    • /
    • 1996
  • In this study, we have quantified genotype frequency of the cytochrome P450 (P450) 2E1 which codes for the P450 enzyme primarily responsible for the metabolic activation of carcinogenic nitrosamines and low molecular organic solvents, in Korean population by using PCR and RFLP at two sites previously associated with some cancers; a PstI and RsaI RFLP in the transcriptional regulatory region of the human P450 2E1 gene. The genotype frequencies of homozygous wild type (PstI site-absent) and heterozygous mutant type (PstI site-present) in PstI RFLP were 0.70 and 030, respectively. The homozygous mutant type in Pstl RFLP was not observed in Korean population. The genotype frequencies of homozygous wild type (RsaI site-present), heterozygous mutant type (RsaI site-absent), and homozygous mutant type in RsaI RFLP were 0.71, 0.26, and 0.03, respectively.

  • PDF

열전변환장치 다이오드 전극간의 플라즈마 불안정성에 관한 연구 (A STUDY OF PLASMA INSTABILITY IN A CESIATED THERMIONIC DIODE)

  • 이득용;이민구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1247-1249
    • /
    • 1992
  • Oscillations with radio-frequencies are observed in a cesiated variable spacing thermionic diode having a parallel-plane geometry under certain conditions. The emitter is operated over the temperature range from 1300 to 2000 K and collector from 300 to 1050 K. The cesium vapor pressures are in the range of $10^{-3}$ to 3 torr. The interelectrode gap is between 1 mm to 0.08 mm. The oscillations are only observed in two nonoverlapping regimes. The low temperature oscillations (1300 to 1550 K) are inversely proportional to both the cesium vapor pressure and the square of the interelectrode gap. The high temperature oscillations is inversely proportional to the interelectrode gap. However, all these observed oscillations are frequencies of the plasma ion oscillation.

  • PDF

자기부상열차용 인버터 및 컨버터 소음에 관한 연구 (A Study of Maglev Train Inverter and Converter Noise)

  • 김현실;김재승;강현주;김봉기;김상렬
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.346-351
    • /
    • 2002
  • Noise of the VVVF inverter and DC/DC converter, which are the most dominant noise sources of maglev train at low speed, is studied, The coils inside inverter and converter are excited by electro-magnetic forces, which results in core vibration and generations of the noise. It is found that the spectra of the noise show many harmonics, where there exist several different fundamental frequencies. Some noise reducing techniques are known for the transformer noise such as changing stiffness and using different core materials, which make less electrostatic responses, and consequently less noise. In this study, it is shown that the most effective and feasible noise reducing method is to increase the switching frequencies of the inverter and converter, where peaks in higher frequency are significantly reduced.

  • PDF