• Title/Summary/Keyword: low background

Search Result 3,408, Processing Time 0.031 seconds

Neonatal Sepsis and Antimicrobial Susceptibilities in the Neonatal Intensive Care Unit and Nursery (신생아 패혈증의 원인 및 항생제 감수성)

  • Moon, Jin Hwa;Oh, Sung Hee;Kim, Hak Won;Moon, Su Jee;Choi, Tae Yeol
    • Pediatric Infection and Vaccine
    • /
    • v.9 no.2
    • /
    • pp.163-174
    • /
    • 2002
  • Background : To delineate the changes in the causative agents of neonatal sepsis and their antimicrobial susceptibilities in the neonatal intensive care unit and nursery of Hanyang University Hospital during the past 10 years. Methods : Hospital records of 15,144 patients hospitalized at the NICU and nursery of Hanyang University Hospital from 1989 to 1998 were reviewed and neonates diagnosed of neonatal sepsis were sorted and included in the study. The study period was divided into Period A(the first 5 years) and Period B(the second 5 years) to analyse causative agents and their antimicrobial susceptibilities. Results : Neonatal sepsis was diagnosed in 170 patients(1.1%{Period A 1.2%, Period B 1.0%}) among the total of 15,144 inpatients. Two hundred isolates(Period A 109 isolates, Period B 91 isolates) were identified in 186 blood cultures(Period A 99 cultures, Period B 87 cultures) from 170 patients(Period A 91 patients, Period B 79 patients). The average age at the onset of the disease, when the initial blood culture was drawn, was 12.3 days old(Period A 8.8 days, Period B 16.3 days), and the proportion of the early onset disease was 34.7% in Period A and 23.0% in Period B, indicating that neonatal sepsis developed earlier during Period A. Among the isolated organisms including Gram positive bacteria[132(66.0%)], Gram negative bacteria [60(30.0%)], and fungi[8(4.0%)], coagulase negative Staphylococcus(CNS) was the most common organism(69/34.5%), followed by Staphylococcus aureus(36/18.0%), Klebsiella pneumoniae(17/8.5%), Enterococcus(12/6.0%), Enterobacter cloacae(8/4.0%), Escherichia coli(6/3.0%), and Pseudomonas aeruginosae(5/2.5%). The isolated fungi were Candida parapsilosis, Candida albicans, and Trichosporon pullulans. CNS, S. aureus and Acinetobacter baumannii were isolated more frequently in Period A compared to Period B. Antimicrobial susceptibilities of CNS and S. aureus to methicillin and the first generation cephalo sporins were decreased in Period B compare to Period A, those to aminoglycosides were increased in Period B, and vancomycin resistant strains were not identified. K. pneumoniae, Enterococcus, E. coli, and P. aeruginosa were isolated less frequently in Period B, compared to Period A. For K. pneumoniae, antimicrobial susceptibilities to the first generation cephalosporins were low in both Periods A and B, those to tobramycin and gentamicin were increased in Period B, and those to amikacin, ceftriaxone, and trimethoprim-sulfamethoxazole were high in both Periods A and B. Antimicrobial susceptibilities of Enterococcous to ampicillin, penicillin, and the first generation cephalosporins were decreased in Period B, but vancomycin resistant strains were not identified. Conclusion : The occurrence rate of neonatal sepsis during the past 10 years in the NICU and nursery of the Hanyang University hospital was 1.1%, and the most common causitive agents were CNS and S. aureus, to which the antimicrobial susceptibilities to the first line drugs decreased in the later half of the study period with no vancomycin resistant isolates identified. Group B Streptococcus known to be the most common agent causing neonatal sepsis was not identified, and K. pneumoniae was isolated more commonly during the later half of the study period without decreased antimicrobial susceptibilities.

  • PDF

Comparison of the One-year Follow-up Results after Coronary Bypass Surgery versus Percutaneous Coronary Intervention with Drug-eluting Stents in Patients with Left Main Coronary Artery Disease (좌주간지 병변에 대한 약물방출스텐트시술과 관상동맥우회수술의 1년 추적결과 비교)

  • Choi, Jin-Ho;Lim, Cheong;Park, Kay-Hyun;Chung, Eui-Suk;Chung, Woo-Young;Chae, In-Ho;Choi, Dong-Ju
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.210-215
    • /
    • 2008
  • Background: Drug-eluting stents are contributing to the exponential growth of percutaneous coronary intervention, and even in the patients with left main coronary artery disease, owing to the decreased restenosis rate. Our study aimed at comparing the one-year results after coronary artery bypass grafting versus percutaneous coronary intervention with drug-eluting stents in patients with left main coronary artery disease. Material and Method: Those patients who underwent coronary bypass surgery or stenting at our hospital under the diagnosis of left main coronary artery disease were divided in two groups. The variables for comparison were the preoperative disease severity, the length of the hospital stay, the early mortality and the cumulative incidence of mortality, myocardial infarction and repeated revascularization. Result: There were 101 cases in the surgery group and 78 cases in the stent group. Age, gender, the risk factors, the left ventricular ejection fraction and the proportion of acute coronary syndrome showed no significant differences between the two groups. The surgery group showed a more severe condition according to the Euroscore, a greater incidence of urgency, a longer hospital stay and a greater incidence of multi-vessel disease. The early mortality and one-year cumulative mortality were not different between the groups. The Euroscore-matched comparison for the surgery group (41 patients) and the stent group (78 patients) showed no significant differences in the Euroscore, age, gender, risk factors and the proportion of acute coronary syndrome. The surgery group in the Euroscore-matched comparison showed more multi-vessel disease and a longer hospital stay. The surgery group showed lower early mortality and lower one-year cumulative mortality, but this was statistically insignificant (0% vs 2.6%, respectively, p=0.55; 0% vs 6.6%, respectively, p=0.30). The rates of repeated revascularization and major adverse events (death or myocardial infarct) were lower in the CABG group, but this was not statistically significant (13.3% vs 6.3%, respectively, p=0.48; 10.0% vs 0%, respectively, p=0.09). Conclusion: Percutaneous coronary intervention using drug-eluting stents in low-risk patients with left main coronary artery disease resulted in a shortened length of the hospital stay, as compared with that of the CABG group of patients. However, the patients who underwent percutaneous coronary intervention using drug-eluting stents showed a tendency for an increased rate of repeated revascularization and higher one-year cumulative mortality. Further studies with large populations and longer follow-up will be necessary to reaffirm our findings.

Lymphocyte Proportion and Cytokines from the Bone Marrow of Patients with Far-Advanced Pulmonary Tuberculosis with Peripheral Lymphocytopenia (말초혈액의 림프구감소증을 동반한 중증폐결핵 환자들에서 골수 내의 림프구 분획과 사이토카인 소견)

  • An, Chang Hyeok;Kyung, Sun Yong;Lim, Young Hee;Park, Gye Young;Park, Jung Woong;Jeong, Sung Hwan;Ahn, Jeong Yeal
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.5
    • /
    • pp.449-458
    • /
    • 2003
  • Background : The poor prognostic factors of far-advanced pulmonary tuberculosis(FAPTB) are lymphocytopenia in the peripheral blood(PB)(< $1,000/mm^3$) and $T_4$-cell count ${\leq}500/mm^3$. However, the cause of PB lymphocytopenia in FAPTB is unclear. The aim of this study was to analyze the lymphocyte proportion and cytokines of the bone marrow(BM) in FAPTB patients with peripheral lymphocytopenia in order to clarify whether the limiting step of the lymphocytopenia occurs in production, differentiation, or circulation. Methods : This study included patients with FAPTB between August 1999 and August 2002 who visited Gachon Medical School Gil Medical Center. The exclusion criteria were old age(${\geq}65years$), cachexia or a low body weight, shock, hematologic diseases, or BM involvement of tuberculosis. The distributions of cells in PB and BM were analyzed and compared to the control group. The interleukin(IL)-2, IL-7, IL-10, TNF-${\alpha}$, Interferon-${\gamma}$, and TGF-${\beta}$ levels in the BM were measured by ELISA. Result : Thirteen patients(male : female=9:4) were included and the mean age was $42{\pm}12$years. The proportion and count of the lymphocytes in the PB were significantly lower in the FAPTB group ($7.4{\pm}3.0%$, $694{\pm}255/mm^3$ vs. $17.5{\pm}5.8%$, $1,377{\pm}436/mm^3$, each p=0.0001 and 0.002). The proportion of immature lymphocyte in the BM showed a decreasing trend in the FAPTB group($9{\pm}4%$ vs. $12{\pm}3%$, p=0.138). The IL-2($26.0{\pm}29.1$ vs. $112.2{\pm}42.4pg/mL$, p=0.001) and IL-10($3.4{\pm}4.7$ vs. $12.0{\pm}8.0pg/mL$, p=0.031) levels in the BM were significantly lower in the FAPTB group than those in control. The levels of the other cytokines in FAPTB group and control were similar. Conclusion : These results suggest that the cause of lymphocytopenia in PB is associated with a abnormality IL-2 and IL-10 production in the BM. More study will be needed to define the mechanism of a decreased reservoir in BM.

Lower Lung Field Tuberculosis (폐 하야 결핵)

  • Moon, Doo-Seop;Lim, Byung-Sung;Kim, Yeon-Soo;Kim, Seong-Min;Lee, Jae-Young;Lee, Dong-Suck;Sohn, Jang-Won;Lee, Kyung-Sang;Yang, Suck-Chul;Yoon, Ho-Joo;Shin, Dong-Ho;Park, Sung-Soo;Lee, Jung-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.232-240
    • /
    • 1997
  • Background : Postprimary pulmonary tuberculosis is located mainly in upper lobes. The tuberculous lesion involving the lower lobes usually arises from the upper lobe cavity through endobronchial spread. When tuberculosis is confined to the lower lung field, it often masquerades as pneumonia, lung cancer, bronchiectasis, or lung abscess. Thus the correct diagnosis may be sometimes delayed for a long time. Methods : We carried out, retrospectively, a clinical study on 50 patients confirmed with lower lung field tuberculosis who visited the Department of Pulmonary Medicine at Hanyang University Hospital from January 1992 to December 1994. The following results were obtained. Results : Lower lung field tuberculosis without concomitant upper lobe disease occurred in fifty patients representing 6.9% of the total admission with active pulmonary tuberculosis over a period of 3 years. It occurred most frequently in the third decade but age distribution was relatively even. The mean age was 43 years old. Female was more frequently affected than male (male to female ratio 1 : 1.9). The most common symptom was cough(68%), followed by sputum(52%), fever(38%), and chest discomfort(30%). On chest X-ray of the 50patients, consolidation was the most common finding in 52%, followed by solitary nodule(22%) collapse(16%), cavitary lesion(10%), in decreasing order. The disease confined to the right side in 25 cases, left side 20 cases, and both sides 5 cases. Endobronchial tuberculosis (1) Endobronchial involvement was proved by bronchoscopic examination in 20 of 50patients. (2) Mean age was 44years old and female was more affected than man (male to female ratio 1 : 3). Sputum AFB stain and Mycobacterium tuberculosis culture were positive only in 50% of cases unlikely upper lobe tuberculosis, additional diagnostic methods were needed. In our study, bronchoscopic examination and percutaneous fine needle aspiration biopsy increased diagnostic yield by 18% and 32%, respectively. The most common associated condition was diabetes mellitus(18%) and others were anemia, anorexia nervosa, stomach cancer, and systemic steroid usage. Conclusion : When we find a lower lung field lesion, we should suspect tuberculosis if the patient has diabetes mellitus, anemia, systemic steroid usage, malignancy or other immune suppressed states. Because diagnostic yield of sputum AFB smear & Mycobacterium tuberculosis culture was low, additional diagnostic methods such as bronchoscopy and fine needle aspiration biopsy were needed.

  • PDF

Application of Support Vector Regression for Improving the Performance of the Emotion Prediction Model (감정예측모형의 성과개선을 위한 Support Vector Regression 응용)

  • Kim, Seongjin;Ryoo, Eunchung;Jung, Min Kyu;Kim, Jae Kyeong;Ahn, Hyunchul
    • Journal of Intelligence and Information Systems
    • /
    • v.18 no.3
    • /
    • pp.185-202
    • /
    • 2012
  • .Since the value of information has been realized in the information society, the usage and collection of information has become important. A facial expression that contains thousands of information as an artistic painting can be described in thousands of words. Followed by the idea, there has recently been a number of attempts to provide customers and companies with an intelligent service, which enables the perception of human emotions through one's facial expressions. For example, MIT Media Lab, the leading organization in this research area, has developed the human emotion prediction model, and has applied their studies to the commercial business. In the academic area, a number of the conventional methods such as Multiple Regression Analysis (MRA) or Artificial Neural Networks (ANN) have been applied to predict human emotion in prior studies. However, MRA is generally criticized because of its low prediction accuracy. This is inevitable since MRA can only explain the linear relationship between the dependent variables and the independent variable. To mitigate the limitations of MRA, some studies like Jung and Kim (2012) have used ANN as the alternative, and they reported that ANN generated more accurate prediction than the statistical methods like MRA. However, it has also been criticized due to over fitting and the difficulty of the network design (e.g. setting the number of the layers and the number of the nodes in the hidden layers). Under this background, we propose a novel model using Support Vector Regression (SVR) in order to increase the prediction accuracy. SVR is an extensive version of Support Vector Machine (SVM) designated to solve the regression problems. The model produced by SVR only depends on a subset of the training data, because the cost function for building the model ignores any training data that is close (within a threshold ${\varepsilon}$) to the model prediction. Using SVR, we tried to build a model that can measure the level of arousal and valence from the facial features. To validate the usefulness of the proposed model, we collected the data of facial reactions when providing appropriate visual stimulating contents, and extracted the features from the data. Next, the steps of the preprocessing were taken to choose statistically significant variables. In total, 297 cases were used for the experiment. As the comparative models, we also applied MRA and ANN to the same data set. For SVR, we adopted '${\varepsilon}$-insensitive loss function', and 'grid search' technique to find the optimal values of the parameters like C, d, ${\sigma}^2$, and ${\varepsilon}$. In the case of ANN, we adopted a standard three-layer backpropagation network, which has a single hidden layer. The learning rate and momentum rate of ANN were set to 10%, and we used sigmoid function as the transfer function of hidden and output nodes. We performed the experiments repeatedly by varying the number of nodes in the hidden layer to n/2, n, 3n/2, and 2n, where n is the number of the input variables. The stopping condition for ANN was set to 50,000 learning events. And, we used MAE (Mean Absolute Error) as the measure for performance comparison. From the experiment, we found that SVR achieved the highest prediction accuracy for the hold-out data set compared to MRA and ANN. Regardless of the target variables (the level of arousal, or the level of positive / negative valence), SVR showed the best performance for the hold-out data set. ANN also outperformed MRA, however, it showed the considerably lower prediction accuracy than SVR for both target variables. The findings of our research are expected to be useful to the researchers or practitioners who are willing to build the models for recognizing human emotions.

A Study for Improvement of Erythropoietin Responsiveness in Hemodialysis Patients (혈액 투석 환자에서 조혈 호르몬 치료 효과 향상에 대한 연구)

  • Park, Jong-Won;Do, Jun-Yeung;Yoon, Kyung-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.2
    • /
    • pp.226-238
    • /
    • 2001
  • Background: Anemia in chronic renal failure plays an important role in increasing morbidity of dialysis patients. The causes of the anemia are multifactorial. With using of erythropoietin(EPO) most of uremia-induced anemia can be overcome. However, about 10% of renal failure patients shows EPO-resistant anemia. Hyporesponsiveness to EPO has been related to many factors: iron deficiency, aluminum intoxication, inflammations, malignancies and secondary hyperparathyroidism. So I evaluated the improvement of EPO responsiveness after correction of above several factors. Materials and Methods: Seventy-two patients on hemodialysis over 6 months were treated with intravenous ascorbic acid(IVAA, 300 mg t.i.w. for 12 weeks), After administration of IVAA for 12 weeks, patients were classified into several groups according to iron status, serum aluminum levels and i-PTH levels. Indivisualized treatments were performed: increased iron supplement for absolute iron deficiency, active vitamin D3 for secondary hyperparathyroidism and desferrioxamine(DFO, 5 mg/kg t.i.w.) for aluminum intoxication or hyperferritinemia. Results: 1) Result of IVAA therapy for 12 weeks on all patients(n=72). Hemoglobin levels at 2, 4, 6 week were significantly elevated compared to baseline, but those of hemoglobin at 8, 10, 12 week were not significantly different. 2) Result of IVAA therapy for 20 weeks on patients with 100 ${\mu}g/l$ ${\leq}$ ferritin < 500 ${\mu}g/l$ and transferrin saturation(Tsat) below 30%(n=30). After treatment of IV AA for 12 weeks, patients were evaluated the response of therapy according to iron status. Patients with 100 ${\mu}g/l$ ${\leq}$ ferritin < 500 ${\mu}g/l$ and Tsat below 30% showed the most effective response. These patients were treated further for 8 weeks. Hemoglobin levels at 2, 4 week were significantly increased compared to baseline with significantly reduced doses of EPO at 2, 4, 6, 10, 12, 16, 20 week. Concomitantly significantly improvement of Tsat at 2, 6, 16, 20 week compared to baseline were identified. 3) Result of IVAA therapy for 12 weeks followed by DFO therapy for 8 weeks on patients with serum aluminum above 4 ${\mu}g/l$(n=12) Hemoglobin levels were not significantly increased during IVAA therapy for 12 weeks but dosages of EPO were significantly decreased at 2, 4, 6, 8 week during DFO therapy compared to pre-treatment status. Conclusion: IVAA can be helpful for the treatment of the anemia caused by functional iron deficiency and can reduce the dosage of EPO for anemia correction. And administration of low dose DFO, in cases of increased serum aluminum level, can reduce the requirement of EPO.

  • PDF

Clinical Indices Predicting Resorption of Pleural Effusion in Tuberculous Pleurisy (결핵성 늑막염에서 삼출액의 흡수에 영향을 미치는 임상적 지표)

  • Lee, Joe-Ho;Chung, Hee-Soon;Lee, Jeong-Sang;Cho, Sang-Rok;Yoon, Hae-Kyung;Song, Chee-Sung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.5
    • /
    • pp.660-668
    • /
    • 1995
  • Background: It is said that tuberculous pleuritis responds well to anti-tuberculous drug in general, so no further aggressive therapeutic management is unnecesarry except in case of diagnostic thoracentesis. But in clinical practice, we often see some patients who need later decortication due to dyspnea caused by pleural loculation or thickening despite several months of anti-tuberculous drug therapy. Therefore, we want to know the clinical difference between a group who received decortication due to complication of tuberculous pleuritis despite of anti-tuberculous drug and a group who improved after 9 months of anti-tuberculous drug only. Methods: We reviewed 20 tuberculous pleuritis patients(group 1) who underwent decortication due to dyspnea caused by pleural loculation or severe pleural thickening despite of anti-tuberculous drug therapy for 9 or more months, and 20 other tuberculous pleuritis patients(group 2) who improved by anti-tuberculous drug only and had similar degrees of initial pleural effusion and similar age, sex distribution. Then we compared between the two groups the duration of symptoms before anti-tuberculous drug treatment and pleural fluid biochemistry like glucose, LDH, protein and pleural fluid cell count and WBC differential count, and we also wanted to know whether there was any difference in preoperative PFT value and postoperative PFT value in the patients who underwent decortication, and obtained following results. Results: 1) Group 1 patients had lower glucose level{$63.3{\pm}30.8$(mg/dl)} than that of the group 2{$98.5{\pm}34.2$(mg/dl), p<0.05}, and higher LDH level{$776.3{\pm}266.0$(IU/L)} than the group 2 patients{$376.3{\pm}123.1$(IU/L), p<0.05}, and also longer duration of symptom before treatment{$2.0{\pm}1.7$(month)} than the group 2{$1.1{\pm}1.2$(month), p<0.05}, respectively. 2) In group 1, FVC changed from preoperative $2.55{\pm}0.80$(L) to postoperative $2.99{\pm}0.78$(L)(p<0.05), and FEV1 changed from preoperative $2.19{\pm}0.70$(L/sec) to postoperative $2.50{\pm}0.69$(L/sec)(p<0.05). 3) There was no difference in pleural fluid protein level($5.05{\pm}1.01$(gm/dL) and $5.15{\pm}0.77$(gm/dl), p>0.05) and WBC differential count between group 1 and group 2. Conclusion: It is probable that in tuberculous pleuritis there is a risk of complication in the case of showing relatively low pleural fluid glucose or high LDH level, or in the case of having long duraton of symptom before treatment. We thought prospective study should be performed to confirm this.

  • PDF

The Comparison Study of Early and Midterm Clinical Outcome of Off-Pump versus On-Pump Coronary Artery Bypass Grafting in Patients with Severe Left Ventricular Dysfunction (LVEF${\le}35{\%}$) (심한 좌심실 부전을 갖는 환자에서 시행한 Off-Pump CABG와 On-Pump CABG의 중단기 성적비교)

  • Youn Young Nam;Lee Kyo Joon;Bae Mi Kyung;Shim Yeon Hee;Yoo Kyung-Jong
    • Journal of Chest Surgery
    • /
    • v.39 no.3 s.260
    • /
    • pp.184-193
    • /
    • 2006
  • Background: Off-pump coronary artery bypass grafting (OPCAB) has been proven to result in less morbidity. The patients who have left ventricular dysfunction may have benefits by avoiding the adverse effects of the cardiopulmonary bypass. The present study compared early and midterm outcomes of off-pump versus on-pump coronary artery bypass grafting (On pump CABG) in patients with severe left ventricular dysfunction. Material and Method: Ninety hundred forth six patients underwent isolated coronary artery bypass grafting by one surgeon between January 2001 and Febrary 2005.. Data were collected in 100 patients who had left ventricular ejection fraction (L VEF) less than $35\%$ (68 OPCAB; 32 On pump CABG). Mean age of patients were 62.9$\pm$9.0 years in OPCAS group and 63.8$\pm$8.0 years in On pump CABG group. We compared the preoperative risk factors and evaluated early and midterm outcomes. Result: In OPCAB and On pump CABG group, mean number of used grafts per patient were 2.75$\pm$0.72, 2.78$\pm$0.55 and mean number of distal anastomoses were 3.00$\pm$0.79, 3.16$\pm$0.72 respectively. There was one perioperative death in OPCAB group ($1.5\%$). The operation time, ventilation time, ICU stay time, CK-MB on the first postoperative day, and occurrence rate of complications were significantly low in OPCAB group. Mean follow-up time was 26.6$\pm$12.8 months (4${\~}$54 months). Mean LVEF of OPCAB and On pump CABG group improved significantly from $27.1\pm4.5\%$ to $40.7\pm13.0\%$ and $26.9\pm5.4\%$ to $33.3\pm13.7\%$. The 4-year actuarial survival rate of OPCAB and On pump CABG group were $92.2\%,\;88.3\%$ and the 4-year freedom rates from cardiac death were $97.7\%,\;96.4\%$ respectively. There were no significant differences between two groups in 4 year freedom rate from cardiac event and angina. Conclusion: OPCAS improves myocardial function and favors early and mid-term outcomes in patients with severe left ventricular dysfunction compared to On pump CABG group. Therefore, OPCAB is a preferable operative strategy even in patients with severe left ventricular dysfunction.

The Influence of Art-provoked Affect on Product and Product Attributes Evaluation (명화(名畵)에서 유발된 감정이 차용된 제품과 제품속성 평가에 미치는 영향)

  • Kim, Hanku;Jung, Bohee;Chu, Wujin
    • Asia Marketing Journal
    • /
    • v.13 no.2
    • /
    • pp.99-130
    • /
    • 2011
  • In recent years, a new way of differentiating product design has emerged -better known as 'masterpiece marketing,' this is a strategy where famous art pieces are borrowed on to product designs. Because the recent trends of well-being and LOHAS have encouraged the consumers' desires to enjoy culture and live a more opulent lifestyle, famous and notable paintings have grown to be more of "approachable masterpieces" to the public. As a strategy intended to develop a new consumerism, while still prioritizing customers' values and their satisfaction, companies have been drawn to this new type of marketing. The current consumption society has converted renowned art pieces from simply works of 'high culture' to a further way of marketing, aimed to differentiate products and dominate the market. Though many products have had masterpieces applied to their designs and have been noticed for their marketability, there has been less systematic research done on the scientific background behind this marketing approach. This research focused on the art pieces' fundamental nature of inducing emotions in the viewer, and hypothesized about how the evaluation of a product may be influenced by the affect provoked by the art piece used. To be more specific, if art pieces with different levels of pleasure and arousal -the two axis of emotion suggested by existing research on emotion -were used on each product, the goal was to see how the different levels influenced the consumer's assessment of the products, focusing on product's type as well as the evaluation of their attributes. First, a pretest was done to verify the relationship between the emotion provoked by the art piece and the consumer's preference. There were two types of surveys, each with five drawings from the ten that were assumed to differ in levels of the two axis of emotion. The survey was composed of questions asking for positive emotion, negative emotion, level of arousal, and preference. The correlation between the measurements of positive and negative emotions was -0.792, so an integrated entry was used in the analysis by subtracting the measurement of negative emotions from that of positive emotions. The first hypothesis that paintings that provoke positive emotions will be more preferred than paintings that bring out negative emotions was supported; and through this research, paintings that were to be used for the products were selected. The second pretest was conducted to settle on an item that would be used in the research. Items meant to measure utilitarian and hedonic attributes of milk and chocolate, the two products to be used in the research, were extracted. Because milk is a utilitarian product with strong practical attributes while chocolate is a hedonic product with strong hedonic attributes, these two were selected to be used in this research. The first study was executed to see if there is a difference in attitude about products that have different painting on their designs, which either induces positive or negative emotions. It was also to verify whether this difference in attitude was mediated by the viewer's preference for the art piece. This study showed that when positive emotion inducing painting was used, the product was better evaluated compared to the product with a painting that provokes a negative emotion, thus supporting the second hypothesis. It was also supported that the effect of affect on product evaluation was mediated by preference for the art piece. The second study was done to see the influence of the level of arousal on the evaluation of the product's attributes. Art pieces that differ in the level of arousal were selected through the pretest, and later it verified the hypothesis that the level of arousal has an effect on the assessment of the attributes of the product. In the case of milk, a utilitarian product, the fourth hypothesis that a high-arousal painting will better evaluated for its hedonic attributes was supported, as well as the fifth, which hypothesized that a low-arousal painting will receive a higher assessment for its utilitarian attributes. However, for chocolate, a hedonic product, both fourth and fifth hypotheses were not supported. This study is significant for the following basis: first, it verified the importance of the emotion induced by the painting on the evaluation of the product's attributes, by applying a systematic and scientific method. Second, it expanded from the existing research on positive/negative emotions to confirm the additional influence of the state of arousal on product evaluation.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF