• 제목/요약/키워드: local vibration

검색결과 506건 처리시간 0.028초

중속 디젤엔진 국부 구조물의 진동저감 연구 (A Study on Vibration Reduction of Local Structure of Medium-speed Diesel Engine)

  • 정건화;이준호;손정호;류영석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.257-261
    • /
    • 2011
  • The failures of local structure of marine medium-speed diesel engine occurred in durability test. The vibration response of the whole engine was in an acceptance level, but the local structures were broken. ODS test and vibration measurement were carried out in order to investigate the root cause of durability problem. These tests revealed that the root cause of failures was excessive vibration by $4.5^{th}$ resonance between engine body and local structure. The best solution to reduce the vibration response is to change the type of mount. After a rigid mount was replaced by a flexible mount, maximum vibration level dropped to 72%.

  • PDF

대형철골구조물의 효율적인 국부진동해석 (Efficient Local Vibration Analysis of Large Steel Frames)

  • 이동근;송종걸;정길영;김우범
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1994년도 봄 학술발표회 논문집
    • /
    • pp.105-112
    • /
    • 1994
  • In a local vibration analysis of a large steel frame, a large eigenvalue problem results. Due to computer storage and the expense of a complete solution, it is desirable to minimize the size of the resulting matrices. A new and efficient method of local vibration analysis for large steel frames is presented. It reduces the order of dynamic matrices by dynamic condensation method. Examples are given for local vibration of a plane frame. Results are compared to the complete solution of the full eigenvalue problem.

  • PDF

급성 요통에 대한 국소진동 자극의 영향 (Influence of Local Vibratory Stimulation of Acute Low Back Pain)

  • 강종호;방현수;천송희;박수진;김진상
    • 대한물리의학회지
    • /
    • 제2권2호
    • /
    • pp.135-142
    • /
    • 2007
  • Purpose : To investigate the effectiveness of local vibration and interferential therapy for patient with acute low back pain. Methods : A randomized trial designed to compare interferential therapy and local vibration therapy for acute low back pain in primary care setting Results : A total of 60 patients were recruited. The two treatment groups had similar demographic and clinical baseline characteristics. The mean VAS scores before treatment was 8.290 for interferental therapy group and 8.572 for local vibration therapy groups. After treatment, this VAS score had dropped to 4.812(interferental therapy group, at 7 days), and 4.945(local vibration group, at 7 days). Conclusion : This study shows a progressive fall in visual analog scale scores in patients with acute low back pain treated with either interferential therapy and local vibration therapy. There was some difference in the improvement between the two groups at 1 to 4 days, VAS score of vibration therapy groups was low better than interferential therapy groups.

  • PDF

Effect of Local Vibration on Triceps Surae Flexibility Compared to Static Stretching

  • Park, Seol
    • The Journal of Korean Physical Therapy
    • /
    • 제32권4호
    • /
    • pp.245-249
    • /
    • 2020
  • Purpose: This study examined the effects of local vibration using a massage gun on the triceps surae flexibility by measuring the ankle dorsiflexion range of motion (ROM) compared to static stretching in healthy adults. Methods: Twenty healthy subjects were instructed in this study. They were allocated randomly to two groups: local vibration (LV) and static stretching (SS). The ankle dorsiflexion ROM was measured before and after the intervention in supine (open kinetic chain, OKC) and standing (closed kinetic chain, CKC). The LV group received local vibration using a massage gun for five minutes on their triceps surae, and the SS group stood on the Q board with a dorsiflexed ankle for five minutes. The ROM between pre- and post-intervention and the change in ROM between two groups were analyzed. A paired t-test was used to compare the ROM between pre- and post-intervention, while an independent t-test was used to compare the change in ROM between the two groups. Results: Both groups showed a significant difference between pre- and post-intervention in the position of both the OKC and CKC. The change in ROM, however, was not significantly different between the two groups. Conclusion: The application of local vibration using a massage gun for five minutes on the triceps surae could improve its flexibility as much as the application of static stretching. A massage gun for the application of a local vibration stimulus may be effective, simple, portable, and comfortable.

Damage identification of belt conveyor support structure using periodic and isolated local vibration modes

  • Hornarbakhsh, Amin;Nagayama, Tomonori;Rana, Shohel;Tominaga, Tomonori;Hisazumi, Kazumasa;Kanno, Ryoichi
    • Smart Structures and Systems
    • /
    • 제15권3호
    • /
    • pp.787-806
    • /
    • 2015
  • Due to corrosion, a large number of belt conveyors support structure in industrial plants have deteriorated. Severe corrosion may result in collapse of the structures. Therefore, practical and effective structural assessment techniques are needed. In this paper, damage identification methods based on two specific local vibration modes, named periodic and isolated local vibration modes, are proposed. The identification methods utilize the facts that support structures have many identical members repeated along the belt conveyor and there exist some local modes within a small frequency range where vibrations of these identical members are much larger than those of the other members. When one of these identical members is damaged, this member no longer vibrates in those modes. Instead, the member vibrates alone in an isolated mode with a lower frequency. A damage identification method based on frequencies comparison of these vibration modes and another method based on amplitude comparison of the periodic local vibration mode are explained. These methods do not require the baseline measurement records of undamaged structure. The methods is capable of detecting multiple damages simultaneously. The applicability of the methods is experimentally validated with a laboratory model and a real belt-conveyor support structure.

전역탐색법을 이용한 선박 국부구조물의 최적설계 (Optimum Design of Local Structure in Ship Based on Global Search Method)

  • 공영모;최수현;송진대;양보석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.416-420
    • /
    • 2004
  • Recently, the importance of vibration reduction at the local structure such as tank, deck which attached machinery and compass deck, has continuously increased by owner and shipbuilder. Because crews are afflicted with them and severe vibration problems affect on the crack of structure. This study conducted optimum design to get a stiffener size of local structure to reducing the vibration level and dec leasing the weight of structure in ship. Random tabu search method (R-Tabu) has fast converging time and can search variables size domains for nonlinear problems. This paper used Nastran external call type independence optimization method which makes using a solver module from Nastran.

  • PDF

Analysis of local vibrations in the stay cables of an existing cable-stayed bridge under wind gusts

  • Wu, Qingxiong;Takahashi, Kazuo;Chen, Baochun
    • Structural Engineering and Mechanics
    • /
    • 제30권5호
    • /
    • pp.513-534
    • /
    • 2008
  • This paper examines local vibrations in the stay cables of a cable-stayed bridge subjected to wind gusts. The wind loads, including the self-excited load and the buffeting load, are converted into time-domain values using the rational function approximation and the multidimensional autoregressive process, respectively. The global motion of the girder, which is generated by the wind gusts, is analyzed using the modal analysis method. The local vibration of stay cables is calculated using a model in which an inclined cable is subjected to time-varying displacement at one support under global vibration. This model can consider both forced vibration and parametric vibration. The response characteristics of the local vibrations in the stay cables under wind gusts are described using an existing cable-stayed bridge. The results of the numerical analysis show a significant difference between the combined parametric and forced vibrations and the forced vibration.

Hybrid vibration-impedance monitoring in prestressed concrete structure with local strand breakage

  • Dang, Ngoc-Loi;Pham, Quang-Quang;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • 제30권5호
    • /
    • pp.463-477
    • /
    • 2022
  • In this paper, a hybrid vibration-impedance-based damage monitoring approach is experimentally evaluated for prestressed concrete (PSC) structures with local strand breakage. Firstly, the hybrid monitoring scheme is designed to alert damage occurrence from changes in vibration characteristics and to localize strand breakage from changes in impedance signatures. Secondly, a full-scale PSC anchorage is experimented to measure global vibration responses and local impedance responses under a sequence of simulated strand-breakage events. Finally, the measured data are analyzed using the hybrid monitoring framework. The change of structural condition (i.e., damage extent) induced by the local strand breakage is estimated by changes in a few natural frequencies obtained from a few accelerometers in the structure. The damaged strand is locally identified by tomography analysis of impedance features measured via an array of PZT (lead-zirconate-titanate) sensors mounted on the anchorage. Experimental results demonstrate that the strand breakage in the PSC structure can be accurately assessed by using the combined vibration and impedance features.

철도 차량용 주름 판재의 국부진동 모드 (Local Vibration Modes of Corrugated Panels for Rail Road Vehicles)

  • 김석현;장호식
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.527-534
    • /
    • 2000
  • Characteristics of local vibration modes of a corrugated panel are investigated by finite element analysis and modal testing. Structural modification model in the corrugation is proposed to increase the resonance frequency. This model decreases the fall by the local resonance in the transmission loss of the corrugated pallet and improves sound insulation performance. Damping effect of tile foam filled ill tile core cavity is also estimated by experiment The results of tile study offer useful information how to predict the severe local resonances in corrugations and how to prevent their undesirable effect ell the sound insulation and the vibration transmission.

  • PDF

선박 국부구조의 공진응답 저감을 위한 동흡진기 최적 설계 방법 (Optimal Design Method of Dynamic Vibration Absorber to Reduce Resonant Vibration Response of Ship Local Structure)

  • 권혁;조대승
    • 대한조선학회논문집
    • /
    • 제59권3호
    • /
    • pp.134-140
    • /
    • 2022
  • Ship local structure sometimes experiences severe vibration due to the resonance with an excitation force generated by the propulsion system. In that case, the installation of dynamic vibration absorber such as Tuned Mass Damper (TMD) on the structure can be considered as an effective alternative countermeasure to reduce the troublesome vibration if structural modification or change of excitation frequencies is difficult. Meanwhile, the conventional optimal design method of TMD premises the target structure exposed on an excitation force without the constraint of its magnitude and frequency range. However, the frequencies of major ship excitation forces due to propulsion system are normally bounded and its magnitude is varied according to its operation speed. Hence, the optimal design of TMD to reduce the resonant vibration of ship local structure should be differently approached compared with the conventional ones. For the purpose, this paper proposes an optimal design method of TMD considering maximum frequency and magnitude variation of a target harmonic excitation component. It is done by both lowering the resonant response at the 1st natural frequency and locating the 2nd natural frequency over maximum excitation frequency for the idealized 2 degree of freedom system consisted of the structure and the TMD. For the validation of the proposed method, a numerical design case of TMD for a ship local structure exposed on resonant vibration due to a propeller excitation force is introduced and its performance is compared with the conventionally designed one.