• Title/Summary/Keyword: load-curvature relation

Search Result 22, Processing Time 0.023 seconds

New approach for Ductility analysis of partially prestressed concrete girders

  • Radnic, Jure;Markic, Radoslav;Grgic, Nikola;Cubela, Dragan
    • Structural Engineering and Mechanics
    • /
    • v.70 no.3
    • /
    • pp.257-267
    • /
    • 2019
  • Expressions for the calculation of ductility index for concrete girders with different ratios of prestressed and classical reinforcement were proposed using load-displacement, load-strain and load-curvature relation. The results of previous experimental static tests of several large-scale concrete girders with different ratio of prestressed and classical reinforcement are briefly presented. Using the proposed expressions, various ductility index of tested girders were calculated and discussed. It was concluded that the ductility of girders decreases approximately linearly by increasing the degree of prestressing. The study presents an expression for the calculation of the average ductility index of classical and prestressed reinforced concrete girders, which are similar to the analysed experimental test girders.

Strengthening Effects of Epoxy Mortar Systems on Reinforced Concrete Beams by Flexural Tensile Strength (변성에폭시 모르터 휨인장강도가 단면증대 보에 미치는 영향)

  • 류현희;신영수;정혜교
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.787-790
    • /
    • 2000
  • This paper presents an experimental study on flexural behavior of structural member enlarged with epoxy mortar system. The main test variable is flexural tensile strength. A series of 4 test beams was tested to shoe the corresponding effect of each variables on maximum load capacity, load-deflection and moment-curvature relationship, interface behavior and failure mode. The results show that the flexural tensile strength of retrofitted materials have no relation load-deflection, but to load-strain, and failure mode.

  • PDF

Ductility of Circular Hollow Columns with Internal Steel Tube (강관 코아 합성 중공 기둥의 연성 거동 연구)

  • 강영종;한승룡;박남회
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.183-188
    • /
    • 2002
  • In locations where the cost or concrete is relatively high, or in situations where the weight or concrete members is to be kept to a minimum, it may be economical to use hollow reinforced concrete vertical members. Hollow reinforced concrete columns with low axial load, moderate longitudinal steel percentage, and a reasonably thick wall were found to perform in a ductile manner at the flexural strength, similar to solid columns. However, hollow reinforced concrete columns with high axial load, high longitudinal steel percentage, and a thin wall were found to behave in a brittle manner at the flexural strength, since the neutral axis is forced to occur away from the inside face of the tube towards the section centroid and, as a result, crushing of concrete occurs near the unconfined inside face of the section. If, however, a steel tube is placed near the inside face of a circular hollow column, the column can be expected not to fail in a brittle manner by disintegration of the concrete in the compression zone. Design recommendation and example by moment-curvature analysis program for curvature ductility are presented. Theoretical moment-curvature analysis for reinforced concrete columns, indicating the available flexural strength and ductility, can be conducted providing the stress-strain relation for the concrete and steel are known. In this paper, a unified stress-stain model for confined concrete by Mander is developed for members with circular sections.

  • PDF

Evaluation for Confined Effects by the Sectional Properties of Concrete Filled Steel Tube Columns (콘크리트 충전형 압축부재의 단면특성에 따른 구속효과 평가)

  • Park, Kuk-Dong;Hwang, Won-Sup;Kim, Hee-Ju;Jun, Myung-Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.4
    • /
    • pp.365-375
    • /
    • 2010
  • Concrete-filled steel tube columns are expected to have confined effects of the steel on the concrete and reinforced local buckling effects of the concrete. After comparing the results of existing studies with the experimental results from this study, the stress-strain relations were modified by evaluating the load-displacement with consideration of the confined effects. The effects of the parameters on the load-displacement and moment-curvature relationship according to the sectional and material properties were analyzed.

Free Vibration of Compressed Laminated Composite Beam-Columns with Multiple Delaminations (압축하중을 받는 다층간분리 적층 복합 보-기둥의 자유진동)

  • 이성희;박대효;백재욱;한병기
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.10a
    • /
    • pp.501-508
    • /
    • 2001
  • Free vibration analysis of multi-delaminated composite beam-columns subjected to axial compression load is performed in the present study. In order to investigate the effects of multi-delaminations on the natural frequency and elastic buckling load of multi-delaminated beam-columns, the general kinematic continuity conditions are derived from the assumption of constant slope and curvature at the multi-delamination tip. Characteristic equation of multi-delaminated beam-column is obtained by dividing the global multi-delaminated beam-columns into segments and by imposing recurrence relation from the continuity conditions on each sub-beam-column. The natural frequency and elastic buckling load of multi-delaminated beam-columns according to the incremental load of axial compression, which is limited to the maximum elastic buckling load of sound laminated beam-column, are obtained. It is found that the sizes, locations and numbers of multi-delaminations have significant effect on natural frequency and elastic buckling load, especially the latter ones.

  • PDF

Strength and Moment-Curvature Relationship of HCFT Columns under Eccentric Load (편심압축이 작용하는 HCFT기둥에 대한 내력특성과 모멘트-곡률의 곤계)

  • 이승조;박정민;김화중
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.864-873
    • /
    • 2002
  • Recently, CFT Column has reported a lot of study result, because a CFT column has certain superior structural properties as well as good productivity, execution efficiency, and improved rigidity over existing column. However, CFT column still has problems clearing the capacity evaluation between its steel tube member and high-strength concrete materials. Also, high-strength concrete filled steel square tube column(HCFT) examined numerical value explanatorily about transformation performance(M-ø) of when short-column receives equal flexure-moment from axial stress on research for concrete. hnd, with basis assumption, executed development of analysis program of moment-curvature relation for analytic analysis of transformation performance of HCFT section that get by an experiment. This study investigated to properties of structural(capacity, curvature), through a series of experiments for HCFT with key parameters, such as strength of concrete(600kgf/$\textrm{cm}^2$), D/t ratio, slenderness ratio(λ) and concrete kinds under eccentric load. And, I executed comparative analysis with AISC-LRFD, AIJ and Takanori Sato etc. and experiment result that is capacity design formula.

Nonlinear Moment-Curvature Relations and Numerical Structural Analysis of High-Strength PSC Flexural Members (고강도 PSC 휨부재의 비선형 모멘트-곡률 관계와 전산구조해석)

  • 연정흠;이제일
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.1
    • /
    • pp.95-104
    • /
    • 2002
  • A methods to calculate non-linear moment-curvature relations of high-strength PSC flexural members for numerical analysis has been proposed. The moment-curvature relations were calculated with assumptions of design codes and by the layer method. The results of the proposed procedures for moment-curvature relations and numerical analysis were compared with those of pre-existing tests. The absorption energy rate of the design codes was about 30% larger than that of the layer method. The ultimate load and the external work of the layer method were 90% and 85% of those of tests, respectively The ultimate load of the strength design method was 97% of that of tests, but the external work was over-estimated with 122%. The ultimate load and external work by the proposed equation of the CEB-FIP Model Code were 113% and 173% of those of tests, respectively. It show that the use of ultimate strain of 0.0035 should be over-estimated for high-strength concrete. The procedure of non-linear numerical analysis of this research could be stably simulated the behavior of concrete flexural members until the ultimate state, and calculate results of the load-deflection relation and cracking pattern were very similar with those of tests.

The Structural Behavior of Cold-Formed Steel Composite Beams (냉간성형강재를 이용한 합성보의 구조적인 거동)

  • 양구록;송준엽;권영봉
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.10a
    • /
    • pp.206-213
    • /
    • 1999
  • The behavior of composite beams, which are composed of cold-formed steel sheeting and normal strength concrete, have been studied. An analytical method has been developed to trace the nonlinear behavior of composite beams. The nonlinear material properties of steel sheeting, reinforcing steel bar and concrete have been included in the analysis. The nonlinear moment-curvature relation of the composite beam has been described using a cross section analysis method and a simple power model, separately. The load-deflection behavior of the beams has been simulated by step-by-step numerical integration method and is compared with test results.

  • PDF

An Analytical Study on the Structural Behavior of Composite Beams (합성보의 거동에 관한 해석적 연구)

  • 황영서;양구록;송준엽;권영봉
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.10a
    • /
    • pp.175-182
    • /
    • 1998
  • An analytical study to trace the nonlinear structural behavior of composite beams is undertaken to include the nonlinear material properties of steel sheeting, reinforcing steel bar and concrete. To trace Moment-curvature relations, sectioning analysis method and two simple formulas are developed. A simple power model which has been originally used to expect the flexural capacity of the beam to column connections is proposed and the second formula is composed of two experimental functions to express the Moment-curvature relation in the elastic and plastic range separately. The load-deflection behavior of the beams has been simulated by the step-by-step numerical integration method and is compared with the test results available.

  • PDF

Stability Evaluation & Determination of Critical Buckling Load for Non-Linear Elastic Composite Column (비선형 탄성 복합재료 기둥의 임계 좌굴하중 계산 및 안정성 평가)

  • 주기호;정재호;강태진
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.04a
    • /
    • pp.215-219
    • /
    • 2003
  • Buckling and post-buckling Analysis of Ludwick type and modified Ludwick type elastic materials was carried out. Because the constitutive equation, or stress-strain relationship is different from that of linear elastic one, a new governing equation was derived and solved by $4^{th}$ order Runge-Kutta method. Considered as a special case of combined loading, the buckling under both point and distributed load was selected and researched. The final solution takes distinguished behavior whether the constitutive relation is chosen to be modified or non-modified Ludwick type as well as linear or non-linear. We also derived strain energy function for non-linear elastic constitutive relationship. By doing so, we calculated the criterion function which estimates the stability of the equilibrium solutions and determines critical buckling load for non-linear cases. We applied this theory to the constitutive relationship of fabric, which also is the non-linear equation between the applied moment and curvature. This results has both technical and mathematical significance.

  • PDF