• Title/Summary/Keyword: load regulation

Search Result 530, Processing Time 0.028 seconds

Novel Active Voltage Quality Regulator with Adaptive DC-Link Voltage Control

  • Xiao, Guochun;Zeng, Zhong;Liu, Kai;Hu, Zhiliang;Wang, Zhaoan
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.880-889
    • /
    • 2011
  • In this paper, a novel Active Voltage Quality Regulator (AVQR) topology with a thyristor rectifier and an adaptive dclink voltage control strategy are proposed. The proposed AVQR can efficiently mitigate the long duration variations (e.g. undervoltages/overvoltages), voltage imbalances and voltage harmonics. Compared with conventional AVQRs, it can regulate the load voltage very well with a much lower dc-link voltage. This is accomplished by replacing the diode rectifier with a thyristor rectifier. Moreover, its dc-link voltage can vary with the deviations of the supply voltage through the proposed adaptive dc-link voltage control strategy. All of these contribute to its significantly higher efficiency for online operating, which is very important and attractive for many applications. The proposed topology and control strategy are theoretically analyzed in detail. Simulation results are also provided in the paper. Finally, the feasibility and effectiveness of the proposed method are verified by means of experimental results from a 2kVA prototype. Both of the simulation and experimental results show that the proposed AVQR can achieve a much higher efficiency and similar regulation performance when compared with the conventional ones.

A Study on Characteristics of Power Generation System Using Biogas from the Waste of Pig Farm

  • Huynh, Thanh-Cong;Pham, Xuan-Mai;Nguyen, Dinh-Hung;Tran, Minh-Tien
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.5
    • /
    • pp.435-441
    • /
    • 2010
  • To verify the possibility of a power generation system using biogas from the waste of pig farm for rural electric production, a SI gasoline engine is modified to use biogas fuel and was installed in a 20 KVA power generation system. An electronic speed regulation unit is developed to keep the system speed at 1500 rpm. Experimental investigations have been carried out to examine the performance characteristics of power generation system (such as: system frequency, phase output voltage,$\ldots$). In addition, the operating parameters and output emissions ($NO_x$, HC, and $CO_2$) of biogas-fueled engine are preliminary evaluated and analyzed for the change of system load. Results indicated that the researched power generation system shows a high stability of output voltage and frequency with help of speed regulator. Biogas fuel (mainly $CH_4$ and $CO_2$) has an environmental impact and potential as a green alternative fuel for SI engine and they would not require significant modification of existing engine hardware. Output emissions of biogas-fueled engine are found to be relative low. $NO_x$ emission increases with the increase of output electric power of the power generation system.

A Study on the Landscape Planning Evaluation on Apartment Artificial Ground (아파트 단지 인공지반의 계획적 평가에 관한 연구)

  • 김유일;오정학;김인혜;윤홍범
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.26 no.3
    • /
    • pp.297-311
    • /
    • 1998
  • Landscaping on artificial ground is currently served as a means to imposing a greenery benefit on high-density and high-rise apartment sites. It functions as a sub-hierarchy in apartment planning such as ornamental element from the past. Major parking space tends to be allocated on the basement area in response to the required parking regulation. Therefore, competitive relatioinship between the parking and greenery space I limited outdoor of apartments leads to the development planning strategy and technology of artificial ground. This study aims at evaluating landscape planning on artificial ground of apartment complex through several approaches such as site survey, plan drawing analysis, and interview with related field experts. 15 survey apartment sites including Bundang Model, Shindaebang-dong, Pyoungchon Hyundai Apartments have been selected for conducting the research. Main results of this study are summarized below : First, scattering allocation of artificial ground between apartment building units is a dominant plan layout type among the survey sites. Even though unifying allocation type has an advantage to maximize underground parking space, it has a difficulty in maintaining proper soil ground base for nurturing plants. Therefore, underground parking space should be planned by unifying allocation type placed separately from apartment units. This plan type can provide a balanced planting between soil and artificial ground on surface level. Second, It is strongly recommended to integrate the whole planting base which involves architectural structure, drainage, and water proofing above the planting design. When considering that process as a professional subject dealing with natural material such as trees and shrubs, those tasks should be directed by landscape architectural divison and landscape architect. And planting area for artificial ground has to be specified in initial phase of architectural design. This step provides an opportunity to make a proper decision on structural load, drainage, and water proof design as an integrated part of the management.

  • PDF

Hold up Time Extension Technique for high efficiency, high power density server power supply (고효율 고밀도 서버용 전원장치를 위한 Hold up Time 보상 기술)

  • Kim, Young-Do;Cho, Kyu-Min;Moon, Gun-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.96-102
    • /
    • 2010
  • Nowadays, climate change becomes serious problem in all around country. Especially because of global warming problem, every country is suffered from various natural disasters. To prevent these changes, every industry are keep requiring the increase in energy efficiency. Recently, in the regulation of CSCI (climate savers computing initiate), the efficiency of server power supply should meet the demand of 94% at 50% load condition by 2010, which is called platinum level. Hence, server power system has been dramatically developed with the various technique for the high efficiency of it. Among those technique, hold up time extension technique has received wide attention and has been researched for a long time. In this paper, technical trend of hold up time extension circuit will be covered for the high efficiency, high power density server power supply.

A Study on Efficiency of Tapered Roller Bearing for an Automatic Transmission (승용차 자동변속기용 테이퍼 롤러 베어링의 효율개선 연구)

  • Lee, In-Wook;Han, Sung Gil;Shin, Yoo In;Song, Chul Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.5
    • /
    • pp.30-36
    • /
    • 2018
  • Automotive fuel efficiency regulations and air pollution control are hot issues of recent years in the automotive industry. To solve these regulation problems, many studies are continuing to improve the transmission efficiency of transmissions. Tapered roller bearings are useful to improve the transmission efficiency in the recent automobile parts. The frictional losses in the tapered roller bearings are mainly composed of the rolling friction and the sliding friction, and are dependent upon the load, the lubrication, the rotation speed of bearings, and etc. In this paper, the operating conditions of the transmission are defined and then the power losses of each bearing are calculated. In addition, improvement options are suggested after identifying the design factors influenced much by the improvement effect of power loss under the operating conditions of each bearing. We compare the power losses of the entire transmission system due to bearing improvements by comparing the friction losses between the original design and the improved design. Lastly, it is shown that the calculated power losses are valid by comparing the test values and the theoretical values for the frictional torque characteristics of the original and improved bearings.

Performance Improvement in Single-Phase Electric Spring Control

  • Wang, Qingsong;Zuo, Wujian;Cheng, Ming;Deng, Fujin;Buja, Giuseppe
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.784-793
    • /
    • 2019
  • Two objectives can be pursued simultaneously with the ${\delta}$ control of a single-phase electric spring (ES). These objectives are the stabilization of the voltage across the critical load (CL) of a power system, and the achievement of a specific functionality similar to the pure compensation of reactive power or the correction of the power factor. However, existing control systems implementing the ${\delta}$ control do not cope with non-ideal operating conditions, such as line voltage distortions, and exhibit a somewhat sluggish regulation of the CL voltage. In an effort to improve both the steady-state and transient performances of an ES power system, this paper proposes implementing the ${\delta}$ control by means of a control system built up on the repetitive control and assisted by state feedback with pole assignment. This paper starts by analyzing the dynamics of an ES power system in terms of its poles and zeros. After that, a reduced second-order model of the dynamics is formulated to avoid a notch filter in the pole assignment. A repetitive control for an ES power system is then designed to meet the two above mentioned objectives. Experimental tests carried out on a laboratory setup demonstrate the effectiveness of the proposed control system in significantly improving the ES power system performance, while reaching the two objectives. In particular, the tests outline the large mitigation of harmonics in the CL voltage under line voltage distortions and its fast stabilization action.

Toxoplasma gondii Induces Apoptosis via Endoplasmic Reticulum Stress-Derived Mitochondrial Pathway in Human Small Intestinal Epithelial Cell-Line

  • Wang, Hao;Li, Chunchao;Ye, Wei;Pan, Zhaobin;Sun, Jinhui;Deng, Mingzhu;Zhan, Weiqiang;Chu, Jiaqi
    • Parasites, Hosts and Diseases
    • /
    • v.59 no.6
    • /
    • pp.573-583
    • /
    • 2021
  • Toxoplasma gondii, an intracellular protozoan parasite that infects one-third of the world's population, has been reported to hijack host cell apoptotic machinery and promote either an anti- or proapoptotic program depending on the parasite virulence and load and the host cell type. However, little is known about the regulation of human FHs 74 small intestinal epithelial cell viability in response to T. gondii infection. Here we show that T. gondii RH strain tachyzoite infection or ESP treatment of FHs 74 Int cells induced apoptosis, mitochondrial dysfunction and ER stress in host cells. Pretreatment with 4-PBA inhibited the expression or activation of key molecules involved in ER stress. In addition, both T. gondii and ESP challenge-induced mitochondrial dysfunction and cell death were dramatically suppressed in 4-PBA pretreated cells. Our study indicates that T. gondii infection induced ER stress in FHs 74 Int cells, which induced mitochondrial dysfunction followed by apoptosis. This may constitute a potential molecular mechanism responsible for the foodborne parasitic disease caused by T. gondii.

Investigation of the Bonding Stress of the 2nd Barrier for LNG Carrier Cargo Containment System Considering Various Working Conditions (다양한 작업 조건을 고려한 LNG 운반선 화물창 2차 방벽의 극저온 접착강도 분석)

  • Jeong-Hyeon Kim;Hee-Tae Kim;Byeong-Kwan Hwang;Seul-Kee Kim;Tae-Wook Kim;Doo-Hwan Park;Jae-Myung Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.3
    • /
    • pp.499-507
    • /
    • 2023
  • The core of the liquefied natural gas (LNG) carrier cargo containment system (CCS) is to store and transport LNG safely under temperatures below -163 degrees Celsius. The secondary barrier of the LNG CCS is adopted to prevent LNG leakage from CCS to the ship's hull structure. Recently, as the size of the LNG CCS increases, various studies have been conducted on the applied temperature and load ranges. The present study investigates the working condition-dependent bonding strength of the PU15 adhesives of the secondary barrier. In addition, the mechanical performance is analyzed at a cryogenic temperature of -170 degrees Celsius, and the failure surface and failure mode are investigated depending on the working condition of the bonded process. Even though the RSB and FSB-based fracture mode was confirmed, the results showed that all the tested scenarios satisfied the minimum requirement of the regulation.

Design of eFuse OTP Memory with Wide Operating Voltage Range for PMICs (PMIC용 넓은 동작전압 영역을 갖는 eFuse OTP 설계)

  • Jeong, Woo-Young;Hao, Wen-Chao;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.1
    • /
    • pp.115-122
    • /
    • 2014
  • In this paper, reliability is secured by sensing a post-program resistance of several tens of kilo ohms and restricting a read current flowing over an unblown eFuse within $100{\mu}A$ since RWL driver and BL pull-up load circuits using a regulated voltage of V2V ($=2V{\pm}10%$) are proposed to have a wide operating voltage range for eFuse OTP memory. Also, when a comparison of a cell array of 1 row ${\times}$ 32 columns with that of 4 rows ${\times}$ 8 columns is done, the layout size of 4 rows ${\times}$ 8 columns is smaller with $187.065{\mu}m{\times}94.525{\mu}m$ ($=0.01768mm^2$) than that of 1 row ${\times}$ 32 columns with $735.96{\mu}m{\times}61.605{\mu}m$ ($=0.04534mm^2$).

Soil Modelling Method to Design Bent Foundation with Drilled Shaft Pier (단일 현장타설말뚝의 설계시 지반 모델링 방법)

  • Jeon, Kyung-Soo;Han, Kyoung-Bong;Song, Pil-Young
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.368-376
    • /
    • 2010
  • The bent foundation with single drilled shafts is suitable and economical in South Korea, which has good rock in a shallow depth. This foundation has been designed with an elastic design concept. To apply a plastic design concept written in Korea Bridge Design Criteria, a detail design regulation, which includes the method for a plastic hinge point to occur above the ground, rebar arrangement and soil modelling, should be defined. Soil modelling should be considered in the respect of structural engineer's practicality. In this paper, single drilled shaft piers with 1m diameter are constructed, and cyclic lateral load tests loaded at 4m above the ground are taken to examine the behavior. Reduced diameter shaft above the ground and remaining the steel casing under the ground were used to induce plastic hinge to occur above the ground. Simplified soil models such as elastic relation and p-y curve are adapted, and the prediction results are compared with test results. Prediction results of a model bridge were compared according to soil models with time domain analyses, and design criteria of soil were proposed.

  • PDF