• 제목/요약/키워드: long gauge sensors

검색결과 33건 처리시간 0.02초

Carbon fiber-based long-gauge sensors monitoring the flexural performance of FRP-reinforced concrete beams

  • Mohamed A. Saifeldeen;Nariman Fouad
    • Structural Monitoring and Maintenance
    • /
    • 제10권4호
    • /
    • pp.299-314
    • /
    • 2023
  • Long-gauge carbon fiber line (CFL) sensors have received considerable attention in the past decade. However, there is still a need for an in-depth investigation of their measuring accuracy. This study investigates the accuracy of carbon fiber line sensors to monitor and differentiate the flexural behavior of two beams, one reinforced with steel bars alone and the other reinforced with steel and basalt fiber-reinforced polymer bars. A distributed set of long-gauge carbon fiber line, Fiber Bragg Grating (FBG), and traditional strain gauge sensors was mounted on the tensile concrete surface of the studied beams to compare the results and assess the accuracies of the proposed sensors. The test beams were loaded monotonically under four-point bending loading until failure. Results indicated the importance of using long-gauge sensors in providing useful, accurate, and reliable information regarding global structural behavior, while point sensors are affected by local damage and strain concentrations. Furthermore, long-gauge carbon fiber line sensors demonstrated good agreement with the corresponding Fiber Bragg Grating sensors with acceptable accuracy, thereby exhibiting potential for application in monitoring the health of large-scale structures.

장대 광변형 센서의 건설 구조물 적용 (Application of Long Gauge Fiber Optic Sensors to Construction Engineering Structures)

  • 로드테니슨;안명운;김상환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 정보화시공 학술발표회
    • /
    • pp.61-78
    • /
    • 2001
  • Various kind of fiber optic gauge sensors are available that can be bonded to civil engineering structures such as bridges, dams, tunnels and pipelines. A new fiber optic long gauge has significant advantages over other fiber optic sensors. These gauges can vary in length from less than 10 cm up to 30 m and provide the structural engineer with accurate measurements of displacement. These displacements can be converted to strains by dividing the measurement by the long gauge length. Using new optical technology, the long gauge instrument developed by FOX-TEK can choose max. 30 meters of gauge length so as to measure the very early stress/strain correlation curve. And this gauge length to be extended up to 100 meter in 2002.

  • PDF

긴 게이지길이 광섬유 FBG센서를 이용한 교각상부 거동 혹정 (Displace Measurement of the Top of Bridge Pier Using Long gauge Fiber Optic Sensor)

  • 김기수
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.71-76
    • /
    • 2006
  • In this paper, a long gauge Fiber Bragg Grating (FBG) sensor system is described and long gauge FBGs are well, suited for measuring the upper parts of the bridge piers under the extremely severe movement conditions. In the experiments, we used more than 30m long FBG sensors to measure the movement of top part of the bridge piers which are separated from the main bridge by cutting the decks. With the actuator, the deck and girders were pushed and released. We checked the movement of the top of the pier while releasing the pressure of the actuator with the long gauge fiber sensor. In order to measure the movement of the upper part of the pier, the reference point must be outside of the pier. Using the optical fiber sensors, one end of the sensor is attached to the top of the pier and the other end is attached to the bottom of the next pier. The fiber sensors showed good response to the release loading and we could calculate the movement of the top part of the pear.

  • PDF

Long-gauge 광섬유 센서를 이용한 철도교 PSC 거더의 처짐유추 (Deflection Estimation of a PSC Railroad Girder using Long-gauge Fiber Optic Sensors)

  • 정원석;김성일;김남식;이희업
    • 한국철도학회논문집
    • /
    • 제9권4호
    • /
    • pp.467-472
    • /
    • 2006
  • This paper deals with the applicability of long-gauge deformation fiber optic sensors (FOS) to prestressed concrete structures. A main motivation is the desire to monitor the deflection of the railway bridges without intervenes of the signal intensity fluctuations. A 25 m long, 1.8 m deep PSC girder was fabricated compositely with 22 cm thick reinforced concrete deck. Two pairs of 3 m long-gauge sensors are attached to the prestressed concrete girder with parallel topology. Using the relationship between curvature and vortical deflection and the quadratic regression of curvatures at the discrete point, it is possible to extrapolate the deflection curve of the girder. The estimated deflection based on the developed method is compared with the results using conventional strain gauges and LVDTS. It has been demonstrated that the proposed instrumentation technique is capable of estimating the vertical deflection and neutral axis position of the prestressed concrete girder up to weak nonlinear region.

Optimal layout of long-gauge sensors for deformation distribution identification

  • Zhang, Qingqing;Xia, Qi;Zhang, Jian;Wu, Zhishen
    • Smart Structures and Systems
    • /
    • 제18권3호
    • /
    • pp.389-403
    • /
    • 2016
  • Structural deflection can be identified from measured strains from long gague sensors, but the sensor layout scheme greatly influences on the accuracy of identified resutls. To determine the optimal sensor layout scheme for accurate deflection identification of the tied arch bridge, the method of optimal layout of long-gauge fiber optic sensors is studied, in which the characteristic curve is first developed by using the bending macro-strain curve under multiple target load conditions, then optimal sensor layout scheme with different number of sensors are determined. A tied arch bridge is studied as an example to verify the effectiveness and robustness of the proposed method for static and dynamic deflection identification.

광섬유 스마트 구조물의 개념을 이용한 교량상부 내진거동 측정 (Earthquake Movement Measurement of the Top of Bridge Pier Using Fiber Optic Smart Structure Concept)

  • 김기수;한인동
    • Composites Research
    • /
    • 제19권3호
    • /
    • pp.43-49
    • /
    • 2006
  • In this paper, a long gauge Fiber Bragg Grating (FBG) sensor system is described and long gauge FBGs are well-suited for measuring the upper parts of the bridge piers under the extremely severe movement conditions. In the experiments, we used more than 30m long FBG sensors to measure the movement of top part of the bridge piers which are separated from the main bridge by cutting the decks. With the actuator, the deck and girders were pushed and released. We checked the movement of the top of the pier while releasing the pressure of the actuator with the long gauge fiber sensor. In order to measure the movement of the upper part of the pier, the reference point must be outside of the pier. Using the optical fiber sensors, one end of the sensor is attached to the top of the pier and the other end is attached to the bottom of the next pier. The fiber sensors showed good response to the release loading and we could calculate the movement of the top part of the pear.

LGFOS를 이용한 보-기둥 부재의 부재력 계측 기법 개발 (Stress Measuring Method for Beam-Column Members with Long Gauge Fiber Optic Sensors)

  • 박효선;백재민;이홍민
    • 한국방재학회 논문집
    • /
    • 제6권3호
    • /
    • pp.9-16
    • /
    • 2006
  • 기존 대부분의 구조물 건전도 모니터링 시스템에서는 제한적인 위치와 범위에서의 변형률 계측이 가능한 국부 변형률 센서를 이용하여 구조물 또는 구조 부재의 부재력을 계측하고 이에 기반하여 구조 안전성을 평가하고 있다. 그러나 실 구조물의 부재력 계측을 통한 안전성 평가는 하중의 크기 및 분포에 대한 불확실성 등의 다양한 이유로 부재 내 최대응력 작용점을 정확하게 파악하기 어렵다. 이러한 경우 구조물의 사이즈에 비하여 센서의 길이가 미소한 국부 변형률 센서를 이용한 안전성 평가의 적절성은 센서의 위치 및 개수에 좌우되는 한계를 가지게 된다. 이러한 한계를 극복하기 위하여 센서의 수를 증가시키면 처리해야하는 데이터의 양과 비용이 증가하게 되므로 현실적인 적용성에 문제점을 가지게 된다. 그러므로 본 연구에서는 이러한 한계와 문제점을 극복할 수 있는 대안으로 장대광변형센서에 의한 평균변형률을 이용한 보-기둥의 부재력 계측 기법을 제시하였다.

긴 게이지 길이 광섬유 격자 센서의 측정과 응용 (A Study on the Measurement and Application of Long Gauge fiber Brags Grating Sensors)

  • 김기수
    • 비파괴검사학회지
    • /
    • 제25권5호
    • /
    • pp.343-349
    • /
    • 2005
  • 광섬유 브래그 격자(fiber Bragg grating, FBC)는 1989년 Melts의 실험이후 광통신 분야 및 센서 분야에 다양한 용도를 가지고 있다. 이를 이용하여 광섬유 레이저, 대역 통과 필터로 사용하거나, 여러 가지 물리량을 측정하기 위한 온도, 변형률, 변위센서 등에 응용할 수 있다. 특히 본 연구에서는 기존 센서가 가지지 못한 긴 게이지 길이에서의 측정을 위해서 광섬유 센서 정적 시스템(FBG Static Logger)과 FBG 센서가 포함된 긴 길이의 광섬유를 이용하여 장대 구조물의 변형이나 외부 reference의 상대변위를 길게 연결하여 측정하기 쉽지 않은 변위를 측정하여 구조물의 상황을 상시 점검하고 더 나아가 잔존수명을 예측하고 보수시기를 알려줄 수 있는 방법을 모색하여 FBG. 센서의 패키지(package)를 고안하였다. 이를 통해 효율적인 장거리 변위 측정방법을 정립하고 이를 원자력 격납구조물에 적용하여 성공적으로 측정함으로써 광섬유 격자센서를 이용하여 50m 이상의 장거리 계측의 가능성을 보여 주었다.

Damage detection on output-only monitoring of dynamic curvature in composite decks

  • Domaneschi, M.;Sigurdardottir, D.;Glisic, B.
    • Structural Monitoring and Maintenance
    • /
    • 제4권1호
    • /
    • pp.1-15
    • /
    • 2017
  • Installation of sensors networks for continuous in-service monitoring of structures and their efficiency conditions is a current research trend of paramount interest. On-line monitoring systems could be strategically useful for road infrastructures, which are expected to perform efficiently and be self-diagnostic, also in emergency scenarios. This work researches damage detection in composite concrete-steel structures that are typical for highway overpasses and bridges. The techniques herein proposed assume that typical damage in the deck occurs in form of delamination and cracking, and that it affects the peak power spectral density of dynamic curvature. The investigation is performed by combining results of measurements collected by long-gauge fiber optic strain sensors installed on monitored structure and a statistic approach. A finite element model has been also prepared and validated for deepening peculiar aspects of the investigation and the availability of the method. The proposed method for real time applications is able to detect a documented unusual behavior (e.g., damage or deterioration) through long-gauge fiber optic strain sensors measurements and a probabilistic study of the dynamic curvature power spectral density.

철도교 상시계측시스템의 교정 및 교정상수 설정에 관한 연구 (Calibration of Health Monitoring System installed in the Railway Bridges)

  • 박준오;이준석;최일윤;민경주
    • 한국철도학회논문집
    • /
    • 제5권3호
    • /
    • pp.148-157
    • /
    • 2002
  • A health monitoring system becomes a useful tool to obtain information on long term behavior of the important railway structures such as very long span and special type bridges. The health monitoring system not only gives the direct measurement data of the railway bridges but also provides the basic data on the maintenance of the structures. Therefore, periodic calibrations of the health monitoring system will be a necessary step toward precise and accurate assessment of the railway bridges. In this study, the calibration and gauge factor readjustment process made for the health monitoring system installed in the railroad bridges is reviewed and some findings are explained in detail: specifically, the calibrators made for this purpose are illustrated and the regression processes of the calibration on long-term displacement using water level sensor, longitudinal displacement using LVDT sensor, instantaneous displacement using LVDT sensors and accelerometer are described in full length. Based on the regression results, it was found that the gauge factors need to be readjusted according to the regression equation but, since the deviation or shift is not serious so far, long-term observation on each sensor is also recommended. Future work will be concentrated on the long-term analysis of each sensor and on the database creation so that the assessment of the structures is possible.