• 제목/요약/키워드: load ratio

검색결과 3,937건 처리시간 0.03초

철근비 변화에 따른 철근콘크리트 기둥의 거동에 관한 실험적 연구 (An Experimental Study on the Behavior of Reinforced Concrete Columns Subjected Longitudinal Steel Ratio.)

  • 조성찬;장정수;김광석;박진희;김윤용;한상훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.284-292
    • /
    • 1995
  • This paper is on experimental study on the behavior of reinforced concrete columns subjected to longitudinal steel ratio To investigate the effects of concrete strength and longitedinal steel ratio on the behavior of reinforced concrete columns. a series of tests were carried out for thirty-six tied reinforced concrete columns with a 100mm square cross section and three slendemess ratio of 15, 30 and 50. And To study and illustrate the change of the ultimate loads and that of displacements, two different concrete strength of 180,26kfg/$\textrm{cm}^2$, 819,36kfg/$\textrm{cm}^2$ and five different longitudinal steel ratio of 0.5, 1.0, 4.0, 5.7 and 10.3% were used. The boundary conditions at the ends were both hinged and the end eccentricities (17mm) were equal and of the same sign. While the ultimate load capacity of high-strength concrete column was much increased when the columns were short, that was not when the columns were slender. The effect of longitudinal steel ratio on the increased of ultimate load of column was more evident for slender columns than for short ones and the ultimate of longitudinal steel ratio were more pronounced with increasing concrete strength. The more inserted the longitudinal steel, the more increased the ultimate load, but the superabundance of longitudinal steel ratio over the limitation of maximum steel ratio in ACI code was used, it was showed that the ultimate load was rather decreased.

  • PDF

Seismic behavior of composite walls with encased steel truss

  • Wu, Yun-tian;Kang, Dao-yang;Su, Yi-ting;Yang, Yeong-bin
    • Steel and Composite Structures
    • /
    • 제22권2호
    • /
    • pp.449-472
    • /
    • 2016
  • This paper studies the seismic behavior of reinforced concrete (RC) walls with encased cold-formed and thin-walled (CFTW) steel truss, which can be used as an alternative to the conventional RC walls or steel reinforced concrete (SRC) composite walls for high-rise buildings in high seismic regions. Seven one-fourth scaled RC wall specimens with encased CFTW steel truss were designed, manufactured and tested to failure under reversed cyclic lateral load and constant axial load. The test parameters were the axial load ratio, configuration and volumetric steel ratio of encased web brace. The behaviors of the test specimens, including damage formation, failure mode, hysteretic curves, stiffness degradation, ductility and energy dissipation, were examined. Test results indicate that the encased web braces can effectively improve the ductility and energy dissipation capacity of RC walls. The steel angles are more suitable to be used as the web brace than the latticed batten plates in enhancing the ductility and energy dissipation. Higher axial load ratio is beneficial to lateral load capacity, but can result in reduced ductility and energy dissipation capacity. A volumetric ratio about 0.25% of encased web brace is believed cost-effective in ensuring satisfactory seismic performance of RC walls. The axial load ratio should not exceed the maximum level, about 0.20 for the nominal value or about 0.50 for the design value. Numerical analyses were performed to predict the backbone curves of the specimens and calculation formula from the Chinese Code for Design of Composite Structures was used to predict the maximum lateral load capacity. The comparison shows good agreement between the test and predicted results.

고온화재조건 콘크리트 라이닝의 하중비에 따른 폭렬영향성 및 화재손상특성에 관한 실험적 연구 (An Experimental Study on the Thermal Property of Concrete under the Load Ratio Condition in Fire)

  • 김형준;김흥열;박경훈;안찬솔;권기혁
    • 한국화재소방학회논문지
    • /
    • 제24권3호
    • /
    • pp.145-151
    • /
    • 2010
  • 터널의 화재는 초동진압에 실패할 경우 터널의 내부는 상당한 화재하중이 존재하고, 제연설비의 영향으로 화재전파속도가 빨라 단시간 내에 화재의 확산과 함께 고온으로 발전하여 터널 구조체 및 인명에 대한 피해를 증대시킨다. 이에 본 연구에서는 초기 가장 급격한 온도상승이 발생하는 시나리오인 MHC(Modified Hydrocarbon) 화재곡선을 대상으로 하중비를 0, 20, 40, 60, 70%를 조정한 화재실험을 수행하여 하중재하에 의한 콘크리트 폭렬영향성 및 화재손상범위에 대한 열적특성을 규명하고자 하였다. 실험체는 EFNARC에서 규정한 소규모 실물실험체 형상조건을 준용하였으며, 배합강도는 일반강도인 24MPa로 실험제반조건을 선정하였다. 실험수행결과 비재하조건의 라이닝의 경우 16mm의 폭렬이 발생하였으나 하중비 20%와 40%에서는 폭렬이 발생하지 않았다. 재하 하중비를 증가시킨 60%의 경우 24mm의 폭렬이 발생하였으며, 70% 재하조건의 경우 가열시작 10분 이후에 파괴되었다.

샌드위치식 복합구조체의 셀(Cell)형상비가 거동과 성능에 미치는 영향 (Effect of Span-to-Depth Ratio on Behavior and Capacity in Composite Structure of Sandwich System)

  • 정연주;정광회;김병석;박성수;황일선
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2000년도 추계학술대회 논문집
    • /
    • pp.73-78
    • /
    • 2000
  • This paper describes the effect of span-to-depth ratio, which describes aspect of cell formed with top diaphragm steel plate, on capacity in composite steel-concrete structure of sandwich system. The span-to-depth ratio \ulcorner load-carrying mechanism and load-distribution capacity of structure. Therefore, stress levels of members and load-resis\ulcorner of system vary according to span-depth ratio. In this study, numerical nonlinear analysis was performed to various ratio for two types(MA, MB) composite structure of sandwich system to analyze the influence of span-to-depth ratio or, behavior. The difference of load-carrying mechanism and stress of members results from analysis results, then bas\ulcorner differences, the effects of span-to-depth ratio on shear capacity, flexural capacity and load-resistance capacity were analyze effects on failure mode and ductility were briefly. As a results of this study, as span-to-depth ratio increases, \ulcorner bottom steel plate and concrete lower. This implies an increase in effective flexural and shear capacity. Therefore lo\ulcorner capacity of structure improves as span-to-depth ratio increases, Especially, the effect is greate in shear than flexural span-to-depth ratio increases, this difference between flexural and shear capacity may change failure mode and ductility. span-to-depth ratio increases capacity increases more than flexural capacity, we should expect that structural behavior mode gradually change from shear to flexural and ductility of structure gradually improves.

  • PDF

전단지간비에 따른 철근콘크리트 보의 전단강도특성에 관한 연구 (A Study on the Shear Strength Properties of Reinforced Concrete Beams according to Shear Span-Depth Ratio)

  • 박종건
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권1호
    • /
    • pp.93-100
    • /
    • 2000
  • The purpose of this study is to investigate the shear behavior of reinforced concrete beams according to small shear span-depth ratio between a/d=1.5, 2.8, 3.6. In general, shear strength of reinforced concrete beams is dependent on the compressive strength of concrete the longitudinal steel ratio, the shear span-depth ratio and shear reinforcement. The static test was carried out to measure the ultimate load, the initial load of flexural and diagonal cracking, crack patterns, fracture modes. The load versus strain and load versus deflection relations were obtained from the static test. The test results on shear strength were compared with results obtained by the formulas of ACI code 318-95. The shear strength of reinforced concrete beams exceeded those predicted following present ACI code 318-95(11-6).

  • PDF

가정용 목재 펠릿 보일러에 대한 부분부하 운전 특성 (Part Load Performance Characteristics of Domestic Wood Pellet Boiler)

  • 강새별;김종진;김혁주;박화춘;최규성;심봉석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.103.1-103.1
    • /
    • 2010
  • Recently domestic wood pellet boilers are installed in rural and forestry houses. The fuel price per lower heating value of wood pellet is about 20 % lower than that of heating oil on July 2010. In spite of lower price of wood pellet, a few user of wood pellet boiler complain expensive fuel cost. One of this reason is inaccurate or improper air-fuel ratio setting of wood pellet boiler. O2 concentration of flue gas of domestic wood pellet boiler is about 9.7 % and there are few domestic wood pellet boiler which can control air-fuel ratio automatically. We tested a domestic wood pellet boiler in changing boiler thermal output and air-fuel ratio. The nominal boiler thermal output is 25 kW (21 500 kcal/h). We measured thermal efficiency and flue gas concentrations such as CO and NOx at each boiler thermal load with various air-fuel ratio. The results show that if air flow rate is the same as full load and part load, thermal efficiency of part load of 40 % drops about 7.7 %p compared to boiler full load case.

  • PDF

Axial load-strain relationships of partially encased composite columns with H-shaped steel sections

  • Bangprasit, Papan;Anuntasena, Worakarn;Lenwari, Akhrawat
    • Steel and Composite Structures
    • /
    • 제45권1호
    • /
    • pp.51-66
    • /
    • 2022
  • This paper presents the axial compression behavior of partially encased composite (PEC) columns using H-shaped structural steel. In the experimental program, a total of eight PEC columns with H-shaped steel sections of different flange and web slenderness ratios were tested to investigate the interactive mechanism between steel and concrete. The test results showed that the PEC columns could sustain the load well beyond the peak load provided that the flange slenderness ratio was not greater than five. In addition, the previous analytical model was extended to predict the axial load-strain relationships of the PEC columns with H-shaped steel sections. A good agreement between the predicted load-strain relationships and test data was observed. Using the analytical model, the effects of compressive strength of concrete (21 to 69 MPa), yield strength of steel (245 to 525 MPa), slenderness ratio of flange (4 to 10), and slenderness ratio of web (10 to 25) on the interactive mechanism (Kh = confinement factor for highly confined concrete and Kw = reduction factor for steel web) and ductility index (DI = ratio between strain at peak load and strain at proportional load) were assessed. The numerical results showed that the slenderness of steel flange and yield strength of steel significantly influenced the compression behavior of the PEC columns.

사질토 지반에서 시멘트밀크 주입비에 따른 매입말뚝의 수평지지력 (The Lateral Load Capacity of Bored-Precast Pile Depending on Injecting Ratio of Cement Milk in Sand)

  • 홍원표;윤중만
    • 한국지반신소재학회논문집
    • /
    • 제12권4호
    • /
    • pp.99-107
    • /
    • 2013
  • 매입말뚝의 수평저항 특성을 고찰하기 위하여 매입말뚝에 대한 수평재하시험을 실시하여 수평하중과 수평변위관계를 분석하였다. 말뚝수평재하시험은 시멘트 밀크가 말뚝매입길이의 50%, 70%, 100%로 주입된 6개의 말뚝에 대하여 실시하였다. 시멘트 밀크의 주입비(시멘트 밀크 주입길이/말뚝의 길이)는 매입말뚝의 수평변위, 항복하중, 수평지지력에 큰 영향을 미치는 것으로 나타났다. 시멘트 밀크의 주입비가 증가할수록 매입말뚝의 수평변위가 발생되기 시작하는 위치는 지표면에 가까워지며 말뚝의 수평변위는 감소한다. 그리고 말뚝의 수평지지력과 항복하중은 시멘트 밀크 주입비가 증가할 수록 크게 나타났다. 시멘트 밀크 주입비가 1인 매입말뚝의 항복하중과 극한수평지지력은 시멘트 밀크 주입비가 0.5인 경우보다 약 2~3배 정도 크게 나타났다.

검증용 정재하시험 자료를 이용한 항타강관말뚝의 신뢰성 평가 (Reliability Updates of Driven Piles Using Proof Pile Load Test Results)

  • 박재현;김동욱;곽기석;정문경;김준영;정충기
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.324-337
    • /
    • 2010
  • For the development of load and resistance factor design, reliability analysis is required to calibrate resistance factors in the framework of reliability theory. The distribution of measured-to-predicted pile resistance ratio was constructed based on only the results of load tests conducted to failure for the assessment of uncertainty regarding pile resistance and used in the conventional reliability analysis. In other words, successful pile load test (piles resisted twice their design loads without failure) results were discarded, and therefore, were not reflected in the reliability analysis. In this paper, a new systematic method based on Bayesian theory is used to update reliability index of driven steel pile piles by adding more pile load test results, even not conducted to failure, into the prior distribution of pile resistance ratio. Fifty seven static pile load tests performed to failure in Korea were compiled for the construction of prior distribution of pile resistance ratio. Reliability analyses were performed using the updated distribution of pile resistance ratio and the total load distribution using First-order Reliability Method (FORM). The challenge of this study is that the distribution updates of pile resistance ratio are possible using the load test results even not conducted to failure, and that Bayesian update are most effective when limited data are available for reliability analysis or resistance factors calibration.

  • PDF

측벽 부하가 존재하는 공간에 설치된 라인 디퓨져의 ADPI 특성에 관한 연구 (ADPI Characteristics of Line Diffuser in a Room with Perimetric Heating Load)

  • 조영진;강석윤;문종선;이재헌
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1204-1211
    • /
    • 2004
  • It is difficult to apply a conventional selection guide for diffusers when the diffuser is installed in a perimeter zone, because the air diffusion performance index (ADPI) vs. throw/length (T/L) ratio curve listed in conventional guide does not consider the perimetric heating load through the walls. The objective of this study is to evaluate the effect of the perimetric heating load on the ADPI and propose a selection guide for a proper line diffuser when perimetric heating load exists. The velocity and temperature distributions and the ADPI values are obtained numerically with various heat load ratios and air flow rates. The velocity and temperature distributions and the ADPI values are analyzed by CFD in case of various heat load ratios and air flow rates. Also, ADPI was calculated by those results. The ADPI values by numerical results are compared with an existing experimental data to verify the method for the evaluation of ADPI proposed in a present study. In case of a line diffuser installed at the high side wall, the ADPI decreases according to the increases of the flow rate on every heat load ratio of the present study except 0.75. The ADPI vs. T/L ratio curves have been proposed for the heat load ratios of 0.25, 0.5, 0.75 to guarantee the comport thermal environment when diffusers are installed in perimeter zone.