• Title/Summary/Keyword: load test

Search Result 8,113, Processing Time 0.04 seconds

The Equivalent Circuit, The Graphically Calculating Method Of The Characteristics, And The Calculating Method By Determination Of Equivalent Circuit Parameters In Single Phase Induction Motor (단순상유도전동기의 등가회로와 도식적 특성산정법 및 정수결정에 의한 특성산정법)

  • Keung Yul Oh
    • 전기의세계
    • /
    • v.22 no.1
    • /
    • pp.42-51
    • /
    • 1973
  • The contriving equivalent circuit of single phase induction motor which does not separate the primary leakage reactance and the secondary leakage reactance by the revolving field theory, and the graphically calculating method of the characteristics with T-type circle diagram of three phase induction motor which does not suppose the primary leakage reactance can be drawn up only by the no load test, the lock test, and measuring the resistance of stator winding are suggested in this paper. The method which can calculate the parameters of the equivalent circuit and the characteristics with no load test, lock test and measuring resistance of stator windings is suggested in this paper. Considered the exciting current in lock test, we could calculate very accurate characteristics of the single phase induction motor.

  • PDF

A study on design and control of hydraulic test rig for performance evaluation of active suspension system (능동 현가시스템의 성능평가를 위한 유압식 시험기의 설계 및 제어에 관한 연구)

  • 손영준;이광희;이진걸
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1445-1449
    • /
    • 1996
  • To evaluate of active suspension, it is necessary for special equipment - so called Test Rig which can perfectly realize the road condition and the impact from the road. And most of the test rig systems controlling force accurately and rapidly consist of electro-hydraulic servo mechanism, and they need robust controller which can endure outer road change. But in the case of PID controller, we should choose its best gains by trial and error method, and once its gains are fixed, they cannot get changed, so we should reset PID controller gains respectively when the road is changed. Therefore based on the load pressure feedback compensation method, our aim at constructing electro-hydraulic test rig is not affected by various road disturbance.

  • PDF

Vibration Control of Tower Structure under Wind Load (풍하중에 의한 타원형 구조물의 진동 제어)

  • Hwang Jae-Seung;Kim Yun-Seok;Joo Seok-Jun
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.427-430
    • /
    • 2002
  • The present parer outlines the system identification and vibration control performance of air traffic control tower of Yangyang international airport with tuned mass damper(TMD). From the free vibration test, natural frequency, damping ratio and mode shape of tower are obtained and these values are compared with the values from numerical analysis. In the vibration control test to evaluate the vibration control performance, equivalent damping ratio increased by tuned mass damper are obtained in case the TMD is operated as passive mode. Damping ratio of tower evaluated from free vibration test is about $1.0{\%}$. It is very low value than damping ratio recommended in general code. Damping ratio of passive mode is about $5{\%}$. These equivalent damping ratio increased by TMD is enough to enhance the serviceability of tower structure under wind load.

  • PDF

A Study On Full Load Test of IGBT Type Propulsion System for Electric Railway in SMG 6 Line (전동차용 IGBT형 추진제어장치의 6호선 본선 만차 시험에 관한 연구)

  • 박건태;정만규;고영철;방이석;서광덕
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.666-673
    • /
    • 2000
  • This paper describes the full load test results of IGBT VVVF inverter for the railway propulsion system. The 1,650kVA IGBT VVVF inverter has been developed. Therefore, the field test is performed in SMG 6 Line to confirm its the reliability and performance. The train consists of 4M4T(4 Motor car 4 Trailer Car) and the electrical equipment for field test are as follows VVVF inverter 4 sets, 16 traction motors and 2 SIVs. The propulsion system is composed with IC4M(1-Controller 4-Motors). The results of propulsion system which have the excellent acceleration/deceleration and the jerk characteristics as well as starting ability on slope are taken through the field test.

  • PDF

Estimation of Running Safety of Electric Multiple Unit for Express Train in Incheon International Airport Railway (인천국제공항철도 직통형 차량의 주행안전성 평가)

  • Ham, Young-Sam;Seo, Jung-Won;Hur, Hyun-Moo;Lee, Dong-Hyung;Kwon, Seok-Jin;Kwon, Sung-Tae;Hong, Yong-Ki;Park, Ok-Jeoung
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.109-114
    • /
    • 2007
  • For the safety of railway, it should be evaluated for the running safety by measuring the derailment coefficient. Although railway has run the fixed and maintained rail, some of railway is derailed. This report shows the results that performed the static load test, wheelset manufacturing for test, main line running test on the basis of the derailment theory and experience. It is executed main line test to 120 km/h for estimating the running safety of express train in Incheon International Airport. As the test results, could confirm the curving performance and running safety of Incheon International Airport EMU from the results of the wheel unloading, lateral force, derailment coefficient etc. Derailment coefficient was less than 0.8, and lateral force allowance limit and wheel load reduction ratio were enough safe.

  • PDF

A Study on the Parameters and Characteristics of Induction Motor Driven by Inverter (인버터로 구동되는 유도전동기의 정수 및 특성에 관한 연구)

  • 전내석;김종윤;오진석;김윤식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.6
    • /
    • pp.34-42
    • /
    • 2000
  • In this paper conventional technique will be described, which can be used for the measuring various parameters of induction motor. This is followed by presenting some other, alternative, techniques. The two tests are described which are suitable to obtain the electrical parameters of symmetrical 1hp three-phase squirrel-cage induction motor. These are the blocked rotor test and no load test. By the application of these, it is possible to determine the parameters which are presented in the steady-state equivalent-circuit of determining an induction motor. One conventional method of determining the inertia of an induction motors is obtained by performing retardation tests. The angular rotor speed of the motor is monitored, following its disconnection from the stator supply. Since the inertia torque J dw/dt contains the inertia coefficient J and the friction and windage torque Bw contains the coefficient B, then J and B can be determined by performing retardation tests.

  • PDF

Structural Analysis and Topology Optimization of an Automotive Pedal Arm Considering Qualification Test Specifications (시험 규격을 고려한 자동차 페달 암의 구조해석과 위상최적화)

  • Lee Boo-Youn;Lee Hyun-Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.5
    • /
    • pp.562-571
    • /
    • 2006
  • Finite element analysis is performed to evaluate structural reliability of an automotive pedal arm under conditions of the stiffness, the load and the endurance test specifications. Results of the analysis shows that the pedal arm is safe enough under the tests. A topology optimization is numerically implemented, overall shape of the pedal arm being verified to be reasonable, A design concept to insert holes in the arm is established, which may be used to reduce its weight.

Characteristics Analysis of Electromagnetic Pump using Linear Induction Motor (선형유도전동기를 이용한 전자기 펌프의 특성해석)

  • 김창업
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.2
    • /
    • pp.36-42
    • /
    • 2000
  • This paper presents the characteristics analysis of electromagnetic pump using linear induction motors. The electromagnetic pump is designed to transfer the molten metals by the electromagnetic force of linear induction motors. The characteristics f a linear induction motor are analysed by the equivalent circuit method considering the end effects. For the verification of the analysis method, the locked test and load test with molten tin were made. The test results of locked test were compared with the simulations, and the velocity of the load test with molten zinc showed 0.24[m/x] with air gap 30[gap] which is sufficient for transferring molten tin.

  • PDF

Study on Vibration Fatigue Analysis of Automotive Battery Supporter (자동차 배터리 지지 구조의 진동 피로 해석에 대한 연구)

  • Ah, Sang Ho
    • Journal of Auto-vehicle Safety Association
    • /
    • v.11 no.4
    • /
    • pp.22-27
    • /
    • 2019
  • In this paper, the vibration load and analysis results for automotive battery supporter were performed to provide efficient vibration tolerance performance prediction methods for single-product vibration tolerance testing, and the major influencing factors and considerations for setting up single-unit vibration tolerance tests were reviewed. A common applicable standard load was applied to efficiently predict the performance of single-unit vibrations through the frequency response analysis technique. The results similar to test results can be predicted by checking vulnerable parts of the vehicle components for vibration loads and applying scale factor to standard loads. In addition, it was confirmed that the test conditions with a frequency generating the same durability severity as the endurance test are needed for accurate prediction of the durability of the single-unit vibration tolerance test conditions, and the acceleration and frequency with the conditions that there is no significant nonlinear phenomena in the vibration system are established during the single-unit vibration tolerance test conditions.

Durability Test for the Expansion Joint of High-Speed Railway Bridge (고속철도 교량 신축이음장치의 내구성 실험)

  • 김병석;곽종원;신호상;김영진;박성용;장익순
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.894-899
    • /
    • 1998
  • To absorb the deformation of live load, thermal gradient, shrinkage and creep in bridge structures and general structures, expansion joint has to be established. Especially expansion joint for high-speed railway bridge has to accomodate the static and dynamic forces and it not only has the durability of itself but also maintain the durability of structure by preventing the leakage of water. The actual used product of expansion joint for high-speed railway bridge is only ones made in France, Germany and Japan. In this study, the development process and test results of developed expansion joint are introduced which has the functional operation and durability enough to apply to high-speed railway bridges, roadway bridges and general structures. The tests consist of fatigue-durability test of 3 million times by high-speed rail load, leakage test and jack-up test for verifying the possibility of exchanging it. The performance of developed expansion joint satisfy the specification of Korea High Speed Rail Construction authority.

  • PDF