• Title/Summary/Keyword: local mass

Search Result 1,239, Processing Time 0.027 seconds

A Comparative Study on Food Habits and Nutrient Intakes with Body Mass Index of Hypertensive Patients commuting to a Local Health Center (지역사회 고혈압 환자의 비만도에 따른 식습관 , 영양상태 및 고혈압관리 실태)

  • Jo, Gyeong-Ok;Gwon, Sang-Hui
    • Journal of the Korean Dietetic Association
    • /
    • v.8 no.2
    • /
    • pp.185-198
    • /
    • 2002
  • The purpose of this study was to compare food habits and nutrient intakes with body mass index of hypertensive patients commuting to a Local Health Center. A total of 85 patients were divided into two groups according to BMI. The non-obese group comprised 43 subjects with BMI below 25㎏/$m^2$ , while the obese group comprised 42 subjects with BMI above 25㎏/$m^2$ . All Subjects were interviewed for general characteristics, food habits, clinical characteristics, effort for health maintenance and the knowledge of hypertension and nutrition. Anthropometric assessments such as weight, height, waist-hip ratio and biochemical measurement of blood urea nitrogen, creatinine, triglyceride, total cholesterol, HDL-cholesterol and fasting blood glucose(FBG) were obtained from subjects. In general characteristics, smoking, drinking, exercise, and hypertension status were not significantly different between the two groups. Food habits and the means of daily energy and nutrients were not significantly different between the two groups. An analysis of the percentage of RDA(Recommended Dietary Allowances of Korea, 2000) consumed by patients showed that but for ascorbic acid and phosphorus, all nutrients were below the RDA. And intakes of vitamin $B_1$(P<0.001), vitamin $B_2$(P<0.01), niacin(P<0.001) of the obese group were significantly lower than that of the non-obese group. Blood urea nitrogen, creatinine, triglyceride, total cholesterol, HDL-cholesterol and fasting blood glucose were in the normal range and there was not a significant difference in the two groups. Therefore, more effective nutrition education programs about exercise, smoking, caloric intake, vitamins and minerals are required for hypertensive patients commuting to Local Health Center.

  • PDF

A Method for Critical Heat Flux Prediction in Vertical Round Tubes with Axially Non-uniform Heat Flux Profile

  • Shim, Jae-Woo
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.13-21
    • /
    • 2008
  • In this study a method to predict CHF(Critical heat flux) in vertical round tubes with axially non-uniform cosine heat flux distribution for water was examined. For this purpose a local condition hypothesis based CHF prediction correlation for uniform heat flux in vertical round tubes for water was developed from 9,366 CHF data points. The local correlation consisted of 4 local condition variables: the system pressure(P), tube diameter(D), mass flux of water(G), and 'true mass quality' of vapor($X_t$). The CHF data points used were collected from 13 different published sources having the following operation ranges: 1.01 ${\leq}$ P (pressure) ${\leq}$ 206.79 bar, 9.92${\leq}$ G (mass flux) ${\leq}$ 18,619.39 $kg/m^2s$, 0.00102 ${\leq}$ D(diameter) ${\leq}$ 0.04468 m, 0.0254${\leq}$ L (length) ${\leq}$ 4.966 m, 0.11 ${\leq}$ qc (CHF) ${\leq}$ 21.41 $MVW/m^2$, and -0.87 ${\leq}X_c$ (exit qualities) ${\leq}$ 1.58. The result of this work showed that a uniform CHF correlation can be easily extended to predict CHF in axially non-uniform heat flux heater. In addition, the location of the CHF in axially non-uniform tube can also be determined. The local uniform correlation predicted CHF in tubes with axially cosine heat flux profile within the root mean square error of 12.42% and average error of 1.06% for 297 CHF data points collected from 5 different published sources.

Estimation of Source Apportionment for Semi-Continuous PM2.5 and Identification of Location for Local Point Sources at the St. Louis Supersite, USA (미국 St. Louis Supersite에서의 준 실시간 PM2.5에 대한 기여도 추정 및 지역 규모 오염원의 위치 파악)

  • Hwang, In-Jo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.2
    • /
    • pp.154-166
    • /
    • 2009
  • In this study, 1-hour integrated $PM_{2.5}$ mass and chemical composition concentrations were monitored at the St. Louis-Midwest Supersite in Illinois. Time-resolved samples were collected one week in each of June 2001 (22 June to 28 June), November 2001 (7 November to 13 November), and March 2002 (19 March to 25 March). A total of 427 samples were collected by CAMM (continuous ambient mass monitor) and 15 compounds were analyzed by AAS, PILS (particle-into-liquid sampler), and TOT (thermal optical transmittance) method. PMF was applied to identify the sources and apportion the $PM_{2.5}$ mass to each source for highly time resolved data. In addition, the nonparametric regression (NPR) was applied to identify the predominant directions of local sources relative to wind direction. Also, this study performed compare the NPR analysis and location of actual local point sources at the St. Louis area. The PMF modeling identified nine sources and the average mass was apportioned to gasoline vehicle, road dust, zinc smelter, copper production, secondary sulfate, diesel emission, secondary nitrate, iron+steel, and lead smelter, respectively. These results suggested that this study results will be help for $PM_{2.5}$ source apportionment studies at similar metropolitan area, establish $PM_{2.5}$ standard, and establish effective emissions reduction strategies in Korea.

Cooling characteristics of the multichip module using paraffin slurry (파라핀 슬러리를 사용한 다칩모듈의 냉각특성)

  • Jo, Geum-Nam;Choe, Min-Gu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.6
    • /
    • pp.888-898
    • /
    • 1998
  • The present study investigated the effects of the experimental parameters on the cooling characteristics of the multichip module cooled by the indirect liquid cooling method using water and paraffin slurry. The experimental parameters are mass fraction of 2.5 ~ 7.5% for paraffin slurry, heat flux of 10 ~ 40 W/cm$^{2}$ for the simulated VLSI chips and Reynolds numbers of 5,300 ~ 15,900. The apparatus consisted of test section, paraffin slurry maker, pump, constant temperature baths, flowmeter, etc. The test section made of in-line, four-row array of 12 heat sources for simulating 4 * 3 multichip module which was flush mounted on the top wall of a horizontal rectangular channel with the aspect ratio of 0.2. The inlet temperature was 20 deg. C for all experiments. The size of paraffin slurry was constant as 10 ~ 40 .mu.m befor and after the experiment. The chip surface temperatures for paraffin slurry with the mass fraction of 7.5% showed lower by 16 deg. C than those for water when the heat flux is 40 W/cm$^{2}$. The local heat transfer coefficients for the paraffin slurry with the mass fraction of 7.5% were larger by 17 ~ 25% than those for water at the first and the fourth row. The local heat transfer coefficients reached to a row-number-independent, thermally fully developed value approximately after the third row. The local Nusselt numbers at the fourth row for paraffin slurry with the mass fraction of 7.5% were larger by 23 ~ 29% than those for water.

On the Global and Local Environmental Dependence of Type Ia Supernova Luminosity from the Analysis of SALT2 and MLCS2k2 Light-Curve Fitters

  • Kim, Young-Lo;Lee, Young-Wook
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.40.3-40.3
    • /
    • 2019
  • There is growing evidence for the dependence of Type Ia supernova (SN Ia) luminosities on the environments. The origin of this correlation, however, is under debate. In order to explore the physical origin of the trend in detail, we analyze SN Ia light-curves by combining a sample of 1231 SNe Ia over a wide redshift range (0.01 < z < 1.37) in various SN surveys and employing two independent light-curve fitters of SALT2 and MLCS2k2. Although SALT2 is the most widely used fitter in the SN community, MLCS2k2 has a novelty in the context of an investigation of the luminosity evolution of SNe Ia. For this reason we use both fitters and analyze them separately. We also determine a stellar mass and a star formation rate (SFR) for a sample of ~600 host galaxies. In addition, because recent low-redshift studies suggest that this dependence manifests itself most strongly when using the local SFR at the SN location, we introduce a new method to infer the local environments by restricting the SN Ia sample in globally star-forming host galaxies to a low-mass host galaxy subset (${\leq}10^{10}M_{\odot}$). We find that SNe Ia in low-mass and star-forming host galaxies are fainter than those in high-mass and passive hosts, after light-curve corrections. Especially, for the first time in host studies, we show that SNe Ia in locally star-forming environments are $0.081{\pm}0.018$ mag fainter ($4.5{\sigma}$) than those in locally passive environments from the sample including SNe at the high-redshift range. Considering the significant difference in the mean stellar population age between these environments, the result would suggest that the origin of the environmental dependence is the luminosity evolution of SNe Ia.

  • PDF

ON THE PHYSICAL BASIS OF THE TULLY-FISHER RELATION

  • RHEE MYUNG-HYUN
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.15-39
    • /
    • 2004
  • We analyse the results of mass models derived from the HI rotation! curves of spiral galaxies and find that the slope of the luminous mass-circular velocity relation is close to 4. The luminous mass-circular velocity relation with a slope of about 4 can be explained by an anti-correlation between the mass surface density of luminous matter and the mass ratio of the dark and luminous components. We also argue that the conspiracy between luminous and dark matter exists in a local sense (producing a flat or smooth rotation curve) and in a global sense (affecting the mass ratio of the dark and luminous matter), maintaining the luminous mass-circular velocity relation with a slope of about 4. We therefore propose that the physical basis of the Tully-Fisher relation lies in the luminous mass-circular velocity relation. While the slope of the luminous mass-circular velocity relation is fairly well defined regardless of the dark matter contribution, the zero-point of the relation is still to be determined. The determination of the slope of the Tully-Fisher relation needs one more step: the mean trend of the luminosity-luminous mass relation determines the overall shape (slope) of the Tully-Fisher relation. The key parameter needed to determine the zero-point of the luminous mass-circular velocity relation and the slope of the Tully-Fisher relation obviously is the luminous mass-to-light ratio.

A study on the correlation between the result of electrical resistivity survey and the rock mass classification values determined by the tunnel face mapping (전기비저항탐사결과와 터널막장 암반분류의 상관성 검토)

  • 최재화;조철현;류동우;김학규;서백수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.265-272
    • /
    • 2003
  • In this study, the rock mass classification results from the face mapping and the resistivity inversion data are compared and analyzed for the reliability investigation of the determination of the rock support type based on the surface electrical survey. To get the quantitative correlation, rock engineering indices such as RCR(rock condition rating), N(Rock mass number), Q-system based on RMR(rock mass rating) are calculated. Kriging method as a post processing technique for global optimization is used to improve its resolution. The result of correlation analysis shows that the geological condition estimated from 2D electrical resistivity survey is coincident globally with the trend of rock type except for a few local areas. The correlation between the results of 3D electrical resistivity survey and the rock mass classification turns out to be very high. It can be concluded that 3D electrical resistivity survey is powerful to set up the reliable rock support type.

  • PDF

Advances in Ion Mobility Spectrometry-Mass Spectrometry (IMS-MS)-Based Techniques for Elucidating Higher-Order Protein Structures

  • Seo, Jongcheol
    • Mass Spectrometry Letters
    • /
    • v.11 no.4
    • /
    • pp.65-70
    • /
    • 2020
  • Despite its great success in the field of proteomics, mass spectrometry has limited use for determining structural details of peptides, proteins, and their assemblies. Emerging ion mobility spectrometry-mass spectrometry has enabled us to explore the conformational space of protein ions in the gas phase, and further combinations with the gas-phase ion spectroscopy and the collision-induced unfolding have extended its abilities to elucidating the secondary structure and local details of conformational transitions. This review will provide a brief introduction to the combined approaches of IMS-MS with gas-phase ion infrared spectroscopy or collision-induced unfolding and their most recent results that successfully revealed higher-order structural details.

Local Heat Transfer Coefficients for Reflux Condensation Experiment in a Vertical Tube in the Presence of Noncondensible Gas

  • Moon, Young-Min;No, Hee-Cheon;Bang, Young-Seok
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1999.05a
    • /
    • pp.104-104
    • /
    • 1999
  • The local heat transfer coefficient is experimentally investigated for the reflux condensation in a countercurrent flow between the steam-air mixture and the condensate. A single vertical tube has a geometry which is a length of 2.4m, inner diameter of 16.56mm and outer diameter of 19.05mm and is made of stainless steel. Air is used as a noncondensible gas. The secondary side is installed in the form of coolant block around vertical tube and the heat by primary condensation is transferred to the coolant water. The local temperatures are measured at 15 locations in the vertical direction and each location has 3 measurement points in the radial direction, which are installed at the tube center, at the outer wall and at the coolant side. In three different pressures, the 27 sets of data are obtained in the range of inlet steam flow rate 1.348 -3.282kg/hr, of inlet air mass fraction 11.8 -55.0%. The local heat transfer coefficient increases as the increase of inlet steam flow rate and decreases as the decrease of inlet air mass fraction. As an increase of the system pressure, the active condensing region is contracted and the heat transfer capability in this region is magnified. The empirical correlation is developed represented with the 165 sets of local heat transfer data. As a result, the Jacob number and film Reynolds number are dominant parameters to govern the local heat transfer coefficient. The rms error is 17. 7% between the results by the experiment and by the correlation.

  • PDF