• Title/Summary/Keyword: load-balanced

Search Result 259, Processing Time 0.034 seconds

Maneuverability of a DWT 8,000-ton oil/chemical tanker by real sea trials - A comparison between the semi-balanced rudder and the flap rudder - (실선시험에 의한 DWT 8,000톤 선박의 조종성능 - Semi-balanced rudder and flap rudder -)

  • An, Young-Su;Lee, Hyeong-Geun;Park, Byung-Soo;Jang, Choong-Sik
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.2
    • /
    • pp.257-264
    • /
    • 2015
  • This study is intended to provide navigator with specific information necessary to assist the avoidance of collision and the operation of ships to evaluate the maneuverability of dead weight tonnage 8,000 tons Oil/Chemical tanker. The actual maneuvering characteristics of ship can be adequately judged from the results of typical ship trials. Author carried out sea trials based full scale for turning test, Z" maneuvering test, man overboard rescue maneuver test, inertia stopping test. Consequently, $2^{st}$ Overshoot yaw angle of the semi balanced rudder and flap rudder in ${\pm}20^{\circ}$ zig-zag test showed $22.2^{\circ}$ and $18.0^{\circ}$, respectively. The maneuverability of the vessel was good in the flap rudder. The man overboard rescue maneuver maneuverability test was most favorable in the flap rudder and the full load condition. The results from tests could be compared directly with the standards of maneuverability of IMO and consequently the maneuvering qualities of the ship is full satisfied with its.

Control and Operating Characteristics of Three-Phase Matrix Converter with Unity Power Factor by Direct Duty-Ratio Modulation Method (단위 역률을 갖는 직접 시비율 변조방식 3상 매트릭스 컨버터의 제어 및 동작 특성)

  • Li, Yulong;Choi, Nam-Sup;Han, Byung-Moon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.142-149
    • /
    • 2009
  • This paper investigates operating characteristics of three-phase matrix converter with unity input power factor by direct duty-ratio pulse-width modulation in the case of balanced and unbalanced load. It can be found from the system analysis that (1) The control algorithm for unity power factor is not related to the variables of load sides but the input voltages, (2) With the balanced three-phase load except for the pure reactive load, the unity input power factor can be achieved, (3) In the case of the unbalanced linear load, the equivalent input characteristics of the matrix converter can be seen like the nonlinear resister, (4) When the input frequency and the output frequency have the specific relationship, each input phases have the same sharing of the average power. The feasibility and validity of the analysis were verified by simulation and experimental results.

Hierarchical Inter-domain Load Balanced QoS Routing (계층적 도메인간 부하분산 QoS 라우팅)

  • Hong, Jong-Joon;Kim, Seung-Hoon;Lee, Kyoon-Ha
    • The KIPS Transactions:PartC
    • /
    • v.9C no.5
    • /
    • pp.671-678
    • /
    • 2002
  • In this paper, we propose hierarchical inter-domain load balanced QoS routing in a large scale of network. And a scheme of calculating resources'costs for precomputation schemes in hierarchical routing is proposed, and a scheme for selecting a path among multiple precomputed paths is proposed. We also propose a QoS routing scheme for transit and intra traffic in a large scale of domain-based network. For a domain in the network, the routing scheme first precomputes K multiple paths between all pairs of ingress and egress border routers while considering balancing of the expected load then selects paths with the probability of path selection. The routing scheme combines inter and intra domain routings seamlessly and uses the same cost calculation scheme. And these schemes make possible both global network resources' utilization and also load balancing.

An Ad-hoc Routing Protocol for Load Balancing (부하균등을 고려한 Ad-hoc 라우팅 프로토콜)

  • 안상현;임유진;김경춘
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.04a
    • /
    • pp.118-120
    • /
    • 2002
  • Ad-hoc 네트워크에서의 라우팅 프로토콜은 현재 사용중인 경로가 혼잡하다 하더라도 네트워크 토폴로지가 변하기 이전에는 새로운 경로를 설정하지 못하므로, 노드의 이동성이 낮은 환경에서는 트래픽의 집중 현상이 심화된다. 이동 기기들은 그 성능과 배터리에 한계가 있기 때문에 일부 소수 노드들에게 트래픽 집중되는 경우 다른 노드들에 대한 데이터 중계 서비스를 제공하는데 자신의 자원 대부분을 낭비하도록 강요받게 된다. 따라서 본 논문에서 혼잡 상태의 노드는 더 이상의 데이터 패킷 중계를 포기하고 이를 해당 소스에게 알림으로써 소스가 새로운 우회경로를 설정하도록 하여 트래픽의 집중 현상을 완화시키는 새로운 프로토콜인 SLAP(Simple Load-balanced Ad-hoc routing Protocol)을 제안한다.

  • PDF

Nonlinear Control of Three-phase Split-Capacitor Inverters under Unbalanced and Nonlinear Load Conditions

  • Nguyen, Qui Tu Vo;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.52-53
    • /
    • 2012
  • This paper presents a new control scheme for a three-phase split DC-link capacitor inverter as an AC power supplies. The proposed control method can maintain the balanced sinusoidal output voltage under unbalanced and nonlinear load conditions. The validity of the control method has been verified by simulation results.

  • PDF

Monolithic X-band Mixer (모노리식 X-band 혼합기)

  • Jun, Yong-Il;Park, Hyung-Moo;Ma, Dong-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.426-429
    • /
    • 1988
  • A simple design method of a single balanced MMIC mixer is described. It uses small signal S11 and capacitive load for the input matching circuit and the output loading circuit, respectively. It is found that the conversion gain of the FET mixer is independent of FET gate width. The fabricated mixer has 2.5 dB conversion gain at 9 GHz with 50 ohm IF load and 2 dBm local oscillator power.

  • PDF

A Novel Three-Level ZVS PWM Inverter Topology for High-Voltage DC/DC Conversion Systems with Balanced Voltage Sharing and Wider Load Range (차단전압 균형과 넓은 부하범위를 갖는 새로운 3-레벨 ZVS PWM DC-DC 컨버터)

  • 송인호;유상봉;서범석;현동석
    • Proceedings of the KIPE Conference
    • /
    • 1996.06a
    • /
    • pp.71-75
    • /
    • 1996
  • As the Three-level ZVS PWM DC-DC converter operates likewise full-bridge ZVS PWM DC-DC converter and the blocking voltage of each switching device is a half of the DC-link voltage, it is suitable for the high imput voltage applications. However, it has some problems as follows; The blocking voltage of each devices is unbalanced and it causes the power losses of the inner switching devices to be increased. Also, it has narrow load range so that the switching losses and the efficiency are reduced as it goes to the light load. This paper presents an nove Three-level ZVS PWM DC-DC converter, which can reduce the overvoltage of the outer switches, eliminate the unbalance of the voltage sharing between the switches at turn-off due to the stray inductances, and operate from no load to full load. The characteristics and the performances of the proposed Three-level ZVS PWM DC-DC converter are verified by simulation and experimental results

  • PDF

Analysis on the Characteristics of Voltage Unbalance Factor by Load Variations (부하 변동에 의한 전압불평형율의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.1
    • /
    • pp.47-53
    • /
    • 2005
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating voltage unbalance. Voltage unbalance factor is mainly affected by load system rather than stable power system. Unbalanced voltage will draw a highly unbalanced current. As a result, the three-phase currents may differ considerably, thus resulting in an increased temperature rise in the machine. This paper presents a scheme on the characteristics of voltage and current unbalance factor under the load variation at the three phase 4-wire system. Load unbalance factor is measured by the power quality measurement apparatus and compared by the current unbalance factor. Two methods are indicated similar results. The voltage unbalance factor of the three-phase 4-wire system is approved by the field measurement. Each phase has an impedance each other by the unbalanced operation pattern and give rise to voltage unbalance.

THE DESIGN OF AN EFFICIENT LOAD BALANCING ALGORITHM EMPLOYING BLOCK DESIGN

  • Chung, Il-Yong;Bae, Yong-Eun
    • Journal of applied mathematics & informatics
    • /
    • v.14 no.1_2
    • /
    • pp.343-351
    • /
    • 2004
  • In order to maintain load balancing in a distributed system, we should obtain workload information from all the nodes on network. This processing requires $O(v^2)$ communication overhead, where v is the number of nodes. In this paper, we present a new synchronous dynamic distributed load balancing algorithm on a (v, k + 1, 1)-configured network applying a symmetric balanced incomplete block design, where $v\;=\;k^2$\;+\;k\;+\;1$. Our algorithm needs only $O(\sqrt[v]{v})$ communication overhead and each node receives workload information from all the nodes without redundancy. Therefore, load balancing is maintained since every link has the same amount of traffic for transferring workload information.

A Study of Reconfiguration for Load Balancing in Distribution Power System (배전계통 부하 균등화를 위한 재구성에 관한 연구)

  • Seo, Gyu-Seok;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1360-1366
    • /
    • 2007
  • In this paper, the load balancing which is one of the distribution power system's operation purposes was studied. Reconfiguration of Distribution power system presents that the configuration is changed by changing the switch on/off status which exists in the system according to the mentioned purpose. Through this method, the load of distribution power system is shown to be balanced. As a characteristic of complicated distribution power system, system is designed by being applied by OOP(Object Oriented Programming) method which connected more flexibly than existing Procedural Programming method, and the process of calculating the distflow and the loss of configurated system is shown. In addition, this paper suggests more efficient method compared by the results of reconfiguration on the purpose of the loss minimization and by the result of distribution power system reconfiguration on the purpose of load balancing. Moreover, it searches for the method to approach the global optimal solution more quickly.