• 제목/요약/키워드: loss frequency

검색결과 3,544건 처리시간 0.036초

Relationship Between AC and DC Magnetic Properties of an Iron-Based Amorphous Alloy for High Frequency Applications

  • Choi, Y.S.;Noh, T.H.;Lim, S.H.
    • Journal of Magnetics
    • /
    • 제1권1호
    • /
    • pp.24-30
    • /
    • 1996
  • The relationship between effective permeability and the remanence ratio of an Fe-based amorphous alloy (Metglas 2605S3A) is investigated over a wide frequency range, in an effort to understand magnetization behavior of the alloy. In the frequency range from 1 to 200 kHz, the permeability is maximum at the remanence ratio of 0.4-0.5 and, at frequencies over 500 kHz, the correlation with negative coefficients emerges indicating that the permeability decreases with the remanent ratio, except for the ribbon coated with an insulating layer of MgO which exhibits both high values of the effective permeability and remanence ratio. It is considered from the correlation results that the boundary at which the dominant magnetization mechanism changes from domain wall motion to spin rotation is near 500 kHz. The core loss is also investigated as a function of annealing time when the samples are annealed at a fixed temperature of $435^{\circ}C$. The core loss in most cases decreases with the annealing time, the degree of the loss may consist of the hysteresis loss and anomalous eddy current loss. The two loss components are considered to be of similar magnitudes at low frequencies while, at high frequencies, the dominant contribution to the total loss is the anomalous loss.

  • PDF

In situ cavity loss measurements of a mode-locked erbium-doped fiber ring laser by thed relaxation oscillation frequency method

  • Jhon, Young-Min;Kim, Bong-Kyu;Kim, Dong-Hwan;Kim, Myong-Wook;Kim, Sang-Kuk;Choi, Sang-Sam
    • Journal of the Optical Society of Korea
    • /
    • 제4권1호
    • /
    • pp.11-13
    • /
    • 2000
  • We experimentally measured the cold cavity loss of a mode-locked erbium-doped fiber ring laser in situ by using the relaxation oscillation frequency method. The relaxation oscillation frequency is measured for various pumping powers and the data is fitted by the least squares method with a theoretical curve of parameters including the cavity loss. We obtained a cavity loss of 15.3$\pm$0.5 dB which was found to agree with the results of direct transmission loss measurements.

전기유변유체의 점탄성 특성에 관한연구 (Viscoelastic properties of electrorheological fluids)

  • 최윤대;김상국
    • 한국재료학회지
    • /
    • 제2권3호
    • /
    • pp.220-227
    • /
    • 1992
  • 전기유변유체(electrorheological fluid : ERF)는 크기가 $10^{-6}m$정도를 가진 분극성이 강한 입자 분말을 유전유체속에 혼합하여 만든 콜로이드용액으로서 외부전기 장에 의하여 액체상태로부터 겔(gel)상태로 상태변환을 한다. 상태변환과정은 가역과정이며 $10^{-3}$초 정도의 빠른 시간내에 이루어진다. 본 논문에서는 주기적응력이나 주기적 변형이 가해지는 강제진동실험을 통하여 ERF의 점탄성 특성을 조사하였다. 점탄성은 복소수로서 실수부인 동적전단탄성율(storage shear modulus, G')과 허수부인 동적손실율(loss modulus, G")의 합으로 표현된다. 동적전단탄성율은 강제진동의 진폭과 주파수의 함수로 외부전기장에 의하여 크게 변화되었으나 손실계수(loss factor, ${\eta}=G"/G'$)는 진동의 진폭, 진동수 및 외부전기 장에 거의 독립적이었다. 실험(1)은 강제진동의 진폭을 고정하고 진동수를 변화하는 방법(frequency sweep)과 실험(2)는 진동 진폭을 변화시키는 방법(amplitude sweep)으로 실행했다. 본 실험에서는 cornstarch입자를 corn oil에 혼합한 것과 zeolite입자를 silicone oil에 흔합한 콜로이드 용액이 ERF로서 사용되었으며 인가된 전기장은 약$(1~3){\times}10^6V/m$의 직류전기장이 가하여졌다.기장이 가하여졌다.

  • PDF

황해에서 저주파 음파의 해저손실 변동 (Bottom Loss Variation of Low-Frequency Sound Wave in the Yellow Sea)

  • 김봉채
    • Ocean and Polar Research
    • /
    • 제29권2호
    • /
    • pp.113-121
    • /
    • 2007
  • The sound wave in the sea propagates under the effect of water depth, sound speed structure, sea surface roughness, bottom roughness, and acoustic properties of bottom sediment. In shallow water, the bottom sediments are distributed very variously with place and the sound speed structure varying with time and space. In order to investigate the seasonal propagation characteristics of low-frequency sound wave in the Yellow Sea, propagation experiments were conducted along a track in the middle part of the Yellow Sea in spring, summer, and autumn. In this paper we consider seasonal variations of the sound speed profile and propagation loss based on the measurement results. Also we quantitatively investigate variation of bottom loss by dividing the propagation loss into three components: spreading loss, absorption loss, and bottom loss. As a result, the propagation losses measured in summer were larger than the losses in spring and autumn, and the propagation losses measured in autumn were smaller than the losses in spring. The spreading loss and the absorption loss did not show seasonal variations, but the bottom loss showed seasonal variations. So it was thought that the seasonal variation of the propagation loss was due to the seasonal change of the bottom loss and the seasonal variation of the bottom loss was due to the change of the sound speed profile by season.

Flat TR용 페라이트 코아의 고주파 동작 특성 (Study on operating characteristics of Ferrite cores for Flat TR in high frequency)

  • 한세원;조한구;류동욱;최광보
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1168-1171
    • /
    • 2003
  • In contrast to a conventional transformer, the flat transformer is made using a number of small ferrite cores. Two cores for transformer and one core for inductor, which composed one module. Many modules can be connected together to form a flat matrix transformer. This structural arrangement eliminates the single hot spot problem in conventional transformers and permits high current density pertains at high frequency. In this study, the ferrite magnetic cores of Mn-Zn system for the Flat transformer were manufactured and the electrical and magnetic characteristics of its tested. The power loss of sample FO2(Mn-Zn ferrite) sintered at $1350^{\circ}C$ was $350kW/m^3$ in test conditions of 250kHz, 200mT and $100^{\circ}C$, which showed the good power loss property in high frequency. The power loss of FO2 samples has been studied as a function of magnetic flux density and frequency. Steinmetz exponent was 2.82 at 250kHz and 2.73 at 500kHz. These results illustrated the switching of power loss mechanism in ferrite core from hysteresis losses to eddy current losses or others.

  • PDF

선박 격벽의 저주파수 대역 차음성능 향상에 관한 연구 (Improvement of Sound Transmission Loss of Ship's Bulkhead at Low Frequency Range)

  • 김성훈;주원호;배종국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.167-168
    • /
    • 2009
  • The noise sources in ship and offshore structure have an influence on adjacent receiving area through a partition between noise sources and receiving area. The partition in ship is usually made of stiffened plate. Sound transmission loss (STL) of the partition at high frequency could be improved by additional installation of insulation or wall panel. At low frequency, however, it is very difficult and needs an increase of plate thickness which causes a considerable weight increase of ship. In this paper, we have investigated the effect of the bulkhead boundary condition. From measurement result, we found that the bulkhead boundary condition can affect a lot in STL, especially at low frequency range. Finally, we get the 5dB increase in STL through the modification of boundary condition.

  • PDF

점탄성 물질의 온도와 주파수 의존성을 고려한 구속형 제진보의 최대 손실계수 설계 (Optimal Layout Design of Frequency- and Temperature-Dependent Viscoelastic Materials for Maximum Loss Factor of Constrained-Layer Damping Beam)

  • 이두호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1023-1026
    • /
    • 2007
  • Optimal damping layout of the constrained viscoelastic damping layer on beam is identified with temperatures by using a gradient-based numerical search algorithm. An optimal design problem is defined in order to determine the constrained damping layer configuration. A finite element formulation is introduced to model the constrained damping layer beam. The four-parameter fractional derivative model and the Arrhenius shift factor are used to describe dynamic characteristics of viscoelastic material with respect to frequency and temperature. Frequency-dependent complex-valued eigenvalue problems are solved by using a simple resubstitution algorithm in order to obtain the loss factor of each mode and responses of the structure. The results of the numerical example show that the proposed method can reduce frequency responses of beam at peaks only by reconfiguring the layout of constrained damping layer within a limited weight constraint.

  • PDF

$Ni_{0.5}Cu_{0.1}Zn_{0.4}Fe_2O_4$ Ferrite-Rubber Composite의 전파흡수특성에 미치는 열처리 온도의 영향 및 Carbon 첨가효과 (Effect of Carbon Addition and Influence of Heat-treatment Temperature on Electromagnetic Wave Absorbing Properties of $Ni_{0.5}Cu_{0.1}Zn_{0.4}Fe_2O_4$-Rubber Composite)

  • 윤국태;이찬규;박연준
    • 한국자기학회지
    • /
    • 제11권1호
    • /
    • pp.14-20
    • /
    • 2001
  • The structure, shape, size, and magnetic properties of Ni$_{0.5}$Cu$_{0.1}$Zn$_{0.4}$Fe$_2$O$_4$ have been investigated as a function of annealing temperatures. In order to control the microwave absorbing properties of ferrite-rubber composite and the complex losses (magnetic loss and conduction loss), the effect of carbon addition was also studied. It was found that the coercive force decreased with increasing heat-treatment temperatures. Relative complex permeability and reflection loss were measured by the network analyzer. As a result, the natural resonance occurred in the low frequency tinge, and the matching frequency of the ferrite-rubber composite prepared at 130$0^{\circ}C$ was found to be lower. As heat-treatment temperatures were increased, the magnetic loss ($\mu$$_{r}$", $\mu$$_{r}$′) and the dielectric loss ($\varepsilon$$_{r}$"/$\varepsilon$$_{r}$′) were increased. It was caused that the absorption characteristics of the absorber were improved. The conduction loss and magnetic loss were expected to be occurred together because two matching frequencies were shown with carbon addition. It was confirmed that the matching frequency of the microwave absorber could be controlled by controlling heat-treatment temperatures and carbon additions.ons.tions.

  • PDF

An Adaptive Narrowband Interference Excision Filter with Low Signal Loss for GPS Receivers

  • Shin, Mi-Young;Park, Chan-Sik;Lee, Ho-Keun;Lee, Dae-Yearl;Lee, Sang-Jeong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1234-1238
    • /
    • 2005
  • As the low power GPS signal is susceptible to interference, interference can seriously degrade the performance of GPS receiver. This paper designs a ANIEF(Adaptive Narrowband Interference Excision in Frequency domain) filter that removes narrow band interferences with low signal loss. This filter uses the pre-correlation technique and attempts to filter out the interference in the frequency domain. The interference excision performance of the designed filter is evaluated for various interferences using the ANIEF filter inserted GPS software receiver and the interference generator. Interferences considered in this paper are single-tone CWI(Continuous Wave Interference), multi-tones CWI, pulsed CWI, and swept CWI. The narrowband interference excision filter in frequency domain is very effective against various interferences and the strong interference with a simple structure. However, the signal power loss is unavoidable while transforming. In this paper, the hamming window and overlap technique are adopted to reduce the signal power loss. Finally, the interference excision performance and the reduced signal power loss of the ANIEF filter are shown.

  • PDF

진동기반 구조식별을 통한 프리스트레스트 콘크리트 거더의 긴장력 손실 검색 기법 (Prestress-Loss Monitoring Technique for Prestressd Concrete Girders using Vibration-based System Identification)

  • 호득유이;홍동수;김정태
    • 한국해양공학회지
    • /
    • 제24권1호
    • /
    • pp.123-132
    • /
    • 2010
  • This paper presents a prestress-loss monitoring technique for prestressed concrete (PSC) girder structures that uses a vibration-based system identification method. First, the theoretical backgrounds of the prestress-loss monitoring technique and the system identification technique are presented. Second, vibration tests are performed on a lab-scaled PSC girder for which the modal parameter was measured for several prestress-force cases. A numerical modal analysis is performed by using an initial finite element (FE) model from the geometric, material, and boundary conditions of the lab-scaled PSC girder. Third, a vibration-based system identification is performed to update the FE model by identifying structural parameters since the natural frequency of the FE model became identical to the experimental results. Finally, the feasibility of the prestress-loss monitoring technique is evaluated for the PSC girder model by using the experimentally measured natural frequency and numerically identified natural frequency for several prestress-force cases.