• Title/Summary/Keyword: location of the bar

Search Result 139, Processing Time 0.036 seconds

Displacement Measurement of Structure using Multi-View Camera & Photogrammetry (사진측량법과 다시점 카메라를 이용한 구조물의 변위계측)

  • Yeo, Jeong-Hyeon;Yoon, In-Mo;Jeong, Young-Kee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.1141-1144
    • /
    • 2005
  • In this paper, we propose an automatic displacement system for testing stability of structure. Photogrammetry is a method which can measure accurate 3D data from 2D images taken from different locations and which is suitable for analyzing and measuring the displacement of structure. This paper consists of camera calibration, feature extraction using coded target & retro-reflective circle, 3D reconstruction and analyzing accuracy. Multi-view camera which is used for measuring displacement of structure is placed with different location respectively. Camera calibration calculates trifocal tensor from corresponding points in images, from which Euclidean camera is calculated. Especially, in a step of feature extraction, we utilize sub-pixel method and pattern recognition in order to measure the accurate 3D locations. Scale bar is used as reference to measure. the accurate value of world coordinate..

  • PDF

Influence of Transverse Reinforcement Elements for Flexural Strength of Lap Spliced Ultra-high-strength Reinforced Concrete Beams (겹침이음된 초고강도콘크리트 보의 휨강도에 횡방향보강 요소가 미치는 영향)

  • Bae, Baek-Il;Choi, Hyun-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.135-142
    • /
    • 2022
  • In this study, lap spliced ultra-high strength reinforced concrete beams were tested and the code criteria for calculating the lap splice length which was affected by the transverse reinforcement and concrete covering performance were reviewed. The main variables for test were set as fiber volume fraction and transverse reinforcing bar arrangement to improve the confining performance of the concrete cover. The change of the confining performance of concrete cover according to the increase in the fiber mixing amount at 1% and 2% volume ratio was examined, and D10 stirrups with a spacing of 100 mm were placed in the lap spliced region. As a result of the test, the specimens confined by the stirrups showed a sudden drop of load bearing capacity with horizontal cracking at the position of tensile longitudinal reinforcement. However, horizontal cracks were not appeared at the location of longitudinal reinforcement for the specimens with steel fiber. And these specimens showed gradual decrease of load bearing capacity after experiencing peak load. In particular, it was found that the strain at the position of the tensile longitudinal reinforcements of the specimens to which the mixing ratio of 2% was applied exceeds the yield strain. As a result of measuring the strain on the concrete surface, it was found that the fiber was more effective in preventing damage to the concrete surface than the stirrups for short lap spliced region.

The Effect of Form Factors and Control Types on Unsorted List Search for Full Touch Phone

  • Lee, Jong-Kee;Park, Jae-Kyu;Kim, Jun-Young;Choe, Jae-Ho;Jung, Eui-S.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.2
    • /
    • pp.309-317
    • /
    • 2012
  • Objective: The aim of this paper is to inquire into the influences form factors and control types affect a search time and comfort at list menu of full touch phone. Background: Various studies have been proceeded that are related to the optimum touch area for enhancing usability of control and legibility in mobile touch device. In the environment of list menu which is widely used to provide various information effectively, however, not only comprehensive consideration for legibility and control is to be seek but also research for control type which is to scroll a list. Method: This study executed form factor experiment to inquire into the influence that font size, height of row and fixed area affect searching time and comfort in the while information processing even if the information on the list is unsorted in alphabetical order. Among the result of form factor experiment, control type experiment was executed by selecting shortest performance time, highest legibility comfort and control comfort. Control type experiment was implemented to figure out the influence which existing flicking type, scrolling bar type, newly established button page type and button raw types affect performance time and subjective comfort depending on location of the information. Results: Font size 12pt, height of row 7mm and fixed area 15mm was shortest performance time and got highest comfort and legibility score in form factor experiment. A Button page which was newly proposed type was shortest performance time and got highest comprehensive comfort in control type experiment. Conclusion: Form factor experiment showed similar results with the study through reading a long passage of character or controlling a grid icon type. However, height of row turned out to affect not only touch area for control but also legibility by ruling space between the lines. Button page type which was newly proposed showed shortest performance time and got highest comprehensive comfort. Because Button page type needs few finger movements than other control types and implements search in the fixed form, unlikely other type which list keeps moving. Application: This study should be applied in deciding form factors and control type for scroll when designing a list menu of full touch phone.

Influence of Bubble Sheet Applying Methods on Temperature of Exposed Joint Rebar at Wall Surface of Load-Bearing Wall Structure Building During Winter (동절기 벽식구조 건축물 벽부분의 버블시트 포설방법 변화가 이음부 노출철근의 온도에 미치는 영향)

  • Han, Cheon-Goo;Lee, Jea-Hyeon;Kim, Min-Sang
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.2
    • /
    • pp.149-155
    • /
    • 2017
  • In this research, the surface covered curing method using the double-layered bubble sheet was evaluated. This double-layered bubble sheet has outstanding insulating performance with its low heat conductivity and high economic feasibility with its high durability. However, in the case of wall-typed building construction, the area of exposed rebar is curious on curing performance with the double-layered bubble sheet in spite of the double-layered bubble sheet showed favorable performance for slab. Therefore, in this research, regarding the actually constructed wall-typed apartment building, the most efficient curing method was suggested based on the evaluation of curing performance depending on temperature distribution depending on various location of covered or exposed rebar. As a result, the D method was determined as the most efficient curing method without any concern of early-age frost damage. However, by considering easiness of construction, the B method of covering the pieced double-layered bubble sheet on gap between rebars can be another option of desired result.

Seismic Performance of Hollow Rectangular Precast Segmental Piers (프리캐스트 중공 사각형 철근콘크리트 교각의 내진성능)

  • Lee, Jae-Hoon;Park, Dong-Kyu;Choi, Jin-Ho;Shin, Sung-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.705-714
    • /
    • 2012
  • Precast reinforced concrete bridge columns with hollow rectangular section were tested under cyclic lateral load with constant axial force to investigate its seismic performance. After all the precast column segments were erected, longitudinal reinforcement was inserted in the sheath prefabricated in the segments, which were then mortar grouted. Main variables of the test series were column aspect ratio, longitudinal reinforcement ratio, amount of lateral reinforcement, and location of segment joints. The aspect ratios were 4.5 and 2.5, and the longitudinal steel ratios were 1.15% and 3.07%. The amount of lateral reinforcement were 95%, 55%, 50%, and 27% of the minimum amount for full ductility design requirements in the Korean Bridge Design Code. The locations of segment joints in plastic hinge region were 0.5 and 1.0 times of the section depth from the bottom column end. The test results of cracking and failure mode, axial-flexural strength, lateral load-displacement relationship, and displacement ductility are presented. Then, safety of the ductility demand based seismic design in the Korean Bridge Design Code is discussed. The column specimens showed larger ductility than expected, because buckling of longitudinal reinforcing bar was prevented due to confinement developed not only by transverse steel but also by sheath and infilling mortar.

Secure Mutual Authentication Protocol for RFID System without Online Back-End-Database (온라인 백-엔드-데이터베이스가 없는 안전한 RFID 상호 인증 프로토콜)

  • Won, Tae-Youn;Yu, Young-Jun;Chun, Ji-Young;Byun, Jin-Wook;Lee, Dong-Hoon
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.20 no.1
    • /
    • pp.63-72
    • /
    • 2010
  • RFID is one of useful identification technology in ubiquitous environments which can be a replacement of bar code. RFID is basically consisted of tag, reader, which is for perception of the tag, and back-end-database for saving the information of tags. Although the usage of mobile readers in cellular phone or PDA increases, related studies are not enough to be secure for practical environments. There are many factors for using mobile leaders, instead of static leaders. In mobile reader environments, before constructing the secure protocol, we must consider these problems: 1) easy to lose the mobile reader 2) hard to keep the connection with back-end-database because of communication obstacle, the limitation of communication range, and so on. To find the solution against those problems, Han et al. suggest RFID mutual authentication protocol without back-end-database environment. However Han et al.'s protocol is able to be traced tag location by using eavesdropping, spoofing, and replay attack. Passive tag based on low cost is required lots of communication unsuitably. Hence, we analyze some vulnerabilities of Han et al.'s protocol and suggest RFID mutual authentication protocol without online back-end-database in aspect of efficiency and security.

Shear Strength Prediction of FRP RC Baem without Shear Reinforcements (전단 보강이 없는 FRP RC보의 전단강도 예측)

  • Lee, Jae-Hoon;Shin, Sung-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.313-324
    • /
    • 2010
  • There are many problems in application of FRP reinforcing bars as shear reinforcement, since bending of FRP bars is not a feasible process on construction site. Even though FRP bars can be manufactured in bent shape, they have lower strength at bent location. However, there are no serious problems to use FRP bars as flexural reinforcement. Plates or slabs like bridge decks, in general, do not need shear reinforcements. These types of members with FRP flexural reinforcement have lower shear strength than those with conventional steel flexural reinforcement. However, reliable process or equation for shear strength estimation of FRP reinforced concrete without shear reinforcement are not established, yet. In this study, predicted shear strength obtained from available design equations and assessment equations are compared with 211 experimental results. The results showed that among the current design codes, the Architectural Institute of Japan (AIJ) and the Institution of Structural Engineers (ISE) provided the best estimation. ACI 440.1R-06 provided conservative results with degree of dispersion similar to that of ISE. In addition, regression analysis on the collected experimental results was conducted to develop regression models. As a result, a new reliable shear strength equation was proposed.

Development of Patient-Immobilizing Device for Total Body Irradiation (TBI) (전신 방사선치료(Total Body Irradiation, TBI)를 위한 한국인에 맞는 환자 고정장치에 관한 연구)

  • 김명세
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.114-119
    • /
    • 2002
  • A immobilizing device that is essential for correct lung and lens shielding with homogenous dose distribution in fractionated total body irradiation was developed and it's efficiency was evaluated. The main frame was made of stainless steel bar (5 cm in diameter) to withstand up to 230 cm in height and 100 kg in weight to prevent any injury even in unconsciousness condition. The saddle was designed to adjust the body weight and hight of standing patients. Chest and back supporter were made of 1 cm acryl which could fix the lung block and cassette holder. Leather and sponge pedding were used for head rest to keep patients comfortable. The device was strongly fixed by specially designed bolts on the bottom panel which was made of 1 cm stainless steel and 10 cm thick wooden board. Precise manipulation ($\pm$2 mm) was possible by upper two pulleys and side handles. Average four minutes twenty five seconds were needed for exact setting in fractionated TBI. No significant difference of lung block location on repeated verification films was confirmed and relatively homogeneous dose distribution was measured in rando phantom experiments and patient treatments ($\pm$5%). This immobilizing device was very efficient to keep correct position of patients, which is essential for better result and less complication in fractionated TBI.

  • PDF

Assessment of Liquefaction Potential Using Correlation between Shear Wave Velocity and Normalized LPI on Urban Areas of Seoul and Gyeongju (정규화LPI와 전단파 속도의 상관관계를 활용한 서울과 경주 지역 액상화 위험도 평가)

  • Song, Young Woo;Chung, Choong Ki;Park, Ka Hyun;Kim, Min Gi
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.2
    • /
    • pp.357-367
    • /
    • 2018
  • Recent earthquakes in Gyeongju and Pohang have raised interest in liquefaction in South Korea. Liquefaction, which is a phenomenon that excessive pore pressure is generated and the shear strength of soil is decreased by repeated loads such as earthquakes, causes severe problems such as ground subsidence and overturning of structures. Therefore, it is necessary to identify and prepare for the possibility of liquefaction in advance. In general, the possibility of liquefaction is quantitatively assessed using the Liquefaction Potential Index (LPI), but it takes a lot of time and effort for performing site response analysis which is essential for the liquefaction evaluation. In this study, a simple method to evaluate the liquefaction potential without executing the site response analysis in a downtown area with a lot of borehole data was proposed. In this simple method, the correlation between the average shear wave velocity of the target location ground and the LPI divided by thickness of liquefiable layer was established. And the applicable correlation equation for various rock outcrop accelerations were derived. Using the 104 boreholes information in Seoul, the correlation equation between LPI and the shear wave velocity (ground water level: 0m, 1m, 2m, 3m) is obtained and the possibility of liquefaction occurrence in Seoul and Gyeongju is evaluated. The applicability of the proposed simple method was verified by comparing the LPI values calculated from the correlation equation and the LPI values derived using the existing site response analysis. Finally, the distribution map of LPI calculated from the correlation was drawn using Kriging, a geostatistical technique.