• 제목/요약/키워드: lose time

Search Result 262, Processing Time 0.031 seconds

Improvement of the Quality of Dried Wild Vegetables by Micro Oil Sprayed Thermal Air Technique

  • Yonghyun Kim;Yunmi Park;Chul-Woo Kim;Uk Lee;Hyun Ji Eo
    • Korean Journal of Plant Resources
    • /
    • v.35 no.6
    • /
    • pp.778-784
    • /
    • 2022
  • Wild vegetables, such as Cirsium setidens, and Aster scaber, are commonly distributed as dried materials because the wild vegetables lose their freshness quickly after harvest and distribution. Dried wild vegetables require rehydration to use as a food ingredient, and the quality of rehydrated wild vegetables is affected by pre-drying and drying methods. Here, we introduce the newly developed pre-drying and drying method, termed "micro oil sprayed thermal air (MOTA) technique". The three wild vegetables processed by the MOTA technique showed improved rehydration rate and reduced time to achieve maximum rehydration rate. Color characteristics were also improved in C. setidens. These results indicate that the MOTA technique improves the overall quality of rehydrated wild vegetables. It is expected that our findings could enhance the marketability of dried wild vegetables by improving overall quality and reducing preparation time.

Efficient FPGA Logic Design for Rotatory Vibration Data Acquisition (회전체 진동 데이터 획득을 위한 효율적인 FPGA 로직 설계)

  • Lee, Jung-Sik;Ryu, Deung-Ryeol
    • 전자공학회논문지 IE
    • /
    • v.47 no.4
    • /
    • pp.18-27
    • /
    • 2010
  • This paper is designed the efficient Data Acquisition System for an vibration of rotatory machines. The Data Acquisition System is consist of the analog logic having signal filer and amplifier, and digital logic with ADC, DSP, FPGA and FIFO memory. The vibration signal of rotatory machines acquired from sensors is controlled by the FPGA device through the analog logic and is saved to FIFO memory being converted analog to digital signal. The digital signal process is performed by the DSP using the vibration data in FIFO memory. The vibration factor of the rotatory machinery analysis and diagnosis is defined the RMS, Peak to Peak, average, GAP, FFT of vibration data and digital filtering by DSP, and is need to follow as being happened the event of vibration and make an application to an warning system. It takes time to process the several analysis step of all vibration data and the event follow, also special event. It should be continuously performed the data acquisition and the process, however during processing the input signal the DSP can not be performed to the acquisited data after then, also it will be lose the data at several channel. Therefore it is that the system uses efficiently the DSP and FPGA devices for reducing the data lose, it design to process a part of the signal data to FPGA from DSP in order to minimize the process time, and a process to parallel process system, as a result of design system it propose to method of faster process and more efficient data acquisition system by using DSP and FPGA than signal DSP system.

Test Time Reduction for BIST by Parallel Divide-and-Conquer Method (분할 및 병렬 처리 방법에 의한 BIST의 테스트 시간 감소)

  • Choe, Byeong-Gu;Kim, Dong-Uk
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.6
    • /
    • pp.322-329
    • /
    • 2000
  • BIST(Built-in Self Test) has been considered as the most promising DFT(design-for-test) scheme for the present and future test strategy. The most serious problem in applying BIST(Built-in Self Test) into a large circuit is the excessive increase in test time. This paper is focused on this problem. We proposed a new BIST construction scheme which uses a parallel divide-and-conquer method. The circuit division is performed with respect to some internal nodes called test points. The test points are selected by considering the nodal connectivity of the circuit rather than the testability of each node. The test patterns are generated by only one linear feedback shift register(LFSR) and they are shared by all the divided circuits. Thus, the test for each divided circuit is performed in parallel. Test responses are collected from the test point as well as the primary outputs. Even though the divide-and-conquer scheme is used and test patterns are generated in one LFSR, the proposed scheme does not lose its pseudo-exhaustive property. We proposed a selection procedure to find the test points and it was implemented with C/C++ language. Several example circuits were applied to this procedure and the results showed that test time was reduced upto 1/2151 but the increase in the hardware overhead or the delay increase was not much high. Because the proposed scheme showed a tendency that the increasing rates in hardware overhead and delay overhead were less than that in test time reduction as the size of circuit increases, it is expected to be used efficiently for large circuits as VLSI and ULSI.

  • PDF

The Recommendation of Sampling Method for Airborne MWF in Workplace - Correction for MWF Lost on PVC Filter - (작업환경 중 MWF 미스트와 증기에 대한 측정방법의 개발 - PVC 필터에 채취된 비수용성 MWF손실에 대한 보정 -)

  • Park, Dong-Wook;Kim, Shin-Bum;Shin, Chull-Im
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.2
    • /
    • pp.186-195
    • /
    • 1998
  • The objective of this study was to determine if MWF(metalworking fluids) mass sampled on PVC filter lose during flowing airstream and desiccating and to present direction to correct the underestimated MWF mass. Flowing airstream caused MWF sampled on PVC filter to be breakthrough and lost. Loss of MWF on PVC filter increased in proportion to time of flowing airstream. Meanwhile, loss of MWF was observed during desiccating without flowing airstream. Vapor pressure of MWF is so low that it would not normally be thought to evaporate. However, MWF mist sampled on PVC filter has so great a surface area that loss by flowing airstream and evaporation can be appreciable. Loss between fresh and used MWF was also different. Those study results mean that NIOSH method(#0500 method) to take airborne MWF mist with PVC filter is not valid. Media to sample airborne MWF accurately still have not been introduced. It seems to be needed to estimate how much MWF on PVC filter may be lost during sampling. Regression model between sampling time including 1 day desiccating and total loss of MWF was "Total loss(%)=18.4%+0.06 sampling time(p=0.000, r2=49.6%)". This model help correct MWF lost when one measures airborne MWF using NIOSH # 0500 method.

  • PDF

A Study on the Cabin's Noise Levels of Cargo-Passenger Ships plies South-West Coast line (서남 연근해 운항 정기화객선의 선내 소음에 관한 연구)

  • Yu, Young-Hun
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.05a
    • /
    • pp.207-212
    • /
    • 2006
  • The noise levels on board ship recognized at Europe in the early 1970s and the noise regulations on board ship began to put in a statutory form. After that, in 1982 "International Code on Noise Levels on Board Ships" adopted by IMO and it became standard to the newly built ship and remain so to this day. Especially, the ship engine room, which have huge main engine and various kinds of subsidiary machines, is under an extremely loud condition and so the worker who works in it is easy to lose his hearing. Recently, each nation regulates the allowable noise exposure time by law to protect the industrial employee from the occupational hardness of hearing. In our country, the allowable noise exposure time is regulated by the labor standard law but the international provisions regulated by IMO have been applied in case of the ship engine room. In this paper, the cabin's noise levels of cargo-passenger ships plies south-west coast line were investigated.

  • PDF

A study on the mitigation model development for minimizing the incidents of disk unit in information system's operational risks (디스크 장애예방을 위한 피해저감모델 개발에 관한 연구 - 정보시스템 운영리스크의 관점에서 -)

  • Hwang, Myung-Soo;Lee, Young-Jai
    • The KIPS Transactions:PartD
    • /
    • v.14D no.6
    • /
    • pp.689-700
    • /
    • 2007
  • Organizations and customers lose if business activities we discontinued by an incident of information systems under the current business environment because they pursue real time enterprise and on demand enterprise. The loss includes the intangible decline in brand image, customer separation, and the tangible loss such as decrease in business profits. Thus. it is necessary to have preparedness in advance and mitigation for minimization of a loss due to the business discontinuity and information system's operational risks. This paper suggests the mitigation model for minimizing the incidents of disk unit in information system's operational risks. The model will be represented by a network model which is composed of the three items as following: (1) causes, attributes, indicators of an operational risk, (2) a periodic time through an analysis of historical data, (3) an index or a regulation related to the examination of causes of an operational risk.

The Experimental Study on the Quinaldine(2-Methylquinoline) Toxicity for a Long Anaeathetization Period (장기 마취시 어류에 미치는 quinaldine 독성에 대한 기초 연구)

  • Yoon, Jong-Man;Lee, Jae-Hyun;Park, Hong-Yang
    • Journal of fish pathology
    • /
    • v.2 no.1
    • /
    • pp.37-44
    • /
    • 1989
  • This study was taken to induce either anaesthesia or sedation for the purpose of applying to transport of live fish safely. 7 species of fish in addition to Tilapia mossambica were exposed to 250 ppm concentration of the anaesthetic quinaldine to determine the safe level for handling and transportation of these species. The results obtained are as follows ; 1. The time taken to lose balance increased with a decrease on the concentration of the anaesthetic. 2. Anaesthetization must be carried out under temperature lower or higher rather than optimum temperature. 3. The longer the length of the fish, the longer the anaesthetization time and recovery time of fish. 4. Coefficient of recovery period and body length is 0.78. 5. At 10-15 min. after anaesthetization, the serum levels of glucose, ALP and SGOT were at peat. 6. LDH of the anaesthetized fish is much more increased than that of the unanaesthetized. 7. In the more 250 ppm treatment, the pyknosis of the brain and spleen tissue appeared.

  • PDF

The Impacts of Time-Varying Accessibility of Facilities on Housing Price Change by the Modified Repeat Sales Model - The Case of Subway Line 9 in Seoul - (수정반복매매모형을 활용한 시설접근성의 변화가 주택가격 변화에 미치는 영향 분석 - 지하철 9호선을 중심으로 -)

  • Sung, Hyun-Gun;Kim, Jin-Yo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3D
    • /
    • pp.477-487
    • /
    • 2011
  • The modified repeat-sales model is employed in this study in order to identify differentiating impacts of time-varying accessibility characteristics on housing price. The results demonstrate that accessibility measures have very differential impacts on housing price over time. The improvement of accessibility through newly built facilities and apartment complex has either increased or decreased housing price. For example, the new subway line 9 has positive impact on housing price nearby, therefore price gap between subway access area and the other parts has been increased. The impact of the wide area facilities such as shopping center and hospital are decreased because they can be used more easily by the new subway line before. However, the small service area facility such as elementary school doesn't lose their impact even though subway accessibility extremely increased. The results imply that new facilities in existing residential site can affect not only housing price but also the other facilities' impact of housing price.

Decoloring Effect of Viscose Rayon by Using Vapor Type Ozone Processing (오존 기상처리방법에 의한 비스코스 레이온의 탈색효과)

  • Kim, Gyoung-A;Lee, Mun-Soo
    • The Journal of Natural Sciences
    • /
    • v.10 no.1
    • /
    • pp.103-109
    • /
    • 1998
  • We studied on the decoloring effect of viscose rayon by vapor type ozone processing using ozone's strong oxidation. When ozone is generated, it becomes high concentration in vapor state, but in the insolving process with water, there are a lot of lose of ozone. As a result, a study using ozone in vapor-high concentration state is needed. So, in this paper, vapor type ozone processing is used unlike previous ozone treatment method-an aqueous solution method-to get a good effect from shortening the processing time. When vapor type ozone processing was directly treated to fabrics, high concentration ozone was generated then in a short time oxidized a dye existed in fabrics and finally decolored it. As vapor type ozone did not directly response to an organic dye, viscose rayon's decolorization was to be studied by changing pick up ratio(60%, 50%, 40%, 30%, 20%) using water as a medium. When pick up ratio of water was 40%, fabric's whiteness was improved but tensile strength and elongation were reduced. So 60 minutes was assumed as the most adjust time to minimize the reduction of fabric's tensile strength and elongation moreover of maximize the improvement of whiteness.

  • PDF

Design and Implementation of a Real-time Automatic Disaster and Information Broadcasting System (시뮬레이션 프로그램 기반 실시간 자동재난 및 안내방송시스템의 설계)

  • Lee, Byung-Mun;Park, Jung-In;Kang, Un-Gu
    • Journal of Digital Convergence
    • /
    • v.10 no.7
    • /
    • pp.141-152
    • /
    • 2012
  • The typical evacuation guidance system based on fire detectors, which is being widely used in theaters and large buildings, is often operated in an analog manner. In case of fire, it often causes the system to lose a wired line or wireless fire detection sensor, resulting in the difficulty of transmitting signals from a wired or wireless fire detection sensor to the main fire monitoring device. Accordingly, this paper has proposed the broadcasting system for disaster management, having an efficient evacuation guidance plan when a disaster occurs. The system reacts to an emergency situation along with fire alarm sirens in real time. We have implemented the above system by means of a simulation program that prints the evacuation guidance information (e.g., location and time of fire, and evacuation path) on an LCD located in a building through the fire sensor network in case of an emergency (e.g., actual fire). We have developed the simulation system by using mathematical algorithms, such as the optimal path search and the fire smoke diffusion algorithm. This simulation program considers the structure of a building and the location where the fire has initially occurred, applying it to the simulator.