• Title/Summary/Keyword: low dose effect

Search Result 1,026, Processing Time 0.032 seconds

A Study on the Breakdown Voltage Characteristics with Process and Design Parameters in Trench Gate IGBT (트렌치 게이트 IGBT 에서의 공정 및 설계 파라미터에 따른 항복 전압 특성에 관한 연구)

  • Shin, Ho-Hyun;Lee, Han-Sin;Sung, Man-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.5
    • /
    • pp.403-409
    • /
    • 2007
  • In this paper, effects of the trench angle($\theta$) on the breakdown voltage according to the process parameters of p-base region and doping concentrations of n-drift region in a Trench Gate IGBT (TIGBT) device were analyzed by computer simulation. Processes parameters used by variables are diffusion temperature, implant dose of p-base region and doping concentration of n-drift region, and aspects of breakdown voltage change with change of each parameter were examined. As diffusion temperature of the p-base region increases, depth of the p-base region increases and effect of the diffusion temperature on the breakdown voltage is very low in the case of small trench angle($45\;^{\circ}$) but that is increases 134.8 % in the case of high trench angle($90\;^{\circ}$). Moreover, as implant dose of the p-base region increases, doping concentration of the p-base region increases and effect of the implant dose on the breakdown voltage is very low in the case of small trench angle($45\;^{\circ}$) but that is increases 232.1 % in the case of high trench angle($90\;^{\circ}$). These phenomenons is why electric field concentrated in the trench is distributed to the p-base region as the diffusion temperature and implant dose of the p-base increase. However, effect of the doping concentration variation in the n-drift region on the breakdown voltage varies just 9.3 % as trench angle increases from $45\;^{\circ}$ to $90\;^{\circ}$. This is why magnitude of electric field concentrated in the trench changes, but direction of that doesn't change. In this paper, respective reasons were analyzed through the electric field concentration analysis by computer simulation.

Scattering Measurement of Syringe Shield Used in PET/CT (PET/CT실에서 사용되는 주사기 차폐체의 산란선 측정)

  • Jang, Dong-Gun;Park, Cheol-Woo;Park, Eun-Tae
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.375-382
    • /
    • 2020
  • PET/CT is a medical equipment that detects 0.511 MeV of gamma rays. The radiation workers are inevitably exposed to ionizing radiation in the process of handling the isotope. Accordingly, PET/CT workers use syringe shields made of lead and tungsten to protect their hands. However, lead and tungsten are known to generate very high scattering particles by interacting with gamma rays. Therefore, in this study, we tried to find out the effect on the scattering particles emitted from the syringe shield. In the experiment, first, the exposure dose to the hand (Rod phantom) was evaluated according to the metal material (lead, tungsten, iron, stainless steel) using Monte Carlo simulation. The exposure dose was compared according to whether or not plastic is attached. Second, the exposure dose of scattering particles was measured using a dosimeter and lead. As a result of the experiment, the shielding rate of plastics using the Monte Carlo simulation showed the largest difference in dose of about 40 % in lead, and the lowest in iron, about 15 %. As a result of the dosimeter test, when the plastic tape was wound on lead, it was found that the reduction rate was about 15 %, 28 %, and 39 % depending on the thickness. Based on the above results, it was found that 0.511 MeV of gamma ray interacts with the shielding tool to emit scattered rays and has a very large effect on radiation exposure. However, it was considered that the scattering particles could be sufficiently removed with plastics with a low atomic number. From now on, when using high-energy radiation, the shielding tool and the skin should not be in direct contact, and should be covered with a material with a low atomic number.

Stimulation Effect of Early Growth in Crops by Low Dose Radiation (저선량 방사선에 의한 작물 초기생육 촉진효과)

  • Kim, Jae-Sung;Song, Hi-Sup;Kim, Jin-Kyu;Lee, Young-Keun;Lee, Young-Bok
    • Korean Journal of Environmental Agriculture
    • /
    • v.17 no.2
    • /
    • pp.156-159
    • /
    • 1998
  • Germination rate and early growth in crop such as rice,soybean,and perilla were observed after irradiation of $^{\gamma}$-ray (Co-60) in order to determine the effects of low does radiation. The low dose radiation was able to improve the early growth in crops and their agricultural charaters. Germination rate of 2Gy-irradiatied rice seeds was high and also were seeding height and fresh weight of the 0.5 Gy-irradiated. Germination rate and early growth of soybean were high in 4Gy-irradiated group. Perilla gew ot so promisingly after after low dose irradiation,however there slightly increasing effects on germination rate, seeding height and fresh weightat 2Gt-, 1Gy-, and 1Gy irradiated group, respectively.

  • PDF

Current Status of High Dose Rate Brachytherapy in Cervical Cancer in Korea and Optimal Treatment Schedule (자궁 경부암 고선량율 강내조사 치료의 국내 현황과 적정 치료방법)

  • Huh, Seung-Jae
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.357-366
    • /
    • 1998
  • Brachytherapy is an essential part of radiotherapy for uterine cervical cancer. The low dose rate (LDR) regimen has been the major technique of intracavitary therapy for cervical cancer. However, there has been an expansion in the last 20 years of high dose rate (HDR) machines using Ir-192 sources. Since 1979, HDR brachytherapy has been used for the treatment of uterine cervical cancer in Korea. The number of institutions employing HDR has been increasing, while the number of low dose rate system has been constant. In 1995, there was a total 27 HDR brachytherapy units installed and 1258 cases of patients with cervical cancer were treated with HDR Most common regimens of HDR brachytherapy are total dose of 30-39 Gy at point A with 10-13 fractions in three fractions per week. 24-32 Gy with 6-8 fractions in two fractions per week, and 30-35 Gy with 6-7 fractions in two fractions per week. The average fractionation regimen of HDR brachytherapy is about 8 fractions of 4.1 Gy each to Point A. In Korea, treatment results for HDR brachytherapy are comparable with the LDR series and appears to be a safe and effective alternative to LDR therapy for the treatment of cervical carcinoma. Studies from the major centers report the five-year survival rate of cervical cancer as. 78-86$\%$ for Stage 1, 68-85$\%$ for stage 11, and 38-56$\%$ for Stage III. World-wide questionnaire study and Japanese questionnaire survey of multiple institutions showed no survival difference in any stages and dose-rate effect ratio (HDR/LDR) was calculated to be 0.54 to 0.58. However the optimum treatment doses and fractionation schemes appropriate to generate clinical results comparable to conventional LDR schemes have yet to be standardized. In conclusion, HDR intracavitary radiotherapy is increasingly practiced in Korea and an effective treatment modality for cervical cancer. To determine the optimum radiotherapy dose and fractionation schedule, a nation-wide prospective study is necessary in Korea. In addition, standardization of HDR application (clinical, computer algorithms, and dosimetric aspects) is necessary.

  • PDF

Disturbing Effects of Chronic Low-dose 4-Nonylphenol exposing on Gonadal Weight and Reproductive Outcome over One-generation

  • Cha, Sunyeong;Baek, Jeong Won;Ji, Hye Jin;Choi, Jun Hee;Kim, Chaelim;Lee, Min Young;Hwang, Yeon Jeong;Yang, Eunhyeok;Lee, Sung-Ho;Jung, Hyo-il;Cheon, Yong-Pil
    • Development and Reproduction
    • /
    • v.21 no.2
    • /
    • pp.121-130
    • /
    • 2017
  • 4-Nonylphenol (NP) is a surfactant that is a well-known and widespread estrogenic endocrine disrupting chemical (EDC). Although it has been known that the affinity of NP to ERs is low, it has been suggested that low-dose NP has toxicity. In the present study, the endocrine disrupting effects on reproduction, and the weight of gonads, epididymis, and uterus were evaluated with the chronic lower-dose NP exposing. This study was designed by following the OECD test guideline 443 and subjected to a complete necropsy. In male, NP had an effect on the weight of the testis and epididymis in both $F_0$ and $F_1$. In females, NP decreased the weight of ovary and uterus in $F_0$ but not in pre-pubertal $F_1$ pubs. Fertility of male and female in $F_0$ or $F_1$ was no related with NP administration. The number of caudal-epididymal sperm by body weight (BW) was not different between groups in both $F_0$ and $F_1$. Besides, the difference of the sperm number between generations was not detected. The number of ovulated oocytes was similar between groups in $F_0$, but significantly decreased in NP 50 group of $F_1$. The litter size and sex ratios of offspring in $F_1$ and $F_2$ were not different. The accumulated mating rate and gestation period were not affected by the NP administration. Those results shows that chronic lower-dose NP administration has an effect of endocrine disruptor on the weight of gonads and epididymis of $F_0$ and $F_1$ but not in reproduction. Based on the results, it is suggested that chronic lower-dose NP exposing causes endocrine disruption in the weight of gonad and epididymis but not in the reproductive ability of next generations.

A Comparative Effect of Meperidine between Intravenous and Epidural Patient-Controlled Analgesia for the Postoperative Pain Relief after Cesarean Section (제왕절개 수술후 통증조절을 위해 PCA를 이용한 정맥과 경막외 Meperidine 투여효과의 비교)

  • Lee, Byung-Ho;Chea, Jun-Seuk;Chung, Mee-Young;Byun, Hyung-Jin
    • The Korean Journal of Pain
    • /
    • v.8 no.2
    • /
    • pp.257-265
    • /
    • 1995
  • Patient-Controlled Analgesia (PCA) has been widely used for postoperative pain relief. Meperidine is useful for PCA and has efficient analgesia, rapid onset, and low incidence of adverse effect. To compare the analgesic effect, total dose and hourly dose, side effect and neonatal status of breast feeding with meperidine via intravenous or epidural PCA for 48 hours after Cesarean Section, 40 parturient women undergoing elective Cesarean Section were randomly divided into two groups. Each respective group of 20 parturient women received meperidine via one of the intravenous PCA after general anesthesia with enflurane (IVPCA group) and the epidural PCA after general anesthesia with enflurane (IVPCA group) and the epidural PCA after epidural block with 2% lidocaine 20ml combined with general anesthesia with only $N_2O$ and $O_2$ (EpiPCA group) when they first complained of pain in recovery room. Following the administration of analgesic initial dose, parturient women of IVPCA group were allowed intravenous meperidine 10 mg every 8 minutes when they felt pain. The EpiPCA group received additional bolus dose of meperidine 2 mg and bupivacaine 0.7 mg were administered every 8 minutes as requested the patients with hourly continuous infusion of meperidine 4 mg and bupivacaine 1.4 mg. Data was collected during the 48 hours observation period including visual analog scale (VAS) pain scores, total meperidine dose, hourly dose during 48 hours and each time interval, incidence of adverse effect, satisfaction, and neonatal status with breast feeding. VAS pain scores of analgesic effect in EpiPCA group was significantly lower than in IVPCA group at 2 hours after the initial pain after Cesarean Section. Total dose and hourly dose of meperidine significantly reduced in EpiPCA group. Hourly dose of meperidine at each time interval significantly reduced during first 6 hours and from 12 hours to 24 hours in EpiPCA group. The side effects in IVPCA group were mainly sedation, nausea, and local irritation of skin. And EpiPCA group experienced numbness and itching. The degree of satisfaction of parturient women was 88.2 % in IVPCA group and 85.7 % in EpiPCA group. We did not observe any sedation, abnormal behavior, or seizure like activity in any neonates of breast feeding. From the above results we conclude that epidural PCA was more efficiently analgesic, less sedative, and consumptional, and safer for neonate than intravenous PCA, and could be an alternative method to intravenous PCA.

  • PDF

Determination of optimum gamma ray range for radiation mutagenesis and hormesis in quinoa (Chenopodium quinoa Willd.)

  • Park, Chan Young;Song, Seon Hwa;Sin, Jong Mu;Lee, Hyeon Young;Kim, Jin Baek;Shim, Sang In
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.240-240
    • /
    • 2017
  • Quinoa (Chenopodium quinoa Willd.) is one of the ancient crops cultivated in the Andes region at an altitude of 3,500-4000m in Chile and Bolivia from 5000 BC. It contains a large amount of protein, minerals and vitamins in comparison with other crops. The cultivation area has been increasing worldwide because of its excellent resistance to various abiotic stress such as salinity, drought and low temperature. ${\gamma}$-Ray radiation of high dose is often used as a tool to induce mutations in plant breeding, but it has a deleterious effect on organisms. However, the radiation may have a positive stimulatory effect of 'hormesis' in the low dose range. This experiment was carried out to investigate the optimum dose range for creating the quinoa genetic resources and to investigate the hormesis effect at low dose on the quinoa. This experiment was performed for 120 days from November, 2016 to February, 2017 in the greenhouse of Gyeongsang National University. ${\gamma}$-Ray radiation was irradiated to seeds at 0 Gy, 50 Gy, 100 Gy, 200 Gy, 300 Gy, 400 Gy, 600 Gy, 800 Gy and 1000 Gy for 8 hours. (50 Gy) using the low level radiation facility ($Co^{60}$) of Cooperative Research Institute of Radiation Research Institute, KAERI. Fifty seeds were placed on each petri dish lined with wet filter paper and germination rate was measured at a time interval of 2 hours for 40 hrs. The length of the root length was measured one week after germination. Each treatment was carried out in 3 replicates. The growth of seedlings were investigated for 10 days after transplanting of 30 day-old seedlings. The plant height, NDVI, SPAD, Fv/Fm, and panicle weight were measured. The germination rate was highest at 50Gy and 0Gy and the rate of seeds treated with 400Gy or higher rate decreased to 25% of the seeds treated with 50Gy. The emergence rate of seedling in pot experiment was higher at the dose of 200 Gy, 300 Gy and 400 Gy than at 0 and 50Gy. However, the rate was lower at strong radiation higher than 600Gy at which $1^{st}$ leaf was not expanded fully and dead due to extreme overgrowth at 44 days after treatment (DAT). The highest value of panicle weight was observed at 50Gy (6.15g) and 100Gy (5.57g). On the other hand, the weight at high irradiated dose of 300Gy and 400Gy was decreased by about 55% compared to low dose (50 Gy). NDVI measurement also showed the highest value at 50 Gy as the growth progressed. SPAD was the highest at 400 Gy and showed positive correlation with irradiation dose except 0 Gy. Fv/Fm was high at 50 Gy up to 30 DAT and no difference between treatments was observed except for 400 Gy from 44 DAT. The plant height was the highest in 50Gy during the growing period and was higher in the order of 50Dy, 100Gy, 0Gy, 200Gy, 300Gy and 400Gy in 88 DAT. In this experiment, the optimal radiation dose for hormesis was 50Gy and 100Gy, and the optimal radiation dose for mutagenesis seems to be 400 Gy.

  • PDF

The effect of photon energy on intensity-modulated radiation therapy (IMRT) plans for prostate cancer

  • Sung, Won-Mo;Park, Jong-Min;Choi, Chang-Heon;Ha, Sung-Whan;Ye, Sung-Joon
    • Radiation Oncology Journal
    • /
    • v.30 no.1
    • /
    • pp.27-35
    • /
    • 2012
  • Purpose: To evaluate the effect of common three photon energies (6-MV, 10-MV, and 15-MV) on intensity-modulated radiation therapy (IMRT) plans to treat prostate cancer patients. Materials and Methods: Twenty patients with prostate cancer treated locally to 81.0 Gy were retrospectively studied. 6-MV, 10-MV, and 15-MV IMRT plans for each patient were generated using suitable planning objectives, dose constraints, and 8-field setting. The plans were analyzed in terms of dose-volume histogram for the target coverage, dose conformity, organs at risk (OAR) sparing, and normal tissue integral dose. Results: Regardless of the energies chosen at the plans, the target coverage, conformity, and homogeneity of the plans were similar. However, there was a significant dose increase in rectal wall and femoral heads for 6-MV compared to those for 10-MV and 15-MV. The $V_{20Gy}$ of rectal wall with 6-MV, 10-MV, and 15-MV were 95.6%, 88.4%, and 89.4% while the mean dose to femoral heads were 31.7, 25.9, and 26.3 Gy, respectively. Integral doses to the normal tissues in higher energy (10-MV and 15-MV) plans were reduced by about 7%. Overall, integral doses in mid and low dose regions in 6-MV plans were increased by up to 13%. Conclusion: In this study, 10-MV prostate IMRT plans showed better OAR sparing and less integral doses than the 6-MV. The biological and clinical significance of this finding remains to be determined afterward, considering neutron dose contribution.

Tolerability and Effect of Early High-Dose Amino Acid Administration in Extremely Low Birth Weight Infants

  • Choi, Jin Wha;Kim, Jisook;Ahn, So Yoon;Chang, Yun Sil;Park, Won Soon;Sung, Se In
    • Neonatal Medicine
    • /
    • v.25 no.4
    • /
    • pp.153-160
    • /
    • 2018
  • Purpose: The aim of this study is to examine the tolerability and effect of early high-dose amino acid administration in extremely low birth weight infants (ELBWIs). Methods: This retrospective cohort study included ELBWI (birth weight <1,000 g, n=142). Biochemical, nutritional, and neurodevelopmental data were compared between infants who received conventional low amino acid (LAA; 1.5 g/kg/day) and those who received high amino acid (HAA; 3 g/kg/day) within the first 48 hours after birth. Neurodevelopmental data included weight, height, and head circumference at discharge, 12 to 14 and 18 to 24 months of corrected age and the Korean Bayley Scale of Infant Development II (K-BSID-II) score at 18 to 24 months of corrected age. Results: The HAA group demonstrated higher peak plasma albumin ($3.0{\pm}0.4$ vs. $3.2{\pm}0.5$, P<0.05) and lower serum creatinine ($1.7{\pm}0.9$ vs. $1.4{\pm}0.8$, P<0.05) during the first 14 days than the LAA group. Full enteral feeding was achieved significantly earlier in infants in the HAA group than in infants in the LAA group ($46.2{\pm}23.0days$ vs. $34.3{\pm}21days$, P<0.01). There was no difference between the two groups in the z score changes in all growth indicators from birth to discharge and at 12 to 14 and 18 to 24 months of corrected age, as well as in the K-BSID-II score at 18 to 24 months of corrected age. Conclusion: Aggressive administration of amino acids during the first 2 days of life in ELBWI was well tolerated and correlated with earlier full enteral feeding, but did not improve growth and neurodevelopment.

Dose-dependent UV Stabilization of p53 in Cultured Human Cells Undergoing Apoptosis Is Mediated by Poly(ADP-ribosyl)ation

  • Won, Jungyeon;Chung, So Young;Kim, Seung Beom;Byun, Boo Hyeong;Yoon, Yoo Sik;Joe, Cheol O.
    • Molecules and Cells
    • /
    • v.21 no.2
    • /
    • pp.218-223
    • /
    • 2006
  • The effect of poly(ADP-ribosyl)ation on the stability of p53 in SK-HEP1 cells treated with UV light was examined. Intracellular levels of p53 increased in cells treated with a low dose of UV light ($20J/m^2$), whereas they increased but then declined after a higher dose of UV ($100J/m^2$). Intracellular levels of p53 in the UV treated SK-HEP1 cells were dependent on the UV dose. Use of proteasome inhibitors revealed that p53 is degraded by proteasomal proteolysis after high doses of UV light. We present evidence that, at low doses, poly(ADP-ribose)polymerase (PARP) poly(ADP-ribosyl) ates p53 and protects it from proteasomal degradation before caspase-3 is activated, whereas at high doses the cells undergo UV induced apoptosis and PARP is cleaved by caspase-3 before it can protect p53 from degradation. Destabilization of p53 by cleavage of PARP may be important in cell fate decision favoring apoptosis.