• Title/Summary/Keyword: load transfer efficiency

Search Result 223, Processing Time 0.036 seconds

Numerical Study on the Effects of Geosynthetic Reinforcement on the Pile-supported Embankment (수치해석을 통한 성토지지말뚝에 대한 토목섬유 보강 효과 분석)

  • Lee, Su-Hyung
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.2
    • /
    • pp.276-284
    • /
    • 2009
  • Recently pile-supported embankments have emerged as an optimum method when the rapid construction and strict deformation of structures are required on soft soils. Especially geosynthetic-reinforced and pile-supported (GRPS) embankments are used worldwide as they can provide economic and effective solutions. However the load transfer mechanism in GRPS embankments is very complex, and not yet fully understood. Particularly the purpose and effect of geosynthetic inclusion are ambiguous and considered as an auxiliary measure assisting the arching effect of piles. Numerical parametric study using 3D finite element method has been conducted to investigate the effect of geosynthetic reinforcement on the load transfer mechanism of GRPS embankments. Numerical results suggested that as more stiffer geosynthetic is included, arching effect decreases considerably and the load concentration to the piles mostly caused by tension effect of geosynthetic. This finding is contradictory to the common understanding that geosynthetic inclusion only enhance the efficiency of load transfer. Consequently the design parameters determined from the numerical analyses are compared with those of three existing design methods. The problems of the existing methods are discussed.

A Power Regulation and Harmonic Current Elimination Approach for Parallel Multi-Inverter Supplying IPT Systems

  • Mai, Ruikun;Li, Yong;Lu, Liwen;He, Zhengyou
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1245-1255
    • /
    • 2016
  • The single resonant inverter is widely employed in typical inductive power transfer (IPT) systems to generate a high-frequency current in the primary side. However, the power capacity of a single resonant inverter is limited by the constraints of power electronic devices and the relevant cost. Consequently, IPT systems fail to meet high-power application requirements, such as those in rail applications. Total harmonic distortion (THD) may also violate the standard electromagnetic interference requirements with phase shift control under light load conditions. A power regulation approach with selective harmonic elimination is proposed on the basis of a parallel multi-inverter to upgrade the power levels of IPT systems and suppress THD under light load conditions by changing the output voltage pulse width and phase shift angle among parallel multi-inverters. The validity of the proposed control approach is verified by using a 1,412.3 W prototype system, which achieves a maximum transfer efficiency of 90.602%. Output power levels can be dramatically improved with the same semiconductor capacity, and distortion can be effectively suppressed under various load conditions.

An Experimental Study on the Effects of a Radiation Shield on the Thermal Load of a Cryochamber (복사 차폐막이 극저온 용기의 부하에 미치는 영향에 관한 실험적 연극)

  • Kim, Young-Min;Park, Seong-Je;Kang, Byung-Ha
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.365-370
    • /
    • 2005
  • Infrared (lR) detectors are widely used for such applications as thermoelstic stress analysis, medical diagnostics and temperature measurement. Infrared detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Cryochamber considers the conduction heat transfer through a cold finger, the gases conduction and radiation heat transfer. The thermal loads of an infrared detector Cryochamber with radiation shield are investigated experimentally in present study. Since the effect of radiation heat transfer on thermal loads is significant, radiation shields is installed in the cold finger part to protect heat input through radiation. It is found that the thermal load can be substantially reduced by increasing the number of radiation shield.

  • PDF

An Experimental Study on the Thermal Load of a Cryochamber with Radiation Shields (복사 차폐막이 설치된 극저온 용기의 열부하 특성에 관한 실험적 연구)

  • Kim, Young-Min;Kang, Byung-Ha;Park, Seong-Je
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.1
    • /
    • pp.11-16
    • /
    • 2008
  • Infrared (IR) detectors are widely used for such applications as thermoelastic stress analysis, medical diagnostics and temperature measurement. Infrared detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Thermal load of a cryochamber is attributed to the conduction heat transfer through a cold finger, the gases conduction and radiation heat transfer. The thermal loads of an infrared detector cryochamber with a radiation shield are investigated experimentally in present study. Since the effect of radiation heat transfer on thermal loads is significant, radiation shields is installed in the cold finger part to protect heat input through radiation.

A Study on the Characteristics of Refrigerating System according to the Condensation and Evaporation Load (응축 및 증발 부하에 따른 냉동시스템 특성에 관한 연구)

  • Choi, Seung-Il;Ji, Myoung-Kuk;Lee, Dae-Chul;Jeong, Hyo-Min;Chung, Han-Shik
    • Journal of Power System Engineering
    • /
    • v.17 no.3
    • /
    • pp.44-49
    • /
    • 2013
  • The refrigerating system are high efficiency and comfortable due to the automation of the system as well as enhance energy saving are contributing to driving system. Previous study the rotational frequency of the compressor was confined to the fixed condition have changed load of evaporator and condenser related about the refrigerator performance characteristic according to the evaporation load and condensation load change tries to be analyze through the experiment. The useful data for the economic driving of the freezing apparatus tries to be drawn. Consequently, it confirmed that refrigerant in the compressor overheated and as the evaporation load increased the specific volume was increased and the coolant circulation rate decreased. In confirmed that condensation load increased the compression ratio and discharge gas temperature increased. It reduced the low-temperature efficiency and condensation calorie and the quality factor was decreased.

Broadband Impedance Matching Circuit Design for PLC Coupler Using Tchebycheff Equalizer

  • Kim, Gi-Rae;Tangyao, Xie
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.2
    • /
    • pp.113-118
    • /
    • 2009
  • This paper is about design broadband impedance matching circuit for Coupler to improve power transfer efficiency in the power line communication (PLC) system. The Tchebycheff gain function algorithm is represented to design broadband matching circuit. A practical PLC Coupler impedance matching circuit is designed, and the characteristics for S11 and S21 of PLC coupler are enhanced comparing with unmatched one. This is done by maximizing the power transfer gain from modem to the load.

Design of Broadband Impedance Matching Circuit for PLC Coupler using Butterworth Equalizer

  • Xie, Tangyao;Kim, Gi-Rae
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.3
    • /
    • pp.258-262
    • /
    • 2010
  • This paper represents design broadband impedance matching circuit for Coupler to improve power transfer efficiency in the broadband power line communication(BPLC) systems. The Butterworth gain function equalizer is used to design broadband matching circuit. A practical PLC Coupler impedance matching circuit is designed, and the characteristics for S11 and S21 of PLC Coupler are enhanced comparing with unmatched one. This is done by maximizing the power transfer gain from modem to the load.

The Heat Transfer and Thermal Stress Analysis on the Ceramic Core of the Matrix-type Recuperator (MATRIX형 세라믹 열교환기 코아의 열전단 및 열응력해석)

  • Park, Yong-Hwan;U, Chang-Su
    • 연구논문집
    • /
    • s.24
    • /
    • pp.151-159
    • /
    • 1994
  • The heat transfer and thermal stress analysis was performed on the ceramic core of the matrix-type recuperator. The efficiency was calculated as 34% to 65%. Triple-pass arrangement provided higher preheated air temperatures, lower thermal stresses and the increase of pressure drops. Higher temperature gradients and maximum peak stresses appeared on the corners of the ceramic core. The effect of boundary conditions was significant and the use of spring-load sealing mechanism could release thermal stresses.

  • PDF

Method to Optimize Maximum Efficiency in MIMO WPT (MIMO WPT 시스템의 최대 효율을 위한 최적화 방법)

  • Lee, Hyeongwook;Boo, Seunghyun;Na, Sehun;Lee, Bomson
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.4
    • /
    • pp.286-289
    • /
    • 2019
  • In this paper, we proposed a method to control input powers and receiver loads for maximum efficiency in multiple-input multiple-output(MIMO) wireless power transfer(WPT) systems. The input voltage ratio between transmitters and receiver loads for maximum transfer efficiency is derived in terms of figure of merits. The theoretically derived input voltages for the transmitters and optimum loads for the receivers were found to be similar to those obtained by a genetic algorithm. We demonstrate the effectiveness of the theory using a few design examples. Using the results obtained from this study, effective and simplified designs of MIMO WPT systems will be possible.

Regulated Peak Power Tracking (RPPT) System Using Parallel Converter Topologies

  • Ali, Muhammad Saqib;Bae, Hyun-Su;Lee, Seong-Jun;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.870-879
    • /
    • 2011
  • Regulated peak power tracking (RPPT) systems such as the series structure and the series-parallel structures are commonly used in satellite space power systems. However, these structures process the solar array power or the battery power to the load through two cascaded regulators during one orbit cycle, which reduces the energy transfer efficiency. Also the battery charging time is increased due to placement of converter between the battery and the solar array. In this paper a parallel structure has been proposed which can improve the energy transfer efficiency and the battery charging time for satellite space power RPPT systems. An analogue controller is used to control all of the required functions, such as load voltage regulation and solar array stabilization with maximum power point tracking (MPPT). In order to compare the system efficiency and the battery charging efficiency of the proposed structure with those of a series (conventional) structure and a simplified series-parallel structure, simulations are performed and the results are analyzed using a loss analysis model. The proposed structure charges the battery more quickly when compared to the other two structures. Also the efficiency of the proposed structure has been improved under different modes of solar array operation when compared with the other two structures. To verify the system, experiments are carried out under different modes of solar array operation, including PPT charge, battery discharge, and eclipse and trickle charge.