• Title/Summary/Keyword: load transient

Search Result 780, Processing Time 0.022 seconds

Power System Stability Analysis Considering Dynamic Loads (동적 부하를 고려한 전력계통의 On-Line 안정도 해석)

  • Seo, Gyu-Seok;Park, Ji-Ho;Kwon, Ki-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.4146-4151
    • /
    • 2012
  • In this paper, we have simulated the transient stability of power system with dynamic loads. Dynamic load characteristics have an important influence on power system stability. In study of power system stability, motors form a major portion of the system loads. Induction motors and synchronous motors in particular form the workhorse of the electric power industry. Therefore modelling of motors is important in system stability. We investigate the effect of motors loads of Kwang Yang network with three phase fault.

Redundant Operation of a Parallel AC to DC Converter via a Serial Communication Bus

  • Kanthaphayao, Yutthana;Kamnarn, Uthen;Chunkag, Viboon
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.533-541
    • /
    • 2011
  • The redundant operation of a parallel AC to DC converter via a serial communication bus is presented. The proposed system consists of three isolated CUK power factor correction modules. The controller for each converter is a dsPIC30F6010 microcontroller while a RS485 communication bus and the clock signal are used for synchronizing the data communication. The control strategy of the redundant operation relies on the communication of information among each of the modules, which communicate via a RS485 serial bus. This information is received from the communication checks of the converter module connected to the system to share the load current. Performance evaluations were conducted through experimentation on a three-module parallel-connected prototype, with a 578W load and a -48V dc output voltage. The proposed system has achieved the following: the current sharing is quite good, both the transient response and the steady state. The converter modules can perform the current sharing immediately, when a fault is found in another converter module. In addition, the transient response occurs in the system, and the output voltages are at their minimum overshoot and undershoot. Finally, the proposed system has a relatively simple implementation for the redundant operation.

The Improvement of the Performance of Solar Cooling and Heating Systems (II) - The Characteristics of an Absorption Refrigeration Powered by Solar Systems - (태양열에 의한 냉방 및 난방시스템의 성능향상(II) - 태양열을 이용한 흡수식 냉동기의 성능 -)

  • Park, M.S.;Kim, M.G.;Kim, H.K.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.1
    • /
    • pp.46-54
    • /
    • 1989
  • The purpose of this study is to obtain the dynamic characteristics of an absorption refrigerator powered by solar energy by experiments. Since the absorption refrigerator power by solar energy should have the characteristics which is suitable for the intermittence and rarity of solar energy, not only the characteristics of the steady state operations but also the partial load and the transient operations should be considered. The minimum available temperature of the storage tank should be known, and the absorption refrigerator can be suitably selected for air-conditioning systems. In this study, the experimental data of the transient state for on-off and warming-up operations has been obtained. Also the experiments are performed which test the minimum available temperature of the storage tank. The results show that it takes 1 hour to get to the steady state of the absorption refrigerator, and the minimum available temperature of the storage tank is about $68^{\circ}C$, and show that in the partial load operations the performance of the absorption refrigerator is improved by applying the modified control method to on-off operations.

  • PDF

A Current-Fed Parallel Resonant Push-Pull Inverter with a New Cascaded Coil Flux Control for Induction Heating Applications

  • Namadmalan, Alireza;Moghani, Javad Shokrollahi;Milimonfare, Jafar
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.632-638
    • /
    • 2011
  • This paper presents a cascaded coil flux control based on a Current Source Parallel Resonant Push-Pull Inverter (CSPRPI) for Induction Heating (IH) applications. The most important problems associated with current source parallel resonant inverters are start-up problems and the variable response of IH systems under load variations. This paper proposes a simple cascaded control method to increase an IH system's robustness to load variations. The proposed IH has been analyzed in both the steady state and the transient state. Based on this method, the resonant frequency is tracked using Phase Locked Loop (PLL) circuits using a Multiplier Phase Detector (MPD) to achieve ZVS under the transient condition. A laboratory prototype was built with an operating frequency of 57-59 kHz and a rated power of 300 W. Simulation and experimental results verify the validity of the proposed power control method and the PLL dynamics.

Using Closed Loop Flux Estimator The Sensorless Vector Control Of Induction Motor (폐루프 자속추정기를 이용한 철도차량의 유도 전동기 센서리스 벡터제어)

  • Jang, Jin-Hyog;Hwang, Lak-Hun;Cho, Moon-Taek
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.6
    • /
    • pp.1092-1099
    • /
    • 2006
  • Displayed system equationally using accurate dynamic modeling of whole system including induction motor and load to analyze induction motor to normal condiction's action characteristic as well as transient characteristic using power converter device such as inverter in this paper. Also, presume adhesive power calculation through speed sensorless vector control and load torque disturbance observer for maximum tractive force control. Confirmed proposed algorithm through simulation and an experiment using railroad experiment equipment to embody control algorithm of such system. With relation of adhesive power about the wage speed by speed addition and subtraction of railway vehicle, embodied all sorts item by experiment equipment.

  • PDF

A Voltage-Lift DC-DC Converter with Large Conversion Ratio

  • Kim, Ho-Yeon;Moon, Eun-A;Lee, Yong-Mi;Choi, Youn-ok
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.1054-1060
    • /
    • 2019
  • A extension of the high boost voltage-lift DC-DC converter with large conversion ratio has been proposed in this paper. The proposed extension is combined the switched-inductor cell (SL-cell) and modular voltage cell (MV-cell). The proposed structure can achieve the large voltage conversion without high duty-cycle and the low voltage of the components. Moreover, the PID controller for novel SL-MV voltage-lift DC-DC converter also introduces. This technique a good-performance output voltage can kept constant with an good transient performance when the output load is suddenly changed. In order to prove the theoretical analysis, the experimental setup has been built for the DC load of $150[{\Omega}]$ and $300[{\Omega}]$. In addition, the transient of output voltage has been tested to determine the controller. Experimental results validate the effectiveness of the theoretical analysis proving the satisfactory converter performance.

An Experimental Study of The J-T Cryocooler with Mixed Refrigerant (혼합 냉매를 이용한 극저온 J-T 냉동기 관한 실험적 연구)

  • 이경수;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.64-68
    • /
    • 2001
  • An experimental study on the Joule-Thomson cryocooler with the mixed refrigerant (MR) is described in this paper, J-T refrigeration experiment was performed with a single stage regular air-conditioning compressor The mixed refrigerant in the experiment was composed of 75% mol fraction of $N_2$. 30% moi fraction of CH$_4$. 30% moi fraction of $C_2$H$_{6}$. 10% mot fraction of $C_3$H$_{8}$ and 15% mot fraction of iso-C$_4$H$_{10}$. Oil mist in the MR stream could be eliminated completely by the glass microfiber filter. Since a single stage compressor that had been designed thor R22 is not appropriate for high Pressure ratio of the mixed refrigerant especially during the transient period. two modifications were incorporated to regular J-T refrigeration cycle. First. a Portion of the MR was by-passed at the inlet of the heat exchanger and transferred directly to 7he suction of the compressor in the modified system. Second, a buffer volume was Prepared to change the mass flow rate of refrigerant. The pressure ratio in J-T expansion device was relieved at the beginning of the operation due to the by-Pass scheme. but it gradually decreased during the transient Process as some of the MR component condensed at low temperature. The buffer volume at the suction side was used to increase the MR gas density in the system after the transient cool-down period. Form the experiment with the modified system, the refrigerator could reach the lowest temperature of -152$^{\circ}C$ without cooling load. and about -15$0^{\circ}C$ with 5 W of cooling load . . . .

  • PDF

A Study on Power loading Experiment & Performance Analysis for Dynamic Transient Effect of a Turbo-shaft Engine with Free Power Turbine (분리 축 가스 터빈 엔진의 동역학적 천이 효과를 고려한 성능 해석 및 부하 인가 시험에 관한 연구)

  • Kim Gyoung-du;Yang Soo-seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.3
    • /
    • pp.17-26
    • /
    • 2004
  • In this paper, power transmission systems converts the shaft power of a Turbo-shaft Engine with Free Power Turbine into the generator power and be composed of a method being supplied in the thrust motor driving a propellers. Being used this, Gas turbine engine works to flat rating about 110 kw (147 shp) that the thrust motor be extremely supplied from the engine of 317shp. In this test equipment, the engine is installed with the flywheel being able to the damping function when happen to the varying load between gas turbine engine output-shaft and generator. Then if the flywheel of inertial moment be not considered, the generator and motor not get the required power from the engine for raising the load. Also it is certified that the engine works the abnormal operation. Hence the flywheel of inertial moment is determined the required range to do the performance analysis with the dynamic transient from the given and tested engine data. This system is able to get the required power after a mounting test with the redesigned flywheel.

Improvement of Transient Performance of Synchronous Generator using Feedforward Controller (피드포워드 제어기를 사용한 동기발전기의 과도특성 개선)

  • An, Young-Joo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.2
    • /
    • pp.57-62
    • /
    • 2018
  • A brush-less type synchronous generator driven by an internal-combustion engine is used for emergency electric source. These types of generators have to maintain a certain range of output voltage even under the sudden load change conditions such as full load application and removal. This paper describes a method for suppressing the output voltage of a synchronous generator that operates excessively when the load fluctuates. The method used in this paper is a feedforward control method in which the main voltage control consists of a feedback loop using a typical PID controller and the load current is detected as a disturbance element and compensated directly. A feedforward system is constructed in which the load current is regarded as disturbance, and the appropriate feedforward controller configuration and parameters are found through simulation. Finally, it can be seen through the experiment that the feedforward control is performed properly. It can be seen that the generator terminal voltage is recovered to the steady state in a short period of time as compared with the existing PID control method even when the entire load of the generator is changed.

LDO Regulator with Improved Regulation Characteristics and Feedback Voltage Buffer Structure (Feedback Buffer 구조 및 향상된 Regulation 특성을 갖는 LDO regulator)

  • Jung, Jun-Mo;Park, Tae-Ryong
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.462-467
    • /
    • 2022
  • The feedback buffer structure is proposed to alleviate the overshoot and undershoot phenomenon and the regulation of the output voltage. The conventional LDO regulator undergoes a regulation voltage change caused by a constant load current change. An LDO regulator with a feedback voltage sensing structure operates in the input voltage range of 3.3 to 4.5 V and has a load current of up to 150 mA at output voltage of 3 V. According to the simulation results, a regulation value of 6.2 mV was ensured when the load current uniformly changed to 150 mA.