• Title/Summary/Keyword: loss angle

Search Result 844, Processing Time 0.041 seconds

A Study on the Measurement and Analysis Method for the Acoustic Transmission Loss of the Material for the Acoustic Window of Sonar Dome (소나 돔 음향창 시편 투과손실 측정/분석 방법 고찰)

  • Jung, Woo-Jin;Han, Seung-Jin;Kim, Won-Ho;Shin, Ku-Kyun;Jeon, Jae-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1183-1189
    • /
    • 2006
  • Knowledge of acoustic transmission loss of acoustic window material has a great Importance for the sonar performance in ship. The purpose of This study was to investigate the measurement and analysis method for me acoustic transmission loss of the acoustic window materials for sonar dome. The measurement and analysis were carried out in water with GRP material. Transmission losses were calculated based on integrated direct and transmitted signals. The experimental setup enabled to vary the angle of incidence. Thus the transmission loss data could be expressed as the function of frequency and angle of rotation. In this paper, diffraction effect of incident angle, size of specimen with test material, transmission analysis method and multiple waves as incident acoustic signal wet-e discussed

  • PDF

An Experimental Study on Loss Coefficient of Turbine Cascade with Incidence Angles (입사각의 변화에 따른 터빈 캐스케이드에서 손실계수에 관한 실험적 연구)

  • Lee, Ju-Hyung;Hur, Won-Hae;Jeon, Chang-Soo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.4 s.5
    • /
    • pp.48-56
    • /
    • 1999
  • For the study on loss coefficients of turbine cascade with variation of incidence angle, the wind-tunnel tests were performed under the ranges in velocity of 10 m/s, 15 m/s, 20 m/s and incidence angles from $-20^{\circ}\;to\;20^{\circ}$ by intervals of $5^{\circ}$. Comparing our results with Soderberg's prediction, differences in loss coefficient were $2.5\%\;and\;2.8\%$ each for 10 m/s and 15 m/s. A large disagreement of $30.3\%$ was showed at 20 m/s freestream velocity. The comparisons of these test results with Ainley's prediction showed an $8\%$ difference in the case of 20 m/s freestream velocity. Test results were approximately comparable with Ainley's loss prediction's in incidence angles. Generally, averaged total pressure loss seemed to be decreased as Reynolds number increased. The total pressure loss coefficients were increased parabolically, as incidence angles were increased negatively and positively from $0^{\circ}$, in all speed ranges. At the far low freestream velocities, minimum loss accurred between $-5^{\circ}\;and\;+5^{\circ}$. But this minimum range narrowed the location of this range by shifting to the direction of the angle as freestream velocity was increased.

  • PDF

Non-Invasive in vivo Loss Tangent Imaging: Thermal Sensitivity Estimation at the Larmor Frequency

  • Choi, Narae;Kim, Min-Oh;Shin, Jaewook;Lee, Joonsung;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.1
    • /
    • pp.36-43
    • /
    • 2016
  • Visualization of the tissue loss tangent property can provide distinct contrast and offer new information related to tissue electrical properties. A method for non-invasive imaging of the electrical loss tangent of tissue using magnetic resonance imaging (MRI) was demonstrated, and the effect of loss tangent was observed through simulations assuming a hyperthermia procedure. For measurement of tissue loss tangent, radiofrequency field maps ($B_1{^+}$ complex map) were acquired using a double-angle actual flip angle imaging MRI sequence. The conductivity and permittivity were estimated from the complex valued $B_1{^+}$ map using Helmholtz equations. Phantom and ex-vivo experiments were then performed. Electromagnetic simulations of hyperthermia were carried out for observation of temperature elevation with respect to loss tangent. Non-invasive imaging of tissue loss tangent via complex valued $B_1{^+}$ mapping using MRI was successfully conducted. Simulation results indicated that loss tangent is a dominant factor in temperature elevation in the high frequency range during hyperthermia. Knowledge of the tissue loss tangent value can be a useful marker for thermotherapy applications.

The Maximum Efficiency Driving in IPMSM by Precise Estimation of Current Phase Angle

  • Cho, Gyu-Won;Kim, Cheol-Min;Kim, Gyu-Tak
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1221-1226
    • /
    • 2013
  • In this paper, the equivalent circuit for the efficiency calculation by precise estimation of the linkage flux, inductance and iron loss resistance was calculated accurately. In addition, the driving characteristics according to the current phase angle are analyzed and the maximum efficiency point is calculated. And then, analyzed and experimental values of the efficiency were compared. So, causes of error were expected to be vibration and noise by harmonic distortion of the voltage and current, and mechanical loss of dynamometer. In addition, the driving characteristics according to the current phase angle are analyzed and the maximum efficiency point is calculated.

Development of Straightness, Roundness Measurement System for Standard Electrode of Loss Angle (손실각 표준기 전극의 진직, 진원도 측정시스템 개발)

  • 장종훈
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.198-203
    • /
    • 1998
  • To acquire the high precision of profile for standard electrode of loss angle, it is needed ultraprecision machining technology like MEAP(Magnetic Electronic Abrasive Polishing) and the very high profile measurement technology which can measure a micro unit about the workpiece. So, in this paper, it was developed the measurement system of precision of profile using non-contactable sensor that was approximate sensor of capacitance type, because that is better than others in the electrical characteristics. And standard electrode of loss angle was machined by the MEAP machining technology. In this study, it was development of precision measurement system. This system could be used measure the workpiece of roundness and straightness much more precise and faster than general mechanical measurement system done before. And it could be helped to minimize machining time and planning by very fast and precise measurement about the workpiece.

  • PDF

A study on the flow characteristics of non-Newtonian fluid flows in dividing tubes (분기관에서 비뉴턴 유체의 유동특성에 관한 연구)

  • 이행남;하옥남;전운학
    • Journal of Ocean Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.118-127
    • /
    • 1996
  • Flow patterns of fluid flow in dividing trbe were visualized, and the energy losses due to dividing were measured in laminar dividing flow of the viscoelastic fluid and its solution in tube junctions with dividing angles of $90^{\circ}$, $60^{\circ}$, $65^{\circ}$ and $15^{\circ}$. Two separation zones were observed. swelling of the streamline to the main tube or to lateral tube was observed. The sizes of the separation zones depend on the Reynolds number, the dividing angle and the dividing flow rate. The energy loss coefficients decrease with increasing Reynolds number, but their decreasing rate decreases with increasing Reynolds number as the sizes of the separation zone increase. The effect of dividing angle on the energy loss coefficients and separation is greater for main tube than for the lateral tube.

  • PDF

Enthalpy Flow Loss by Steady Mass Streaming in Pulse Tube Refrigerators (맥동관냉동기의 정상상태 질량흐름에 의한 엔탈피손실)

  • 백상호;정은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.7
    • /
    • pp.623-631
    • /
    • 2000
  • Effects of the taper angle and the angular velocity of a pulse tube on the enthalpy flow loss associated with the steady mass streaming were analysis by two-dimensional analysis of a pulse tube with variable cross-section. It was shown that the steady mass flux can lead to a large steady second-order temperature. The enthalpy flow loss associated with the steady mass streaming increases as the angular velocity increases. For a pulse tube where the viscous penetration depth is far thinner than the inner radius, the enthalpy flow loss can be significantly reduced by tapering the pulse tube since both the steady mass flux and the steady second-order temperature decrease as the taper angle increase.

  • PDF

A Study on the Flow Characteristics of a Butterfly Valve in Fire Protection (소화용 버터플라이 밸브의 유동특성에 관한 연구)

  • 이동명;김엽래
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.59-64
    • /
    • 2002
  • Investigation of flow characteristics on pressure loss and cavitations of the butterfly valve has been carried out. The pressure loss coefficient on opening angle of valve has been formulated by applying the Carnot's equations. Cavitations (such as cavitation Inception, super cavitation inception, cavitation damage inception, choking cavitation) have been predicted from the pressure loss coefficient of valve. The prediction of pressure loss and cavitation has been carried out change of the thickness ratio on opening angle of valve. The prediction data is utilize to necessary engineering data to develope of the butterfly valve.

Forced Convection Heat Transfer from an Inner Surface of a Two-Dimensional Rectangular Cavity (이차원 사각형 공동 내부에서의 강제 대류 열전달)

  • Seo, T.B.;Han, K.Y.;Kange, Y.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.4
    • /
    • pp.77-84
    • /
    • 2002
  • In order to investigate forced convection heat transfer due to the wind from the inner surface of a cavity receiver for a parabolic dish type solar energy collecting system, a two-dimensional rectangular cavity receiver is prepared and installed in a wind tunnel. The convection heat transfer coefficient of the inner surface of the receiver is dependent on the direction and the velocity of the wind. The attack angle of the cavity and the air velocity in the tunnel are controlled in a wide range so that the effects of the attack angle and the wind velocity on the heat transfer coefficient can be studied. The skirt is installed at the aperture of the cavity in order to reduce convective heat loss. The effects of the length and the installation angle of the skirt on convection heat transfer of the cavity are tested. It is found that convection heat loss can be significantly reduced by installing the skirt. Also, it is known that heat transfer from the cavity can be minimized if the angle of the skirt is $90^{\circ}$ to the outer surface of the cavity.

Evaluation of Loss Coefficient of a Butterfly Valve with Valve Closed Angles (밸브 닫힘각 변화에 따른 버터플라이밸브의 손실계수 평가)

  • Lee, Jee-Keun;Rho, Byung-Joon;Choi, Hee-Joo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.1
    • /
    • pp.14-21
    • /
    • 2008
  • In this study, flow characteristics of a small-sized butterfly valve with the valve disk diameter of 25.4 mm have been investigated experimentally for the valve closed angles. In order to examine the flow characteristics of the butterfly valve, loss coefficient (Kv) was obtained at the valve closed angles of 0$^{\circ}$, 5$^{\circ}$, 10$^{\circ}$, 20$^{\circ}$ and 30$^{\circ}$. In addition, the effects of the valve disk edge shape were examined. As the result of the experiment, the maximum loss coefficient (Kvmax) was decreased with the increase of the valve closed angle, and it had the maximum decrease ratio at the valve disk angles of 0$^{\circ}$~5$^{\circ}$. The valve disk edge shape have an effect on the loss coefficient of the valve around the small valve closed angle.