• 제목/요약/키워드: low doses

검색결과 747건 처리시간 0.024초

Differential Expression of Th1- and Th2- Type Cytokines in Peripheral Blood Mononuclear Cells of Murrah Buffalo (Bubalus Bubalis) on TLR2 Induction by B. Subtilis Peptidoglycan

  • Shah, Syed M.;Ravi Kumar, G.V.P.P.S.;Brah, G.S.;Santra, Lakshman;Pawar, Hitesh
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제25권7호
    • /
    • pp.1021-1028
    • /
    • 2012
  • Peripheral blood mononuclear cells (PBMCs) discriminate microbial pathogens and induce T-cell responses of appropriate effector phenotype accordingly. Toll-like receptors (TLRs), in part, mediate this microbial recognition and differentiation while the development of T-cell effector functions critically depends on the release of Th1- or Th2- type cytokines. In the present study, buffalo PBMCs were stimulated under in vitro culture conditions by Bacillus subtilis cell wall petidoglycan, a TLR2 ligand, in a dose- and time- dependent manner. The expression of TLR2 as well as the subsequent differential induction of the Th1 and Th2 type cytokines was measured. Stimulation was analyzed across five doses of peptidoglycan ($10{\mu}g/ml$, $20{\mu}g/ml$, $30{\mu}g/ml$, $40{\mu}g/ml$ and $50{\mu}g/ml$) for 3 h, 12 h, 24 h and 36 h incubation periods. We observed the induction of TLR2 expression in a dose- and time-dependent manner and the peptidoglycan induced tolerance beyond $30{\mu}g/ml$ dose at all incubation periods. The correlation between peptidoglycan stimulation and TLR2 induction was found positive at all doses and for all incubation periods. Increased production of all the cytokines was observed at low doses for 3 h incubation, but the expression of IL-4 was relatively higher than IL-12 at the higher antigen doses, indicating tailoring towards Th2 response. At 12 h incubation, there was a pronounced decrease in IL-4 and IL-10 expression relative to IL-12 in a dose- dependent manner, indicating skewing to Th1 polarization. The expression of IL-12 was highest for all doses across all the incubation intervals at 24 h incubation, indicating Th1 polarization. The relative expression of TNF-${\alpha}$ and IFN-${\gamma}$ was also higher while that of IL-4 and IL-10 showed a decrease. For 36 h incubation, at low doses, relative increase in the expression of IL-4 and IL-10 was observed which decreased at higher doses, as did the expression of all other cytokines. The exhaustion of cytokine production at 36 h indicated that PBMCs became refractory to further stimulation. It can be concluded from this study that the cytokine response to sPGN initially was of Th2 type which skews, more pronouncedly, to Th1 type with time till the cells become refractory to further stimulation.

Surface modification and induced ultra high surface hardness by nitrogen ion implantation of low alloy steel

  • Olofinjana, A.O.;Bell, J.M.;Chen, Z.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.157-158
    • /
    • 2002
  • A surface hardenable low alloy carbon steel was implanted with medium energy (20 - 50KeV) $N_2^+$ ions to produced a modified hardened surface. The implantation conditions were varied and are given in several doses. The surface hardness of treated and untreated steels were measured using depth sensing ultra micro indentation system (UMIS). It is shown that the hardness of nitrogen ion implanted steels varied from 20 to 50GPa depending on the implantation conditions and the doses of implantation. The structure of the modified surfaces was examined by X-ray photoelectron spectroscopy (XPS). It was found that the high hardness on the implanted surfaces was as a result of formation of non-equilibrium nitrides. High-resolution XPS studies indicated that the nitride formers were essentially C and Si from the alloy steel. The result suggests that the ion implantation provided the conditions for a preferential formation of C and Si nitrides. The combination of evidences from nano-indentation and XPS, provided a strong evidence for the existence of $sp^3$ type of bonding in a suspected $(C,Si)_xN_y$ stoichiometry. The formation of ultra hard surface from relatively cheap low alloy steel has significant implication for wear resistance implanted low alloy steels.

  • PDF

전악치근단방사선사진촬영, 파노라마방사선사진촬영 및 협각단층촬영시의 흡수선량 (Absorbed Dose in the Full-mouth Periapical Radiography, Panoramic Radiography, and Zonography)

  • 최순철;최항문
    • 치과방사선
    • /
    • 제29권1호
    • /
    • pp.255-260
    • /
    • 1999
  • Purpose: The objective of this study was to evaluate the possibility of substitution of the zonography for the full-mouth periapical radiography in aspect of radiation protection. Materials and Methods: Rando phantom and LiF TLD chips were used for dosimetry. The absorbed doses at brain, skin above the TMJ. parotid gland. bone marrow in the mandibular body. and thyroid gland during the full-mouth periapical radiography. panoramic radiography. and zonography were measured. Resul ts: From the zonography. the absorbed doses to the brain. the skin over the TMJ. and the parotid gland were relatively high. but the absorbed doses to the bone marrow in the mandibular body and. especially. the thyroid gland were very low. Conclusion: The zonography can be an alternative to the full-mouth periapical radiography in aspect of radiation protection.

  • PDF

High Dose $^{60}Co\;{\gamma}$-Ray Irradiation of W/GaN Schottky Diodes

  • Kim, Jihyun;Ren, F.;Schoenfeld, D.;Pearton, S.J.;Baca, A.G.;Briggs, R.D.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제4권2호
    • /
    • pp.124-127
    • /
    • 2004
  • W/n-GaN Schottky diodes were irradiated with $^{60}Co\;{\gamma}-rays$ to doses up to 315Mrad. The barrier height obtained from current-voltage (I-V) measurements showed minimal change from its estimated initial value of ${\sim}0.4eV$ over this dose range, though both forward and reverse I-V characteristics show evidence of defect center introduction at doses as low as 150 Mrad. Post irradiation annealing at $500^{\circ}C$ increased the reverse leakage current, suggesting migration and complexing of defects. The W/GaN interface is stable to high dose of ${\gamma}-rays$, but Au/Ti overlayers employed for reducing contact sheet resistance suffer from adhesion problems at the highest doses.

Quantitative and Qualitative Extrapolation of Carcinogenesis Between Species

  • Gold Lois Swirsky;Manley Neela B.;Ames Bruce N.
    • 대한예방의학회:학술대회논문집
    • /
    • 대한예방의학회 1994년도 교수 연수회(환경)
    • /
    • pp.431-438
    • /
    • 1994
  • As currently conducted, standard rodent bioassays do not provide sufficient information to assess carcinogenic risk to humans at doses thousands of times below the maximum tolerated dose. Recent analyses indicate that measures of carcinogenic potency from these tests are restricted to a narrow range about the maximum tolerated dose and that information on shape of the dose-response is limited in experiments with only two doses and a control. Extrapolation from high to low doses should be based on an understanding of the mechanisms of carcinogenesis. We have postulated that administration of the maximum tolerated dose can increase mitogenesis which, in turn. increases rates of mutagenesis and, thus, carcinogenesis. The animal data are consistent with this mechanism, because about half of all chemicals tested are indeed rodent carcinogens, and about 40% of the positives are not detectably mutagenic. Thus, at low doses where cell killing does not occur, the hazards to humans of rodent carcinogens may be much lower than commonly assumed. In contrast, for high-dose exposures in the workplace, assessment of hazard requires comparatively little extrapolation. Nevertheless. permitted workplace exposures are sometimes close to the tumorigenic dose-rate in animal tests. Regulatory policy to prevent human cancer has primarily addressed synthetic chemicals, yet similar proportions of natural chemicals and synthetic chemicals test positive in rodent studies as expected from an understanding of toxicological defenses, and the vast proportion of human exposures are to natural chemicals. Thus, human exposures to rodent carcinogens are common. The natural chemicals are the control to evaluate regulatory strategies, and the possible hazards from synthetic chemicals should be compared to the possible hazards from natural chemicals. Qualitative extrapolation of the carcinogenic response between species has been investigated by comparing two closely related species: rats and mice. Overall predictive values provide moderate confidence in interspecies extrapolation; however, knowing that a chemical is positive at any site in one species gives only about a 50% chance that it will be positive at the same site in the other species.

  • PDF

후방산란(後方散亂)과 노출배수(露出倍數)에 관(關)한 검토(檢討) (Observation of Back Scattering and Exposure-Factors)

  • 허준;김창균;강홍석;이선숙;이좌룡;윤철호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제5권1호
    • /
    • pp.15-19
    • /
    • 1982
  • Authors made an experiment to know the relation of surface doses and multiple factors of exposure by using grids, fields, tube voltages objects and distances and obtained the results as follows: 1. Surface doses were increased in proportion to the thickness of objects. 2. Surface doses were more influenced when irradiated fields were small and tube voltages were low. 3. Surface doses were a logarthmic proportion to the focus-object distance. 4. Multiple factors of exposure by using grid were under the control of the thickness of objects, irradiated fields and tube voltages but the relation of them were not fixed.

  • PDF

Radon and thoron concentrations inside ancient Egyptian tombs at Saqqara region: Time-resolved and seasonal variation measurements

  • Salama, E.;Ehab, M.;Ruhm, W.
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.950-956
    • /
    • 2018
  • For complete assessment of inhalation doses of radon and its progeny inside the three main ancient Egyptian tombs in Saqqara, seasonal radon concentrations have been measured by using a new electronic device that allows for measurement of real-time-resolved radon concentrations. Measurements were complemented by very fast measurements of thoron concentrations, which turned out to be low. Based on these measurements, annual residence time inside these tombs and the newest International Commission on Radiological Protection-recommended radon dose conversion coefficients or seasonal effective doses were calculated. The results indicate that workers receive highest annual effective doses of up to 140 mSv, which exceeds the annual limit of 20 mSv, whereas lower values up to 15 mSv are received by guides. In contrast, much lower doses were obtained for one-time visitors of the investigated tombs. The obtained results are somewhat different but still consistent with those previously obtained by means of fixed passive dose meters at some of the investigated places. This indicates that reasonable estimates of the effective dose of radon can be also obtained from short-term radon measurements carried out only twice a year (summer and winter season). Increasing the ventilation, minimizing the working times, etc., are highly recommended to reduce the annual effective dose.

파노라마 촬영시 두경부 주요기관에 대한 흡수선량 분포 (DISTRIBUTION OF ABSORBED DOSES TO THE IMPORTANT ORGANS OF HEAD AND NECK REGION IN PANORAMIC RADIOGRAPHY)

  • 김병삼;최갑식;김진수
    • 치과방사선
    • /
    • 제20권2호
    • /
    • pp.253-264
    • /
    • 1990
  • PanelipseⅡ 파노라마 방사선사진 촬영시 두 경부 주요기관의 방사선 흡수선량 분포를 평가하기 위하여 LiF(TLD-100/sup R/) 열발광선량계를 phantom (RT-210 Humanoid Head & Neck Section/sup R/)내부의 중요 해부구조물과 피부표면에 위치시켜 관전류 4㎃와 노출시간 20초의 조건하에서 관전압변화(65kVp. 75kVp, 85kVp)에 따른 방사선 흡수선량을 측정하여 아래와 같은 결론을 얻었다. 내부해부구조물의 방사선 흡수선량은 비인강부위에서 104mGy, 1.065mGy, 2.09mGy로써 가장 높게 나타났고 이하선의 내엽부위에서는 0.525mGy, 0.579mGy, 1.108mGy로, 악하선부위에서는 0.481mGy, 0.608mGy, 1.191mGy로 비교적 높게 나타났으며 85kVp에서만 흡수선량이 측정된 안구와 갑상선부위는 0.172mGy와 0.128mGy로써 비교적 낮게 나타났다. 피부표면의 방사선 흡수선량은 제1경추 후방부위에서 1.263mGy, 1.538mGy, 2.952mGy로써 가장 높게 나타났고 이하선부위에서는 0.267mGy, 0.401mGy, 0.481mGy로 비교적 높게 나타났으며 인중부위는 0.057mGy, 0.068mGy, 0.081mGy, 85kVp에서만 흡수선량이 측정된 턱의 중앙부위는 0.059mGy로써 비교적 낮게 나타났다. 관전압 증가에 따른 내부해부구조물의 방사선 흡수선량 증가는 65kVp에서 75kVp로 증가함에 따라 1.1배로 나타났으며, 76kVp에서 85kVp로 증가시에는 1.9배로 나타났다. 관전압 증가에 따른 피부표면의 방사선 흡수선량 증가는 65kVp에서 75kVp로 증가함에 따라 1.3배로 나타났으며, 75kVp에서 85kVp로 증가시에는 1.6배로 나타났다.

  • PDF

Safety Assessment for the Landfill Disposal of Decommissioning Waste Solidified by Magnesium Potassium Phosphate Cement

  • Jeong, Jongtae;Baik, Min-Hoon;Lee, Jae-Kwang;Pyo, Jae-Young;Um, Wooyong;Heo, Jong
    • 방사성폐기물학회지
    • /
    • 제20권1호
    • /
    • pp.13-22
    • /
    • 2022
  • The decommissioning of a nuclear power plant generates large amounts of radioactive waste, which is of several types. Radioactive concrete powder is classified as low-level waste, which can be disposed of in a landfill. However, its safe disposal in a landfill requires that it be immobilized by solidification using cement. Herein, a safety assessment on the disposal of solidified radioactive concrete powder waste in a conceptual landfill site is performed using RESRAD. Furthermore, sensitivity analyses of certain selected input parameters are conducted to investigate their impact on exposure doses. The exposure doses are estimated, and the relative impact of each pathway on them during the disposal of this waste is assessed. The results of this study can be used to obtain information for designing a landfill site for the safe disposal of low-level radioactive waste generated from the decommissioning of a nuclear power plant.

Analysis for the secondary gamma-ray emission for glasses irradiated with various doses of fast neutron: Case study borate and silicate glasses

  • O.L. Tashlykov;V. Yu. Litovchenko;N.M. Aristov;K.A. Mahmoud
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2366-2372
    • /
    • 2023
  • Are borate and silicate glasses suitable for working as shieling materials against fast neutrons? To correctly answer the above question, some silicate, and borate-based glasses were fabricated and irradiated with various doses of fast neutrons varied between 1.73 and 12.10 MGy. The color and hardness of the fabricated glasses were affected by the fast neutron fluence where the transparent glasses turned colored as well as the hardness of the fabricated glasses was decreased. The gamma-ray spectrometric analysis shows a high activity concentration produced in the barium borate glasses due to the formation of radioisotopes Ba-131 and Ba-133 reaches to 5.92E+05 Bq and 4.25E+03 Bq, respectively for sample Cd-5 Batch 3. Additionally, the gamma-ray spectrometric analysis for the sodium silicate glasses shows low activity concentrations emitted from isotopes formed due to the activation of Y2O3-associated impurities. These activities are low compared to that emitted by barium borate-based glasses.