• Title/Summary/Keyword: load pattern

Search Result 1,152, Processing Time 0.029 seconds

Optimum Support Pattern Design of the Tae-Gu Subway Tunnel (대구 지하철 터널의 적정지보패턴 선정에 관한 연구)

  • 지왕률;최재진
    • Tunnel and Underground Space
    • /
    • v.4 no.2
    • /
    • pp.119-131
    • /
    • 1994
  • This is a Double-Track Railway tunnel in typical Tae-Gu black and gray shale forming part of the No.1 Line of the Tae-Gu Subway. The main fault zone at tunnel is a moderately to highly weathered and closely jointed zone, 0.5 m wide with associated paralled jointing which is slickensided and fractured. After excavation by blasting, the soft rocks should need to be reinforced with optimal supporting pattern which might be better redesigned through the consideration of the results of in-situ rock measurements at the field. Performances fo the field tests included Point Load Test, Schmidt Hammer Test, and field joint measurement gave the detail data for the optimum support design and safe excavation of the No.1 Line of Tae-Gu Subway at the No.1-7 consturction site adn the safety of this redesigned supports system was analysed by the FDM program FLAC.

  • PDF

The Effect of Finished Surface orientation on Friction Characteristics (가공방향에 따른 마찰특성에 관한 연구)

  • 유응대;김태완;조용주
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.367-373
    • /
    • 2001
  • The effect of characteristic of surface roughness and roughness patterns on friction and sliding wear was studied experimentally under reciprocating boundary lubricant sliding conditions. The test was conducted with specimens which have various arithmetic mean value and roughness pattern under the condition of different normal load. The experimental results show that the friction coefficient is decreased because of oxidation mass and valley effect as the normal loads increasing It was found that the specimens with surface roughness with a transverally oriented pattern have a smaller firction coefficient than the other two roughness patterns under the condition of the roughness values of Ra=0.5 and Ra=0.2 .

  • PDF

A Study on the Evaluation of Cooling Demand using Cooling Gas Sales (냉방용 가스사용을 중심으로 추정한 냉방전력수요 평가)

  • KIM C.S.;Rhee C.H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.660-662
    • /
    • 2004
  • Cooling demand in Korea has increased constantly. Furthermore, an evaluation and savings of cooling demand has impacted on summer DSM and investment in Korea. Absorbed cooling system uses gas. It could achieve reductions in summer peak load and increase gas demand simultaneously. However its efficiency rate is lower than electric system. Gas cooling system uses separate meter. Therefore we could analyze monthly cooling demand and derive annual uses pattern. This paper analyzes demand pattern of gas cooling and its effects on electricity savings. Also this paper presents the course of policy in electricity sector on spreading of gas cooling measures.

  • PDF

Planning ESS Managemt Pattern Algorithm for Saving Energy Through Predicting the Amount of Photovoltaic Generation

  • Shin, Seung-Uk;Park, Jeong-Min;Moon, Eun-A
    • Journal of Integrative Natural Science
    • /
    • v.12 no.1
    • /
    • pp.20-23
    • /
    • 2019
  • Demand response is usually operated through using the power rates and incentives. Demand management based on power charges is the most rational and efficient demand management method, and such methods include rolling base charges with peak time, sliding scaling charges depending on time, sliding scaling charges depending on seasons, and nighttime power charges. Search for other methods to stimulate resources on demand by actively deriving the demand reaction of loads to increase the energy efficiency of loads. In this paper, ESS algorithm for saving energy based on predicting the amount of solar power generation that can be used for buildings with small loads not under electrical grid.

3D Cube Mining and Calendar Pattern Based Temporal Mining for Analyzing Power Load Pattern (전력 부하 패턴 분석을 위한 3차원 큐브 마이닝과 캘랜더 패턴 기반 시간 데이터 마이닝)

  • Park, Jin-Hyoung;Shin, Jin-Ho;Piao, Minghao;Lee, Heon-Gyu;Ryu, Keun-Ho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2008.05a
    • /
    • pp.200-203
    • /
    • 2008
  • 최근 전력산업에서의 에너지 가격 및 공급과 수요의 변동, 그리고 기후의 변화에 의해서 부하 예측은 전력회사 경영방침 계획에 있어 중요한 요소가 되었다. 이 논문에서 전력계통의 최적 운용 계획을 위하여 우리가 제안한 기법은 다차원 분석이 가능한 3D 큐브 마이닝과 시간의 변화에 따른 패턴 예측이 가능한 캘린더 기반 시간 데이터 마이닝 기법이다. 이를 통하여 무선 부하 감시 시스템의 부하 데이터의 다차원 분석이 가능하고, 시간 변화에 따른 서로 다른 부하 패턴의 예측이 가능하도록 한다.

The Characteristics of Control Scheme and Inner Feedback Control with HC of Current-Controlled PWM Inverter (전류제어 PWM인버터의 HC에 대한 제어방식과 내부 피이드백제어의 특성)

  • 정동화;배진호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.9
    • /
    • pp.1031-1041
    • /
    • 1992
  • Existing current-controlled inverters with hysteresis controller (HC) result in the dependence of the inverter on its load characteristics, poor inverter utilization due to too much or too little supply voltage, and the current error in the hysteresis band(HB) which causes deterioration of operation of the supplied motor. In this paper, techniques and results of modeling the operation of current-controlled three phase power inverter with HC are presented. Four symmetrical control schemes are considered: the so called three independent control, three semi-dependent control(a), three semi-dependent control(b) and three dependent control each using three current controller. The dependence of the inverter on its load has been studied. To overcome this difficulty, an inner feedback control has been introduced and optimum parameter has been determined. With the addition of an inner feedback control, adjustment of the switching frequency to a desired value is possible. Also, this modification improves operating characteristics of inverter by enforcing a switching pattern of low dependence on the load, resulting in significantly improved quality of the output current.

  • PDF

The FEM Analysis on the Crestal Cortical Bone around the Implant according to the Cancellous Bone Density and Loading Positions (임프란트 매식시 해면골질의 차이에 따른 치밀골 상 응력분석)

  • Jeung, Sin-Young;Kim, Chang-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.69-78
    • /
    • 2007
  • This study was performed to compare the stress distribution pattern in the crestal cortical bone and cancellous bone using 3-dimensional finite element stress analysis when 2 different Young's modulus(high modulus, model 1; low modulus, model 2) of cancellous bone was assumed. For the analysis, a finite element model was designed to have two square-threaded implants fused together and located at first and second molar area. Stress distribution was observed when vertical load of 200N was applied at several points on the occlusal surfaces of the implants, including central fossa, points 1.5mm, 2mm, 3mm and 3.5mm buccally away from central fossa. The results were as follows; 1. In both model, the maximum Von-Mises stress in the crestal cortical bone was greater when the load was applied at the central point, points 1.5mm and 2mm buccally away from central fossa than other cases. 2. In the cortical bone around first and second molar, model 2 showed greater Von-Mises stress than model 1. It is concluded that when the occlusal contact is afforded, the distribution of stress varies depending on the density of cancellous bone and the location of loading. More favorable stress distribution is expected when the contact load is applied within the diameter of fixtures.

Development of Performance Evaluation and Control System of Multi-Air Conditioner (멀티에어컨의 성능평가 및 제어시스템 개발에 대한 연구)

  • Lee H.W.;Ko K.W.;Gwon Yeong-Cheol;Lee J.H.;Lee Y.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1107-1114
    • /
    • 2005
  • The running condition of multi-system air conditioner is prone to vary largely as it is designed for individual conditioning in each space of middle and small sized buildings. This leads to overcooling in case of partial load run, while the lack of capacity happens in case of full load run. Besides these, there exist such problems as instabilities due to the uneven refrigerant distribution caused by fluctuation of load and the change in piping line. Based upon the basic study on the function characteristics found in parts needed for maximized system working design in order to troubleshoot, the system functioning pattern should be identified through the different tests with various operating circumstances and the analysis models should be developed. With this ground, the control logic has to be made to have a control over capacity and make possible the efficient distribution of refrigerant.

  • PDF

Power Signal Recognition with High Order Moment Features for Non-Intrusive Load Monitoring (비간섭 전력 부하 감시용 고차 적률 특징을 갖는 전력 신호 인식)

  • Min, Hwang-Ki;An, Taehun;Lee, Seungwon;Lee, Seong Ro;Song, Iickho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.7
    • /
    • pp.608-614
    • /
    • 2014
  • A pattern recognition (PR) system is addressed for non-intrusive load monitoring. To effectively recognize two appliances (for example, an electric iron and a cook top), we propose a novel feature extraction method based on high order moments of power signals. Simulation results confirm that the PR system with the proposed high order moment features and kernel discriminant analysis can effectively separate two appliances.

A Study on EVs Smart Charging Scheme Considering Time-of-Use Price and Actual Data (Time-of-Use 가격 및 실제 데이터를 고려한 전기 자동차 스마트 충전기법에 대한 연구)

  • Kim, Junhyeok;Kim, Chulhwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1793-1799
    • /
    • 2016
  • As one of the main trends in global industries is eco-friendly energy, the interest on Electric Vehicle(EV) has been increased. However, if large amount of EVs start to charging, it could cause rapid increase in demand power of the power system. To guarantee stable operation of the power system, those unpredictable power consume should be mitigated. In this paper, therefore, we propose a practical smart EVs charging scheme to prevent the rapid increase of the demand power and also provide load flattening function. For that we considered Time-of-Use(ToU) price and actual data such as driving pattern and parameters of distribution system. Simulation results show that the proposed method provides proper load flattening function while preventing the rapid increase of the demand power of the power system.