Black Start and Synchronization of Microgrid Considering Distributed Generation Control (분산전원의 제어 특성을 고려한 마이크로그리드의 블랙 스타트 및 계통 동기화 전략)

  • Choi, Jin-Young;Won, Dong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.898-904
    • /
    • 2013
  • In order to minimize the damage from power outage, power system should be restored quickly. In this paper, a procedure for the restoration of microgrid is proposed. After elimination of the causes of power outage, a black start algorithm is executed by considering the characteristics of distributed generation control. After all resources have been recovered to the normal state, a grid reconnecting algorithm for stable operation in grid-connected mode is performed. In order to verify the proposed algorithm, low voltage microgrid is simulated using PSCAD/EMTDC.

Active Control Method of Heat-Duct Coupled Noise in a Cylindrical Combustor (원통형 연소기에서의 열-덕트 연성 소음의 능동 제어 연구)

  • 조상연;이용석;엄승신;이수갑
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.678-683
    • /
    • 1998
  • Combustion instability by thermoacoustic feedback incite strong low frequency noise and vibration which damage the system and provoke the environmental problems. Therefore, it is necessary to control the thermoacoustic oscillation. In the way of controlling the instability, active control method using adaptive algorithm is applied. In this study, active noise control method using anti-sound technique is selected, whose principle is cancelling the noise with the addition of opposite phase sound. At first, simulation is performed to confirm the stability of controller, and after that control of combustion instability is carried out to get cancellation of 20-30dB SPL.

  • PDF

Influence of Lubricating Oil Environments on Behavior of Cavitation Erosion for Alloy Metals of Bearing (베어링 합금재에 대한 캐비테이션 침식 거동에 미치는 윤활제 환경의 영향)

  • 임우조;이진열
    • Tribology and Lubricants
    • /
    • v.9 no.1
    • /
    • pp.55-61
    • /
    • 1993
  • Recently, due to the erosion damage that were generated increasingly at alloy metals of slide bearing by cavity of lubricating oil with tendency of high speed and high output of reciprocating engine, there is a need to study the process on the formation of cavitation erosion, and the characteristic of cavitation erosion at lubricating oil environments under various condition for marine ship. Therefore, the apparatus of cavitation erosion experiment used 20 KHz, $24 \mu m$ piezoelectric vibrator. The main results obtained through this test method are as follows: 1. The max. erosion rate at lubricating oil environments was related to the change of space, oil film thickness, and shown to tendency of gear oil>system oil>turbine oil>mixed oil environments with different viscosity. 2. The pitted hole by cavitation erosion at high viscosity oil environments became small and deep, and in addition to, they appeared to be wide and shallow at low viscosity.

An environment friendly tunnel construction method for railway tunnels (환경친화적인 철도 터널의 새로운 굴착공법)

  • 이종득;심재범;마거울프디트리히;한광모
    • Proceedings of the KSR Conference
    • /
    • 2001.10a
    • /
    • pp.410-415
    • /
    • 2001
  • Conventional Korean tunnel portals require a lot of overburden as, fer static reasons, about 1.5 to 2.0 times the tunnel diameter is needed for the height in order to achieve a sufficient arching effect. Thus, considerable movement of earth and support constructions are required which lead to undesirably large changes of and damage to the environment. With a massively designed pipe roof, tunnels with little overburden can be built. For the effective construction of a pipe roof as an advancing safeguarding method, the following properties are indispensable: stability, insensitivity to settling and drilling accuracy. With the AT casing system a new pipe roof method has been developed which on the one hand entirely combines the properties mentioned last, and which on the other hand permits safe, economical and environmentally friendly construction of tunnels at low overburden heights of 3 to 6 m.

  • PDF

Transient Impedance Characteristics of Mesh Grounding System under Impulse Current (임펄스 전류에 대한 메쉬접지계의 과도임피던스 특성)

  • Lee, Bok-Hee;Park, Jhong-Soon
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.361-363
    • /
    • 1997
  • Electronic devices are very weak against lightning surges injected from grounding systems and can be damaged. The malfunction and damage of electronic circuits bring about several disadvantages such as low operation performances, a lot of economical losses, and etc. In order to obtain the effective protection measure of electronic devices from overvoltages and lightning surges, the analysis of the transient grounding impedances is very important. The aim of this work is to evaluate the behaviors of transient grounding impedances under impulse currents and to investigate the effect of grounding lead wire. Z-t, Z-i and V-i curves of transient grounding impedance under impulse current waveforms have been measured and analyzed.

  • PDF

Vehicle Voltage Stabilizing Module Using Supercapacitors (슈퍼캐패시터를 이용한 자동차 전압 안정화 모듈)

  • Park, Sukhee;Jeong, Kyuwon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.1
    • /
    • pp.124-129
    • /
    • 2015
  • The performance of a passenger vehicle has been greatly improved recently owing to the intensive use of electronic controllers. Many components of a vehicle, including the engine, are controlled by electronic systems installed in the vehicle. Therefore, the electrical power required for such electronics has increased significantly. However, the electrical power generated by the vehicle's alternator, operated by the engine, is limited, and when the vehicle is started, a large instantaneous current is required. The voltage of the vehicle electrical system fluctuates to a very low level, then, it is gradually recovered. This case is very severe and can even cause damage to electronic systems. In this study, a voltage-stabilizing module comprising electric double layer supercapacitors, which could alleviate the voltage variation, was developed and tested.

Development of Algorithm for the Decision of Ship's Strong Wind Warning Levels

  • Shouhu, Hu;Moon, Serng-Bae
    • Journal of Navigation and Port Research
    • /
    • v.42 no.5
    • /
    • pp.317-322
    • /
    • 2018
  • Marine weather information provided for vessels is mainly offered by radio devices such as NAVTEX, Weather Fax., and others. However, the information is too general for large areas, and lacks more detail. So, many seafarers are disinclined to use the information to initiate proper readiness of vessels' safety, avoiding marine accidents such as grounding, hull and cargo damage, but cannot develop an optimal and economical navigation plan, considering the inadequate level of low precision weather information. The purpose of this paper is to develop a strong wind warning system, based on the digital anemometer installed on the bridge. This study analyzed the data on 10-minutes average wind speed, when the vessel's grounding accidents happened in Korean ports. Results reveal that the vessel's strong wind warning algorithm, can estimate the growing of wind speed two-three hours in advance.

Development of the Activity Type Smart Concrete using the Glass Pipe

  • Kim, Ie-Sung;Kim, Wha-Jung
    • Corrosion Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.29-32
    • /
    • 2005
  • A various structural materials are used in construction projects such as a stone, concrete, steel materials. Between of them, concrete are used widely. The compressive strength of concrete is high, and its maintenance and management is comparatively easy. The R.C Building will be superannuated as time passes. This program is generated by propagation of cracks. In order to manage such cracks, time and efforts, expense, etc. are required. In this study, glass sensors were embedding in a model beam and column and leakage of fluorescence and adhesive material was investigated. Further, currents in glass pipe were observed to find the leakage of liquid in glass pipes. Progressive cracks generated by cause the fracture of glass pipes. Therefore, the liquid become to flow and electric current stops, and the cracked part of the member can be found easily. Moreover, the adhesive delays progressive cracking system that responds in air, and the life of a structure can be made to extend. The purpose of this research is to develop of low price sensors that can perform of self-diagnosis in addition to ability of concrete repair concrete to damage.

Prediction of Possibility of Indoor Pipe Freezing in Heat Only Boiler Room through Thermal Analysis (열분석을 통한 열전용 보일러동 실내배관의 동파 가능성 예측)

  • Lim, Byoung-Ik;Chung, Kwang-Seop;Kim, Young-Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.3
    • /
    • pp.19-28
    • /
    • 2012
  • In a heat only boiler system of a steam power plant, outdoor air required for combustion is made to pass through indoor space for increasing the boiler efficiency. Due to heat generated by various equipments, temperature of the air that enters the boiler will increase resulting in combustion efficiency. If the outdoor air temperature is low, however, this will cause freezing and bursting of pipes which are filled with water. It is especially fatal to small diameter pipes and pipes connected to measuring instruments. The purpose of this study is find operation and outdoor conditions where this phenomena can happen and also establish preventive measures to avoid this problem.

A Study on the Influence of Stacking Sequences using CFRP Laminate Plates by Falling Weight Impact (탄소섬유복합평판에 낙추충격을 가할 때 적층구성에 미치는 영향에 관한 연구)

  • 임광희;박노식;양인영
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.11a
    • /
    • pp.106-109
    • /
    • 2000
  • Impact tester was build up to evaluate the characterization of CFRP laminate plates under the low velocity impact. The tests were conducted on several laminates of different ply orientation A system was budded for the impact strength of CFRP laminates in consideration of stress wave propagation theory using drop-weight impact tester as one of impact test. Results indicate that absorbed energy of quasi-isotropic specimen having four interfaces is higher than that of orthotropic laminates with two interfaces. Also the damage area was measured with ultrasonic C-scanner on some samples. In the specimens the relationship was linear between damaged area and absorbed energy to some degree. Absorbed energy in the specimen that ply number, interface number and fiber stacking sequences is same but having hybrid is higher than that of orthotropic laminates without hybrid.

  • PDF